919 resultados para Field evaluation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the development of an Advanced Speech Communication System for Deaf People and its field evaluation in a real application domain: the renewal of Driver’s License. The system is composed of two modules. The first one is a Spanish into Spanish Sign Language (LSE: Lengua de Signos Española) translation module made up of a speech recognizer, a natural language translator (for converting a word sequence into a sequence of signs), and a 3D avatar animation module (for playing back the signs). The second module is a Spoken Spanish generator from sign-writing composed of a visual interface (for specifying a sequence of signs), a language translator (for generating the sequence of words in Spanish), and finally, a text to speech converter. For language translation, the system integrates three technologies: an example-based strategy, a rule-based translation method and a statistical translator. This paper also includes a detailed description of the evaluation carried out in the Local Traffic Office in the city of Toledo (Spain) involving real government employees and deaf people. This evaluation includes objective measurements from the system and subjective information from questionnaires. Finally, the paper reports an analysis of the main problems and a discussion about possible solutions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several issues concerning the current use of speech interfaces are discussed and the design and development of a speech interface that enables air traffic controllers to command and control their terminals by voice is presented. A special emphasis is made in the comparison between laboratory experiments and field experiments in which a set of ergonomics-related effects are detected that cannot be observed in the controlled laboratory experiments. The paper presents both objective and subjective performance obtained in field evaluation of the system with student controllers at an air traffic control (ATC) training facility. The system exhibits high word recognition test rates (0.4% error in Spanish and 1.5% in English) and low command error (6% error in Spanish and 10.6% error in English in the field tests). Subjective impression has also been positive, encouraging future development and integration phases in the Spanish ATC terminals designed by Aeropuertos Españoles y Navegación Aérea (AENA).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes the application of language translation technologies for generating bus information in Spanish Sign Language (LSE: Lengua de Signos Española). In this work, two main systems have been developed: the first for translating text messages from information panels and the second for translating spoken Spanish into natural conversations at the information point of the bus company. Both systems are made up of a natural language translator (for converting a word sentence into a sequence of LSE signs), and a 3D avatar animation module (for playing back the signs). For the natural language translator, two technological approaches have been analyzed and integrated: an example-based strategy and a statistical translator. When translating spoken utterances, it is also necessary to incorporate a speech recognizer for decoding the spoken utterance into a word sequence, prior to the language translation module. This paper includes a detailed description of the field evaluation carried out in this domain. This evaluation has been carried out at the customer information office in Madrid involving both real bus company employees and deaf people. The evaluation includes objective measurements from the system and information from questionnaires. In the field evaluation, the whole translation presents an SER (Sign Error Rate) of less than 10% and a BLEU greater than 90%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A methodology for developing an advanced communications system for the Deaf in a new domain is presented in this paper. This methodology is a user-centred design approach consisting of four main steps: requirement analysis, parallel corpus generation, technology adaptation to the new domain, and finally, system evaluation. During the requirement analysis, both the user and technical requirements are evaluated and defined. For generating the parallel corpus, it is necessary to collect Spanish sentences in the new domain and translate them into LSE (Lengua de Signos Española: Spanish Sign Language). LSE is represented by glosses and using video recordings. This corpus is used for training the two main modules of the advanced communications system to the new domain: the spoken Spanish into the LSE translation module and the Spanish generation from the LSE module. The main aspects to be generated are the vocabularies for both languages (Spanish words and signs), and the knowledge for translating in both directions. Finally, the field evaluation is carried out with deaf people using the advanced communications system to interact with hearing people in several scenarios. In this evaluation, the paper proposes several objective and subjective measurements for evaluating the performance. In this paper, the new considered domain is about dialogues in a hotel reception. Using this methodology, the system was developed in several months, obtaining very good performance: good translation rates (10% Sign Error Rate) with small processing times, allowing face-to-face dialogues.