929 resultados para Edge detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to investigate the edge condition between the digital layers and the physical layers of the city and how tangible expressions of the interrelationships between them to create and define new experiences of place, creating hybrid place. To date there has been discussion and investigation into understanding the importance of place, similarly into defining hybrid space. This paper explores principles of place and space to question how they can be applied into defining and proposing the notion of hybrid place in urban environments. The integration of media spaces into architecture provide infrastructure for the development of hybrid place. The physical boundaries of urban spaces become blurred through the integration of media such as computer technologies connecting the physical environment with the digital. Literature and case studies that reflect the current trends of use of technology by people in space and place within urban environments are examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to develop a reliable density estimation method for signalised arterials based on cumulative counts from upstream and downstream detectors. In order to overcome counting errors associated with urban arterials with mid-link sinks and sources, CUmulative plots and Probe Integration for Travel timE estimation (CUPRITE) is employed for density estimation. The method, by utilizing probe vehicles’ samples, reduces or cancels the counting inconsistencies when vehicles’ conservation is not satisfied within a section. The method is tested in a controlled environment, and the authors demonstrate the effectiveness of CUPRITE for density estimation in a signalised section, and discuss issues associated with the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of visual speech recognition (VSR) systems are significantly influenced by the accuracy of the visual front-end. The current state-of-the-art VSR systems use off-the-shelf face detectors such as Viola- Jones (VJ) which has limited reliability for changes in illumination and head poses. For a VSR system to perform well under these conditions, an accurate visual front end is required. This is an important problem to be solved in many practical implementations of audio visual speech recognition systems, for example in automotive environments for an efficient human-vehicle computer interface. In this paper, we re-examine the current state-of-the-art VSR by comparing off-the-shelf face detectors with the recently developed Fourier Lucas-Kanade (FLK) image alignment technique. A variety of image alignment and visual speech recognition experiments are performed on a clean dataset as well as with a challenging automotive audio-visual speech dataset. Our results indicate that the FLK image alignment technique can significantly outperform off-the shelf face detectors, but requires frequent fine-tuning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to develop a reliable density estimation method for signalised arterials based on cumulative counts from upstream and downstream detectors. In order to overcome counting errors associated with urban arterials with mid-link sinks and sources, CUmulative plots and Probe Integration for Travel timE estimation (CUPRITE) is employed for density estimation. The method, by utilizing probe vehicles’ samples, reduces or cancels the counting inconsistencies when vehicles’ conservation is not satisfied within a section. The method is tested in a controlled environment, and the authors demonstrate the effectiveness of CUPRITE for density estimation in a signalised section, and discuss issues associated with the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neo-angiogenesis during neoplastic growth involves endothelial mitogenic and migration stimuli produced by cancer or tumour stromal cells. Although this active angiogenesis takes place in the tumour periphery, the process of vessel growth and survival in inner areas and its clinical role remain largely unexplored. The present study compared the microvessel score (MS) as well as the single endothelial cell score (ECS) in the invading edge and in inner areas of non-small cell lung carcinomas (NSCLCs). Three different patterns of vascular growth were distinguished: the edvin (edge vs. inner) type 1, where a low MS was observed in both peripheral and inner tumour areas; the edvin type 2, where a high MS was noted in the invading front but a low MS in inner areas; and the edvin type 3, where both peripheral and inner tumour areas had a high MS. The ECS was high in the invading edge in edvin type 2 and 3 cases and was sharply decreased in both types in inner areas, suggesting that endothelial cell migration is unlikely to contribute to the angiogenic process in areas away from the tumour front. Expression of the vascular endothelial growth factor (VEGF) and of thymidine phosphorylase (TP) was associated with a high MS in the invading edge. VEGF was associated with a high MS in inner areas (edvin 3), while TP expression was associated with edvin type 2, showing that VEGF (and not TP) contributes to the preservation of the inner vasculature. Both edvin type 2 and 3 cases showed an increased incidence of node metastasis, but edvin type 3 cases had a poorer prognosis, even in the N1-stage group. The present study suggests that tumour factors regulating angiogenesis and vascular survival are not identical. A possible method is reported to quantify these two parameters by comparing the MS in the invading edge and inner areas (edvin types). This observation may contribute to the evaluation of the effectiveness of different therapeutic approaches, namely vascular targeting vs. anti-angiogenesis. Copyright (C) 2000 John Wiley and Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Travel time estimation and prediction on motorways has long been a topic of research. Prediction modeling generally assumes that the estimation is perfect. No matter how good is the prediction modeling- the errors in estimation can significantly deteriorate the accuracy and reliability of the prediction. Models have been proposed to estimate travel time from loop detector data. Generally, detectors are closely spaced (say 500m) and travel time can be estimated accurately. However, detectors are not always perfect, and even during normal running conditions few detectors malfunction, resulting in increase in the spacing between the functional detectors. Under such conditions, error in the travel time estimation is significantly large and generally unacceptable. This research evaluates the in-practice travel time estimation model during different traffic conditions. It is observed that the existing models fail to accurately estimate travel time during large detector spacing and congestion shoulder periods. Addressing this issue, an innovative Hybrid model that only considers loop data for travel time estimation is proposed. The model is tested using simulation and is validated with real Bluetooth data from Pacific Motorway Brisbane. Results indicate that during non free flow conditions and larger detector spacing Hybrid model provides significant improvement in the accuracy of travel time estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain accurate Monte Carlo simulations of small radiation fields, it is important model the initial source parameters (electron energy and spot size) accurately. However