340 resultados para Extracorporeal shockwave lithotripsy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary artery bypass grafting (CABG) by electroencephalogram P300 wave event-related potentials and number connection test (NCT) as metrics of cognitive function. METHODS Cognitive brain function was assessed in 31 patients in 2013 with a mean age of 65 years [standard deviation (SD) 10] undergoing CABG by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds) directly prior to intervention, 7 days after and 3 months later. Number connection test, serving as method of control, was performed simultaneously in all patients. RESULTS Seven days following CABG, cognitive P300 evoked potentials were comparable with preoperative baseline values [vertex (Cz) 376 (SD 11) ms vs 378 (18) ms, P = 0.39; frontal (Fz) 377 (11) vs 379 (21) ms, P = 0.53]. Cognitive brain function at 3 months was compared with baseline values [(Cz) 376 (11) ms vs 371 (14 ms) P = 0.09; (Fz) 377 (11) ms vs 371 (15) ms, P = 0.04]. Between the first postoperative measurement and 3 months later, significant improvement was observed [(Cz) 378 (18) ms vs 371 (14) ms, P = 0.03; (Fz) 379 (21) vs 371 (15) ms, P = 0.02]. Similar clearly corresponding patterns could be obtained via the number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (P = 0.05) and (Fz) results (P = 0.04). CONCLUSIONS MECC does not adversely affect cognitive brain function after CABG. Additionally, these patients experience a substantial significant cognitive improvement after 3 months, evidentiary proving that the concept of MECC ensures safety and outcome in terms of brain function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. METHODS In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. RESULTS Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. CONCLUSIONS Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Painful cutaneous injection site reactions may hamper treatment with interferon β (IFN-β) and glatiramer acetate (GA) in multiple sclerosis (MS) patients. OBJECTIVE To maintain therapy adherence, efficient therapeutic modalities for these subcutaneous inflammatory lesions are urgently needed. We tested the application of local extracorporeal shock wave therapy (ESWT). METHODS We applied 5 sessions of ESWT to 8 patients suffering from MS who had developed painful panniculitis at the injection sites of either IFN-β or GA. Clinical outcomes, i.e. pain reduction and regression of induration, were assessed 3 and 6 months after completion of the ESWT using a visual analogue score. RESULTS All patients showed both significant pain reduction and reduction of the skin induration in the treated lesions, while in untreated control lesions there was no improvement. CONCLUSION ESWT proved to be a non-invasive, safe and efficient physical treatment modality for injection-induced painful cutaneous side effects of disease-modifying drugs in MS. © 2014 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Minimized Extracorporeal Circulation does not impair cognitive brain function after coronary artery bypass grafting – – Objectives – Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary bypass grafting (CABG) by Electroencephalogram (EEG) P 300 wave event related potentials (ERP) and number connection test ( NCT) as metrics of cognitive function. – – Methods – Cognitive brain function was assessed in 31 patients with a mean age of 65y (Standard Deviation/SD 10) undergoing coronary artery bypass grafting (CABG) by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds [ms]) directly prior to intervention, 7 days after and 3 month later. Number connection test (NCT), serving as method of control, was performed simultaneously in all patients. – – Results – Seven days following CABG, cognitive P300 evoked potentials were comparable to preoperative baseline values (vertex [Cz] 376 (SD 11) ms vs. 378 (18) ms, p=0.39, frontal [Fz] 377 (11) vs. 379 (21) ms, p=0.53). Cognitive brain function showed at 3 months compared to baseline values ([Cz] 376 (11) ms vs. 371 (14 ms) p=0.09, [Fz] 377 (11) ms vs. 371 (15) ms, p=0.04. Between the first postoperative measurement and 3 months later, significant improvement was observed ([Cz] 378 (18) ms vs. 371 (14) ms, p=0.03, [Fz] 379 (21) vs. 371 (15) ms, p=0.02). Similar clearly corresponding patterns could be obtained via number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (p = 0.05) and (Fz) results (p = 0.04). – – Conclusions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimal invasive extracorporeal circulation (MiECC) systems have initiated important efforts within