995 resultados para Environmental Noise
TDEM survey in urban environmental for hydrogeological study at USP campus in Sao Paulo city, Brazil
Resumo:
In this work, some TDEM (Time Domain Electromagnetic) results at USP (University of Sao Paulo) campus in Sao Paulo city, Brazil, are presented. The data were acquired focusing on two mains objectives: (i) to map geoelectrical stratigraphy of Sao Paulo sedimentary basin, emphasizing on hydrogeological studies about sedimentary and crystalline aquifers, and (ii) to analyze the viability of TDEM data acquisition use in urban environment. The study area is located in Sao Paulo basin border, characterized by Resende and Sao Paulo formations, which are constituted by sand-clays sediments over a granite-gneissic basement. Two equipments were used in order to acquire database: Protem47 (low power), and Protem57-MK2 (high power). Capacitive noise affect obtained data with Protem47 due to the presence of metal pipes buried at IAG/USP (Institute of Astronomy, Geophysics, and Atmospheric Science) test site at USP. On the other hand, capacitive noise did not affect acquired data with Protem57-MK2, and the data present high signal to noise ratio. Surveys helped in determining sedimentary and crystalline aquifers, characterized by a fracture zone with water inside basin basement (conductive zone). Results show good agreement with local geology obtained from lithological boreholes located in the study areas. Moreover, it shows that TDEM method can be used in urban environments with a countless potential in hydrogeological studies, offering great reliability. Studies showed that main TDEM-method limitation at USP was the lack of space for opening the transmitter loop. Results are very promising and open new perspectives for TDEM-method use in urban environments as this area remains unexplored. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
OBJECTIVE: To analyze the association between noise levels present in preschool institutions and vocal disorders among educators. METHODS: Cross-sectional study conducted in 2009 with 28 teachers from three preschool institutions located in the city of Sao Paulo (Southeastern Brazil). Sound pressure levels were measured according to Brazilian Technical Standards Association, with the use of a sound level meter. The averages were classified according to the levels of comfort, discomfort, and auditory damage proposed by the Pan American Health Organization. The educators underwent voice evaluation: self-assessment with visual analogue scale, auditory perceptual evaluation using the GRBAS scale, and acoustic analysis utilizing the Praat program. To analyze the association between noise and voice evaluation, descriptive statistics and the chi-square test were employed, with significance of 10% due to sample size. RESULTS: The teachers' age ranged between 21 and 56 years. The noise average was 72.7 dB, considered as damage 2. The professionals' vocal self-assessment ranked an average of 5.1 on the scale, being considered as moderate alteration. In the auditory-perceptual assessment, 74% presented vocal alteration, especially hoarseness; of these, 52% were considered mild alterations. In the acoustic assessment the majority presented fundamental frequency below the expected level. Averages for jitter, shimmer and harmonic-noise ratio showed alterations. An association between the presence of noise between the harmonics and vocal disorders was observed. CONCLUSIONS: There is an association between presence of noise between the harmonics and vocal alteration, with high noise levels. Although most teachers presented mild voice alteration, the self-evaluation showed moderate alteration, probably due to the difficulty in projection.
Resumo:
Within this PhD thesis several methods were developed and validated which can find applicationare suitable for environmental sample and material science and should be applicable for monitoring of particular radionuclides and the analysis of the chemical composition of construction materials in the frame of ESS project. The study demonstrated that ICP-MS is a powerful analytical technique for ultrasensitive determination of 129I, 90Sr and lanthanides in both artificial and environmental samples such as water and soil. In particular ICP-MS with collision cell allows measuring extremely low isotope ratios of iodine. It was demonstrated that isotope ratios of 129I/127I as low as 10-7 can be measured with an accuracy and precision suitable for distinguishing sample origins. ICP-MS with collision cell, in particular in combination with cool plasma conditions, reduces the influence of isobaric interferences on m/z = 90 and is therefore well-suited for 90Sr analysis in water samples. However, the applied ICP-CC-QMS in this work is limited for the measurement of 90Sr due to the tailing of 88Sr+ and in particular Daly detector noise. Hyphenation of capillary electrophoresis with ICP-MS was shown to resolve atomic ions of all lanthanides and polyatomic interferences. The elimination of polyatomic and isobaric ICP-MS interferences was accomplished without compromising the sensitivity by the use of a high resolution mode as available on ICP-SFMS. Combination of laser ablation with ICP-MS allowed direct micro and local uranium isotope ratio measurements at the ultratrace concentrations on the surface of biological samples. In particular, the application of a cooled laser ablation chamber improves the precision and accuracy of uranium isotopic ratios measurements in comparison to the non-cooled laser ablation chamber by up to one order of magnitude. In order to reduce the quantification problem, a mono gas on-line solution-based calibration was built based on the insertion of a microflow nebulizer DS-5 directly into the laser ablation chamber. A micro local method to determine the lateral element distribution on NiCrAlY-based alloy and coating after oxidation in air was tested and validated. Calibration procedures involving external calibration, quantification by relative sensitivity coefficients (RSCs) and solution-based calibration were investigated. The analytical method was validated by comparison of the LA-ICP-MS results with data acquired by EDX.
