976 resultados para Flow rate variation coefficient


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experimental investigation was conducted to study the holdup distribution of oil and water two-phase flow in two parallel tubes with unequal tube diameter. Tests were performed using white oil (of viscosity 52 mPa s and density 860 kg/m(3)) and tap water as liquid phases at room temperature and atmospheric outlet pressure. Measurements were taken of water flow rates from 0.5 to 12.5 m(3)/h and input oil volume fractions from 3 to 94 %. Results showed that there were different flow pattern maps between the run and bypass tubes when oil-water two-phase flow is found in the parallel tubes. At low input fluid flow rates, a large deviation could be found on the average oil holdup between the bypass and the run tubes. However, with increased input oil fraction at constant water flow rate, the holdup at the bypass tube became close to that at the run tube. Furthermore, experimental data showed that there was no significant variation in flow pattern and holdup between the run and main tubes. In order to calculate the holdup in the form of segregated flow, the drift flux model has been used here.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A torch with a set of inter-electrode inserts between the cathode and the anode/nozzle with a wide nozzle exit was designed to generate plasma jets at chamber pressures of 500–10 000 Pa. The variation of the arc voltage was examined with the change in working parameters such as gas flow rate and chamber pressure. The fluctuation in the arc voltage was recorded with an oscilloscope, and the plasma jet fluctuation near the torch exit was observed with a high-speed video camera and detected with a double-electrostatic probe. Results show that the 300 Hz wave originated from the tri-phase rectified power supply was always detected under all generating conditions. Helmholtz oscillations over 3000 Hz was detected superposed on the 300 Hz wave at gas flow rates higher than 8.8 slm with a peak to valley amplitude lower than 5% of the average voltage value. No appreciable voltage fluctuation caused by the irregular arc root movement is detected, and mechanisms for the arc voltage and jet flow fluctuations are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on the mass balance equations of solute transfer in the radial chromatographic column, the theoretical expression to describe the column efficiency and shape of elution profile is obtained under linear isotherm case. Moreover, the tendency for the variation of column efficiency and symmetry of peak profile is systematically discussed. The results showed that in radial chromatography the relationship between the column efficiency and volumetric flow rate is similar with that relationship in axial chromatography; relatively high column efficiency still can be obtained under high flow rate in radial chromatography. Accompanying the increase of retention factor of solutes and injection time, the column efficiency decreases monotonously. The effect of column diameter and column length on the column efficiency interfere with each other. It is more advantageous to increase the column efficiency by applying columns with larger column diameter and shorter column length. According to the discussion of the effect of diffusion on the column efficiency, radial chromatography is proved to be suitable for the separation of samples with relatively high diffusion coefficient, which predicts its obvious advantage in the preparative separation of samples such as proteins and DNA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This note presents a simple model for prediction of liquid hold-up in two-phase horizontal pipe flow for the stratified roll wave (St+RW) flow regime. Liquid hold-up data for horizontal two-phase pipe flow [1, 2, 3, 4, 5 and 6] exhibit a steady increase with liquid velocity and a more dramatic fall with increasing gas rate as shown by Hand et al. [7 and 8] for example. In addition the liquid hold-up is reported to show an additional variation with pipe diameter. Generally, if the initial liquid rate for the no-gas flow condition gives a liquid height below the pipe centre line, the flow patterns pass successively through the stratified (St), stratified ripple (St+R), stratified roll wave, film plus droplet (F+D) and finally the annular (A+D, A+RW, A+BTS) regimes as the gas rate is increased. Hand et al. [7 and 8] have given a detailed description of this progression in flow regime development and definitions of the patterns involved. Despite the fact that there are over one hundred models which have been developed to predict liquid hold-up, none have been shown to be universally useful, while only a handful have proven to be applicable to specific flow regimes [9, 10, 11 and 12]. One of the most intractable regimes to predict has been the stratified roll wave pattern where the liquid hold-up shows the most dramatic change with gas flow rate. It has been suggested that the momentum balance-type models, which give both hold-up and pressure drop prediction, can predict universally for all flow regimes but particularly in the case of the difficult stratified roll wave pattern. Donnelly [1] recently demonstrated that the momentum balance models experienced some difficulties in the prediction of this regime. Without going into lengthy details, these models differ in the assumed friction factor or shear stress on the surfaces within the pipe particularly at the liquid–gas interface. The Baker–Jardine model [13] when tested against the 0.0454 m i.d. data of Nguyen [2] exhibited a wide scatter for both liquid hold-up and pressure drop as shown in Fig. 1. The Andritsos–Hanratty model [14] gave better prediction of pressure drop but a wide scatter for liquid hold-up estimation (cf. Fig. 2) when tested against the 0.0935 m i.d. data of Hand [5]. The Spedding–Hand model [15], shown in Fig. 3 against the data of Hand [5], gave improved performance but was still unsatisfactory with the prediction of hold-up for stratified-type flows. The MARS model of Grolman [6] gave better prediction of hold-up (cf. Fig. 4) but deterioration in the estimation of pressure drop when tested against the data of Nguyen [2]. Thus no method is available that will accurately predict liquid hold-up across the whole range of flow patterns but particularly for the stratified plus roll wavy regime. The position is particularly unfortunate since the stratified-type regimes are perhaps the most predominant pattern found in multiphase lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the concept of engine downsizing becomes ever more integrated into automotive powertrain development strategies, so too does the pressure on turbocharger manufacturers to deliver improvements in map width and a reduction in the mass flow rate at which compressor surge occurs. A consequence of this development is the increasing importance of recirculating flows, both in the impeller inlet and outlet domains, on stage performance.