science and technology to further improve the biocompatibility of cardiopulmonary bypass components to minimize the adverse effects and improve end-organ protection. The Minimal invasive Extra-Corporeal Technologies international Society was founded to create an international forum for the exchange of ideas on clinical application and research of minimal invasive extracorporeal circulation technology. The present work is a consensus document developed to standardize the terminology and the definition of minimal invasive extracorporeal circulation technology as well as to provide recommendations for the clinical practice. The goal of this manuscript is to promote the use of MiECC systems into clinical practice as a multidisciplinary strategy involving cardiac surgeons, anaesthesiologists and perfusionists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We read with great interest the large-scale network meta-analysis by Kowalewski et al. comparing clinical outcomes of patients undergoing coronary artery bypass grafting (CABG) operated on using minimal invasive extracorporeal circulation (MiECC) or off-pump (OPCAB) with those undergoing surgery on conventional cardiopulmonary bypass (CPB) [1]. The authors actually integrated into single study two recently published meta-analysis comparing MiECC and OPCAB with conventional CPB, respectively [2, 3] into a single study. According to the results of this study, MiECC and OPCAB are both strongly associated with improved perioperative outcomes following CABG when compared with CABG performed on conventional CPB. The authors conclude that MiECC may represent an attractive compromise between OPCAB and conventional CPB. After carefully reading the whole manuscript, it becomes evident that the role of MiECC is clearly undervalued. Detailed statistical analysis using the surface under the cumulative ranking probabilities indicated that MiECC represented the safer and more effective intervention regarding all-cause mortality and protection from myocardial infarction, cerebral stroke, postoperative atrial fibrillation and renal dysfunction when compared with OPCAB. Even though no significant statistical differences were demonstrated between MiECC and OPCAB, the superiority of MiECC is obvious by the hierarchy of treatments in the probability analysis, which ranked MiECC as the first treatment followed by OPCAB and conventional CPB. Thus, MiECC does not represent a compromise between OPCAB and conventional CPB, but an attractive dominant technique in CABG surgery. These results are consistent with the largest published meta-analysis by Anastasiadis et al. comparing MiECC versus conventional CPB including a total of 2770 patients. A significant decrease in mortality was observed when MiECC was used, which was also associated with reduced risk of postoperative myocardial infarction and neurological events [4]. Similarly, another recent meta-analysis by Benedetto et al. compared MiECC versus OPCAB and resulted in comparable outcomes between these two surgical techniques [5]. As stated in the text, superiority of MiECC observed in the current network meta-analysis, when compared with OPCAB, could be attributed to the fact that MiECC offers the potential for complete revascularization, whereas OPCAB poses a challenge for unexperienced surgeons; especially when distal marginal branches on the lateral and/or posterior wall of the heart need revascularization. This is reflected by a significantly lower number of distal anastomoses performed in OPCAB when compared with conventional CPB. Therefore, taking into consideration the literature published up to date, including the results of the current article, we advocate that MiECC should be integrated in the clinical practice guidelines as a state-of-the-art technique and become a standard practice for perfusion in coronary revascularization surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current guidelines for the treatment of hypothermic cardiocirculatory arrest recommend extracorporeal life support and rewarming, using cardiopulmonary bypass or extracorporeal membrane oxygenation circuits. Both have design-related shortcomings which may result in prolonged reperfusion time or insufficient oxygen delivery to vital organs. This article describes clear advantages of minimally invasive extracorporeal circulation systems during emergency extracorporeal life support in hypothermic arrest. The technique of minimally invasive extracorporeal circulation for reperfusion and rewarming is represented by the case of a 59-year-old patient in hypothermic cardiocirculatory arrest