893 resultados para Fluorescência de Raios-X


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: Os processos industriais geram grandes quantidades de resíduos, representando um grande desperdício de matéria prima e causando impactos negativos ao meio ambiente. No caso dos resíduos gerados pelas fábricas de pás eólicas para aerogeradores de Sorocaba-S.P., eles podem ser reaproveitados na incorporação em cimento Portland. O interesse é utilizá-los na construção civil como blocos sem fins estruturais para construção de muros, guias, calçadas, pisos, etc. Os corpos confeccionados devem obedecer às normas técnicas brasileiras e as suas propriedades relativas à resistência, compressão, absorção de água e distribuição espacial dos resíduos nestes corpos devem ser avaliadas. Objetivos: Devido à importância de se conhecer as propriedades dos corpos produzidos com a incorporação de resíduos de pás eólicas, este trabalho faz uma avaliação através de imagens de raios X de sua distribuição espacial para verificar a viabilidade do emprego desta técnica no estudo da incorporação de resíduos para, futuramente, em conjunto com outras pesquisas que estão sendo realizadas, verificar a relação desta distribuição com as propriedades mecânicas dos corpos produzidos. Métodos: Objetivando a incorporação desse resíduo como substituto parcial dos agregados miúdos em argamassa, foram fabricados corpos de prova (CPs) seguindo as normas da ABNT-NBR 5738. Todos os corpos foram desmoldados após 24 horas de sua confecção e imersos em água por 28 dias para a cura. Utilizou-se o traço 3:1, areia e cimento, em relação a massa dos componentes, ou seja, para cada 300 g de areia adicionou-se 100 g de cimento. Na confecção de argamassa com resíduo utilizou-se o mesmo traço, porém com a substituição de parte da areia pelo resíduo. Foram fabricados CPs com 5%, 15%, 50% e 0% de resíduo para que este sirva de referência. Como os corpos possuem um formato cilíndrico, foram obtidas imagens em duas projeções: frontal e superior utilizando um equipamento digital com os seguintes parâmetros: 83 kVp e 16 mAs e, 85 kVp e 30 mAs, respectivamente. Resultados: As imagens mostram que na projeção frontal é possível verificar que a distribuição do resíduo nos corpos é homogênea, o que pode proporcionar uniformidade nos resultados de testes de resistência à compressão que serão realizados futuramente. Porém, na projeção superior ainda será necessário um estudo dos parâmetros que deverão ser utilizados no equipamento de raios X para melhorar a sua qualidade. Além disso, métodos de processamento digital de imagens poderão ser aplicados nas imagens para auxiliar na visualização dos resíduos incorporados. Também pode ser visto nas imagens que a forma utilizada para a incorporação do resíduo resulta na sua distribuição uniforme, compatível com o que se deseja neste tipo de incorporação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O crescente interesse pelo uso de combustíveis renováveis nos últimos anos fez com que culturas oleaginosas, como a mamona, se tornassem importante objeto de estudo. No entanto, para a instalação de campos desta cultura, é imprescindível o uso de sementes de alta qualidade. O objetivo da pesquisa contida neste trabalho foi verificar a eficiência do teste de raios X na avaliação da qualidade de sementes de mamona após a colheita e armazenamento. Três lotes de sementes da cv. 'IAC-2028' (provenientes, respectivamente, dos racemos primário, secundário e terciário) e dois lotes da cv. 'Guarani' (lotes comerciais com sementes de todos os racemos misturados) foram avaliados de acordo com a morfologia interna pelo teste de raios X, na intensidade de 20 kV por 60 segundos de exposição. Posteriormente, as sementes radiografadas foram submetidas ao teste de germinação de modo a relacionar a morfologia interna das sementes com as respectivas plântulas normais, anormais ou sementes mortas. Após seis meses de armazenamento acondicionadas em sacos de papel Kraft, em condições não controladas de temperatura e umidade relativa do ar, amostras dessas sementes foram novamente avaliadas pelo teste de raios X. O teste de raios X é eficiente para avaliar a morfologia interna das sementes e seus reflexos no potencial fisiológico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-deformations caused by cyclic loading origins the variation of the distances between atoms of the crystal lattice producing the irreversible component. In order to study and understand the microstructural behavior of the material this paper investigated the influence suffered by residual stresses in thrust rolling bearing races fabricated in AISI 52100 steel, after tests by cyclic rolling contact in a tribometer at 1m/s under two contact pressures (500 MPa and 1400 MPa) in dry and boundary lubrication conditions. Procedures of tests thermo-acustically isolated were developed for monitoring the contact temperature and sound pressure level signals to establish a comparison between the residual stress measurements, micro-hardness Vickers and micrographic registers searching an indication of wear evolution. The sin²ψ method by X-ray diffraction technique was used to quantify the residual stresses. Three raceway zones were selected for the evaluation of wear and surface morphology after predetermined cycling, comparing with their new condition ("as received"). Micro-hardness and residual stress measurements showed significant changes after the tests and it was possible to observe the relationship between the increase of sound pressure level and the residual stress for dry and lubricated conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-deformations caused by cyclic loading origins the variation of the distances between atoms of the crystal lattice producing the irreversible component. In order to study and understand the microstructural behavior of the material this paper investigated the influence suffered by residual stresses in thrust rolling bearing races fabricated in AISI 52100 steel, after tests by cyclic rolling contact in a tribometer at 1m/s under two contact pressures (500 MPa and 1400 MPa) in dry and boundary lubrication conditions. Procedures of tests thermo-acustically isolated were developed for monitoring the contact temperature and sound pressure level signals to establish a comparison between the residual stress measurements, micro-hardness Vickers and micrographic registers searching an indication of wear evolution. The sin²ψ method by X-ray diffraction technique was used to quantify the residual stresses. Three raceway zones were selected for the evaluation of wear and surface morphology after predetermined cycling, comparing with their new condition ("as received"). Micro-hardness and residual stress measurements showed significant changes after the tests and it was possible to observe the relationship between the increase of sound pressure level and the residual stress for dry and lubricated conditions.