The current study seeks to evaluate the impact of the inclusion of impeller inlet recirculation on a meanline centrifugal compressor design tool. Using a combination of extensive test data, single passage CFD predictions, and 1-D analysis it is demonstrated how the addition of inlet recirculation modelling impacts upon stage performance close to the surge line. It is also demonstrated that, in its current configuration, the accuracy of the 1-D model prediction diminishes significantly with increasing blade tip speed.
Having ascertained that the existing model requires further work, an evaluation of the vaneless diffuser modelling method currently employed within the existing 1-D model is undertaken. The comparison of the predicted static pressure recovery coefficient with test data demonstrated the inherent inadequacies in the resulting prediction, in terms of both magnitude and variation with flow rate. A simplified alternative method based on an equivalent friction coefficient is also presented that, with further development, could provide a significantly improved stage performance prediction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using data from the EISCAT (European Incoherent Scatter) VHF radar and DMSP (Defense Meteorological Satellite Program) spacecraft passes, we study the motion of the dayside open-closed field line boundary during two substorm cycles. The satellite data show that the motions of ion and electron temperature boundaries in EISCAT data, as reported by Moen et al. (2004), are not localised around the radar; rather, they reflect motions of the open-closed field line boundary at all MLT throughout the dayside auroral ionosphere. The boundary is shown to erode equatorward when the IMF points southward, consistent with the effect of magnetopause reconnection. During the substorm expansion and recovery phases, the dayside boundary returns poleward, whether the IMF points northward or southward. However, the poleward retreat was much faster during the substorm for which the IMF had returned to northward than for the substorm for which the IMF remained southward – even though the former substorm is much the weaker of the two. These poleward retreats are consistent with the destruction of open flux at the tail current sheet. Application of a new analysis of the peak ion energies at the equatorward edge of the cleft/cusp/mantle dispersion seen by the DMSP satellites identifies the dayside reconnection merging gap to extend in MLT from about 9.5 to 15.5 h for most of the interval. Analysis of the boundary motion, and of the convection velocities seen near the boundary by EISCAT, allows calculation of the reconnection rate (mapped down to the ionosphere) from the flow component normal to the boundary in its own rest frame. This reconnection rate is not, in general, significantly different from zero before 06:45 UT (MLT<9.5 h) – indicating that the X line footprint expands over the EISCAT field-of-view to earlier MLT only occasionally and briefly. Between 06:45 UT and 12:45UT (9.5rate variation shows considerable pulsing on timescales of 2–20 min during periods of steady southward IMF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The physical and chemical characteristics of peat were assessed through measurement of pH, percentage of organic matter, cationic exchange capacity (CEC), elemental analysis, infrared spectroscopy and quantitative analysis of metals by ICP OES. Despite the material showed to be very acid in view of the percentage of organic matter, its CEC was significant, showing potential for retention of metal ions. This characteristic was exploited by coupling a peat mini-column to a flow system based on the multicommutation approach for the in-line copper concentration prior to flame atomic absorption spectrometric determination. Cu(II) ions were adsorbed at pH 4.5 and eluted with 0.50 mol L(-1) HNO(3). The influence of chemical and hydrodynamic parameters, such as sample pH, buffer concentration, eluent type and concentration, sample flow-rate and preconcentration time were investigated. Under the optimized conditions, a linear response was observed between 16 and 100 mu g L(-1), with a detection limit estimated as 3 mu g L(-1) at the 99.7% confidence level and an enrichment factor of 16. The relative standard deviation was estimated as 3.3% (n = 20). The mini-column was used for at least 100 sampling cycles without significant variation in the analytical response. Recoveries from copper spiked to lake water or groundwater as well as concentrates used in hemodialysis were in the 97.3-111 % range. The results obtained for copper determination in these samples agreed with those achieved by graphite furnace atomic absorption spectrometry (GFAAS) at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The combined effect of scan speed, hydrogen and air flow rates on the flame ionization detection (FID) peak response of phospholipid classes has been studied to determine the optimum levels of these parameters. The phospholipid composition of different types of commercial lecithins, as well as lecithins combined with fish oils, has been analyzed by Iatroscan TLC‐FID Mark‐6s under optimized conditions. An air flow rate of 2 L/min, a hydrogen flow rate of 150–160 mL/min, and a scan speed of 30 s/rod seem to be the ideal conditions for scanning phospholipids with complete pyrolysis in the flame in the Mark‐6 model. Increasing the scan speed rapidly decreased the FID response. A hydrogen flow rate as high as 170 mL/min could be used at relatively low air flow rates (&#x003C2 L/min) and the response declined when both air flow rate and hydrogen flow rate increased simultaneously. Both linear and curvilinear relationships had highly significant correlations (p&#x003C0.01) with the sample load. Time course reactions, including the hydrolysis of phosphatidylserine using enzymes, can be successfully monitored by the Iatroscan TLC‐FID Chromarod system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The herbal medicine Sanativo® is produced by the Pernambucano Laboratory since 1888 with indications of healing and hemostasis. It is composed of a fluid extract about Piptadenia colubrina, Schinus terebinthifolius, Cereus peruvianus and Physalis angulata. Among the plants in their composition, S. terebinthifolius and P. colubrina have in common phenolic compounds which are assigned most of its pharmacological effects. The tannins, gallic acid and catechin were selected as markers for quality control. The aim of this study was the development and validation of analytical method by HPLC/UV/DAD for the separation and simultaneous quantification of gallic acid (GAC) and catechin (CTQ) in Sanativo®. The chromatographic system was to stationary phase, C-18 RP column, 4,6 x 150 mm (5 mm) under a temperature of 35 ° C, detection at 270 and 210 nm. The mobile phase consisted of 0.05% trifluoroacetic acid and methanol in the proportions 88:12 (v/v), a flow rate of 1 ml/min. The analytical method presented a retention factor of 0.30 and 1.36, tail factor of 1.8 and 1.63 for gallic acid and catechin, respectively, resolution of 18.2, and theoretical plates above 2000. The method validation parameters met the requirements of Resolution n º 899 of May 29, 2003, ANVISA. The correlation coefficient of linear regression analysis for GAC and CTQ from the standard solution was 0.9958 and 0.9973 and when performed from the Sanativo® 0.9973 and 0.9936, the matrix does not interfere in the range 70 to 110 %. The limits of detection and quantification for GAC and CQT were 3.25 and 0.863, and 9.57 and 2.55 mg/mL, respectively. The markers, GAC and CQT, showed repetibility (coefficient of variation of 0.94 % and 2.36 %) and satisfactory recovery (100.02 ± 1.11 % and 101.32 ± 1.36 %). The method has been characterized selective and robust quantification of GAC and CTQ in the Sanativo® and was considered validated

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a novel approach for the analysis of selected aldehydes (formaldehyde, acetaldehyde, propionaldehyde, and acrolein) and acetone in environmental samples using micellar electrokinetic chromatography (MEKC). The method is based on the reaction of carbonyl compounds with 3-methyl-2-benzothiazoline hydrazone (MBTH) that gives an azine intermediate with maximum absorbance at 216 nm. A systematic evaluation of sample dissolution medium was conducted as a means to enhancing sensitivity. In the best condition, samples were dissolved in 0.030 mol.L-1 tetraborate solution. This condition presented enhancement factors in the range of 35-54 for the aldehydes under investigation, computed as the improvement of the concentration limits of detection (LODs) with reference to the sample dissolved in pure water. The running buffer was 0.020 mol.L-1 tetraborate, pH 9.3, containing 0.050 mol-L-1 sodium dodecyly sulfate (SIDS). The overall methodology presented several advantages over established methods for aldehydes. Worthy mentioning that MBTH is available in high purity degree, dispensing laborious reagent purification procedures. A few method validation parameters were determined revealing good migration time repeatability (< 2.5% coefficient of variation, CV) and area repeatability (< 4% CV), excellent linearity (20-120 mug/L, r > 0.995) and adequate sensitivity for environmental applications. The LODs with respect to each single aldehyde were in the range of 0.54-4.0 mug.L-1 and 11 mug.L-1 for