984 resultados para Experimental apparatus
Resumo:
The work of this thesis has been focused on the characterisation of inorganic membranes for the hydrogen purification from steam reforming gas. Composite membranes based on porous inorganic supports coated with palladium silver alloys and ceramic membranes have been analysed. A brief resume of theoretical laws governing transport of gases through dense and porous inorganic membranes and an overview on different methods to prepare inorganic membranes has been also reported. A description of the experimental apparatus used for the characterisation of gas permeability properties has been reported. The device used permits to evaluate transport properties in a wide range of temperatures (till 500°C) and pressures (till 15 bar). Data obtained from experimental campaigns reveal a good agreement with Sievert law for hydrogen transport through dense palladium based membranes while different transport mechanisms, such as Knudsen diffusion and Hagen-Poiseuille flow, have been observed for porous membranes and for palladium silver alloy ones with pinholes in the metal layer. Mixtures permeation experiments reveal also concentration polarisation phenomena and hydrogen permeability reduction due to carbon monoxide adsorption on metal surface.
Resumo:
Diese Arbeit befasst sich mit der photoinduzierten Erzeugung neutraler Pionen, sehr nahe an der Schwellenenergie. Dabei werden zwei Ziele verfolgt: Zum einen die Überprüfung von Vorhersagen dieser effektiven Theorien und Modelle, zum anderen werden hier erstmals alle relevanten Partialwellenamplituden modellunabhängig aus gemessenen Observablen bestimmt. Diese Methode soll in Zukunft auch bei höheren Energien im Bereich der Nukleonresonanzen Anwendung finden. rnrnKonkret wird die Durchführung und Analyse eines Experiments vorgestellt, welches am Mainzer Mikrotron (MAMI) in den Jahren 2010 bis 2013 mit zirkular polarisiertem Photonenstrahl stattfand. Der Photonenstrahl wurde an einer Anlage zur Erzeugung energiemarkierter Bremsstrahlung aus dem Elektronenstrahl von MAMI gewonnen. Zum Nachweis der Reaktionsprodukte diente das hermetische 4pi CB/TAPS-Detektorsystem. Erstmalig standen bei derartigen Messungen auch transversal polarisierte Protonen zur Verfügung. Dazu wird Butanol in einer speziellen Apparatur dynamisch polarisiert. Molekularer Wasserstoff lässt sich aufgrund der para-Konfiguration nicht polarisieren. Wegen der Verwendung von Butanol als Targetmaterial, bei dem weniger als 5% aller erzeugten Pionen an polarisierten Protonen produziert wurden, ist die Behandlung des Untergrunds eine zentrale Aufgabe. rnrnEs werden zwei Methoden der Untergrundseparation vorgestellt, wovon die bessere in der Analyse angewendet wurde. Abschließend findet eine ausführliche Bewertung systematischer Fehler statt.rnrnDie erstmalige Verwendung transversal polarisierter Protonen ermöglicht den Zugang zu bisher nicht gemessenen Spin"=Freiheitsgraden. In Kombination mit einem komplementären Vorläufer-Experiment aus dem Jahr 2008 mit linear polarisiertem Photonenstrahl konnten aus den gewonnenen Daten erstmals alle komplexen s- und p-Partialwellenamplituden modellunabhängig bestimmt werden. rnrnDarüber hinaus wurden im Rahmen dieser Arbeit wesentliche Verbesserungen am apparativen Aufbau erzielt. Beispiele sind ein Elektronenstrahl-Polarimeter, ein zellularer CB-Multiplizitätstrigger, sowie signifikante Verbesserungen der Datennahmeelektronik und des Triggersystems, die teilweise in dieser Arbeit vorgestellt werden.
Resumo:
Fuel Cells are a promising alternative energy technology. One of the biggest problems that exists in fuel cell is that of water management. A better understanding of wettability characteristics in the fuel cells is needed to alleviate the problem of water management. Contact angle data on gas diffusion layers (GDL) of the fuel cells can be used to characterize the wettability of GDL in fuel cells. A contact angle measurement program has been developed to measure the contact angle of sessile drops from drop images. Digitization of drop images induces pixel errors in the contact angle measurement process. The resulting uncertainty in contact angle measurement has been analyzed. An experimental apparatus has been developed for contact angle measurements at different temperature, with the feature to measure advancing and receding contact angles on gas diffusion layers of fuel cells.
Resumo:
AEgIS experiment’s main goal is to measure the local gravitational acceleration of antihydrogen¯g and thus perform a direct test of the weak equivalence principle with antimatter. In the first phase of the experiment the aim is to measure ¯g with 1% relative precision. This paper presents the antihydrogen production method and a description of some components of the experiment, which are necessary for the gravity measurement. Current status of the AE¯gIS experimental apparatus is presented and recent commissioning results with antiprotons are outlined. In conclusion we discuss the short-term goals of the AE¯gIS collaboration that will pave the way for the first gravity measurement in the near future.
