73 resultados para Foveal
Resumo:
PURPOSE: To compare the efficacy and safety of ranibizumab and bevacizumab intravitreal injections to treat neovascular age-related macular degeneration (nAMD). DESIGN: Multicenter, noninferiority factorial trial with equal allocation to groups. The noninferiority limit was 3.5 letters. This trial is registered (ISRCTN92166560). PARTICIPANTS: People >50 years of age with untreated nAMD in the study eye who read =25 letters on the Early Treatment Diabetic Retinopathy Study chart. METHODS: We randomized participants to 4 groups: ranibizumab or bevacizumab, given either every month (continuous) or as needed (discontinuous), with monthly review. MAIN OUTCOME MEASURES: The primary outcome is at 2 years; this paper reports a prespecified interim analysis at 1 year. The primary efficacy and safety outcome measures are distance visual acuity and arteriothrombotic events or heart failure. Other outcome measures are health-related quality of life, contrast sensitivity, near visual acuity, reading index, lesion morphology, serum vascular endothelial growth factor (VEGF) levels, and costs. RESULTS: Between March 27, 2008 and October 15, 2010, we randomized and treated 610 participants. One year after randomization, the comparison between bevacizumab and ranibizumab was inconclusive (bevacizumab minus ranibizumab -1.99 letters, 95% confidence interval [CI], -4.04 to 0.06). Discontinuous treatment was equivalent to continuous treatment (discontinuous minus continuous -0.35 letters; 95% CI, -2.40 to 1.70). Foveal total thickness did not differ by drug, but was 9% less with continuous treatment (geometric mean ratio [GMR], 0.91; 95% CI, 0.86 to 0.97; P = 0.005). Fewer participants receiving bevacizumab had an arteriothrombotic event or heart failure (odds ratio [OR], 0.23; 95% CI, 0.05 to 1.07; P = 0.03). There was no difference between drugs in the proportion experiencing a serious systemic adverse event (OR, 1.35; 95% CI, 0.80 to 2.27; P = 0.25). Serum VEGF was lower with bevacizumab (GMR, 0.47; 95% CI, 0.41 to 0.54; P
Resumo:
Presentation Abstract - Purpose:Serial intravitreal ranibizumab injections are the main treatment for wet age- related macular degeneration (AMD), and patients are monitored by optical coherence tomography (OCT). Our objective in conducting this study is to determine whether serial intravitreal injections of ranibizumab in eyes with wet AMD alter the vitreo-macular interface (VMI) Methods - Using a Topcon Spectral Domain OCT, we performed a prospective, observational study of 87 eyes of 82 consecutive patients undergoing treatment with intravitreal ranibizumab for wet AMD, with each patient followed up for a minimum of 6 months. The mean number of intravitreal ranibizumab injections was 4.28, range 3-6. Using macular OCT scans, the area of VMI was closely examined, for vitreo-macular adhesion (VMA), defined as perifoveal posterior vitreous detachment (PVD) with posterior vitreous attached to fovea. Any OCT separation of posterior vitreous face was observed and measured, every month for 6 months. Results - There was no change in the OCT appearance or measurement of VM interface in 80 eyes (92%). VM adhesion, defined on OCT as when the posterior hyaloid line is attached to inner foveal surface and dettached perifoveally, was identified in 7 out of 87 treated eyes (8%) .Of these 7 eyes, 1 eye developed complete PVD following three injections, 1 eye developed partial PVD and the remaining 5 eyes had no significant change in VM adhesion. Conclusions - To our knowledge this is the first study that has examined the VM interface following serial ranibizumab injections for wet AMD. This small pilot study suggests that most cases undergoing ranibizumab therapy suffer no disturbance to VM interface.
