965 resultados para Frost heave, Fine content, Laboratory, Frost heave test, Thermal conductivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article studies a model where, as a consequence of private information, agents do not have incentive to invest in a desired joint project, or a public good, when they are unable to have prior discussion with their partners. As a result, the joint project is never undertaken and inefficiency is observed. Agastya, Menezes and Sengupta (2007) prove that with a prior stage of communication, with a binary message space, it is possible to have some efficiency gain since "all ex-ante and interim efficient equilibria exhibit a simple structure". We show that any finite message space does not provide efficiency gain on the simple structure discussed in that article. We use laboratory experiments to test these results. We find that people do contribute, even without communication, and that any kind of communication increases the probability of project implementation. We also observed that communication reduces the unproductive contribution, and that a large message space cannot provide efficiency gain relative to the binary one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to study the efficiency of electrical conductivity test in evaluating the quality of castor seeds. Emergence of seedlings was evaluated in the field, with five seed lots of cv. AL Guarany 2002. The seeds were submitted to the following tests: germination; first count of germination; accelerated aging (45 degrees C by 24 to 100% UR), emergence of seedlings in the field, rate of speed of development of seedlings and electrical conductivity, testing the periods (2, 4, 6, 8 and 24 hours) and the number of seeds (25,50 and 75) in 75ml of distilled water conditioning to 25 degrees C. A completely randomized design was used. The averages were compared by the Tukey test at 5%. The mean laboratory and field test data were correlated. Electrical conductivity test for 4 hours with 25 seeds and 6 hours with 50 seeds, and the rate of speed emergency proved efficient in the selection of lots vigor by providing information equivalent to the emergence of seedlings in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dentro de um programa de controle de qualidade, a avaliação do vigor de sementes é fundamental e necessária para o sucesso da produção. Este trabalho teve como objetivo avaliar a eficiência de diferentes testes de vigor na avaliação da qualidade fisiológica de sementes de triticale (X. triticosecale Wittmack), buscando a diferenciação de lotes. Cinco lotes da cultivar 'IPR 111' foram submetidos ao teste de germinação, primeira contagem, teste de frio, condutividade elétrica (50 sementes 50mL-1 de água; 25°C 24h-1), lixiviação de potássio (50 sementes 75mL-1 de água; 25°C 3h-1), envelhecimento acelerado (43°C 48h-1) e teor de água. O teste de condutividade elétrica e lixiviação de potássio são eficientes na diferenciação do vigor de lotes de sementes de triticale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Specific heat, thermal conductivity, thermal diffusivity, and density of coffee extract were experimentally determined in the range of 0.49 to 0.90 (wet basis) water content and at temperatures varying from 30 to 82 degreesC. Thermal conductivity and specific heat were measured by means of the same apparatus- a cell constituted of two concentric cylinders - operating at steady and unsteady state, respectively. The thermal diffusivity was measured by the well-known Dickerson's method and density was determined by picnometry. The results obtained were used to derive mathematical models for predicting these properties as a function of concentration and temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific heat, thermal conductivity, thermal diffusivity and density of Brazilian orange juice were determined between 0.34 and 0.73 (w/w) water content and with temperatures from 0.5 to 62°C. The experimental data were fitted as functions of temperature and water content and all properties showed a linear dependency with these variables. In the tested range, the water content exhibited a greater influence on the analyzed properties than temperature. © 1998 Elsevier Science Limited. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific heat, thermal conductivity and density of passion fruit juice were experimentally determined from 0.506 to 0.902 (wet basis) water content and temperatures from 0.4 to 68.8C. The experimental results were compared with existing and widely used models for the thermal properties. In addition, based on empiric equations from literature, new simple models were parameterized with a subset of the total experimental data. The specific heat and thermal conductivity showed linear dependency on water content and temperature, while the density was nonlinearly related to water content. The generalized predictive models were considerably good for this product but the empiric, product-specific models developed in the present work yield better predictions. Even though the existing models showed a moderate accuracy, the new simple ones would be preferred, because they constitute an easier and direct way of evaluating the thermal properties of passion fruit juice, requiring no information about the chemical composition of the product, and a reduced time of the estimation procedure, as the new empiric models are described in terms of only two physical parameters, the water content and the temperature. © Copyright 2005, Blackwell Publishing All Rights Reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Design parameters, process flows, electro-thermal-fluidic simulations and experimental characterizations of Micro-Electro-Mechanical-Systems (MEMS) suited for gas-chromatographic (GC) applications are presented and thoroughly described in this thesis, whose topic belongs to the research activities the Institute for Microelectronics and Microsystems (IMM)-Bologna is involved since several years, i.e. the development of micro-systems for chemical analysis, based on silicon micro-machining techniques and able to perform analysis of complex gaseous mixtures, especially in the field