Resumo:
The deformation behavior of atomically clean, nanometer sized tungsten / gold contacts was studied at room temperature in ultra-high vacuum. An instrument that combines atomic force microscopy (AFM), scanning tunneling microscopy (STM), and field ion microscopy (FIM) into a single experimental apparatus was designed, constructed, and calibrated. A cross-hair force sensor having a spring constant of - 442 N/m was developed and its motion was monitored during indentation experiments with a differential interferometer. Tungsten tips of controlled size (12.8 nm < tip radius < 2 1.6 nm) were first shaped and characterized using FIM and then indented into a Au (1 10) single crystal to depths ranging from 1.5 nrn to 18 nm using the force sensor. Continuum mechanics models were found to be valid in predicting elastic deformation during initial contact and plastic zone depths despite our small size regime. Multiple discrete yielding events lasting < 1.5 ms were observed during the plastic deformation regime; at the yield points a maximum value for the principal shear stress was measured to be 5 + 1 GPa. During tip withdrawal, "pop-out" events relating to material relaxation within the contact were observed. Adhesion between the tip and sample led to experimental signatures that suggest neck formation prior to the break of contact. STM images of indentation holes revealed various shapes that can be attributed to the (1 1 1 ) (1 10) crystallographic slip system in gold. FIM images of the tip after indentation showed no evidence of tip damage
Resumo:
A cold atomic cloud is a versatile object, because it offers many handles to control and tune its properties. This facilitates studies of its behavior in various circumstances, such as sample temperature, size and density, composition, dimensionality and coherence time. The range of possible experiments is constrained by the specifications of the atomic species used. In this thesis presents the work done in the experiment for laser cooling of strontium atoms, focusing on its stability, which should provide cold and ultracold samples for the study of collective effects in light scattering. From the initial apparatus, innumerous changes were performed. The vacuum system got improved and now reached lower ultra high vacuum due to the pre-baking done to its parts and adding a titanium-sublimation stage. The quadrupole trap were improved by the design and construction of a new pair of coils. The stability of the blue, green and red laser systems and the loss prevention of laser light were improved, giving rise to a robust apparatus. Another important point is the development of homemade devices to reduce the costs and to be used as a monitor of different parts of an cold atoms experiment. From this homemade devices, we could demonstrate a dramatic linewidth narrowing by injection lock of an low cost 461 nm diode laser and its application to our strontium experiment. In the end, this improved experimental apparatus made possible the study of a new scattering effect, the mirror assisted coherent back-scattering (mCBS).
Resumo:
Several fermentation methods for the production of the enzyme dextransucrase have been employed. The theoretical aspects of these fermentation techniques have been given in the early chapters of this thesis together with a brief overview of enzyme biotechnology. A literature survey on cell recycle fermentation has been carried out followed by a survey report on dextransucrase production, purification and the reaction mechanism of dextran biosynthesis. The various experimental apparatus as employed in this research are described in detail. In particular, emphasis has been given to the development of continuous cell recycle fermenters. On the laboratory scale, fed-batch fermentations under anaerobic low agitation conditions resulted in dextransucrase activities of about 450 DSU/cm3 which are much higher than the yields reported in the literature and obtained under aerobic conditions. In conventional continuous culture the dilution rate was varied in the range between 0.375 h-1 to 0.55 h-1. The general pattern observed from the data obtained was that the enzyme activity decreased with increase in dilution rate. In these experiments the maximum value of enzyme activity was ∼74 DSU/cm3. Sparging the fermentation broth with CO2 in continuous culture appears to result in a decrease in enzyme activity. In continuous total cell recycle fermentations high steady state biomass levels were achieved but the enzyme activity was low, in the range 4 - 27 DSU/cm3. This fermentation environment affected the physiology of the microorganism. The behaviour of the cell recycle system employed in this work together with its performance and the factors that affected it are discussed in the relevant chapters. By retaining the whole broth leaving a continuous fermenter for between 1.5 - 4 h under controlled conditions, the enzyme activity was enhanced with a certain treatment from 86 DSU/cm3 to 180 DSU/cm3 which represents a 106% increase over the enzyme activity achieved by a steady-state conventional chemostat. A novel process for dextran production has been proposed based on the findings of this latter part of the experimental work.