Resumo:
Poster section Design. Retrospective study. Purpose. To assess whether there are changes in foveal thickness (FT) and total macular volume (TMV) in pregnancy in diabetic subjects. Methods. The audit consisted of pregnant women with diabetes, with no maculopathy, who completed their antenatal care at Birmingham Heartlands Hospital. The Zeiss Stratus Optical coherence tomography (OCT) was performed on patients attending diabetic retinopathy (DR) screening at intervals throughout their pregnancy. To be included in the audit patients had to have at least one OCT scan during their pregnancy. Results. Altogether there were 8 type 1 and 22 type 2 patients with mean diabetes duration of 6 years (range 1-20). Mean gestation at DR screening with OCT during the first trimester was 9.7 weeks (6-13) (n=22). The mean and standard deviation for FT for the right was 179.1 µm ± 21.49 and for the left eye was 187.3 µm ± 23.55. The mean TMV was right 6.43 µm ± 0.35 and left 6.50 µm ± 0.39. The mean gestation at DR screening with OCT during the second trimester was 23.4 weeks (18-26) (n=25). The mean FT for the right was 191.4 µm ± 22.70 and the left 195.6 µm ± 24.77. The mean TMV was right 6.74 µm ± 0.45 and left 6.91 µm ± 0.35. The gestation of DR screening with OCT during the third trimester was 31.1 weeks (27-36) (n=15). The mean FT for the right was 181.5 µm ± 24.84 and for the left 193.1 µm ± 28.55. The mean TMV was right 6.80 µm ± 0.40 and left 6.84 µm ± 0.31. There were no significant differences in FT over the 3 trimesters. The TMV showed a significant difference when comparing the first and second trimesters (p<0.05). However, there was no significant statistical difference in TMV in the second and third trimesters. None of the patients showed any macula edema on the OCT. Conclusions. The results suggest there is no significant change in foveal thickness in pregnancy in diabetic subjects. There was a significant statistical difference in total macular volume in the second trimester; however, this would not be clinically significant. This is an important observation proven by the OCT which has not been previously studied.
Resumo:
Free Paper Sessions Design. Retrospective analysis. Purpose. To assess the prevalence of center-involving diabetic macular oedema (CIDMO) and risk factors. Methods. Retrospective review of patients who were screen positive for maculopathy (M1) during 2010 in East and North Birmingham. The CIDMO was diagnosed by qualitative identification of definite foveal oedema on optical coherence tomography (OCT). Results. Out of a total of 15,234 patients screened, 1194 (7.8%) were screen positive for M1 (64% bilateral). A total of 137 (11.5% of M1s) were diagnosed with macular oedema after clinical assessment. The OCT results were available for 123/137; 69 (56.1%) of these had CI-DMO (30 bilateral) which is 0.5% of total screens and 5.8% of those screen positive for M1. In those with CIDMO 60.9% were male and 63.8% Caucasian; 90% had type 2 diabetes and mean diabetes duration was 20 years (SD 9.7, range 2-48). Mean HbA1c was 8.34%±1.69, with 25% having an HbA1c =9%. Furthermore, 62% were on insulin, 67% were on antihypertensive therapy, and 64% were on a cholesterol-lowering drug. A total of 37.7% had an eGFR between 30% and 60% and 5.8% had eGFR <30. The only significant difference between the CIDMO and non-CIDMO group was mean age (67.83±12.26 vs 59.69±15.82; p=0.002). A total of 65.2% of those with CIDMO also had proliferative or preproliferative retinopathy in the worst eye and 68.1% had subsequently been treated with macular laser at the time of data review. Conclusions. The results show that the prevalence of CIDMO in our diabetic population was 0.5%. A significant proportion of macula oedema patients were found to have type 2 diabetes with long disease duration, suboptimal glycemic and hypertensive control, and low eGFR. The data support that medical and diabetic review of CIDMO patients is warranted particularly in the substantial number with poor glycemic control and if intravitreal therapies are indicated.
