997 resultados para Frequency Bioelectrical-impedance
Resumo:
Bioelectrical impedance measurements are widely used for the study of body composition. Commonly measurements are made at 50 kHz to estimate total body water or at low frequencies (< 10 kHz) to estimate extracellular fluid volume. These measurements can be obtained as single measurements at discrete frequencies, or as fitted data interpolated from plots of measurements made at multiple frequencies. This study compared single frequency and multiple frequency (MF) measurements taken in the intensive care environment. MF bioimpedance (4-1000 kHz) was measured on an adult with and without cardiorespiratory monitoring, and on babies in the neonatal intensive care unit. Measurements obtained at individual frequencies were plotted against frequency and examined for the presence of outlying points. Fitted data for measurements obtained at 5 kHz and 50 kHz with and without cardiorespiratory monitoring were compared. Significant artefacts were detected in measurements at approximately 50 kHz and at integral divisions of this frequency as a result of interference from cardiorespiratory monitors. Single frequency measurements taken at these frequencies may be subject to errors that would be difficult to detect without the aid of information obtained from MF measurements.
Resumo:
Detailed analysis of body composition in children has helped to understand changes that occur in growth and disease. Bioelectrical impedance analysis (BIA) has gained popularity as a simple, non-invasive and inexpensive tool of body composition assessment. Being an indirect technique, prediction equations have to be used in the assessment of body composition. There are many prediction equations available in the literature for the assessment of body composition from BIA. This study aims to cross-validate some of those prediction equations to determine the suitability of their use on Australian children of white Caucasian and Sri Lankan origins. Height, weight and BIA were measured. Total body water was measured using the isotope dilution method (D2O). Fat-mass (FM) and %FM were estimated from BIA using ten prediction equations described in the literature. Five to 14.99-year-old healthy, 96 white Caucasians and 42 Sri Lankan children were studied. The equation of Schaefer et al was the most suitable prediction equation for this group with the lowest mean bias for %FM assessment in both Caucasian (–1.0±9.6%) and Sri Lankan (1.6±5.2%) children and the fat content of the individuals did not influence the predictions by this equation. Impedance index (height2/impedance) explained for 80% of TBW in white Caucasians and 93% in Sri Lankans and figures were similar for the prediction of FFM. We conclude that BIA can be used effectively in the assessment of body composition in children. However, for the assessment of body composition using BIA, either prediction equations should be derived to suit the local populations or existing equations should be cross-validated to determine their suitability before their application.
Resumo:
Introduction: Body mass index (BMI) has been one of the methods most frequently used for diagnose obesity, but it isn't consider body composition. Objective: This study intends to apply one new adiposity index, the BMI adjusted for fat mass (BMIfat) developed by Mialich, et al. (2011), in a adult Brazilian sample. Methods: A cross-sectional study with 501 individuals of both genders (366 women, 135 men) aged 17 to 38 years and mean age was 20.4 ± 2.8 years, mean weight 63.0 ± 13.5 kg, mean height 166.9 ± 9.0 cm, and BMI 22.4 ± 3.4 kg/m². Results and discussion: High and satisfactory R2 values were obtained, i.e., 91.1%, 91.9% and 88.8% for the sample as a whole and for men and women, respectively. Considering this BMIfat were developed new ranges, as follows: 1.35 to 1.65 (nutritional risk for malnutrition), > 1.65 and ≤ 2.0 (normal weight) and > 2.0 (obesity). The BMIfat had a more accurate capacity of detecting obese individuals (0.980. 0.993, 0.974) considering the sample as a whole and women and men, respectively, compared to the traditional BMI (0.932, 0.956, 0.95). Were also defined new cut-off points for the traditional BMI for the classification of obesity, i.e.: 25.24 kg/m² and 28.38 kg/m² for men and women, respectively. Conclusion: The BMIfat was applied for the present population and can be adopted in clinical practice. Further studies are needed to determine its application to different ethnic groups and to compare this index to others previously described in the scientific literature.