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Em busca de soluções estruturais para restauração de pavimentos rodoviários que que sejam eficientes, mas ao mesmo tempo que sejam econômicas e impactem o mínimo possível na dinâmica de operação da malha rodoviária, tem sido difundida a metodologia de reciclagem a frio de pavimentos com a estabilização com espuma de asfalto. A redução de custos devido a reutilização de material e a menor necessidade de transporte de insumos, além da possibilidade de realização da restauração em um curto espaço de tempo, têm contribuído para a crescente utilização do processo. Este trabalho tem como objetivo avaliar o desempenho e o comportamento mecânico de uma mistura reciclada estabilizada com espuma asfalto, para melhor entender os efeitos do confinamento e do teor de umidade do material, visto que este passa por um processo de cura quando já em serviço. Foi acompanhado um trecho experimental onde o pavimento foi restaurado com a aplicação de uma base reciclada estabilizada com espuma de asfalto. O segmento foi monitorado através do controle tecnológico de execução e de levantamentos deflectométricos com FWD. Verificou-se que as deflexões após quase 24 meses da execução do trecho reduziram consideravelmente. Paralelamente, foram realizados ensaios de resistência à tração por compressão diametral, módulo de resiliência triaxial e de deformação permanente para diferentes procedimentos de cura para verificação do efeito da saída da água nas mudanças de comportamento mecânico do material. Verificou-se ainda o efeito das tensões de confinamento no módulo de resiliência de materiais estabilizados com espuma de asfalto e determinaram-se os parâmetros de cisalhamento do material através de ensaiosTriaxiais Monotônicos. Pode-se concluir que a cura é uma consideração importante tanto com relação a sua duração, quanto com relação ao seu efeito no comportamento do material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2016.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this paper is to aid researchers in selecting appropriate qualitative methods in order to develop and improve future studies in the field of emotional design. These include observations, think-aloud protocols, questionnaires, diaries and interviews. Based on the authors’ experiences, it is proposed that the methods under review can be successfully used for collecting data on emotional responses to evaluate user product relationships. This paper reviews the methods; discusses the suitability, advantages and challenges in relation to design and emotion studies. Furthermore, the paper outlines the potential impact of technology on the application of these methods, discusses the implications of these methods for emotion research and concludes with recommendations for future work in this area.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When performances are evaluated they are very often presented in a sequential order. Previous research suggests that the sequential presentation of alternatives may induce systematic biases in the way performances are evaluated. Such a phenomenon has been scarcely studied in economics. Using a large dataset of performance evaluation in the Idol series (N=1522), this paper presents new evidence about the systematic biases in sequential evaluation of performances and the psychological phenomena at the origin of these biases.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background The onsite treatment of sewage and effluent disposal within the premises is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the seemingly low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. Therefore it is important that careful consideration is given to the design and location of onsite sewage treatment systems. It requires an understanding of the factors that influence treatment performance. The use of subsurface effluent absorption systems is the most common form of effluent disposal for onsite sewage treatment and particularly for septic tanks. Additionally in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Therefore location specific factors will play a key role in this context. The project The primary aims of the research project are: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to identify important areas where there is currently a lack of relevant research knowledge and is in need of further investigation. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of the research project has been on septic tanks. Therefore by implication the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. In the evaluation to be undertaken, the treatment performance of soil absorption systems will be related to the physico-chemical characteristics of the soil. Five broad categories of soil types have been considered for this purpose. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each soil types. In the initial phase of the investigation, though the majority of the systems evaluated were septic tanks, a small number of aerobic wastewater treatment systems (AWTS) were also included. This was primarily to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of different types of systems investigated was relatively small. As such this does not permit a statistical analysis to be undertaken of the results obtained. This is an important issue considering the large number of parameters that can influence treatment performance and their wide variability. The report This report is the second in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The work undertaken included site investigation and testing of sewage effluent and soil samples taken at distances of 1 and 3 m from the effluent disposal area. The project component discussed in the current report formed the basis for the more detailed investigation undertaken subsequently. The outcomes from the initial studies have been discussed, which enabled the identification of factors to be investigated further. Primarily, this report contains the results of the field monitoring program, the initial analysis undertaken and preliminary conclusions. Field study and outcomes Initially commencing with a list of 252 locations in 17 different suburbs, a total of 22 sites in 21 different locations were monitored. These sites were selected based on predetermined criteria. To obtain house owner agreement to participate in the monitoring study was not an easy task. Six of these sites had to be abandoned subsequently due to various reasons. The remaining sites included eight septic systems with subsurface effluent disposal and treating blackwater or combined black and greywater, two sites treating greywater only and six sites with AWTS. In addition to collecting effluent and soil samples from each site, a detailed field investigation including a series of house owner interviews were also undertaken. Significant observations were made during the field investigations. In addition to site specific observations, the general observations include the following: • Most house owners are unaware of the need for regular maintenance. Sludge removal has not been undertaken in any of the septic tanks monitored. Even in the case of aerated wastewater treatment systems, the regular inspections by the supplier is confined only to the treatment system and does not include the effluent disposal system. This is not a satisfactory situation as the investigations revealed. • In the case of separate greywater systems, only one site had a suitably functioning disposal arrangement. The general practice is to employ a garden hose to siphon the greywater for use in surface irrigation of the garden. • In most sites, the soil profile showed significant lateral percolation of effluent. As such, the flow of effluent to surface water bodies is a distinct possibility. • The need to investigate the subsurface condition to a depth greater than what is required for the standard percolation test was clearly evident. On occasion, seemingly permeable soil was found to have an underlying impermeable soil layer or vice versa. The important outcomes from the testing program include the following: • Though effluent treatment is influenced by the physico-chemical characteristics of the soil, it was not possible to distinguish between the treatment performance of different soil types. This leads to the hypothesis that effluent renovation is significantly influenced by the combination of various physico-chemical parameters rather than single parameters. This would make the processes involved strongly site specific. • Generally the improvement in effluent quality appears to take place only within the initial 1 m of travel and without any appreciable improvement thereafter. This relates only to the degree of improvement obtained and does not imply that this quality is satisfactory. This calls into question the value of adopting setback distances from sensitive water bodies. • Use of AWTS for sewage treatment may provide effluent of higher quality suitable for surface disposal. However on the whole, after a 1-3 m of travel through the subsurface, it was not possible to distinguish any significant differences in quality between those originating from septic tanks and AWTS. • In comparison with effluent quality from a conventional wastewater treatment plant, most systems were found to perform satisfactorily with regards to Total Nitrogen. The success rate was much lower in the case of faecal coliforms. However it is important to note that five of the systems exhibited problems with regards to effluent disposal, resulting in surface flow. This could lead to possible contamination of surface water courses. • The ratio of TDS to EC is about 0.42 whilst the optimum recommended value for use of treated effluent for irrigation should be about 0.64. This would mean a higher salt content in the effluent than what is advisable for use in irrigation. A consequence of this would be the accumulation of salts to a concentration harmful to crops or the landscape unless adequate leaching is present. These relatively high EC values are present even in the case of AWTS where surface irrigation of effluent is being undertaken. However it is important to note that this is not an artefact of the treatment process but rather an indication of the quality of the wastewater generated in the household. This clearly indicates the need for further research to evaluate the suitability of various soil types for the surface irrigation of effluent where the TDS/EC ratio is less than 0.64. • Effluent percolating through the subsurface absorption field may travel in the form of dilute pulses. As such the effluent will move through the soil profile forming fronts of elevated parameter levels. • The downward flow of effluent and leaching of the soil profile is evident in the case of podsolic, lithosol and kransozem soils. Lateral flow of effluent is evident in the case of prairie soils. Gleyed podsolic soils indicate poor drainage and ponding of effluent. In the current phase of the research project, a number of chemical indicators such as EC, pH and