Resumo:
The possible evaporation of lubricant in fluid film bearings has been investigated theoretically and by experiment using a radial flow hydrostatic bearing supplied with liquid refrigerant R114. Good correlation between measured and theoretical values was obtained using a bespoke computational fluid dynamic model in which the flow was assumed to be laminar and adiabatic. The effects of viscous dissipation and vapour generation within the fluid film are fully accounted for by applying a fourth order Runge-Kutta routine to satisfy the radial and filmwise transverse constraints of momentum, energy and mass conservation. The results indicate that the radial velocity profile remains parabolic while the flow remains in the liquid phase and that the radial rate of enthalpy generation is then constant across the film at a given radius. The results also show that evaporation will commence at a radial location determined by geometry and flow conditions and in fluid layers adjacent to the solid boundaries. Evaporation is shown to progress in the radial direction and the load carrying capacity of such a bearing is reduced significantly. Expressions for the viscosity of the liquid/vapour mixture found in the literature survey have not been tested against experimental data. A new formulation is proposed in which the suitable choice of a characteristic constant yields close representation to any of these expressions. Operating constraints imposed by the design of the experimental apparatus limited the extent of the surface over which evaporation could be obtained, and prevented clear identification of the most suitable relationship for the viscosity of the liquid/vapour mixture. The theoretical model was extended to examine the development of two phase flow in a rotating shaft face seal of uniform thickness. Previous theoretical analyses have been based on the assumption that the radial velocity profile of the flow is always parabolic, and that the tangential component of velocity varies linearly from the value at the rotating surface, to zero at the stationary surface. The computational fluid dynamic analysis shows that viscous shear and dissipation in the fluid adjacent to the rotating surface leads to developing evaporation with a consequent reduction in tangential shear forces. The tangential velocity profile is predicted to decay rapidly through the film, exhibiting a profile entirely different to that assumed by previous investigators. Progressive evaporation takes place close to the moving wall and does not occur completely at a single radial location, as has been claimed in earlier work.
Resumo:
The Ultrasound Laboratory of the Nuclear Engineering Institute (LABUS / IEN) has developed an ultrasonic technique to measure porosity in nuclear fuel pellets (UO2). By difficulties related to the handling of UO2 pellets, Alumina (Al2O3) pellets have been used in preliminary tests, until a methodology for tests with pellets of UO2 could be defined. In a previous work, in which a contact ultrasonic technique was used, good results were obtained to measure the porosity of Alumina pellets. In the current studies, it was found that the frequency spectrum of an ultrasonic pulse is very sensitive to the porosity of the medium in which it propagates. In order to define the most appropriate experimental apparatus for using immersion technique in future tests, two ultrasonic systems, available in LABUS, which permit to work with the ultrasonic pulse in the frequency domain were evaluated . One system was the Explorer II (Matec INSTRUMENTS) and the other the ultrasonic pulse generator Epoch 4 Plus (Panametrics) coupled with an oscilloscope TDS 3032B (Tektronix). For this evaluation, several frequency spectra were obtained with the two equipment, by the passage of the ultrasonic wave in the same pellet of Alumina. This procedure was performed on four different days, on each day 12 ultrasonic signals were acquired, one signal every 10 minutes, with each apparatus. The results were compared and analyzed as regard the repeatability of the frequency spectra obtained.
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
Practical application of flow boiling to ground- and space-based thermal management systems hinges on the ability to predict the system’s heat removal capabilities under expected operating conditions. Research in this field has shown that the heat transfer coefficient within two-phase heat exchangers can be largely dependent on the experienced flow regime. This finding has inspired an effort to develop mechanistic heat transfer models for each flow pattern which are likely to outperform traditional empirical correlations. As a contribution to the effort, this work aimed to identify the heat transfer mechanisms for the slug flow regime through analysis of individual Taylor bubbles. An experimental apparatus was developed to inject single vapor Taylor bubbles into co-currently flowing liquid HFE 7100. The heat transfer was measured as the bubble rose through a 6 mm inner diameter heated tube using an infrared thermography technique. High-speed flow visualization was obtained and the bubble film thickness measured in an adiabatic section. Experiments were conducted at various liquid mass fluxes (43-200 kg/m2s) and gravity levels (0.01g-1.8g) to characterize the effect of bubble drift velocity on the heat transfer mechanisms. Variable gravity testing was conducted during a NASA parabolic flight campaign. Results from the experiments showed that the drift velocity strongly affects the hydrodynamics and heat transfer of single elongated bubbles. At low gravity levels, bubbles exhibited shapes characteristic of capillary flows and the heat transfer enhancement due to the bubble was dominated by conduction through the thin film. At moderate to high gravity, traditional Taylor bubbles provided small values of enhancement within the film, but large peaks in the wake heat transfer occurred due to turbulent vortices induced by the film plunging into the trailing liquid slug. Characteristics of the wake heat transfer profiles were analyzed and related to the predicted velocity field. Results were compared and shown to agree with numerical simulations of colleagues from EPFL, Switzerland. In addition, a preliminary study was completed on the effect of a Taylor bubble passing through nucleate flow boiling, showing that the thinning thermal boundary layer within the film suppressed nucleation, thereby decreasing the heat transfer coefficient.