acetone. The methodology was applied to the determination of aldehydes indoors. Samples were collected in an impinger flask containing 0.05% MBTH solution, at a flow rate of 0.80 L.min(-1), during 2.5 h, at different times during the day. The most abundant carbonyls in the samples were acetone, followed by formaldehyde and acetaldehyde, with estimate peak concentrations of 452, 5.2 and 2.2 ppbv, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport equation coupled with momentum and energy equations. Time variations of pressure, tangential velocity of the rolling piston and radial clearance due to pump setting have been included in the mixture flow model. Those variables have been obtained by modeling the compression process, rolling piston dynamics and by using geometric characteristics of the pump, respectively. An important conclusion concerning this work is the large variation of refrigerant concentration in the oil-filled radial clearance during the compression cycle. That is particularly true for large values of mass flow rates, and for those cases the flow mixture cannot be considered as having uniform concentration. In presence of low mass flow rates homogeneous flow prevail and the mixture tend to have a uniform concentration. In general, it was observed that for calculating the refrigerant mass flow rate using the difference in refrigerant concentration between compression and suction chambers, a time average value for the gas concentration should be used at the clearance inlet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a fabrication and test sequence of microvalves installed on micronozzles. The technique used to fabricate the micronozzles was powder blasting. The microvalves are actuators made from PVDF (polivinylidene fluoride), that is a piezoelectric polymer. The micronozzles have convergent-divergent shape with external diameter of 1mm and throat around 230μm. The polymer have low piezoelectric coefficient, for this reason a bimorph structure with dimensions of 2mm width and 4mm of length was build (two piezoelectric sheets were glued together with opposite polarization). Both sheets are recovered with a conductor thin film used as electrodes. Applying a voltage between the electrodes one sheet expands while the other contracts and this generate a vertical movement to the entire actuator. Appling +300V DC between the electrodes the volume flux rate, for a pressure ratio of 0.5, was 0.36 sccm. Applying -200V DC between the electrodes (that means it closed) the volume flux rate was 0.32 sccm, defining a possible range of flow between 0.32 and 0.36 sccm. The third measurement was performed using AC voltage (200V AC with frequency of 1Hz), where the actuator was oscillating. For pressure ratio of 0.5, the flow rate was 0.62 sccm. © 2008 IOP Publishing Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The objective of this study was to develop a model to design longer lateral lines using non-pressure compensating drip hose. Using the developed model, the hypotheses to be evaluated were: a) the use of two different spacing between emitters in the same lateral line allows longer length; b) it is possible to get longer lateral lines using high values of pressure variation in the lateral lines since the distribution uniformity stays below allowable limits. A computer program was developed in Delphi based on the model developed and it is able to design lateral lines in level using non-pressure compensating drip hose. The input data are: desired distribution uniformity (DU); initial and final pressure in the lateral line; coefficients of relationship between emitter discharge and pressure head; hose internal diameter; pipe cross-sectional area with the dripper; and roughness coefficient for the Hazen-Williams equation. The program allows calculate the lateral line length with three possibilities: selecting two spacing between emitters and defining the exchange point; using two pre-established spacing between emitters and calculating the length of each section with different spacing; using one emitter spacing. Results showed that the use of two sections with different spacing between drippers in the lateral line didn't allow longer length but got better uniformity when compared with lateral line with one spacing between emitters. The adoption of two spacing increased the flow rate per meter in the final section which represented approximately 80% of the lateral line total length and this justifies their use. The software allowed DU above 90% with pressure head variation of 40% and the use of two spacing between emitters. The developed model/software showed to be accurate, easy to handle and useful for lateral line design using non-pressure compensating drip hose.