984 resultados para Electronic portal imaging device


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As part of the primary survey, polytrauma patients in our emergency department are examined using the new 'Lodox Statscan' (LS) digital low-radiation imaging device. The LS provides full-body anterior and lateral views based on enhanced linear slot-scanning technology, in accordance with the recommended Advanced Trauma Life Support (ATLS) Guidelines. This study's objectives were to establish whether LS appropriately rules out peripheral bone injuries and to examine whether LS imaging provides adequate information for the preoperative planning of such lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ATLS Guidelines recommend single plain radiography of the chest and pelvis as part of the primary survey. Such isolated radiographs, usually obtained by bedside machines, can result in limited, low-quality studies that can adversely affect management. A new digital, low-radiation imaging device, the "Lodox Statscan" (LS), provides full-body anterior and lateral views based on enhanced linear slot-scanning technology in just over 5 minutes. We have the first LS in Europe at our facility. The aim of this study was to compare LS with computed tomographic (CT) scanning, as the gold standard, to determine the sensitivity of LS investigation in detecting injuries to the chest, thoracolumbar spine, and pelvis from our own experience, and to compare our findings with those of conventional radiography in the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, devices that monitor the health of structures consume a lot of power and need a lot of time to acquire, process, and send the information about the structure to the main processing unit. To decrease this time, fast electronic devices are starting to be used to accelerate this processing. In this paper some hardware algorithms implemented in an electronic logic programming device are described. The goal of this implementation is accelerate the process and diminish the information that has to be send. By reaching this goal, the time the processor needs for treating all the information is reduced and so the power consumption is reduced too.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Implicit Association Test (IAT) has succeeded in accessing mental phenomena hardly exposed through self-report and explicit measures well known in the traditional studies on psychology. Although this measurement technique is among the most consistent in international publications, the few articles in Brazil have not deepened on theoretical issues that underlie the practice. This created a gap between the spread of this measure in the country and the production seen in international laboratories, both at quantitative and qualitative terms. In this context, the online labs implemented in several countries, including Brazil, created unique opportunities to overcome these disparities. Our work sought theoretical and conceptual clarification, contextualized to the historical development of the IAT and its online version, displaying affordably an unprecedented presentation of the virtual tool adapted to the Brazilian public. In a second step, we investigated empirically the data obtained by the Brazilian electronic portal "Countries", analyzing the degree of implicit and explicit nationalism of 2271 Brazilian subjects collected from early 2009 to late 2014. Our goal was to determine whether the data results obtained in a time of major sporting confrontation (FIFA World Cup 2010 and 2014) differ from periods when the tournament did not happen. Analyzes showed differences on the eve of the sporting confrontation, when the increase in the implicit nationalism was clearly superior, even with no effect by self-reports. In an independent analysis of a cultural context, there is an oscillation of explicit nationalism over the years, but not for the implicit action. In addition, it was found in women greater degree of implicit and explicit nationalism than in men, with both sexes presenting their preferences towards Brazil. In an end section, we suggest that nationalism may be a by-product of universal mental mechanisms that evolved to identify of the belonging group categorization, corroborating with the group favoritism. We propose that the intensification of the group preference on the eve of the competition has as its ancestral function strengthen the cohesion of the group in preparation to confrontational situations. We pointed out the need for studies on the differences between the sexes in matters relating to group membership belonging. It was expected largest nationalist attitudes in men reflecting the maintenance of cohesive groups in ancient societies. Thus, it appears a singular importance impart the traditional TAI studies with its online version for future investigations of human behavior in various areas of knowledge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Implicit Association Test (IAT) has succeeded in accessing mental phenomena hardly exposed through self-report and explicit measures well known in the traditional studies on psychology. Although this measurement technique is among the most consistent in international publications, the few articles in Brazil have not deepened on theoretical issues that underlie the practice. This created a gap between the spread of this measure in the country and the production seen in international laboratories, both at quantitative and qualitative terms. In this context, the online labs implemented in several countries, including Brazil, created unique opportunities to overcome these disparities. Our work sought theoretical and conceptual clarification, contextualized to the historical development of the IAT and its online version, displaying affordably an unprecedented presentation of the virtual tool adapted to the Brazilian public. In a second step, we investigated empirically the data obtained by the Brazilian electronic portal "Countries", analyzing the degree of implicit and explicit nationalism of 2271 Brazilian subjects collected from early 2009 to late 2014. Our goal was to determine whether the data results obtained in a time of major sporting confrontation (FIFA World Cup 2010 and 2014) differ from periods when the tournament did not happen. Analyzes showed differences on the eve of the sporting confrontation, when the increase in the implicit nationalism was clearly superior, even with no effect by self-reports. In an independent analysis of a cultural context, there is an oscillation of explicit nationalism over the years, but not for the implicit action. In addition, it was found in women greater degree of implicit and explicit nationalism than in men, with both sexes presenting their preferences towards Brazil. In an end section, we suggest that nationalism may be a by-product of universal mental mechanisms that evolved to identify of the belonging group categorization, corroborating with the group favoritism. We propose that the intensification of the group preference on the eve of the competition has as its ancestral function strengthen the cohesion of the group in preparation to confrontational situations. We pointed out the need for studies on the differences between the sexes in matters relating to group membership belonging. It was expected largest nationalist attitudes in men reflecting the maintenance of cohesive groups in ancient societies. Thus, it appears a singular importance impart the traditional TAI studies with its online version for future investigations of human behavior in various areas of knowledge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient’s medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method.

Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three approaches were applied in this research for dosimetric evaluation on CT images with severe metal artefacts. The first part of the research used a water phantom with four iodine syringes. Two sets of plans, multi-arc plans and single-arc plans, using the Volumetric Modulated Arc therapy (VMAT) technique were designed to avoid or minimize influences from high-density objects. The second part of the research used projection-based MAR Algorithm and the Dual-Energy Method. Calculated Doses (Mean, Minimum, and Maximum Doses) to the planning treatment volume (PTV) were compared and homogeneity index (HI) calculated.

Results: (1) Without the GSI-based MAR application, a percent error between mean dose and the absolute dose ranging from 3.4-5.7% per fraction was observed. In contrast, the error was decreased to a range of 0.09-2.3% per fraction with the GSI-based MAR algorithm. There was a percent difference ranging from 1.7-4.2% per fraction between with and without using the GSI-based MAR algorithm. (2) A range of 0.1-3.2% difference was observed for the maximum dose values, 1.5-10.4% for minimum dose difference, and 1.4-1.7% difference on the mean doses. Homogeneity indexes (HI) ranging from 0.068-0.065 for dual-energy method and 0.063-0.141 with projection-based MAR algorithm were also calculated.

Conclusion: (1) Percent error without using the GSI-based MAR algorithm may deviate as high as 5.7%. This error invalidates the goal of Radiation Therapy to provide a more precise treatment. Thus, GSI-based MAR algorithm was desirable due to its better dose calculation accuracy. (2) Based on direct numerical observation, there was no apparent deviation between the mean doses of different techniques but deviation was evident on the maximum and minimum doses. The HI for the dual-energy method almost achieved the desirable null values. In conclusion, the Dual-Energy method gave better dose calculation accuracy to the planning treatment volume (PTV) for images with metal artefacts than with or without GE MAR Algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: Students who are actively involved in the learning process tend to develop deeper knowledge than those in traditional lecture classrooms (Beatty, 2007; Crouch & Mazur, 2001; Hake, 1998; Richardson, 2003). An instructional strategy that promotes active involvement is Peer Instruction. This strategy encourages student engagement by asking them to respond to conceptual multiple-choice questions intermittently throughout the lecture. These questions can be responded to by using an electronic hand-held device commonly known as a clicker that enables students’ responses to be displayed on a screen. When clickers are not available, a show of hands or other means can be used. The literature suggests that the impact on student learning is the same, whether the teacher uses clickers or simply asks students to raise their hand or use flashcards when responding to the questions (Lasry, 2007). This critical analysis argues that using clickers to respond to these in-class conceptual multiple-choice questions as opposed to using a show of hands leads to deeper conceptual understanding, better performance on tests, and greater overall enjoyment during class.||Résumé: Les étudiants qui sont activement impliqués dans le processus d'apprentissage ont tendance à développer des connaissances plus approfondies que lors de cours traditionnels (Beatty, 2007; Crouch & Mazur, 2001; Hake, 1998; Richardson, 2003). Une stratégie d'enseignement qui favorise la participation active est l’apprentissage par les pairs. Cette stratégie d’enseignement encourage l'engagement des élèves en leur demandant de répondre à des questions à choix multiples conceptuelles à plusieurs reprises durant le déroulement du cours. Ces questions peuvent être répondues à l'aide d'un appareil portatif électronique (un « clicker ») qui permet d’afficher de façon anonyme les réponses des élèves sur un écran. Si les clickers ne sont pas disponibles, les étudiants peuvent aussi répondre aux questions en levant la main. La littérature suggère que la méthode utilisée n’a pas d’impact sur l'apprentissage des élèves, que l'enseignant utilise des clickers, des flashcards ou qu’il demande simplement aux élèves de lever la main pour répondre aux questions (Lasry, 2007). Cette analyse critique fait valoir que l'utilisation de clickers pour répondre à ces questions à choix multiples conceptuelles en classe, plutôt que de faire lever la main aux étudiants, résulte en une compréhension conceptuelle plus approfondie, une meilleure performance aux examens et plus de plaisir pendant les cours.