Resumo:
To review the literature on epidemiology, clinical features, diagnostic imaging, natural history, management, therapeutic approaches, and prognosis of myopic foveoschisis. A systematic Pubmed search was conducted using search terms: myopia, myopic, staphyloma, foveoschisis, and myopic foveoschisis. The evidence base for each section was organised and reviewed. Where possible an authors' interpretation or conclusion is provided for each section. The term myopic foveoschisis was first coined in 1999. It is associated with posterior staphyloma in high myopia, and is often asymptomatic initially but progresses slowly, leading to loss of central vision from foveal detachment or macular hole formation. Optical coherence tomography is used to diagnose the splitting of the neural retina into a thicker inner layer and a thinner outer layer, but compound variants of the splits have been identified. Vitrectomy with an internal limiting membrane peel and gas tamponade is the preferred approach for eyes with vision decline. There has been a surge of new information on myopic foveoschisis. Advances in optical coherence tomography will continually improve our understanding of the pathogenesis of retinal splitting, and the mechanisms that lead to macular damage and visual loss. Currently, there is a good level of consensus that surgical intervention should be considered when there is progressive visual decline from myopic foveoschisis.
Resumo:
PurposeTo develop and validate a classification system for focal vitreomacular traction (VMT) with and without macular hole based on spectral domain optical coherence tomography (SD-OCT), intended to aid in decision-making and prognostication.MethodsA panel of retinal specialists convened to develop this system. A literature review followed by discussion on a wide range of cases formed the basis for the proposed classification. Key features on OCT were identified and analysed for their utility in clinical practice. A final classification was devised based on two sequential, independent validation exercises to improve interobserver variability.ResultsThis classification tool pertains to idiopathic focal VMT assessed by a horizontal line scan using SD-OCT. The system uses width (W), interface features (I), foveal shape (S), retinal pigment epithelial changes (P), elevation of vitreous attachment (E), and inner and outer retinal changes (R) to give the acronym WISPERR. Each category is scored hierarchically. Results from the second independent validation exercise indicated a high level of agreement between graders: intraclass correlation ranged from 0.84 to 0.99 for continuous variables and Fleiss' kappa values ranged from 0.76 to 0.95 for categorical variables.ConclusionsWe present an OCT-based classification system for focal VMT that allows anatomical detail to be scrutinised and scored qualitatively and quantitatively using a simple, pragmatic algorithm, which may be of value in clinical practice as well as in future research studies.
Resumo:
Purpose: Several studies have suggested accommodative lags may serve as a stimulus for myopic growth, and while a blurred foveal image is believed to the main stimulus for accommodation, spectral composition of the retinal image is also believed to influence accommodative accuracy. Of particular interest is how altering spectral lighting conditions influences accommodation in the presence of soft multifocal contact lenses, which are currently being used off-label for myopia control. Methods: Accommodative responses were assessed using a Grand Seiko WAM-5500 autorefractor for four target distances: 25, 33, 50, and 100cm for 30 young adult subjects (14 myopic, 16 emmetropic; mean refractive errors (±SD, D) -4.22±2.04 and -0.15±0.67 respectively). Measurements were obtained with four different soft contact lenses, Single vision distance (SVD), Single vision near (SVN), Centre-Near (CN) and Centre-Distance (CD) (+1.50 add), and three different lighting conditions: red (peak λ 632nm), blue (peak λ 460nm), and white (peak λ 560nm). Corrections for chromatic differences in refraction were made prior to calculating accommodative errors. Results: The size of accommodative errors was significantly affected by lens design (p<0.001), lighting (p=0.027), and target distance (p=0.009). Mean accommodative errors were significantly larger with the SV lenses compared to the CD and CN designs (p<0.001). Errors were also significantly larger under blue light compared to white (p=0.004) and a significant interaction noted between lens design and lighting (p<0.001). Blue light generally decreased accommodative lags and increased accommodative leads relative to white and red light, the opposite was true of red light (p≤0.001). Lens design also significantly influenced direction of accommodative error (i.e. lag or lead) (p<0.001). Interactions with or between refractive groups were not found to be statistically significant for either the magnitude or direction of accommodative error (p>0.05 for all). Conclusions: Accuracy of accommodation is affected by both lens design and by wavelength of lighting. These accommodative lag data lend some support to recent speculation about the potential therapeutic value of lighting with a spectral bias towards blue during near work for myopia, although such treatment effects are likely to be more subtle under broad compared to the narrow spectrum lighting conditions used here.
