925 resultados para EYE ANOMALIES
Resumo:
Mestrado em Engenharia Computação e Instrumentação Médica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Astringency is an organoleptic property of beverages and food products resulting mainly from the interaction of salivary proteins with dietary polyphenols. It is of great importance to consumers, but the only effective way of measuring it involves trained sensorial panellists, providing subjective and expensive responses. Concurrent chemical evaluations try to screen food astringency, by means of polyphenol and protein precipitation procedures, but these are far from the real human astringency sensation where not all polyphenol–protein interactions lead to the occurrence of precipitate. Here, a novel chemical approach that tries to mimic protein–polyphenol interactions in the mouth is presented to evaluate astringency. A protein, acting as a salivary protein, is attached to a solid support to which the polyphenol binds (just as happens when drinking wine), with subsequent colour alteration that is fully independent from the occurrence of precipitate. Employing this simple concept, Bovine Serum Albumin (BSA) was selected as the model salivary protein and used to cover the surface of silica beads. Tannic Acid (TA), employed as the model polyphenol, was allowed to interact with the BSA on the silica support and its adsorption to the protein was detected by reaction with Fe(III) and subsequent colour development. Quantitative data of TA in the samples were extracted by colorimetric or reflectance studies over the solid materials. The analysis was done by taking a regular picture with a digital camera, opening the image file in common software and extracting the colour coordinates from HSL (Hue, Saturation, Lightness) and RGB (Red, Green, Blue) colour model systems; linear ranges were observed from 10.6 to 106.0 μmol L−1. The latter was based on the Kubelka–Munk response, showing a linear gain with concentrations from 0.3 to 10.5 μmol L−1. In either of these two approaches, semi-quantitative estimation of TA was enabled by direct eye comparison. The correlation between the levels of adsorbed TA and the astringency of beverages was tested by using the assay to check the astringency of wines and comparing these to the response of sensorial panellists. Results of the two methods correlated well. The proposed sensor has significant potential as a robust tool for the quantitative/semi-quantitative evaluation of astringency in wine.
Resumo:
This cross-sectional study assessed the grade of physical impairments in 61 individuals with leprosy receiving multidrug therapy (MDT) under the Brazilian Unified Health System (SUS), and residing in Campina Grande, Paraíba State, Brazil. Impairments were assessed using the disability grade (DG) standardized by the WHO, and the EHF score (Eye-Hand-Foot sum of impairment scores). Impairments were detected in 25 (41%) of the subjects. A total of 14 (23%) patients scored DG 1, while 11 (18%) were assigned DG 2. The EHF score ranged from 1 to 10 points in the group of patients with physical impairments, with a mean score of 3.6 points. The majority of individuals with impairments were affected in at least two sites. We conclude that the EHF score showed overlapping impairments in the segments examined and may be more appropriate than the DG classification system for describing the degree of physical impairment of leprosy patients.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação para Obtenção do grau de Mestrado em Arte e Ciência do Vidro
Resumo:
Objective: To report a case of retinal toxicity associated with efavirenz in an adult. Methods: We describe a case of gradual-onset blurry vision in both eyes in a 37-year-old HIV Caucasian woman, on antiretroviral therapy (ART), including efavirenz. Results: The patient presented with a best corrected visual acuity of 20/100 for the right eye (RE) and 20/125 for the left eye (LE). Fundoscopy revealed mottled atrophic changes of the macular retinal pigment epithelium (RPE) in both eyes. Fluorescein angiography revealed an annular pattern of RPE atrophy in both eyes. Full-field electretinography (ERG) was normal. Conclusions: Based on our patient’s history and on previous reports, efavirenz seems to be the culprit in this case. Our report provides evidence in support of routine ophthalmological evaluation of patients on efavirenz.
Resumo:
RESUMO: A retina é composta, entre outras estruturas, pelo epitélio pigmentar da retina (EPR)e pela coróide. A região central da retina denomina-se mácula, e é a zona mais afetada na degenerescência macular relacionada com a idade, a forma mais comum de degenerescência da retina. Nesta doença, a secreção de fatores de crescimento pelo EPR é afetada, nomeadamente a do fator de crescimento vascular endotelial (VEGF), e pouco se sabe ainda sobre os mecanismos moleculares conducentes a esta condição. A família de proteínas Rab GTPases está envolvida nas vias intracelulares de sinalização e tráfego membranares, essenciais na transdução de sinais extracelulares em respostas biológicas. A sua crucial importância nestes mecanismos levou-nos a considerar o seu potencial envolvimento nas vias de secreção do VEGF, e a questionar-nos se teriam algum papel regulador sobre as mesmas. O principal objetivo deste trabalho é identificar Rab GTPases importantes para as vias de secreção e endocitose do VEGF no EPR. Essa identificação ajudará a esclarecer a patogénese da degenerescência macular da retina, e poderá servir para uma procura mais direcionada de novos agentes terapêuticos. A caracterização de dois modelos in vitro do EPR, células primárias isoladas de murganho e a linha celular B6-RPE07,levou-nos a concluir que são ambos semelhantes. Contudo, a linha celular foi escolhida como protótipo do EPR por permitir o acesso a um número ilimitado de células. No decurso deste trabalho, desenvolvemos e caracterizámos uma biblioteca de ferramentas moleculares que nos permitiram reduzir os níveis proteicos das proteínas Rab GTPases, com base na tecnologia de ácido ribonucleico (ARN) de interferência. O papel das proteínas Rab GTPases na secreção do VEGF no EPR foi estudado com base no silenciamento de apenas uma proteína, ou combinando várias, segundo a sua localização e funções intracelulares descritas. Este trabalho permitiu-nos concluir que as proteínas Rab GTPases são importantes intervenientes no processo de secreção de VEGF pelo EPR, e confirmar dados anteriores que relatam o envolvimento de algumas Rab GTPases endocíticas no processo. Propomos ainda um novo modelo para a interação destas proteínas no EPR, e sugerimos que a Rab10 e a Rab14 atuam negativamente sobre a Rab8, controlando o seu funcionamento. Os nossos resultados evidenciam a importância das proteínas Rab GTPases na secreção do VEGF pelas células do EPR, e servem de base a futuros estudos que melhor procurem compreender este mecanismo e de que modo a sua alteração se relaciona com a degenerescência da retina.