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A novel method to fabricate chemically linked conducting polymer–biopolymer composites that are intrinsically flexible and conducting for functional electrode applications is presented. Polypyrrole was synthesised in situ during the cellulose regeneration process using the 1-butyl-3-methylimidazolium chloride ionic liquid as a solvent medium. The obtained polypyrrole–cellulose composite was chemically blended and showed flexible polymer properties while retaining the electronic properties of a conducting polymer. Addition of an ionic liquid such as trihexyl(tetradecyl)phosphonium bis(trifluoromethylsulfonyl)imide, enhanced the flexibility of the composite. The functional application of these materials in the electrochemically controlled release of a model drug has been demonstrated. This strategy opens up a new design for a wide spectrum of materials for smart electronic device applications wherein the functionality of doping and de-doping of conducting polymers is retained and their processability issue is addressed by exploiting an ionic liquid route.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In GaAs-based pseudomorphic high-electron mobility transistor device structures, strain and composition of the InxGa1 (-) As-x channel layer are very important as they influence the electronic properties of these devices. In this context, transmission electron microscopy techniques such as (002) dark-field imaging, high-resolution transmission electron microscopy (HRTEM) imaging, scanning transmission electron microscopy-high angle annular dark field (STEM-HAADF) imaging and selected area diffraction, are useful. A quantitative comparative study using these techniques is relevant for assessing the merits and limitations of the respective techniques. In this article, we have investigated strain and composition of the InxGa1 (-) As-x layer with the mentioned techniques and compared the results. The HRTEM images were investigated with strain state analysis. The indium content in this layer was quantified by HAADF imaging and correlated with STEM simulations. The studies showed that the InxGa1 (-) As-x channel layer was pseudomorphically grown leading to tetragonal strain along the 001] growth direction and that the average indium content (x) in the epilayer is similar to 0.12. We found consistency in the results obtained using various methods of analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, polymer diode performance was analyzed by using nickel as anode electrode from two kinds of nickel as starting materials, namely nickel wire Ni{B} and nickel nano-particle Ni{N}. Metal electrode surface roughness and grain morphology were investigated by atomic force microscope and scanning electron microscope, respectively. Current-voltage (I-V) and capacitance-voltage (C-V) characteristics were measured for the fabricated device at room temperature. Obtained result from the current-voltage characteristics shows an increment in the current density for nickel nano-particle top electrode device. The increase in the current density could be due to a reduction in built-in voltage at P3HT/Ni{N} interface.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report a technique which can be used to improve the accuracy of infrared (IR) surface temperature measurements made on MEMS (Micro-Electro-Mechanical- Systems) devices. The technique was used to thermally characterize a SOI (Silicon-On-Insulator) CMOS (Complementary Metal Oxide Semiconductor) MEMS thermal flow sensor. Conventional IR temperature measurements made on the sensor were shown to give significant surface temperature errors, due to the optical transparency of the SiO 2 membrane layers and low emissivity/high reflectivity of the metal. By making IR measurements on radiative carbon micro-particles placed in isothermal contact with the device, the accuracy of the surface temperature measurement was significantly improved. © 2010 EDA Publishing/THERMINIC.