recent studies have shown that small field dosimetry correction factors are insensitive to these parameters. The aim of this work is to extend this concept to test if these parameters affect dose perturbations in general, which is important for detector design and calculating perturbation correction factors. The EGSnrc C++ user code cavity was used for all simulations. Varying amounts of air between 0 and 2 mm were deliberately introduced upstream to a diode and the dose perturbation caused by the air was quantified. These simulations were then repeated using a range of initial electron energies (5.5 to 7.0 MeV) and electron spot sizes (0.7 to 2.2 FWHM). The resultant dose perturbations were large. For example 2 mm of air caused a dose reduction of up to 31% when simulated with a 6 mm field size. However these values did not vary by more than 2 % when simulated across the full range of source parameters tested. If a detector is modified by the introduction of air, one can be confident that the response of the detector will be the same across all similar linear accelerators and the Monte Carlo modelling of each machine is not required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Australian Government’s Skills for the Carbon Challenge (SCC) initiative aims to accelerate industry and the education sectors response to climate change. As part of the SCC initiative, the Department of Industry, Innovation, Climate Change, Science, Research and Tertiary Education (DIICCSRTE) provided funding to investigate the state of energy efficiency education in engineering-related Australian Technical and Further Education (TAFE) Programs. The following document reports on the outcomes of a multi-stage consultation project that engaged with participants from over 80% of TAFE institutions across Australia with the aim of supporting and enhancing future critical skills development in this area. Specifically, this report presents the findings of a national survey, based on a series of TAFE educator focus groups, conducted in May 2013 aimed at understanding the experiences and insights of Australian TAFE educators teaching engineering-related courses. Responses were received from 224 TAFE Educators across 50 of the 61 TAFE institutions in Australia (82% response rate).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moving cell fronts are an essential feature of wound healing, development and disease. The rate at which a cell front moves is driven, in part, by the cell motility, quantified in terms of the cell diffusivity $D$, and the cell proliferation rate �$\lambda$. Scratch assays are a commonly-reported procedure used to investigate the motion of cell fronts where an initial cell monolayer is scratched and the motion of the front is monitored over a short period of time, often less than 24 hours. The simplest way of quantifying a scratch assay is to monitor the progression of the leading edge. Leading edge data is very convenient since, unlike other methods, it is nondestructive and does not require labeling, tracking or counting individual cells amongst the population. In this work we study short time leading edge data in a scratch assay using a discrete mathematical model and automated image analysis with the aim of investigating whether such data allows us to reliably identify $D$ and $\lambda$�. Using a naıve calibration approach where we simply scan the relevant region of the ($D$;$\lambda$�) parameter space, we show that there are many choices of $D$ and $\lambda$� for which our model produces indistinguishable short time leading edge data. Therefore, without due care, it is impossible to estimate $D$ and $\lambda$� from this kind of data. To address this, we present a modified approach accounting for the fact that cell motility occurs over a much shorter time scale than proliferation. Using this information we divide the duration of the experiment into two periods, and we estimate $D$ using data from the first period, while we estimate �$\lambda$ using data from the second period. We confirm the accuracy of our approach using in silico data and a new set of in vitro data, which shows that our method recovers estimates of $D$ and $\lamdba$� that are consistent with previously-reported values except that that our approach is fast, inexpensive, nondestructive and avoids the need for cell labeling and cell counting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Established Monte Carlo user codes BEAMnrc and DOSXYZnrc permit the accurate and straightforward simulation of radiotherapy experiments and treatments delivered from multiple beam angles. However, when an electronic portal imaging detector (EPID) is included in these simulations, treatment delivery from non-zero beam angles becomes problematic. This study introduces CTCombine, a purpose-built code for rotating selected CT data volumes, converting CT numbers to mass densities, combining the results with model EPIDs and writing output in a form which can easily be read and used by the dose calculation code DOSXYZnrc...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of clearly separated vertical graphenenanosheets on silicon nanograss support is demonstrated. The plasma-enabled, two-stage mask-free process produced self-organized vertical graphenes of a few carbon layers (as confirmed by advanced microanalysis), prominently oriented in the substrate center–substrate edge direction. It is shown that the width of the alignment zone depends on the substrate conductivity, and thus the electric field in the vicinity of the growth surface is responsible for the graphene alignment. This finding is confirmed by the Monte Carlo simulations of the ion flux distribution in the silicon nanograss pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma-aided nanofabrication is a rapidly expanding area of research spanning disciplines ranging from physics and chemistry of plasmas and gas discharges to solid state physics, materials science, surface science, nanoscience and nanotechnology and related engineering subjects. The current status of the research field is discussed and examples of superior performance and competitive advantage of plasma processes and techniques are given. These examples are selected to represent a range of applications of two major types of plasmas suitable for nanoscale synthesis and processing, namely thermally non-equilibrium and thermal plasmas. Major concepts and terminology used in the field are introduced. The paper also pinpoints the major challenges facing plasma-aided nanofabrication and identifies some emerging topics for future research. © 2007 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Small field x-ray beam dosimetry is difficult due to a lack of lateral electronic equilibrium, source occlusion, high dose gradients and detector volume averaging. Currently there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods Small field sizes were defined by BrainLAB circular cones (4 – 30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated by Monte Carlo methods using BEAMnrc and correction factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Results For the small fields of 4 to 30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω_(Q_clin,Q_msr)^(f_clin,f_msr ), were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k_(Q_clin,Q_msr)^(f_clin,f_msr ), were derived for the PTW 60019 microDiamond detector. Conclusions We conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.