--------ABSTRACT: Retinal pigment epithelium (RPE) and choroid are components of the mammalian retina, of which the central region is called macula. The most common form of retinaldegeneration, age-related macular degeneration (AMD), involves primarily deregulation of growth factors secretion by the RPE. Very little is known about the molecular mechanisms that lead to impairment of RPE’s homeostatic intracellular processes, namely the secretion of vascular endothelial growth factor (VEGF). Rab GTPases’ family regulates membrane targeting and traffic, being essential in the transduction of signal pathways. Given Rab proteins’ role in intracellular trafficking, we propose to identify key regulatory Rab proteins involved in either the secretory or the recycling pathways of VEGF in RPE. Understanding how Rab proteins’ function disruption could lead to retinal and choroidal pathology would ultimately contribute to find new therapeutic agents. Here, we characterized two mouse RPE in vitro cell models, primary cells and B6-RPE07 cell line, and concluded that both display important epithelial features as the RPE presents in vivo. Considering unlimited cell number and results reproducibility, we chose B6-RPE07 cells to further study Rab proteins’ function. To scrutinize the consequences of Rab proteins’ absence or diminished levels, we have developed novel molecular tools to achieve silencing of these key proteins using miRNA technology. We further addressed the effect of Rab proteins’ absence on VEGF secretion by performing an extensive screening where different Rab proteins were silenced, both individually and in multiple combinations considering their cellular/ compartment location. We conclude that Rab GTPases are important intervenients in VEGF secretion by RPE cells, confirming endocytic Rab proteins’ role in regulation of VEGF biology. We also propose a novel model for Rab proteins’ interaction in RPE. Our results suggest that Rab10 and Rab14 might influence Rab8 in a negative feedback mechanism, important for controlling VEGF secretion. Our achievements’ unravel Rab proteins’ role in VEGF secretion by RPE cells and are the basis for future studies to better understand RPE molecular secretory machinery.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Master’s Double Degree in Finance and Financial Economics from NOVA – School of Business and Economics and Maastricht University
Resumo:
In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.
Resumo:
Morphological anomalies in phlebotomine sand flies are reviewed and updated with abnormalites observed in Venezuela on the species L. trinidadensis, L.shannoni, L. lichyi and L. gomezi, and the description of a teratological unidentified male.
Resumo:
During the last decade Mongolia’s region was characterized by a rapid increase of both severity and frequency of drought events, leading to pasture reduction. Drought monitoring and assessment plays an important role in the region’s early warning systems as a way to mitigate the negative impacts in social, economic and environmental sectors. Nowadays it is possible to access information related to the hydrologic cycle through remote sensing, which provides a continuous monitoring of variables over very large areas where the weather stations are sparse. The present thesis aimed to explore the possibility of using NDVI as a potential drought indicator by studying anomaly patterns and correlations with other two climate variables, LST and precipitation. The study covered the growing season (March to September) of a fifteen year period, between 2000 and 2014, for Bayankhongor province in southwest Mongolia. The datasets used were MODIS NDVI, LST and TRMM Precipitation, which processing and analysis was supported by QGIS software and Python programming language. Monthly anomaly correlations between NDVI-LST and NDVI-Precipitation were generated as well as temporal correlations for the growing season for known drought years (2001, 2002 and 2009). The results show that the three variables follow a seasonal pattern expected for a northern hemisphere region, with occurrence of the rainy season in the summer months. The values of both NDVI and precipitation are remarkably low while LST values are high, which is explained by the region’s climate and ecosystems. The NDVI average, generally, reached higher values with high precipitation values and low LST values. The year of 2001 was the driest year of the time-series, while 2003 was the wet year with healthier vegetation. Monthly correlations registered weak results with low significance, with exception of NDVI-LST and NDVI-Precipitation correlations for June, July and August of 2002. The temporal correlations for the growing season also revealed weak results. The overall relationship between the variables anomalies showed weak correlation results with low significance, which suggests that an accurate answer for predicting drought using the relation between NDVI, LST and Precipitation cannot be given. Additional research should take place in order to achieve more conclusive results. However the NDVI anomaly images show that NDVI is a suitable drought index for Bayankhongor province.
Resumo:
Eye tracking as an interface to operate a computer is under research for a while and new systems are still being developed nowadays that provide some encouragement to those bound to illnesses that incapacitates them to use any other form of interaction with a computer. Although using computer vision processing and a camera, these systems are usually based on head mount technology being considered a contact type system. This paper describes the implementation of a human-computer interface based on a fully non-contact eye tracking vision system in order to allow people with tetraplegia to interface with a computer. As an assistive technology, a graphical user interface with special features was developed including a virtual keyboard to allow user communication, fast access to pre-stored phrases and multimedia and even internet browsing. This system was developed with the focus on low cost, user friendly functionality and user independency and autonomy.
Resumo:
Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)
Resumo:
Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.