Resumo:
In refrigeration systems a small amount of compressor lubricant is entrained in the refrigerant and circulated through the system, where some is retained in each component. The suction line to the compressor has the largest potential for oil retention. This paper presents results from an experimental apparatus that has been constructed to circulate POE (polyolester) oil and R410A at a controlled mass flux, OCR (oil in circulation ratio), and apparent superheat, and to directly measure the pressure drop and mass of oil retained in horizontal and vertical suction lines. The bulk vapor velocity and overall void fraction are determined from direct mass and temperature measurements. The oil retention, pressure drop, and flow regimes near the minimum ASHRAE recommended mass flux condition are explored. It was found that oil retention begins to increase sharply even above the minimum recommended flux, so conditions near the minimum should be avoided. Two relationships were developed to predict the oil retention in the vertical and horizontal suction lines. The average error from the predictions method was 10.9% for the vertical tube, and 7.9% for the horizontal tube.
Resumo:
O presente trabalho tem como principal objectivo a avaliação do sujamento da superfície de transferência de calor do evaporador de uma bomba de calor, quando se utiliza o efluente da fábrica de pasta e papel da Portucel Soporcel em Cacia como fluido de aquecimento. Para a realização deste estudo montou-se uma instalação, composta por uma bomba de calor, um circuito de água de arrefecimento do condensador da bomba de calor e um circuito de água residual quente para o aquecimento do evaporador da bomba de calor. O ensaio decorreu durante um período de 84 dias, durante o qual foram registadas as temperaturas em vários pontos dos circuitos e os caudais de circulação. A evolução temporal da quantidade de calor transferida no evaporador, assim como, a comparação do coeficiente global de transferência de calor em condições ideias e experimentais, permitiu verificar que a razão U/U0 para o evaporador da bomba de calor não teve um comportamento decrescente ao longo do período de ensaio, permitindo concluir que, nas condições operatórias da experiência, não ocorreu sujamento na superfície do evaporador. No estudo de corrosão do cobre quando exposto à água residual em questão, obteve-se, para a velocidade de corrosão, o valor de 1,56 mg/(dm2 .dia), indicando assim que a corrosão do cobre naquele meio é praticamente inexistente.
Resumo:
Sediment oxygen demand (SOD) can be a significant oxygen sink in various types of water bodies, particularly slow-moving waters with substantial organic sediment accumulation. In most settings where SOD is a concern, the prevailing hydraulic conditions are such that the impact of sediment resuspension on SOD is not considered. However, in the case of Bubbly Creek in Chicago, Illinois, the prevailing slack water conditions are interrupted by infrequent intervals of very high flow rates associated with pumped combined sewer overflow (CSO) during intense hydrologic events. These events can cause resuspension of the highly organic, nutrient-rich bottom sediments, resulting in precipitous drawdown of dissolved oxygen (DO) in the water column. While many past studies have addressed the dependence of SOD on near-bed velocity and bed shear stress prior to the point of sediment resuspension, there has been limited research that has attempted to characterize the complex and dynamic phenomenon of resuspended-sediment oxygen demand. To address this issue, a new in situ experimental apparatus referred to as the U of I Hydrodynamic SOD Sampler was designed to achieve a broad range of velocities and associated bed shear stresses. This allowed SOD to be analyzed across the spectrum of no sediment resuspension associated with low velocity/ bed shear stress through full sediment resuspension associated with high velocity / bed shear stress. The current study split SOD into two separate components: (1) SODNR is the sediment oxygen demand associated with non-resuspension conditions and is a surface sink calculated using traditional methods to yield a value with units (g/m2/day); and (2) SODR is the oxygen demand associated with resuspension conditions, which is a volumetric sink most accurately characterized using non-traditional methods and units that reflect suspension in the water column (mg/L/day). In the case of resuspension, the suspended sediment concentration was analyzed as a function of bed shear stress, and a formulation was developed to characterize SODR as a function of suspended sediment concentration in a form similar to first-order biochemical oxygen demand (BOD) kinetics with Monod DO term. The results obtained are intended to be implemented into a numerical model containing hydrodynamic, sediment transport, and water quality components to yield oxygen demand varying in both space and time for specific flow events. Such implementation will allow evaluation of proposed Bubbly Creek water quality improvement alternatives which take into account the impact of SOD under various flow conditions. Although the findings were based on experiments specific to the conditions in Bubbly Creek, the techniques and formulations developed in this study should be applicable to similar sites.
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher