980 resultados para Fixed resin bonded partial denture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare and to evaluate the stability of the retentive force of cobalt-chromium (Co-Cr) circumferential clasps (control) to those with an acetyl resin retentive arm. METHODS: Sixteen specimens with a couple of circumferential clasps were made using Co-Cr over a metal model providing 0.25 mm undercuts. Eight specimens were fabricated without the anterior retentive arm, which was made later using acetyl resin (Dental D). Insertion and removal simulation test was performed through 7250 cycles. The retentive force was recorded in Newtons (N) for periods corresponding to 0, 1, 2, 3, 4, and 5 years. The data were subjected to ANOVA and Tukey test to compare periods and to Student's t test to compare groups (α=0.05). RESULTS: Mean (SD) is presented for Co-Cr and resin groups, respectively: 8.09(3.05) and 2.79(1.57) in period 0; 10.48(4.25) and 3.32(1.92) in 1 year; 10.09(4.15) and 3.47(1.81) in 2 years; 9.87(4.30) and 3.46(1.87) in 3 years; 9.46(3.93) and 3.27(1.59) in 4 years; 9.63(3.79) and 3.41(1.59) in 5 years. There were significant differences for Co-Cr between periods of 0 and 1 (p<0.001), 0 and 2 (p<0.01) and 0 and 3 (p<0.05). In the resin group, no significant differences were found between periods (p>0.05). Comparisons between the groups showed statistical differences for all tested periods: 0 (p=0.0012), 1 (p=0.0013), 2 (p=0.0019), 3 (p=0.0031), 4 (p=0.0027) and 5 years (p=0.0014). CONCLUSIONS: Acetyl resin retentive arms, even if only in the anterior clasps, can significantly reduce the retentive force, but this force remained stable after 5 years of simulated use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O uso dos magnetos em prótese parcial removível é uma alternativa viável para eliminar a estrutura metálica que pode interferir na estética sem perder retenção e estabilidade. Os magnetos podem ser recomendados para pacientes com perda de tecido periodontal, desde que eles diminuam a transmissão de forças ao dente remanescente. O objetivo deste relato de caso clínico foi apresentar uma alternativa de tratamento protético para dentes pilares comprometidos periodontalmente e descrever as vantagens e desvantagens do uso dos magnetos em prótese parcial removível sobre os pontos de vista funcionais, biológicos e estéticos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Replacement of maxillary front teeth with a fixed, implant supported partial denture with a high laugh line is a demanding procedure. For an optimal esthetic result, no deficiency of bone or soft tissue is acceptable. Submerged implant healing has often been recommended for better predictability in esthetically demanding situations. This case report shows the rehabilitation with a fixed implant supported reconstruction in the upper front and a single implant supported crown in the premolar region. Teeth had to be extracted because of apical lesions, periodontal the gingiva. The technique of delayed, submerged implant placement in the region of 11, 21 and 22 was applied and in the region of 15 a transmucosal implant healing. With a fixed, implant supported partial denture the mucosa in the upper front was conditioned. Ten months after implantation the definitive screwed, fixed partial denture on SPI ELEMENT implants was successfully integrated. In the region 15 a single crown transversally screwed was fixed on a SPI ONE TIME implant. Radiographic data two years after implantation showed a well established periimplant crestal bone level. No prosthetic complications had occurred since the insertion of the reconstruction twelve months ago.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’objectif de cette étude était d’évaluer et de comparer la force d’adhésion de deux résines de collage: le ClearfilTM Esthetic Cement & DC Bond Kit (C) et le RelyXTM Unicem (R), sur trois adhérents différents : une surface d’émail, un alliage de métaux non précieux (Np) et un alliage de métaux semi-précieux (Sp). La surface des échantillons des alliages métalliques a subi différents traitements de surface. Sur l’émail (n=15) ainsi que sur les plaquettes d’alliages Np et Sp (n=15), des cylindres de résine étaient appliqués et polymérisés. Suite au processus de collage, les échantillons ont été incubés à 37°C pendant 24 heures, puis ont subi 500 cycles de thermocyclage. Des tests de cisaillement ont été effectués, suivi par l’analyse de la surface des échantillons au microscope à balayage électronique. Une comparaison de type T-test et des comparaisons multiples post hoc, ont été effectuées pour l’analyse statistique (p 0,05). Sur l’émail, les résultats ont démontré que la résine C présentait une force d'adhésion moyenne statistiquement supérieure (33,97±17,18 MPa) à la résine R (10,48±11,23 MPa) (p 0,05). Le type d’alliage utilisé n’influençait pas la force d’adhésion, et ce, peu importe le type de résine de collage (p>0,05). Pour le groupe Sp, la résine C a démontré une adhésion statistiquement supérieure à la résine R, et ce, pour tous les traitements de surface (p 0,05). En conclusion, la résine C a démontré des résultats d’adhésion significativement supérieurs à la résine R sur l’émail ainsi que sur presque toutes les surfaces traitées des alliages de métaux.