995 resultados para FABRY-PEROT CAVITY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of multi-wavelength holography for surface shape measurement is presented. In our holographic setup a Bi12TiO 20 (BTO) photorefractive crystal was the holographic recording medium and a multimode diode laser emitting in the red region was the light source in a two-wave mixing scheme. The holographic imaging with multimode lasers results in multiple holograms in the BTO. By employing such lasers the resulting holographic image appears covered of interference fringes corresponding to the object relief and the interferogram spatial frequency is proportional to the diode laser free spectral range (FSR). We used a Fabry-Perot étalon at the laser output for laser mode selection. Thus, larger effective values of the laser FSR were achieved, leading to higher-spatial frequency interferograms and therefore to more sensitive and accurate measurements. The quantitative evaluation of the interferograms was performed through the phase stepping technique (PST) and the phase map unwrapping was carried out through the Cellular-Automata method. For a given surface, shape measurements with different interferogram spatial frequencies were performed and compared, concerning measurement noise and visual inspection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Advanced LIGO gravitational wave detectors are second-generation instruments designed and built for the two LIGO observatories in Hanford, WA and Livingston, LA, USA. The two instruments are identical in design, and are specialized versions of a Michelson interferometer with 4 km long arms. As in Initial LIGO, Fabry-Perot cavities are used in the arms to increase the interaction time with a gravitational wave, and power recycling is used to increase the effective laser power. Signal recycling has been added in Advanced LIGO to improve the frequency response. In the most sensitive frequency region around 100 Hz, the design strain sensitivity is a factor of 10 better than Initial LIGO. In addition, the low frequency end of the sensitivity band is moved from 40 Hz down to 10 Hz. All interferometer components have been replaced with improved technologies to achieve this sensitivity gain. Much better seismic isolation and test mass suspensions are responsible for the gains at lower frequencies. Higher laser power, larger test masses and improved mirror coatings lead to the improved sensitivity at mid and high frequencies. Data collecting runs with these new instruments are planned to begin in mid-2015.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report the frequency measurements of 18 optically pumped far-infrared (FIR) laser lines generated from CD3OH and (CH3OH)-C-13. We use the heterodyne technique of mixing FIR laser radiations and microwave radiation on a metal-insulator-metal point-contact tunnel diode to determine the FIR laser frequencies. Two FIR laser systems, consisting of CO2 waveguide pump lasers and Fabry-Perot FIR laser cavities, were used as optical sources. (C) 1997 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This doctoral dissertation aims to establish fiber-optic technologies overcoming the limiting issues of data communications in indoor environments. Specific applications are broadband mobile distribution in different in-building scenarios and high-speed digital transmission over short-range wired optical systems. Two key enabling technologies are considered: Radio over Fiber (RoF) techniques over standard silica fibers for distributed antenna systems (DAS) and plastic optical fibers (POFs) for short-range communications. Hence, the objectives and achievements of this thesis are related to the application of RoF and POF technologies in different in-building scenarios. On one hand, a theoretical and experimental analysis combined with demonstration activities has been performed on cost-effective RoF systems. An extensive modeling on modal noise impact both on linear and non-linear characteristics of RoF link over silica multimode fiber has been performed to achieve link design rules for an optimum choice of the transmitter, receiver and launching technique. A successful transmission of Long Term Evolution (LTE) mobile signals on the resulting optimized RoF system over silica multimode fiber employing a Fabry-Perot LD, central launch technique and a photodiode with a built-in ball lens was demonstrated up to 525m with performances well compliant with standard requirements. On the other hand, digital signal processing techniques to overcome the bandwidth limitation of POF have been investigated. An uncoded net bit-rate of 5.15Gbit/s was obtained on a 50m long POF link employing an eye-safe transmitter, a silicon photodiode, and DMT modulation with bit and power loading algorithm. With the insertion of 3x2N quadrature amplitude modulation constellation formats, an uncoded net-bit-rate of 5.4Gbit/s was obtained on a 50 m long POF link employing an eye-safe transmitter and a silicon avalanche photodiode. Moreover, simultaneous transmission of baseband 2Gbit/s with DMT and 200Mbit/s with an ultra-wideband radio signal has been validated over a 50m long POF link.