986 resultados para Feeder reconfiguration of distribution systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic reconfiguration has been listed as one of the key challenges in support of agent adaptation to environments, which has attracted much attention of researchers world wide. To tackle this tough problem, an agent-based dynamic reconfiguration model (ADRM) is proposed from the autonomy-oriented computing (AOC) point of view. The ERA (environment-reactive rules-agents) algorithm used in AOC is improved to support the organization formation behavior, which is essential in dynamic reconfiguration. To test the efficiency of this model and the effectiveness of different reactive behaviors, the performance of this model was investigated under different selection probabilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Excellence in Research for Australia (ERA) initiative being conducted by the Australian Research Council (ARC), mandates a single journal and conference ranking scheme over every academic discipline in Australia. A universal publication outlet ranking list mandated by a government agency is unique and has attracted interest and comment both within Australia and overseas. Equally, the interest shown has come from all sectors involved in academic publishing – authors, reviewers, publishers – and from commercial and open access publishers. This paper investigates the distribution of information systems journals over the various ERA parameters and comments on a claim of bias whereby the ranking of a journal is positively influenced by the number of years it has been in existence in the areas of information systems and business journals. Clear evidence of the diversity of the information systems discipline is observed. The benefits of a multidisciplinary foundation for information systems is also noted. Longer established journals are shown to attract higher rankings and possible reasons for and implications flowing from this are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of drinking water generally degrades when it is delivered through a distribution system due to the decay of disinfectant, which subsequently allows the re-growth of microorganisms in the distribution system. A model that describes the changes that occur in the water quality in distribution system is needed to determine whether to enhance the treatment processes or to improve the distribution system so that microbiological criteria are met. This paper describes how chlorine decay kinetics are modeled and the model output is used in finding the elements that are contributing to the consumption of chlorine at the treatment plant other than the water itself; this allows better control of chlorine dosing at the treatment plant, which in tum will reduce the formation of disinfectant by-products. In addition, the model will accurately predict the decay due to the organic/inorganic and nitrogenous compounds that are remaining in the water at any point in the distribution system, which will indicate the status of the distribution system with respect to its chlorine consumption. Further, if re-chlorination is introduced in the distribution system downstream of the treatment plant, the model will predict the chlorine decay due to the slow reacting organic and nitrogenous compounds accurately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The decay of chlorine in drinking water involves a complex set of reactions that is usually simplified to first order kinetics in models of water quality in distribution systems. However, to be useful in optimising chlorine dosing regimes, the kinetics expression should accurately describe the shape of the chlorine decay curve for different chlorine doses and be able to simulate re-chlorination. After considering the nature of the reactions involved in chlorine decay, five simplified reaction schemes were evaluated for their suitability to describe chlorine concentration in bulk water. Each scheme was fitted to a sample of experimental data of chlorine decay in raw water obtained from Warragamba Dam (the major source of water supplied to Sydney, Australia). A scheme involving two parallel reactions of organic carbon compounds with chlorine is both necessary and sufficient to satisfy the requirements of modelling chlorine decay accurately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effective disinfection planning and management in large, complex water distribution systems requires an accurate network water quality model. This model should be based on reaction kinetics, which describes disinfectant loss from bulk water over time, within experimental error. Models in the literature were reviewed for their ability to meet this requirement in real networks. Essential features were identified as accuracy, simplicity, computational efficiency, and ability to describe consistently the effects of initial chlorine dose, temperature variation, and successive rechlorinations. A reaction scheme of two organic constituents reacting with free chlorine was found to be necessary and sufficient to provide the required features. Recent release of the multispecies extension (MSX) to EPANET and MWH Soft's H2OMap Water MSX network software enables users to implement this and other multiple-reactant bulk decay models in real system simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a methodology to achieve integrated planning and projects for secondary distribution circuits. The planning model is formulated as a mixed integer nonlinear programming problem (MINLP). In order to resolve this problem, a tabu search (TS) algorithm is used, with a neighborhood structure developed to explore the physical characteristics of specific geographies included in the planning and expansion of secondary networks, thus obtaining effective solutions as well as low operating costs and investments. The project stage of secondary circuits consists of calculating the mechanical efforts to determine the support structures of the primary and secondary distribution systems and determining the types of structures that should be used in the system according to topological and electrical parameters of the network and, therefore, accurately assessing the costs involved in the construction and/or reform of secondary systems. A constructive heuristic based on information of the electrical and topological conditions between the medium voltage and low voltage systems is used to connect the primary systems and secondary circuits. The results obtained from planning and design simulations of a real secondary system of electric energy distribution are presented.