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the effect of metal conditioners on the bond strength between resin cements and cast titanium. Method and Materials: Commercially pure titanium (99.56%) was cast using an arc casting machine. Surfaces were finished with 400-grit silicon carbide paper followed by air abrasion with 50-mu m aluminum oxide. A piece of double-coated tape with a 4-mm circular hole was then positioned on the metal surface to control the area of the bond. The prepared surfaces were then divided into 4 groups (n=10): G1, unprimed Panavia F; G2, Alloy Primer-Panavia F; G3, unprimed Bistite DC; G4, Metaltite-Bistite DC. Forty minutes after insertion of the resin cements, the specimens were detached from the mold and stored in water at 37 C for 24 hours. Shear bond strength was performed in a testing machine (MTS 810) at a crosshead speed of 0.5 mm/min. Data were analyzed using ANOVA and Tukey's test with a .05 significance level. The fractured surfaces were observed through an optical microscope at 10x magnification. Results: the G1 group demonstrated significantly higher shear bond strength (17.95 MPa) than the other groups. G3 (13.79 MPa) and G4 (12.98 MPa) showed similar mean values to each other and were statistically superior to G2 (9.31 MPa). Debonded surfaces generally presented adhesive failure between metal surfaces and resin cements. Conclusion: While the Metaltite conditioner did not influence the bond strength of the Bistite DC cement, the Alloy Primer conditioner significantly decreased the mean bond strength of the Panavia F cement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This investigation studied the effects of 3 surface treatments on the shear bond strength of a light-activated composite resin bonded to acrylic resin denture teeth. Materials and Methods: The occlusal surfaces of 30 acrylic resin denture teeth were ground flat with up to 400-grit silicon carbide paper. Three different surface treatments were evaluated: (1) the flat ground surfaces were primed with methyl methacrylate (MMA) monomer for 180 seconds; (2) light-cured adhesive resin was applied and light polymerized according to the manufacturer's instructions; and (3) treatment 1 followed by treatment 2. The composite resin was packed on the prepared surfaces using a split mold. The interface between tooth and composite was loaded at a cross-head speed of 0.5 mm/min until failure. Results: Analysis of variance indicated significant differences between the surface treatments. Results of mean comparisons using Tukey's test showed that significantly higher shear bond strengths were developed by bonding composite resin to the surfaces that were previously treated with MMA and then with the bonding agent when compared to the other treatments. Conclusion: Combined surface treatment of MMA monomer followed by application of light-cured adhesive resin provided the highest shear bond strength between composite resin and acrylic resin denture teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success rate of resin-bonded fixed partial dentures is directly related to the adhesive system and the tooth preparation design for good retention. These resin-bonded bridges represent a prosthodontic alternative, based on their costeffectiveness, conservative techniques, and ease of laboratory manufacturing. Through a thorough review of the literature, this study aimed to report on cavity designs, types of materials used, and the advantages and disadvantages of the resin-bonded fixed partial denture. One of significant advantages of the resin-bonded fixed partial dentures is the conservation of the tooth structure, whereas its main disadvantage includes aesthetic limitations, given that the alloy may in fact be visible. Preparation design, cement type, and casting alloy type, as well as surface treatment, are among the factors that influence the longevity of resin-bonded fixed partial dentures. Treatments with resin-bonded fixed partial dentures present a bright outlook regarding the conservation of tooth structures, as well as a high level of success.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The indications for direct resin composite restorations are nowadays extended due to the development of modern resin materials with improved material properties. However, there are still some difficulties regarding handling of resin composite material, especially in large restorations. The reconstruction of a functional and individual occlusion is difficult to achieve with direct application techniques. The aim of the present publication was to introduce a new "stamp"-technique for placing large composite restorations. The procedure of this "stamp"-technique is presented by three typical indications: large single-tooth restoration, occlusal rehabilitation of a compromised occlusal surface due to erosions and direct fibre-reinforced fixed partial denture. A step-by-step description of the technique and clinical figures illustrates the method. Large single-tooth restorations can be built-up with individual, two- piece silicone stamps. Large occlusal abrasive and/or erosive defects can be restored by copying the wax-up from the dental technician using the "stamp"-technique. Even fiber-reinforced resin-bonded fixed partial dentures can be formed with this intraoral technique with more precision and within a shorter treatment time. The presented "stamp"-technique facilitates the placement of large restoration with composite and can be recommended for the clinical use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to compare two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the shortened dental arch (SDA) and conventional treatment using removable partial dentures (RPDs) using a randomised controlled clinical trial. The primary outcome measure for this study was impact on oral health-related quality of life (OHRQoL) measured using the short form of the oral health impact profile (OHIP-14).