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Silicon-on-insulator (SOI) is rapidly emerging as a very promising material platform for integrated photonics. As it combines the potential for optoelectronic integration with the low-cost and large volume manufacturing capabilities and they are already accumulate a huge amount of applications in areas like sensing, quantum optics, optical telecommunications and metrology. One of the main limitations of current technology is that waveguide propagation losses are still much higher than in standard glass-based platform because of many reasons such as bends, surface roughness and the very strong optical confinement provided by SOI. Such high loss prevents the fabrication of efficient optical resonators and complex devices severely limiting the current potential of the SOI platform. The project in the first part deals with the simple waveguides loss problem and trying to link that with the polarization problem and the loss based on Fabry-Perot Technique. The second part of the thesis deals with the Bragg Grating characterization from again the point of view of the polarization effect which leads to a better stop-band use filters. To a better comprehension a brief review on the basics of the SOI and the integrated Bragg grating ends up with the fabrication techniques and some of its applications will be presented in both parts, until the end of both the third and the fourth chapters to some results which hopefully make its precedent explanations easier to deal with.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In questo lavoro di tesi si studia un processo sperimentale necessario alla realizza- zione di un esperimento di Fisica Atomica. L’attivit`a svolta consiste nell’ottimizzazione dei paramentri di un algoritmo di con- trollo PI (proporzionale-integrale) atto a stabilizzare la temperatura di un Diodo Laser entro 1mK. Nella branca dell’Ottica Non Lineare (dove la polarizzazione del mezzo ha una rispo- sta non lineare al campo elettrico) si possono presentare casi in cui la birifrangenza del mezzo ha una forte dipendenza dalla temperatura. Questa pu o ` essere control- lata per il raggiungimento delle condizioni di phase matching. Le fluttuazioni di temperatura possono minare tramite la dilatazione termica la precisione di una ca- vit`a Fabry-Perot, utilizzata per controllare e misurare la lunghezza d’onda della luce, dato che nominalmente ∆ν/ν = − ∆L/L. Negli esperimenti di Laser Cooling infi- ne si lavora spesso con transizioni la cui larghezza naturale Γ ∼ 1MHz , mentre la frequenza di un laser pu o ́ dipendere dalla temperatura con coefficienti tipicamente dell’ordine del GHz/K. Questa stabilizzazione risulta dunque fondamentale per una vasta classe di esperi- menti nei quali le derive termiche possono influenzare drammaticamente il processo di misura. La tesi, in particolare, si apre con un capitolo nel quale si tratta brevemente il con- testo matematico di riferimento per i sistemi di controllo a retroazione. Tra questi e ` di particolare interesse la regolazione proporzionale-integrale. Il secondo capitolo si concentra sulla caratterizzazione del sistema in oggetto al fine di trovare la sua funzione di trasferimento ad anello aperto. Nel terzo capitolo infine, si utilizzano gli strumenti matematici descritti precedente- mente per ottimizzare i parametri del regolatore e si discutono i risultati ottenuti e le misure finali.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Output bits from an optical logic cell present noise due to the type of technique used to obtain the Boolean functions of two input data bits. We have simulated the behavior of an optically programmable logic cell working with Fabry Perot-laser diodes of the same type employed in optical communications (1550nm) but working here as amplifiers. We will report in this paper a study of the bit noise generated from the optical non-linearity process allowing the Boolean function operation of two optical input data signals. Two types of optical logic cells will be analyzed. Firstly, a classical "on-off" behavior, with transmission operation of LD amplifier and, secondly, a more complicated configuration with two LD amplifiers, one working on transmission and the other one in reflection mode. This last configuration has nonlinear behavior emulating SEED-like properties. In both cases, depending on the value of a "1" input data signals to be processed, a different logic function can be obtained. Also a CW signal, known as control signal, may be apply to fix the type of logic function. The signal to noise ratio will be analyzed for different parameters, as wavelength signals and the hysteresis cycles regions associated to the device, in relation with the signals power level applied. With this study we will try to obtain a better understanding of the possible effects present on an optical logic gate with Laser Diodes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Laser Diodes have been employed many times as light sources on different kinds of optical sensors. Their main function in these applications was the emission of an optical radiation impinging onto a certain object and, according to the characteristics of the reflected light, some information about this object was obtained. Laser diodes were acting, in a certain way, just as passive devices where their only function was to provide the adequate radiation to be later measured and analyzed. The objective of this paper is to report a new concept on the use of laser diodes taking into account their optical bistable properties. As it has been shown in several places, different laser diodes as, for example, DFB lasers and FP lasers, offer bistable characteristics being these characteristics a function of different parameters as wavelength, light polarization or temperature. Laser Bistability is strongly dependent on them and any small variation of above parameters gives rise to a strong change in the characteristics of its non-linear