104 resultados para Esofago - Estenose
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The biomagnetic techniques use different magnetic field detectors to measure parameters of the human physiology. Those techniques present the advantage of being noninvasive and radiation free. Among them we can show up the Superconducting Quantum Interference Device (SQUID), the Current Alternate Biosusceptometry (ACB) and, more recently, the employment of anisotropic magnetoresistive sensors. Those magnetic sensors have a low cost and good sensitivity to measure different physiological parameters using magnetic markers. The biomagnetic techniques have being used successfully through study on the characteristics of the gastrointestinal tract. Recent research, the magnetoresistors were used to evaluate the transit time and localization of magnetic sources in different parts of the gastrointestinal tract. The objective of this work is the characterization, with in vitro tests, of a biomagnetic instrumentation using two 3-axis magnetoresistors arranged in a gradiometric coplanar setup to evaluate esophageal transit time, analyze and compare the results of experimental signals and the magnetic theory, as well as evaluate the instrumentation gain with use of tri-axial sensor front to the mono-axial sensor. The instrumentation is composed by two three-axis sensing magnetometers, precision power supply and amplifier electronic circuits. The sensors fixed in a coplanar setup were separate by distance of 18 cm. The sensitivity tests had been carried through using a cylindrical magnet (ø = 4 mm and h = 4 mm) of neodymium-iron-boron (grid 35). The tests were done moving the permanent magnet on the sensors parallel axis, simulating the food transit in... (Complete abstract click electronic access below)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Atherosclerosis is a chronic inflammatory disease characterized by accumulation of lipid and fibrous components in arterial vessels, giving rise to atheromas. Development of Atheromatou plaques leads to arterial steatosis, triggering ischemic events. Atherotrombosis has a strong correlation with atherosclerosis, where rupture of atheromatous plaques cause release of vessel wall's pro-thrombotic components, activating platelet aggregation and thromosis. Due to the major role played by platelets on thrombus-embolic conditions, drugs that inhibit platelet aggregation demonstrate great relevance for atherothrombosis prevention, reducing patient mortality. Currently, there are a variety of drugs acting on several different targets, preventing platelet activation. However, these therapies demosntrate side effects such as thrombocytopenia, neutropenia, hemorrhage and low oral availability. Thus, the application of molecular modifications such as hybridization can produce novel, more efficient antiplatelet aggregation inhibitors. In this project we describe the synthesis and characterization of novel N-acilhydrazone compounds, acting through multiple mechanisms such as platelet calcium chelation and nitric oxide donation by furoxanic subunits. Furthermore, we demonstrate that such compounds exhibit biological activity in in vivo bleeding time, in vitro antiplatelet aggregation and in vivo antinociceptive assays. Therefore, novel N-acilhydrazone compounds demonstrate potential as antiplatelet drugs for atherothrombosis prevention.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Endovascular aortic aneurysm repair (EVAR) involving renal and visceral arteries remains a great challenge. Several techniques have been developed over the time to treat juxtarenal, pararenal and thoracoabdominal aneurysms, highlighting the fenestrated and branched endografts, parallel prostheses as Chimney, Periscope and Sandwich Techniques and the use of flow modulation by multilayer stent. We report a case of saccular juxtarenal aortic aneurysm with high surgical risk for complex airway access due to a history of radical laryngectomy for laryngeal neoplasm. Due to chronic aorto-iliac obstructive disease, ostial stenosis of renal artery and limited diameter of the suprarenal aorta, we discarded options involving fenestrated/branched endografts and involving parallel prostheses techniques. We present this case as a therapeutic challenge and a successful treatment option in the short-term evaluation.