Resumo:
Lymphedema is an accumulation of lymph fluid in the limb resulting from an insufficiency of the lymphatic system. It is commonly associated with surgical or radiotherapy treatment for breast cancer. As with many progressively debilitating disorders, the effectiveness of treatment is significantly improved by earlier intervention. Multiple frequency bioelectrical impedance analysis (MFBIA) previously was shown to provide accurate relative measures of lymphedema in the upper limb in patients after treatment for breast cancer, This presentation reports progress to date on a three-year prospective study to evaluate the efficacy of MFBIA to predict the early onset of lymphedema in breast cancer patients following treatment. Bioelectrical impedance measurements of each upper limb were recorded in a group of healthy control subjects (n = 50) to determine the ratio of extracellular limb-fluid volumes. From this population, the expected normal range of asymmetry (99.7% confidence) between the limbs was determined, Patients undergoing surgery to treat breast cancer were recruited into the study, and MFBIA measurements were recorded presurgery, at one month and three months after surgery, and then at two-month intervals for up to 24 months postsurgery, When patients had an MFBIA measure outside the 99.7% range of the control group, they were referred to their physician for clinical assessment. Results to date: Over 100 patients were recruited into the study over the past two years; at present, 19 have developed lymphedema and, of these, 12 are receiving treatment. In each of these 19 cases, MFBIA predicted the onset of the condition up to four months before it could be clinically diagnosed. The false-negative rate currently is zero, The study will continue to monitor patients over the remaining year to accurately ascertain estimates of specificity and sensitivity of the procedure.
Resumo:
Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb, Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p< 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity, than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.
Resumo:
The purpose of the present study was to investigate percentage body fat (%BF) differences in three Spanish dance disciplines and to compare skinfold and bioelectrical impedance predictions of body fat percentage in the same sample. Seventy-six female dancers, divided into three groups, Classical (n=23), Spanish (n=29) and Flamenco (n=24), were measured using skinfold measurements at four sites: triceps, subscapular, biceps and iliac crest, and whole body multi-frequency bioelectrical impedance (BIA). The skin-fold measures were used to predict body fat percentage via Durnin and Womersley's and Segal, Sun and Yannakoulia equations by BIA. Differences in percent fat mass between groups (Classical, Spanish and Flamenco) were tested by using repeated measures analysis (ANOVA). Also, Pearson's product-moment correlations were performed on the body fat percentage values obtained using both methods. In addition, Bland-Altman plots were used to assess agreement, between anthropometric and BIA methods. Repeated measures analysis of variance did not found differences in %BF between modalities (p<0.05). Fat percentage correlations ranged from r= 0.57 to r=0.97 (all, p<0.001). Bland-Altman analysis revealed differences between BIA Yannakoulia as a reference method with BIA Segal (-0.35 ± 2.32%, 95%CI: -0.89to 0.18, p=0.38), with BIA Sun (-0.73 ± 2.3%, 95%CI: -1.27 to -0.20, p=0.014) and Durnin-Womersley (-2.65 ± 2,48%, 95%CI: -3.22 to -2.07, p<0.0001). It was concluded that body fat percentage estimates by BIA compared with skinfold method were systematically different in young adult female ballet dancers, having a tendency to produce underestimations as %BF increased with Segal and Durnin-Womersley equations compared to Yannakoulia, concluding that these methods are not interchangeable.
Resumo:
Multi-frequency bioimpedance analysis (MFBIA) was used to determine the impedance, reactance and resistance of 103 lamb carcasses (17.1-34.2 kg) immediately after slaughter and evisceration. Carcasses were halved, frozen and one half subsequently homogenized and analysed for water, crude protein and fat content. Three measures of carcass length were obtained. Diagonal length between the electrodes (right side biceps femoris to left side of neck) explained a greater proportion of the variance in water mass than did estimates of spinal length and was selected for use in the index L-2/Z to predict the mass of chemical components in the carcass. Use of impedance (Z) measured at the characteristic frequency (Z(c)) instead of 50 kHz (Z(50)) did not improve the power of the model to predict the mass of water, protein or fat in the carcass. While L-2/Z(50) explained a significant proportion of variation in the masses of body water (r(2) 0.64), protein (r(2) 0.34) and fat (r(2) 0.35), its inclusion in multi-variate indices offered small or no increases in predictive capacity when hot carcass weight (HCW) and a measure of rib fat-depth (GR) were present in the model. Optimized equations were able to account for 65-90 % of the variance observed in the weight of chemical components in the carcass. It is concluded that single frequency impedance data do not provide better prediction of carcass composition than can be obtained from measures of HCW and GR. Indices of intracellular water mass derived from impedance at zero frequency and the characteristic frequency explained a similar proportion of the variance in carcass protein mass as did the index L-2/Z(50).