at 25.3°C core temperature, with multiple trauma. With femoro-femoral cannulation performed under sonographic and echocardiographic guidance, extracorporeal life support was initiated using a minimally invasive extracorporeal circulation system. Perfusing rhythm was restored at 28°C. During rewarming on the mobile circuit, trauma surveys were completed and the treatment initiated. Normothermic weaning was successful on the first attempt, trauma surgery was completed and the patient survived neurologically intact. For extracorporeal resuscitation from hypothermic arrest, minimally invasive extracorporeal circulation offers all the advantages of conventional cardiopulmonary bypass and extracorporeal membrane oxygenation systems without their shortcomings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMMUNOLOGICAL MECHANISMS OF EXTRACORPOREAL PHOTOPHERESIS IN CUTANEOUS T CELL LYMPHOMA AND GRAFT VERSUS HOST DISEASE Publication No.___________ Lisa Harn-Ging Shiue, B.S. Supervisory Professor: Madeleine Duvic, M.D. Extracorporeal photopheresis (ECP) is an effective, low-risk immunomodulating therapy for leukemic cutaneous T cell lymphoma (L-CTCL) and graft versus host disease (GVHD), but whether the mechanism(s) of action in these two diseases is (are) identical or different is unclear. To determine the effects of ECP in vivo, we studied regulatory T cells (T-regs), cytotoxic T lymphocytes (CTLs), and dendritic cells (DCs) by immunofluorescence flow cytometry in 18 L-CTCL and 11 GVHD patients before and after ECP at Day 2, 1 month, 3 months, and 6 months. In this study, ECP was effective in 12/18 L-CTCL patients with a 66.7% overall response rate (ORR) and 6/11 GVHD patients with a 54.5% ORR. Prior to ECP, the percentages of CD4+Foxp3+ T cells in 9 L-CTCL patients were either lower (L-CTCL-Low, n=2) or higher (L-CTCL-High, n=7) than normal. Five of the 7 GVHD patients had high percentages of CD4+Foxp3+ T cells (GVHD-High). Six of 7 L-CTCL-High patients had >80% CD4+Foxp3+ T cells which were correlated with tumor cells, and were responders. Both L-CTCL-High and GVHD-High patients had decreased percentages of CD4+Foxp3+ and CD4+Foxp3+CD25- T cells after 3 months of treatment. CD4+Foxp3+CD25+ T cells increased in GVHD-High patients but decreased in L-CTCL-High patients after 3 months of ECP. In addition, numbers of CTLs were abnormal. We confirmed that numbers of CTLs were low in L-CTCL patients, but high in GVHD patients prior to ECP. After ECP, CTLs increased after 1 month in 4/6 L-CTCL patients whereas CTLs decreased after 6 months in 3/3 GVHD patients. Myeloid (mDCs) and plasmacytoid DCs (pDCs) were also low at baseline in L-CTCL and GVHD patients confirming the DC defect. After 6 months of ECP, numbers and percentages of mDCs and pDCs increased in L-CTCL and GVHD. MDCs were favorably increased in 8/12 L-CTCL responders whereas pDCs were favorably increased in GVHD patients. These data suggest that ECP is favorably modulating the DC subsets. In L-CTCL patients, the mDCs may orchestrate Th1 cell responses to overcome immune suppression and facilitate disease regression. However, in GVHD patients, ECP is favorably down-regulating the immune system and may be facilitating immune tolerance to auto-or allo-antigens. In both L-CTCL and GVHD patients, DCs are modulated, but the T cell responses orchestrated by the DCs are different, suggesting that ECP modulates depending on the immune milieu. _______________

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the resource implications and short term outcomes of extracorporeal membrane oxygenation and conventional management for term babies with severe respiratory failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischaemic cerebral accidents are frequent following extracorporeal membrane oxygenation (ECMO), especially after fixing the reinjection cannula in the right primitive carotid artery, which leads to an interruption in downstream flow. We describe a rare and unusual symptom of cerebral ischaemic accident that is known as Capgras syndrome. This feature is interesting because it may be documented by computed tomography (CT) scan and particular electroencephalography signals. It appears that our observation represents the first documented case of Capgras syndrome complicating ECMO. This incident emphasizes the potential hazards associated with right common artery ligature for venoarterial extracorporeal membrane oxygenation (VAECMO). In addition, it shows that this psychiatric symptom (that has been interpreted psychodynamically for many years) can have an organic basis, which should be studied.