Resumo:
Optical coherence tomography (OCT) is a noninvasive three-dimensional interferometric imaging technique capable of achieving micrometer scale resolution. It is now a standard of care in ophthalmology, where it is used to improve the accuracy of early diagnosis, to better understand the source of pathophysiology, and to monitor disease progression and response to therapy. In particular, retinal imaging has been the most prevalent clinical application of OCT, but researchers and companies alike are developing OCT systems for cardiology, dermatology, dentistry, and many other medical and industrial applications.
Adaptive optics (AO) is a technique used to reduce monochromatic aberrations in optical instruments. It is used in astronomical telescopes, laser communications, high-power lasers, retinal imaging, optical fabrication and microscopy to improve system performance. Scanning laser ophthalmoscopy (SLO) is a noninvasive confocal imaging technique that produces high contrast two-dimensional retinal images. AO is combined with SLO (AOSLO) to compensate for the wavefront distortions caused by the optics of the eye, providing the ability to visualize the living retina with cellular resolution. AOSLO has shown great promise to advance the understanding of the etiology of retinal diseases on a cellular level.
Broadly, we endeavor to enhance the vision outcome of ophthalmic patients through improved diagnostics and personalized therapy. Toward this end, the objective of the work presented herein was the development of advanced techniques for increasing the imaging speed, reducing the form factor, and broadening the versatility of OCT and AOSLO. Despite our focus on applications in ophthalmology, the techniques developed could be applied to other medical and industrial applications. In this dissertation, a technique to quadruple the imaging speed of OCT was developed. This technique was demonstrated by imaging the retinas of healthy human subjects. A handheld, dual depth OCT system was developed. This system enabled sequential imaging of the anterior segment and retina of human eyes. Finally, handheld SLO/OCT systems were developed, culminating in the design of a handheld AOSLO system. This system has the potential to provide cellular level imaging of the human retina, resolving even the most densely packed foveal cones.
Resumo:
Purpose: Albinism is a rare genetic disorder of melanin production, which can affect only eyes or simultaneously eyes and skin/hair, resulting respectively in ocular (OA) or oculocutaneous albinism (OCA). Through of a case report of a child with OCA we pretend review ophthalmological manifestations of albinism. Case Report: A girl of West African descent was referenced to our appointment for ophthalmological evaluation of oculocutaneous albinism. Visual acuity was 20/310 OD e 20/630 OS by teller cards. In biomicroscopy, iris hypopigmentation and transillumination was visible, allowing to see spiral vessels and other iris details. Fundoscopy showed a denser and complex choroidal circulation due to lack of pigment in retinal pigment epithelium. Foveal hypoplasia was assumed because foveal pit is not apparent and vessels become less respectful of normal arcade and transverse the macula. Results: Melanin plays an important role in the development of the optic system and it’s absence leads to diverse ocular manifestations, such as: iris hypopigmentation and transillumination , reducted pigmentation of retinal pigment epithelium cells, photoreceptor rod cell deficits, foveal hypoplasia, optic nerve hypoplasia and misrouting of optic nerve at the chiasm, with temporal retina fibers inappropriately routed contralaterally instead of ipsilaterally. Photophobia, nystagmus, reduced visual acuity, color impairment and strabismus are other manifestations usually seen in albinism. Conclusion: Ophthalmologists must be familiar with the specific visual manifestations and needs of these patients. It is essential to correct refractive error to optimize visual acuity. Patients should also be advised to wear tinted glasses and sunblock. In more severely affected children they may benefit of low vision consultation and specialized low vision aids like telescopes.
