973 resultados para Error in substance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Attention deficit/hyperactivity disorder (ADHD) is an increasingly recognized comorbid condition in subjects with substance use disorders (SUDs). This paper describes the methods and study population of the International ADHD in Substance Use Disorders Prevalence (IASP) study. Objectives of the IASP are to determine the prevalence of ADHD in adult treatment seeking patients with SUD in different countries and SUD populations, determine the reliability and validity of the Adult ADHD Self-report Scale V 1.1 (ASRS) as ADHD screening instrument in SUD populations, investigate the comorbidity profile of SUD patients with and without ADHD, compare risk factors and protective factors in SUD patients with and without a comorbid diagnosis of ADHD, and increase our knowledge about the relationship between ADHD and the onset and course of SUD. In this cross-sectional, multi-centre two stage study, subjects were screened for ADHD with the ASRS, diagnosed with the Conner's Adult ADHD Diagnostic Interview for DSM-IV (CAADID), and evaluated for SUD, major depression, bipolar disorder, anti social personality disorder and borderline personality disorder. Three thousand five hundred and fifty-eight subjects from 10 countries were included. Of these 40.9% screened positive for ADHD. This is the largest international study on this population evaluating ADHD and comorbid disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The staff of 20 substance abuse treatment facilities were administered the Ward Atmosphere Scale, an instrument which measures treatment environment. Ten facilities were freestanding and ten were hospital based, and were drawn from a large, not-for-profit national chain using a random selection process. Controlling for several staff and facility attributes, it was found that no substantial effects on treatment environment existed due to facility type, freestanding or hospital-based. Implications of the study exist in selection of facility type for purchasers of substance abuse treatment and for the hiring and training of clinical staff for treatment facilities. Study findings also suggest that inadequate or insufficient measures exist to examine the construct 'treatment environment'. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The prevalence of ADHD among patients with substance use disorder (SUD) is substantial. This study addressed the following research questions: Are early developmental, temperamental and educational problems overrepresented among SUD patients with ADHD compared to SUD patients without ADHD? Do this comorbid group receive early help for their ADHD, and are there signs of self-medicating with illicit central stimulants? Method: An international, multi-centre cross-sectional study was carried out involving seven European countries, with 1205 patients in treatment for SUD. The mean age was 40 years and 27% of the sample was female. All par- ticipants were interviewed with the Mini International Neuropsychiatric Interview Plus and the Conners' Adult ADHD Diagnostic Interview for DSM-IV. Results: SUD patients with ADHD (n = 196; 16.3% of the total sample) had a significantly slower infant develop- ment than SUD patients without ADHD (n = 1,009; 83.4%), had greater problems controlling their temperament, and had lower educational attainment. Only 24 (12%) of the current ADHD positive patients had been diagnosed and treated during childhood and/or adolescence. Finally, SUD patients with ADHD were more likely to have central stimulants or cannabis as their primary substance of abuse, whereas alcohol use was more likely to be the primary substance of abuse in SUD patients without ADHD. Conclusion: The results emphasize the importance of early identification of ADHD and targeted interventions in the health and school system, as well as in the addiction field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The readout procedure of charge-coupled device (CCD) cameras is known to generate some image degradation in different scientific imaging fields, especially in astrophysics. In the particular field of particle image velocimetry (PIV), widely extended in the scientific community, the readout procedure of the interline CCD sensor induces a bias in the registered position of particle images. This work proposes simple procedures to predict the magnitude of the associated measurement error. Generally, there are differences in the position bias for the different images of a certain particle at each PIV frame. This leads to a substantial bias error in the PIV velocity measurement (~0.1 pixels). This is the order of magnitude that other typical PIV errors such as peak-locking may reach. Based on modern CCD technology and architecture, this work offers a description of the readout phenomenon and proposes a modeling for the CCD readout bias error magnitude. This bias, in turn, generates a velocity measurement bias error when there is an illumination difference between two successive PIV exposures. The model predictions match the experiments performed with two 12-bit-depth interline CCD cameras (MegaPlus ES 4.0/E incorporating the Kodak KAI-4000M CCD sensor with 4 megapixels). For different cameras, only two constant values are needed to fit the proposed calibration model and predict the error from the readout procedure. Tests by different researchers using different cameras would allow verification of the model, that can be used to optimize acquisition setups. Simple procedures to obtain these two calibration values are also described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To validate clinically an algorithm for correcting the error in the keratometric estimation of corneal power by using a variable keratometric index of refraction (nk) in a normal healthy population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"October 20, 1954"