862 resultados para Eye Diseases.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Allergy is a common hypersensitivity disorder that affects 15% to 20% of the population and its prevalence is increasing worldwide. Its severity correlates with the degree of eosinophil infiltration into the conjunctiva, which is mediated by chemokines that stimulate the production of adhesion molecules like intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) on the endothelial cell surface. The α4β1 and α4β7 integrins are expressed in eosinophils and contribute to their activation and infiltration in AC through the binding to VCAM-1 or fibronectin, expressed on vascular endothelial cells. Blockade of α4 integrins might be a therapeutical achievement in allergic eye diseases. DS 70, that show an IC50 in the nanomolar range against α4β1 integrin in Jurkat cells and in the eosinophilic cell line EOL-1. This compound was able to prevent cell adhesion to VCAM-1 and FN in vitro. In a scintillation proximity assay DS70 displaced 125I-FN binding to human α4β1 integrin and, in flow cytometry analysis, it antagonized the binding of a primary antibody to α4β1 integrin expressed on the Jurkat cells surface as well. Furthermore, we analysed also its effects on integrin α4β1 signalling. In an vivo model of allergic conjunctivitis, topical DS70 reduced the clinical aspects of EPR (early phase reaction) and LPR (late phase reaction), by reducing clinical score, eosinophil accumulation, mRNA levels of cytochines and chemochines pro-inflammatory and the conjunctival expression of α4 integrin. In conclusion, DS70 seems a novel antiallergic ocular agent that has significant effects on both early and late phases of ocular allergy.
Resumo:
OBJECTIVE To determine the practicability and accuracy of central corneal thickness (CCT) measurements in living chicks utilizing a noncontact, high-speed optical low-coherence reflectometer (OLCR) mounted on a slit lamp. ANIMALS STUDIED Twelve male chicks (Gallus gallus domesticus). Procedures Measurements of CCT were obtained in triplicate in 24 eyes of twelve 1-day-old anaesthetized chicks using OLCR. Every single measurement taken by OLCR consisted of the average result of 20 scans obtained within seconds. Additionally, corneal thickness was determined histologically after immersion fixation in Karnovsky's solution alone (20 eyes) or with a previous injection of the fixative into the anterior chamber before enucleation (4 eyes). RESULTS Central corneal thickness measurements using OLCR in 1-day-old living chicks provide a rapid and feasible examination technique. Mean CCT measured with OLCR (189.7 ± 3.34 μm) was significantly lower than histological measurements (242.1 ± 47.27 μm) in eyes with fixation in Karnovsky's solution (P = 0.0005). In eyes with additional injection of Karnovsky's fixative into the anterior chamber, mean histologically determined CCT was 195.2 ± 8.25 μm vs. 191.9 ± 8.90 μm with OLCR. A trend for a lower variance was found compared to the eyes that had only been immersion fixed. CONCLUSION Optical low-coherence reflectometry is an accurate examination technique to measure in vivo CCT in the eye of newborn chicks. The knowledge of the thickness of the chick cornea and the ability to obtain noninvasive, noncontact measurements of CCT in the living animal may be of interest for research and development of eye diseases in chick models.
Resumo:
At the 111th German Medical Assembly in May 2008 in Ulm, Germany, a public debate on rationing of health care performances was started. Since the money in the German health care system is not enough to provide every diagnostic or therapy for every patient as a coverage of the compulsory medical insurances, a lot of specific health care performances have been rationed during the last years not to be covered by the regular medical insurance any more, such as, e. g., PSA measurements in urology or IOP measurements in ophthalmology. In contrast to the health care system in Scandinavia, where rationing of health care performances is publicly documented by the government, no similar public statements exist in Germany. Due to this, it is left to physicians to explain to their patients the "hidden" rationing of public health care performances, which also leads to an increase in individual health care performances (IGeL in Germany) to be paid for privately by the patient. It is undoubtedly true that not all medically possible performances need to be paid for by the health insurance; however, an official determination of these "out of pocket" health care performances is necessary. Therefore, it was the aim herein to work out possible "stop" criteria--according to the Scandinavian system--for common eye diseases and consecutive therapies, which need not be paid for or only be paid after a delay by the health insurances.
Resumo:
Objectives: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. Study Design and Setting: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Testeretest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen’s kappa (k). Results: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good testeretest repeatability both for the scores obtained [ICC 5 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (k 5 0.612; 95% CI: 0.384, 0.839). Conclusion: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.
Resumo:
Enquadramento: O acesso à saúde ocular em escolares dirige primariamente a prevenção de problemas visuais que dificultem o aprendizado, impossibilitando o desenvolvimento das atividades intelectuais e sociais. Os projetos de promoção da saúde oftalmológica são, para a grande maioria dos alunos, a primeira e rara oportunidade de avaliar a visão. Objetivos: Identificar os tipos de déficit visuais mais comuns nas crianças da região metropolitana do Recife; Identificar as queixas mais frequentes relacionadas a baixa de visão; Realizar campanha preventiva para identificação dos déficits, tendo como referência a Guarnição de Aeronáutica de Recife (GAR). Métodos: Estudo descritivo, transversal, intervencionista e quantitativo. A pesquisa ocorreu nos anos de 2013 e 2014, em uma população de 1500 crianças residentes na cidade de Recife, estado de Pernambuco, Brasil, com idades variando entre 7 e 9 anos, onde obtivemos uma amostra de 490 inscrições para participação no programa. Resultados: No primeiro período, atingimos 98,5% de objetividade, aumentando para 99,3% no segundo período. Os estudantes realizaram as consultas maioritariamente pela manhã (58,7%), em escola particular (81,6%) e na sua maioria (57,1%), eram do sexo feminino. A presença de queixas atingiu 78,6% e os sinais e sintomas mais referidos foram: cefaleia (20,8%), prurido ocular (17,6%) e dificuldade de enxergar o quadro (16,8%). Foram identificados e corrigidos 53 casos de erros de refração sendo o astigmatismo (4,74%), o mais diagnosticado, 7 casos de estrabismo e tratados 12 de conjuntivite. Conclusões: Em 2013, 15,1% e em 2014, 14,2% das crianças apresentaram baixa acuidade visual. Astigmatismo e miopia representam 10% dos problemas mais comuns seguidos de hipermetropia e conjuntivite. 84% do total de nossa amostra refere dificuldade de visualização no quadro negro, 68% manifestam cefaleias, 85% dor ocular, 75,5% vermelhidão ocular e 80,3% prurido ocular. Resumindo, os distúrbios visuais são comuns nas crianças, justificando programas de saúde preventiva nas unidades de saúde da FAB. Palavras-chave: Acuidade visual; Criança; Preventiva.
Resumo:
Bd. 44 (1906)-Bd. 51 (1913) also called n.F., Bd. 1-16.
Resumo:
"Register": 5. Bd, p. [277]-287.
Resumo:
Imprint and other data taken from v. 3. t.p., edition confirmed in N.Y. Academy of Medicine Author Catalog.
Resumo:
Translation of Die Krankheiten des menschlichen Auges.
Resumo:
Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.