Resumo:
Objetivo: Evaluar mediante tomografía de coherencia óptica (OCT) las variaciones de espesor macular producidas a lo largo del tiempo en ojos pseudoafáquicos implantados con una lente intraocular (LIO) transparente en comparación con sus respectivos ojos contralarerales implantados con LIO amarilla. Métodos: El espesor macular de 36 ojos de 18 sujetos fue evaluado mediante OCT. Los sujetos presentaban edades superiores a 65 años y habían sido intervenidos de cataratas en ambos ojos en 2 cirugías independientes. La principal característica de los individuos es que llevaban implantada una LIO con diferente absorción en cada ojo: transparente (absorbente de la radiación ultravioleta) y amarilla (con filtro adicional absorbente de las radiaciones violeta-azul del espectro visible). El espesor macular se evaluó en 2 sesiones separadas en el tiempo por un intervalo de tiempo de 5 años, mediante el sistema Stratus-OCT (protocolo fast macular thickness). Se analizaron estadísticamente las diferencias en la evolución del espesor macular entre ojos con diferente tipo de LIO. Resultados: Tras 5 años de seguimiento, se observó que los ojos implantados con LIO transparente manifestaban una reducción del espesor macular estadísticamente significativa, superior a la esperada por el aumento de la edad. Sin embargo, los ojos implantados con LIOs amarillas mantuvieron su espesor macular estable. La disminución del espesor macular promedio en ojos implantados con LIO transparente fue de 5 ± 8 μm (p = 0,02) y la reducción del espesor foveal fue de 10 ± 17 μm (p = 0,02). Conclusiones: Los cambios de espesor macular producidos en ojos implantados con una LIO amarilla difieren de los cambios manifestados en ojos con LIO transparente. Estas observaciones apuntan a un posible efecto protector de las LIOs amarillas contra los efectos dañinos de la luz en sujetos pseudoafáquicos. Sin embargo, estudios con un mayor tamaño muestral y mayor tiempo de seguimiento son necesarios para confirmar que la protección inducida por este tipo de LIO es clínicamente significativa.
Resumo:
En esta tesis se aborda la implementación de un sistema completo de visión activa, en el que se capturan y generan imágenes de resolución espacial variable. Todo el sistema se integra en un sólo dispositivo del tipo AP SoC (All Programmable System on Chip), lo que nos permite llevar a cabo el codiseño hardware-software del mismo, implementando en la parte lógica los bloques de preprocesado intensivo, y en la parte software los algoritmos de procesado de control más complejo. El objetivo es que, trabajando con un campo visual del orden de Megapíxeles, se pueda procesar una tasa moderada de imágenes por segundo. Las imágenes multiresolución se generan a partir de sensores de resolución uniforme con una latencia nula, lo que permite tener preparada la imagen de resolución variable en el mismo instante en que se ha terminado de capturar la imagen original. Como innovación con respecto a las primeras contribuciones relacionadas con esta Tesis, se procesan imágenes con toda la información de color. Esto implica la necesidad de diseñar conversores entre espacios de color distintos, para adecuar la información al tipo de procesado que se va a realizar con ella. Estos bloques se integran sin alterar la latencia de entrega de los sucesivos fotogramas. El procesamiento de estas imágenes multirresolución genera un mapa de saliencia que permite mover la fóvea hacía la región considerada como más relevante en la escena. El contenido de la imagen se estructura en una jerarquía de niveles de abstracción. A diferencia de otras arquitecturas de este tipo, como son la pirámide regular y el polígono foveal, en las que se trabaja con imágenes de resolución uniforme en los distintos niveles de la jerarquía, la pirámide irregular foveal que se propone en esta tesis combina las ideas de trabajar con una imagen realmente multirresolución, que incluya el campo de visión completo que abarcan sensor y óptica, con el procesamiento jerárquico propio de las pirámides irregulares. Para ello en esta tesis se propone la implementación de un algoritmo de diezmado irregular que, tomando como base la imagen multirresolución, dará como resultado una estructura piramidal donde los distintos niveles no son imágenes sino grafos orientados a la resolución del problema de segmentación y estimación de saliencia. Todo el sistema se integra en torno a la arquitectura de bus AXI, que permite conectar entre si todos los cores desarrollados en la parte lógica, así como el acceso a la memoria compartida con los algoritmos implementados en la parte software. Esto es posible gracias a los bloques de acceso directo a memoria AXI-VDMA, en una propuesta de configuración que permite tanto la integración perfectamente coordinada de la transferencia de la imagen multirresolución generada a la zona de trabajo del algoritmo de segmentación como su recuperación para la posterior visualización del resultado del proceso, y todo ello con una tasa de trabajo que mejora los resultados de plataformas similares.
Resumo:
PURPOSE To investigate the cortical mechanisms that prevent diplopia in intermittent exotropia (X(T)) during binocular alignment (orthotropia). METHODS The authors studied 12 X(T) patients aged 5 to 22 years. Seventy-five percent had functional stereo vision with stereoacuity similar to that of 12 age-matched controls (0.2-3.7 min arc). Identical face images were presented to the two eyes for 400 ms. In one eye, the face was presented at the fovea; in the other, offset along the horizontal axis with up to 12° eccentricity. The task was to indicate whether one or two faces were perceived. RESULTS All X(T) patients showed normal diplopia when the nonfoveal face was presented to nasal hemiretina, though with a slightly larger fusional range than age-matched controls. However, 10 of 12 patients never experienced diplopia when the nonfoveal face was presented to temporal hemiretina (i.e., when the stimulus simulated exodeviation). Patients showed considerable variability when the single image was perceived. Some patients suppressed the temporal stimulus regardless of which eye viewed it, whereas others suppressed a particular eye even when it viewed the foveal stimulus. In two patients, the simulated exodeviation might have triggered a shift from normal to anomalous retinal correspondence. CONCLUSIONS Antidiplopic mechanisms in X(T) can be reliably triggered by purely retinal information during orthotropia, but the nature of these mechanisms varies between patients.
Resumo:
INTRODUCCIÓN: El Edema Macular (EM) es la principal causa de perdida de agudeza visual en pacientes con Oclusión Venosa Retiniana (OVR); luego del tratamiento, algunos pacientes persisten con mala agudeza visual. OBJETIVO: Realizar una Revisión Sistemática de la Literatura (RSL), para identificar la evidencia existente sobre factores tomográficos que predicen el resultado visual en pacientes con EM secundario a OVR. FUENTE DE LA INFORMACIÓN: PUBMED, MEDLINE, EMBASE, LILACS, COCHRANE, literatura gris. SELECCIÓN DE LOS ESTUDIOS: Ensayos Clínicos Controlados (ECC) y estudios observacionales analíticos. EXTRACCIÓN Y SÍNTESIS DE LOS DATOS: Dos investigadores seleccionaron los artículos de forma independiente. Se realizó una síntesis cualitativa de la información siguiendo las recomendaciones de la declaración PRISMA 2009. MEDIDAS Y DESENLACE PRINCIPAL: Grosor Retiniano Central (GRC), integridad de Banda Elipsoide e Integridad de Membrana Limitante Externa (MLE), determinados por SD OCT. El desenlace principal es la Agudeza Visual Mejor Corregida (AVMC) a los 6, 12,18 y/o 24 meses. RESULTADOS: Se identificaron 872 abstract y se incluyeron 8 artículos en el análisis cualitativo. Seis estudios evaluaron el GRC sin encontrar asociación con resultado visual final. Solo 2 estudios evaluaron y encontraron asociación estadísticamente significativa de la integridad de la MLE con el desenlace visual, Kang, H 2012 (r2 0,51 p 0,000), Rodriguez, F 2014 (p< 0,001). La integridad de la BE fue asociada a pronostico visual en 4 de 5 estudios que evaluaron esta variable, con resultados estadísticamente significativos. La AVMC de base también se asocio con desenlace visual en 4 de 5 estudios que la evaluaron. El mejor modelo que predice el resultado funcional según el estudio de Kang, H 2012 fue: Integridad de MLE, integridad de BE y AVMC de base (R2 0,671 p 0,000), a los 12 meses de seguimiento. CONCLUSION: La evidencia actual sugiere que la integridad de la BE y la MLE son predictores del resultados funcional en pacientes con EM secundario a OVR después de 6 o mas meses de seguimiento. Es necesario la realización de estudios controlados para llegar a resultados mas concluyentes.