Resumo:
A design can be defined as context-sensitive when it achieves effective technical and functional transportation solutions, while preserving and enhancing natural environments and minimizing impacts on local communities. Traffic noise is one of the most critical environmental impacts of transportation infrastructure and it affects both humans and ecosystems. Tire/pavement noise is caused by a set of interactions at the contact patch and it is the predominant source of road noise at the regular traffic speeds. Wearing course characteristics affect tire/pavement noise through various mechanisms. Furthermore, acoustic performance of road pavements varies over time and it is influenced by both aging and temperature. Three experimentations have been carried out to evaluate wearing course characteristics effects on tire/pavement noise. The first study involves the evaluation of skid resistance, surface texture and tire/pavement noise of an innovative application of multipurpose cold-laid microsurfacing. The second one involves the evaluation of the surface and acoustic characteristics of the different pavement sections of the test track of the Centre for Pavement and Transportation Technology (CPATT) at the University of Waterloo. In the third study, a set of highway sections have been selected in Southern Ontario with various types of pavements. Noise measurements were carried out by means of the Statistical Pass-by (SPB) method in the first case study, whereas in the second and in the third one, Close-proximity (CPX) and the On-Board Sound Intensity (OBSI) methods have been performed in parallel. Test results have contributed to understand the effects of pavement materials, temperature and aging on tire/pavement noise. Negligible correlation was found between surface texture and roughness with noise. As a general trend, aged and stiffer materials have shown to provide higher noise levels than newer and less stiff ones. Noise levels were also observed to be higher with temperature increase.
Why do users care about their noise emissions? Explaining the intention to reduce road traffic noise
Resumo:
Road-traffic noise impairs the well-being and health of many people. Motivating car drivers to voluntarily adopt a low-noise driving style (i.e., eco-driving) contributes to the reduction of road-traffic noise, complementary to requirements, bans, and laws. In a field study with employees of a municipality (N = 88), we investigated the effects of an intervention on car drivers’ motivation to prevent road-traffic noise, motivation to practice eco-driving, and driving behavior. The intervention consisted of a leaflet intended to enhance participants’ motivation, a practical eco-driving course, and weekly driving-performance feedbacks. We used a switching-replications design with two intervention groups. In both groups, eco-driving behavior was significantly strengthened by the intervention. The effects on the motivational variables were significant in only one of the groups (however, it should be noted that the average motivation was already relatively high before the intervention). For one of the groups, the study design allowed testing for the effects at an additional follow-up assessment (4 months after the intervention). The results showed that the intervention effect on driving behavior held across this period. The findings of the present research suggest that it is possible to improve car driver’s behavior with regard to a low-noise driving style.
Resumo:
Background Magnetoencephalography (MEG) provides a direct measure of brain activity with high combined spatiotemporal resolution. Preprocessing is necessary to reduce contributions from environmental interference and biological noise. New method The effect on the signal-to-noise ratio of different preprocessing techniques is evaluated. The signal-to-noise ratio (SNR) was defined as the ratio between the mean signal amplitude (evoked field) and the standard error of the mean over trials. Results Recordings from 26 subjects obtained during and event-related visual paradigm with an Elekta MEG scanner were employed. Two methods were considered as first-step noise reduction: Signal Space Separation and temporal Signal Space Separation, which decompose the signal into components with origin inside and outside the head. Both algorithm increased the SNR by approximately 100%. Epoch-based methods, aimed at identifying and rejecting epochs containing eye blinks, muscular artifacts and sensor jumps provided an SNR improvement of 5–10%. Decomposition methods evaluated were independent component analysis (ICA) and second-order blind identification (SOBI). The increase in SNR was of about 36% with ICA and 33% with SOBI. Comparison with existing methods No previous systematic evaluation of the effect of the typical preprocessing steps in the SNR of the MEG signal has been performed. Conclusions The application of either SSS or tSSS is mandatory in Elekta systems. No significant differences were found between the two. While epoch-based methods have been routinely applied the less often considered decomposition methods were clearly superior and therefore their use seems advisable.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.