chloride concentration were employed as indicators to investigate the extent of effluent flow and to understand how soil renovates effluent. The soil profile, especially texture, structure and moisture regime was examined more in an engineering sense to determine the effect of movement of water into and through the soil. However it is not only the physical characteristics, but the chemical characteristics of the soil also play a key role in the effluent renovation process. Therefore in order to understand the complex processes taking place in a subsurface effluent disposal area, it is important that the identified influential parameters are evaluated using soil chemical concepts. Consequently the primary focus of the next phase of the research project will be to identify linkages between various important parameters. The research thus envisaged will help to develop robust criteria for evaluating the performance of subsurface disposal systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper illustrates a field research performed with a team of experts involved in the evaluation of Trippple, a system aimed at supporting the different phases of a tourist trip, in order to provide feedback and insights, both on the functionalities already implemented (that at the time of evaluation were available only as early and very unstable prototypes), and on the functionalities still to be implemented. We show how the involvement of professionals helped to focus on challenging aspects, instead of less important, cosmetic, issues and resulted profitable in terms of early feedback, issues spotted, and improvements suggested

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Effective Quality of Experience (QoE) management for mobile video delivery – to optimize overall user experience while adapting to heterogeneous use contexts – is still a big challenge to date. This paper proposes a mobile video delivery system to emphasize the use of acceptability as the main indicator of QoE to manage the end-to-end factors in delivering mobile video services. The first contribution is a novel framework for user-centric mobile video system that is based on acceptability-based QoE (A-QoE) prediction models, which were derived from comprehensive subjective studies. The second contribution is results from a field study that evaluates the user experience of the proposed system during realistic usage circumstances, addressing the impacts of perceived video quality, loading speed, interest in content, viewing locations, network bandwidth, display devices, and different video coding approaches, including region-of-interest (ROI) enhancement and center zooming

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Results from the first of two artificially inoculated field experiments showed foliar applications of copper hydroxide (Blue Shield Copper) at 600 g a.i./100 L−1 (0% infected fruit), copper hydroxide + metalaxyl-M (Ridomil Gold Plus.) at 877.5 g a.i./100 L−1 (0.27%), metiram + pyraclostrobin (Aero) at 720 g a.i./100 L−1 (0.51%), chlorothalonil (Bravo WeatherStik) at 994 g a.i./100 L−1 (0.63%) and cuprous oxide (Nordox 750 WG) at 990 g a.i./100 L−1 (0.8%) of water significantly reduced the percentage of infected fruit compared to potassium phosphonate (Agri-Fos 600) at 1200 g a.i./100 L−1 (8.22%), dimethomorph (Acrobat) at 108 g a.i./100 L−1 (11.18%) and the untreated control (16%). Results from the second experiment showed fruit sprayed with copper hydroxide (Champ Dry Prill) at 300 (2.0% infected fruit), 375 (0.4%) and 450 g a.i./100 L−1 (0.6%) and metiram + pyraclostrobin (Aero) at 360 (2.8%), 480 (0.6%) and 600 g a.i./100 L−1 of water (1.0%) significantly reduced the percentage of infected fruit compared to the untreated control (19.4%). Foliar sprays of copper hydroxide at 375 g a.i./100 L−1 in rotation with chlorothalonil at 994 g a.i./100 L−1 every two weeks is now recommended to growers for controlling Phytophthora fruit rot of papaya.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have evaluated techniques of estimating animal density through direct counts using line transects during 1988-92 in the tropical deciduous forests of Mudumalai Sanctuary in southern India for four species of large herbivorous mammals, namely, chital (Axis axis), sambar (Cervus unicolor), Asian elephant (Elephas maximus) and gaur (Bos gauras). Density estimates derived from the Fourier Series and the Half-Normal models consistently had the lowest coefficient of variation. These two models also generated similar mean density estimates. For the Fourier Series estimator, appropriate cut-off widths for analysing line transect data for the four species are suggested. Grouping data into various distance classes did not produce any appreciable differences in estimates of mean density or their variances, although model fit is generally better when data are placed in fewer groups. The sampling effort needed to achieve a desired precision (coefficient of variation) in the density estimate is derived. A sampling effort of 800 km of transects returned a 10% coefficient of variation on estimate for chital; for the other species a higher effort was needed to achieve this level of precision. There was no statistically significant relationship between detectability of a group and the size of the group for any species. Density estimates along roads were generally significantly different from those in the interior af the forest, indicating that road-side counts may not be appropriate for most species.