METHODS: Patients aged 65 years and older were randomly allocated to two different treatment groups: the RPD group and the SDA group. For the RPD group each patient was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. For the SDA group, patients were restored to a premolar occlusion of 10 occluding pairs of natural and replacement teeth using resin bonded bridgework (RBB). OHRQoL was measured using the OHIP-14 questionnaire administered at baseline, 1 month, 6 months and 12 months after treatment intervention.

RESULTS: In total, 89 patients completed the RCT: 44 from the RPD group and 45 from the SDA group. Analysis using a mixed model of covariance (ANCOVA) illustrated that treatment according to the SDA concept resulted in significantly better mean OHIP-14 scores compared with RPD treatment (p<0.05). This result was replicated in both treatment centres used in the study.

CONCLUSIONS: In terms of impact on OHRQoL, treatment based on the SDA concept achieved significantly better results than that based on RPDs 12 months after treatment intervention (trial registration no. ISRCTN26302774).

CLINICAL SIGNIFICANCE: Functionally orientated treatment delivery resulted in significantly better outcomes compared to removable dentures in terms of impact on OHRQoL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare the cost-effectiveness of conventional treatment using partial dentures with functionally orientated treatment to replace missing teeth for partially dentate elders using a randomised controlled clinical trial.

BACKGROUND: In many countries, including the Republic of Ireland, the only publically funded treatment option offered to partially dentate older patients is a removable partial denture. However, evidence suggests that these removable prostheses are unpopular with patients and can potentially increase the risk of further dental disease and subsequent tooth loss.

MATERIALS AND METHODS: Fourty-four partially dentate patients aged 65 years and older were recruited. Patients were randomly assigned to the two treatment arms of the study. The conventional treatment group received removable partial dentures to replace all missing natural teeth. The functionally orientated group was restored to a Shortened Dental Arch (SDA) of 10 occluding contacts using resin-bonded bridgework (RBB). The costs associated with each treatment were recorded. Effectiveness was measured in terms of the impact on oral health-related quality of life (OHRQoL) using OHIP-14.

RESULTS: Both groups reported improvements in OHRQoL 1 month after completion of treatment. The conventional treatment group required 8.3 clinic visits as compared to 4.4 visits for the functionally orientated group. The mean total treatment time was 183 min 19 s for the conventional group vs. 124 min 8 s for the functionally orientated group. The average cost of treatment for the conventional group was 487.74 Euros compared to 356.20 Euros for the functional group.

CONCLUSIONS: Functionally orientated treatment was more cost-effective than conventional treatment in terms of treatment effect and opportunity costs to the patients' time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study aimed to compare the cost effectiveness of conventional treatment using partial dentures with functionally-orientated treatment based on the shortened dental arch concept to replace missing teeth for partially dentate elders.
Methods: 44 partially dentate patients aged 65 years and older were recruited following routine dental assessment at a university dental hospital. Patients consented to and were randomly assigned to the two treatment arms. The conventional treatment group received a removable partial denture to replace all missing natural teeth. The functionally-orientated group were restored to a shortened dental arch of 10 occluding contacts using resin bonded bridgework. The costs associated with each treatment were recorded including laboratory charges, treatment time and opportunity costs. The impact on quality of life (OHRQoL) was measured using the 14-item Oral Health Impact Profile.
Results: Both groups reported improvements in OHRQoL after completion of treatment. For the conventional group, the mean OHIP-14 score decreased from 12.4 pre-operatively to 3.3 post-operatively (p<0.001). In the functionally-orientated group the OHIP-14 score decreased from 11.4 to 1.8 following treatment (p<0.001). On average the conventional treatment group required 8.3 clinic visits as compared to 4.4 visits for the functionally-orientated group. The mean total treatment time was 183 minutes 19 seconds for the conventional group versus 124 minutes 8 seconds for the functionally-orientated group. The conventional treatment group had an average of 6.33 teeth replaced at a laboratory cost of 337.31 Euros. The functionally-orientated group had an average of 2.64 teeth replaced at a laboratory cost of 244.05 Euros.
Conclusions: Restoration to a shortened dental arch using functionally-orientated treatment resulted in a similar improvement in OHRQoL with fewer clinic visits, less operative time and at a lower laboratory cost compared with conventional treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)