properties. These variations are analyzed and their application in sensing reported. The dependence on wavelength, spectral width, input power and phase variations, mainly for a Fabry-Perot Laser structure as basic configuration, is shown in this paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En este artículo se recogen diversas tecnologías que pueden facilitar la comunicación en un futuro, como son las fibras ópticas dopadas con tierras raras, los resonadores no lineales de Fabry-Perot o los dispositivos semiconductores basados en pozos cuánticos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Optical filters are crucial elements in optical communications. The influence of cascaded filters in the optical signal will affect the communications quality seriously. In this paper we will study and simulate the optical signal impairment caused by different kinds of filters which include Butterworth, Bessel, Fiber Bragg Grating (FBG) and Fabry-Perot (FP). Optical signal impairment is analyzed from an Eye Opening Penalty (EOP) and optical spectrum point of view. The simulation results show that when the center frequency of all filters aligns with the laser’s frequency, the Butterworth has the smallest influence to the signal while the F-P has the biggest. With a -1dB EOP, the amount of cascaded Butterworth optical filters with a bandwidth of 50 GHz is 18 in 40 Gbps NRZ-DQPSK systems and 12 in 100 Gbps PMNRZ- DQPSK systems. The value is reduced to 9 and 6 respectively for Febry-Perot optical filters. In the situation of frequency misalignment, the impairment caused by filters is more serious. Our research shows that with a frequency deviation of 5 GHz, only 12 and 9 Butterworth optical filters can be cascaded in 40 Gbps NRZ-DQPSK and 100 Gbps PM-NRZ-DQPSK systems respectively. We also study the signal impairment caused by different orders of the Butterworth filter model. Our study shows that although the higher-order has a smaller clipping effect in the transmission spectrum, it will introduce a more serious phase ripple which seriously affects the signal. Simulation result shows that the 2nd order Butterworth filter has the best performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Optical filters are crucial elements in optical communication networks. Their influence toward the optical signal will affect the communication quality seriously. In this paper we will study and simulate the optical signal impairment and crosstalk penalty caused by different kinds of filters, which include Butterworth, Bessel, Fiber Bragg Grating (FBG) and Fabry-Perot (F-P). Signal impairment from filter concatenation effect and crosstalk penalty from out-band and in-band are analyzed from Q-penalty, eye opening penalty (EOP) and optical spectrum. The simulation results show that signal impairment and crosstalk penalty induced by the Butterworth filter is the minimum among these four types of filters. Signal impairment caused by filter concatenation effect shows that when center frequency of all filters is aligned perfectly with the laser's frequency, 12 50-GHz Butterworth filters can be cascaded, with 1-dB EOP. This value is reduced to 9 when the center frequency is misaligned with 5 GHz. In the 50-GHz channel spacing DWDM networks, total Q-penalty induced by a pair of Butterworth filters based demultiplexer and multiplexer is lower than 0.5 dB when the filter bandwidth is in the range of 42-46 GHz.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo de esta tesis es el desarrollo y caracterización de biosensores ópticos sin marcado basados en celdas sensoras biofotónicas (BICELLs). Éstas son un nuevo concepto de biosensor desarrollado por el grupo de investigación y consiste en la combinación de técnicas de interrogación vertical, junto a estructuras fotónicas producidas usando métodos de micro- y nanofabricación. Varias conclusiones son extraídas de este trabajo. La primera, que se ha definido una BICELL estándar basada en interferómetros Fabry-Perot (FP). Se ha demostrado su capacidad para la comparación de rendimiento entre BICELLs estructuradas y para la realización de inmunoensayos de bajo coste. Se han estudiado diferentes técnicas de fabricación disponibles para la producción de BICELLs. Se determinó que la litografía de contacto a nivel de oblea produce estructuras de bajo coste, reproducibles y de alta calidad. La resolución alcanzada ha sido de 700 nm. El estudio de la respuesta a inmunoensayos de las BICELLs producidas se ha desarrollado en este trabajo. Se estudió la influencia de BICELLs basadas en diferentes geometrías y tamaños. De aquí resulta un nuevo enfoque para predecir el comportamiento de respuesta para la detección biológica de cualquier biosensor óptico estructurado, relacionando su superficie efectiva y su sensibilidad óptica. También se demostró una técnica novedosa y de bajo coste para la caracterización experimental de la sensibilidad óptica, basada en el depósito de películas ultradelgadas. Finalmente, se ha demostrado el uso de BICELLs desarrolladas en esta tesis, en la detección de aplicaciones reales, tales como hormonas, virus y proteínas. ABSTRACT The objective of this thesis is the development and characterization of optical label-free biosensors based on Bio-Photonic sensing Cells (BICELLs). BICELL is a novel biosensor concept developed by the research group, and it consists of a combination of vertical interrogation optical techniques and photonic structures produced by using micro- and nano-fabrication methods. Several main conclusions are extracted from this work. Firstly, a standard BICELL