874 resultados para Electronic data processing departments
Resumo:
The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Nowadays, L1 SBAS signals can be used in a combined GPS+SBAS data processing. However, such situation restricts the studies over short baselines. Besides of increasing the satellite availability, SBAS satellites orbit configuration is different from that of GPS. In order to analyze how these characteristics can impact GPS positioning in the southeast area of Brazil, experiments involving GPS-only and combined GPS+SBAS data were performed. Solutions using single point and relative positioning were computed to show the impact over satellite geometry, positioning accuracy and short baseline ambiguity resolution. Results showed that the inclusion of SBAS satellites can improve the accuracy of positioning. Nevertheless, the bad quality of the data broadcasted by these satellites limits their usage. © Springer-Verlag Berlin Heidelberg 2012.
Resumo:
El Sub-Programa de Documentacion en Poblacion y Procesamiento de Datos del CELADE se compone de tres elementos que corresponden a los primeros objetivos inmediatos del mismo: el Sistema de Documentacion en Poblacion para America Latina (DOCPAL), el Banco de Datos y la Unidad de Procesamiento de Informacion. El presente documento describe los objetivos, antecedentes y justificacion de cada uno de estos tres nucleos, asi como las actividades contempladas para el periodo 1980-1983 y que fundamentan el presupuesto contenido en la solicitud de fondos al UNFPA
Resumo:
This issue describes progress in EDI in Argentina, Brazil, Chile, Mexico, the United States and Venezuela up to August 1996. The information is based on the progress reports prepared by country representatives for the Pan-American EDIFACT Board (PAEB), which coordinates EDI development activities in the Americas.
Resumo:
Every port is unique. Although all ports exist for the same basic purpose (to act as an interface in the transfer from one mode of transport to another), no two are ever organized in the same way.Ports may be classified according to: Physical conditions: location (geographical position, man-made or natural harbour, estuary location, difficult weather conditions, tides, etc.) and size (large, small or medium-sized). Use: commercial (general cargo, bulk solids, bulk liquids, oil, break bulk, mixed), passenger, sport and leisure, fishing, mixed, etc. Ownership: private, municipal, regional or State-owned. The Port Authority's role in management of the port: Overall control, i.e. the Port Authority plans, sets up and operates the whole range of services. Facilitator, i.e. the Port Authority plans and sets up the infrastructure and the superstructure, but services are provided by private companies. Landlord, i.e. the Port Authority allows private companies to be responsible for the superstructure and provide port services. Different combinations of port types will therefore give rise to different kinds of organization and different information flows, which means that the associated information systems may differ significantly from port to port. Since this paper relates to the port of Barcelona, with its own specific characteristics, the contents may not always be applicable to other ports.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Methodological evaluation of the proteomic analysis of cardiovascular-tissue material has been performed with a special emphasis on establishing examinations that allow reliable quantitative analysis of silver-stained readouts. Reliability, reproducibility, robustness and linearity were addressed and clarified. In addition, several types of normalization procedures were evaluated and new approaches are proposed. It has been found that the silver-stained readout offers a convenient approach for quantitation if a linear range for gel loading is defined. In addition, a broad range of a 10-fold input (loading 20-200 microg per gel) fulfills the linearity criteria, although at the lowest input (20 microg) a portion of protein species will remain undetected. The method is reliable and reproducible within a range of 65-200 microg input. The normalization procedure using the sum of all spot intensities from a silver-stained 2D pattern has been shown to be less reliable than other approaches, namely, normalization through median or through involvement of interquartile range. A special refinement of the normalization through virtual segmentation of pattern, and calculation of normalization factor for each stratum provides highly satisfactory results. The presented results not only provide evidence for the usefulness of silver-stained gels for quantitative evaluation, but they are directly applicable to the research endeavor of monitoring alterations in cardiovascular pathophysiology.
Resumo:
Clinical Research Data Quality Literature Review and Pooled Analysis We present a literature review and secondary analysis of data accuracy in clinical research and related secondary data uses. A total of 93 papers meeting our inclusion criteria were categorized according to the data processing methods. Quantitative data accuracy information was abstracted from the articles and pooled. Our analysis demonstrates that the accuracy associated with data processing methods varies widely, with error rates ranging from 2 errors per 10,000 files to 5019 errors per 10,000 fields. Medical record abstraction was associated with the highest error rates (70–5019 errors per 10,000 fields). Data entered and processed at healthcare facilities had comparable error rates to data processed at central data processing centers. Error rates for data processed with single entry in the presence of on-screen checks were comparable to double entered data. While data processing and cleaning methods may explain a significant amount of the variability in data accuracy, additional factors not resolvable here likely exist. Defining Data Quality for Clinical Research: A Concept Analysis Despite notable previous attempts by experts to define data quality, the concept remains ambiguous and subject to the vagaries of natural language. This current lack of clarity continues to hamper research related to data quality issues. We present a formal concept analysis of data quality, which builds on and synthesizes previously published work. We further posit that discipline-level specificity may be required to achieve the desired definitional clarity. To this end, we combine work from the clinical research domain with findings from the general data quality literature to produce a discipline-specific definition and operationalization for data quality in clinical research. While the results are helpful to clinical research, the methodology of concept analysis may be useful in other fields to clarify data quality attributes and to achieve operational definitions. Medical Record Abstractor’s Perceptions of Factors Impacting the Accuracy of Abstracted Data Medical record abstraction (MRA) is known to be a significant source of data errors in secondary data uses. Factors impacting the accuracy of abstracted data are not reported consistently in the literature. Two Delphi processes were conducted with experienced medical record abstractors to assess abstractor’s perceptions about the factors. The Delphi process identified 9 factors that were not found in the literature, and differed with the literature by 5 factors in the top 25%. The Delphi results refuted seven factors reported in the literature as impacting the quality of abstracted data. The results provide insight into and indicate content validity of a significant number of the factors reported in the literature. Further, the results indicate general consistency between the perceptions of clinical research medical record abstractors and registry and quality improvement abstractors. Distributed Cognition Artifacts on Clinical Research Data Collection Forms Medical record abstraction, a primary mode of data collection in secondary data use, is associated with high error rates. Distributed cognition in medical record abstraction has not been studied as a possible explanation for abstraction errors. We employed the theory of distributed representation and representational analysis to systematically evaluate cognitive demands in medical record abstraction and the extent of external cognitive support employed in a sample of clinical research data collection forms. We show that the cognitive load required for abstraction in 61% of the sampled data elements was high, exceedingly so in 9%. Further, the data collection forms did not support external cognition for the most complex data elements. High working memory demands are a possible explanation for the association of data errors with data elements requiring abstractor interpretation, comparison, mapping or calculation. The representational analysis used here can be used to identify data elements with high cognitive demands.
Resumo:
In a series of attempts to research and document relevant sloshing type phenomena, a series of experiments have been conducted. The aim of this paper is to describe the setup and data processing of such experiments. A sloshing tank is subjected to angular motion. As a result pressure registers are obtained at several locations, together with the motion data, torque and a collection of image and video information. The experimental rig and the data acquisition systems are described. Useful information for experimental sloshing research practitioners is provided. This information is related to the liquids used in the experiments, the dying techniques, tank building processes, synchronization of acquisition systems, etc. A new procedure for reconstructing experimental data, that takes into account experimental uncertainties, is presented. This procedure is based on a least squares spline approximation of the data. Based on a deterministic approach to the first sloshing wave impact event in a sloshing experiment, an uncertainty analysis procedure of the associated first pressure peak value is described.