of environmental monitoring. In this regard, attention has been focused on the development of micro-fabricated devices to be employed in a portable mini-GC system for the analysis of aromatic Volatile Organic Compounds (VOC) like Benzene, Toluene, Ethyl-benzene and Xylene (BTEX), i.e. chemical compounds which can significantly affect environment and human health because of their demonstrated carcinogenicity (benzene) or toxicity (toluene, xylene) even at parts per billion (ppb) concentrations. The most significant results achieved through the laboratory functional characterization of the mini-GC system have been reported, together with in-field analysis results carried out in a station of the Bologna air monitoring network and compared with those provided by a commercial GC system. The development of more advanced prototypes of micro-fabricated devices specifically suited for FAST-GC have been also presented (silicon capillary columns, Ultra-Low-Power (ULP) Metal OXide (MOX) sensor, Thermal Conductivity Detector (TCD)), together with the technological processes for their fabrication. The experimentally demonstrated very high sensitivity of ULP-MOX sensors to VOCs, coupled with the extremely low power consumption, makes the developed ULP-MOX sensor the most performing metal oxide sensor reported up to now in literature, while preliminary test results proved that the developed silicon capillary columns are capable of performances comparable to those of the best fused silica capillary columns. Finally, the development and the validation of a coupled electro-thermal Finite Element Model suited for both steady-state and transient analysis of the micro-devices has been described, and subsequently implemented with a fluidic part to investigate devices behaviour in presence of a gas flowing with certain volumetric flow rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il lavoro di questa tesi riguarda principalmente la progettazione, simulazione e test di laboratorio di tre versioni successive di schede VME, chiamate Read Out Driver (ROD), che sono state fabbricate per l'upgrade del 2014 dell'esperimento ATLAS Insertable B-Layer (IBL) al CERN. IBL è un nuovo layer che diverrà parte del Pixel Detector di ATLAS. Questa tesi si compone di una panoramica descrittiva dell'esperimento ATLAS in generale per poi concentrarsi sulla descrizione del layer specifico IBL. Inoltre tratta in dettaglio aspetti fisici e tecnici: specifiche di progetto, percorso realizzativo delle schede e test conseguenti. Le schede sono state dapprima prodotte in due prototipi per testare le prestazioni del sistema. Queste sono state fabbricate al fine di valutare le caratteristiche e prestazioni complessive del sistema di readout. Un secondo lotto di produzione, composto di cinque schede, è stato orientato alla correzione fine delle criticità emerse dai test del primo lotto. Un'indagine fine e approfondita del sistema ha messo a punto le schede per la fabbricazione di un terzo lotto di altre cinque schede. Attualmente la produzione è finita e complessivamente sono state realizzate 20 schede definitive che sono in fase di test. La produzione sarà validata prossimamente e le 20 schede verranno consegnate al CERN per essere inserite nel sistema di acquisizione dati del rivelatore. Al momento, il Dipartimento di Fisica ed Astronomia dell'Università di Bologna è coinvolto in un esperimento a pixel solamente attravers IBL descritto in questa tesi. In conclusione, il lavoro di tesi è stato prevalentemente focalizzato sui test delle schede e sul progetto del firmware necessario per la calibrazione e per la presa dati del rivelatore.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwater represents one of the most important resources of the world and it is essential to prevent its pollution and to consider remediation intervention in case of contamination. According to the scientific community the characterization and the management of the contaminated sites have to be performed in terms of contaminant fluxes and considering their spatial and temporal evolution. One of the most suitable approach to determine the spatial distribution of pollutant and to quantify contaminant fluxes in groundwater is using control panels. The determination of contaminant mass flux, requires measurement of contaminant concentration in the moving phase (water) and velocity/flux of the groundwater. In this Master Thesis a new solute flux mass measurement approach, based on an integrated control panel type methodology combined with the Finite Volume Point Dilution Method (FVPDM), for the monitoring of transient groundwater fluxes, is proposed. Moreover a new adsorption passive sampler, which allow to capture the variation of solute concentration with time, is designed. The present work contributes to the development of this approach on three key points. First, the ability of the FVPDM to monitor transient groundwater fluxes was verified during a step drawdown test at the experimental site of Hermalle Sous Argentau (Belgium). The results showed that this method can be used, with optimal results, to follow transient groundwater fluxes. Moreover, it resulted that performing FVPDM, in several piezometers, during a pumping test allows to determine the different flow rates and flow regimes that can occurs in the various parts of an aquifer. The second field test aiming to determine the representativity of a control panel for measuring mass flus in groundwater underlined that wrong evaluations of Darcy fluxes and discharge surfaces can determine an incorrect estimation of mass fluxes and that this technique has to be used with precaution. Thus, a detailed geological and hydrogeological characterization must be conducted, before applying this technique. Finally, the third outcome of this work concerned laboratory experiments. The test conducted on several type of adsorption material (Oasis HLB cartridge, TDS-ORGANOSORB 10 and TDS-ORGANOSORB 10-AA), in order to determine the optimum medium to dimension the passive sampler, highlighted the necessity to find a material with a reversible adsorption tendency to completely satisfy the request of the new passive sampling technique.