is defined based on FP interferometers, which demonstrated its capacity for accomplishing performance comparisons among different structured BICELLs, as well as to achieve low-cost immunoassays. Different available fabrication techniques were studied for BICELL manufacturing. It is found that contact lithography at wafer scale produce cost-effective, reproducible and high quality structures. The resolution achieved was 700 nm. Study on the response of developed BICELLs to immunoassays is performed within this work. It is therefore studied the influence of BICELLs based on different geometries and sizes in the immunoassay, which resulted in a new approach to predict the biosensing behaviour of any structured optical biosensor relating to its effective surface and optical sensitivity. Also, it is demonstrated a novel and low-cost characterization technique of the experimental optical sensitivity, based on ultrathin-film deposition. Finally, it is also demonstrated the capability of using the developed BICELLs in this thesis for real applications detection of hormones, virus and proteins.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present and analyze experimental results on the emission characteristics of a 1.5 ?m distributed feedback tapered master-oscillator power-amplifier in a wide range of steady-state injection conditions, showing different emission regimes under cw operation: stable single frequency emission, multi-frequency Fabry-Perot-like emission, and self-pulsation operation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho está fundamentado no desenvolvimento de uma metodologia e/ou uma tecnologia de obtenção e caracterização de filtros ópticos de interferência de banda passante variável [C.M. da Silva, 2010] e de banda de corte variáveis, constituídos por refletores dielétricos multicamadas de filmes finos intercalados por cavidades de Fabry-Perot não planares com espessuras linearmente variáveis, que apresentam a propriedade do deslocamento linear da transmitância máxima espectral em função da posição, isto é, um Filtro de Interferência Variável (FIV). Este método apresenta novas e abrangentes possibilidades de confecção de filtros ópticos de interferência variável: lineares ou em outras formas desejadas, de comprimento de onda de corte variável (passa baixa ou alta) e filtros de densidade neutra variável, através da deposição de metais, além de aplicações em uma promissora e nova área de pesquisa na deposição de filmes finos não uniformes. A etapa inicial deste desenvolvimento foi o estudo da teoria dos filtros ópticos dielétricos de interferência para projetar e construir um filtro óptico banda passante convencional de um comprimento de onda central com camadas homogêneas. A etapa seguinte, com base na teoria óptica dos filmes finos já estabelecida, foi desenvolver a extensão destes conhecimentos para determinar que a variação da espessura em um perfil inclinado e linear da cavidade entre os refletores de Bragg é o principal parâmetro para produzir o deslocamento espacial da transmitância espectral, possibilitando o uso de técnicas especiais para se obter uma variação em faixas de bandas de grande amplitude, em um único filtro. Um trabalho de modelagem analítica e análise de tolerância de espessuras dos filmes depositados foram necessários para a seleção da estratégia do \"mascaramento\" seletivo do material evaporado formado na câmara e-Beam (elétron-Beam) com o objetivo da obtenção do filtro espectral linear variável de características desejadas. Para tanto, de acordo com os requisitos de projeto, foram necessárias adaptações em uma evaporadora por e-Beam para receber um obliterador mecânico especialmente projetado para compatibilizar os parâmetros das técnicas convencionais de deposição com o objetivo de se obter um perfil inclinado, perfil este previsto em processos de simulação para ajustar e calibrar a geometria do obliterador e se obter um filme depositado na espessura, conformação e disposição pretendidos. Ao final destas etapas de modelagem analítica, simulação e refinamento recorrente, foram determinados os parâmetros de projeto para obtenção de um determinado FIV (Filtro de Interferência Variável) especificado. Baseadas nos FIVs muitas aplicações são emergentes: dispositivos multi, hiper e ultra espectral para sensoriamento remoto e análise ambiental, sistemas Lab-on-Chip, biossensores, detectores chip-sized, espectrofotometria de fluorescência on-chip, detectores de deslocamento de comprimento de onda, sistemas de interrogação, sistemas de imageamento espectral, microespectrofotômetros e etc. No escopo deste trabalho se pretende abranger um estudo de uma referência básica do emprego do (FIV) filtro de interferência variável como detector de varredura de comprimento de ondas em sensores biológicos e químicos compatível com pós processamento CMOS. Um sistema básico que é constituído por um FIV montado sobre uma matriz de sensores ópticos conectada a um módulo eletrônico dedicado a medir a intensidade da radiação incidente e as bandas de absorção das moléculas presentes em uma câmara de detecção de um sistema próprio de canais de microfluidos, configurando-se em um sistema de aquisição e armazenamento de dados (DAS), é proposto para demonstrar as possibilidades do FIV e para servir de base para estudos exploratórios das suas diversas potencialidades que, entre tantas, algumas são mencionadas ao longo deste trabalho. O protótipo obtido é capaz de analisar fluidos químicos ou biológicos e pode ser confrontado com os resultados obtidos por equipamentos homologados de uso corrente.