215 resultados para Dynamometer.
Resumo:
OBJECTIVES: To evaluate morbidity associated with the radial forearm free flap donor site and to compare functional and aesthetic outcomes of ulnar-based transposition flap (UBTF) vs split-thickness skin graft (STSG) closure of the donor site.¦DESIGN: Case-control study.¦SETTING: Tertiary care institution.¦PATIENTS: The inclusion criteria were flap size not exceeding 30 cm(2), patient availability for a single follow-up visit, and performance of surgery at least 6 months previously. Forty-four patients were included in the study and were reviewed. Twenty-two patients had UBTF closure, and 22 had STSG closure.¦MAIN OUTCOME MEASURES: Variables analyzed included wrist mobility, Michigan Hand Outcomes Questionnaire scores, pinch and grip strength (using a dynamometer), and hand sensitivity (using monofilament testing over the radial nerve distribution). In analyses of operated arms vs nonoperated arms, variables obtained only for the operated arms included Vancouver Scar Scale scores and visual analog scale scores for Aesthetics and Overall Arm Function.¦RESULTS: The mean (SD) wrist extension was significantly better in the UBTF group (56.0° [10.4°] for nonoperated arms and 62.0° [9.7°] for operated arms) than in the STSG group (59.0° [7.1°] for nonoperated arms and 58.4° [12.1°] for operated arms) (P = .02). The improvement in wrist range of motion for the UBTF group approached statistical significance (P = .07). All other variables (Michigan Hand Outcomes Questionnaire scores, pinch and grip strength, hand sensitivity, and visual analog scale scores) were significantly better for nonoperated arms vs operated arms, but no significant differences were observed between the UBTF and STSG groups.¦CONCLUSIONS: The radial forearm free flap donor site carries significant morbidity. Donor site UBTF closure was associated with improved wrist extension and represents an alternative method of closure for small donor site defects.
Resumo:
CONTEXT: A passive knee-extension test has been shown to be a reliable method of assessing hamstring tightness, but this method does not take into account the potential effect of gravity on the tested leg. OBJECTIVE: To compare an original passive knee-extension test with 2 adapted methods including gravity's effect on the lower leg. DESIGN: Repeated measures. SETTING: Laboratory. PARTICIPANTS: 20 young track and field athletes (16.6 ± 1.6 y, 177.6 ± 9.2 cm, 75.9 ± 24.8 kg). INTERVENTION: Each subject was tested in a randomized order with 3 different methods: In the original one (M1), passive knee angle was measured with a standard force of 68.7 N (7 kg) applied proximal to the lateral malleolus. The second (M2) and third (M3) methods took into account the relative lower-leg weight (measured respectively by handheld dynamometer and anthropometrical table) to individualize the force applied to assess passive knee angle. MAIN OUTCOME MEASURES: Passive knee angles measured with video-analysis software. RESULTS: No difference in mean individualized applied force was found between M2 and M3, so the authors assessed passive knee angle only with M2. The mean knee angle was different between M1 and M2 (68.8 ± 12.4 vs 73.1 ± 10.6, P < .001). Knee angles in M1 and M2 were correlated (r = .93, P < .001). CONCLUSIONS: Differences in knee angle were found between the original passive knee-extension test and a method with gravity correction. M2 is an improved version of the original method (M1) since it minimizes the effect of gravity. Therefore, we recommend using it rather than M1.
Resumo:
The purpose of this study was to evaluate a new method of measuring rolling resistance in treadmill cycling and to establish its sensitivity and reproducibility. One participant was asked to keep a bicycle in equilibrium on a treadmill without pedalling at a constant speed of 5.56 m x s(-1), which was held in place in the front by a dynamometer. For each condition, the method consisted of 11 measurements of the force required to hold the cycle at different treadmill slopes (0-10%, increment 1%). The coefficient of rolling resistance was calculated based on the forces applied to the bicycle in equilibrium. To test the sensitivity of the method, the bicycle was successively equipped with three tyre types (700 x 28, 700 x 23, 700 x 22) and inflation pressure was set at 150, 300, 600, 900, and 1100 kPa. To test the reproducibility of the method, a second experimenter repeated all measurements done with the 700 x 23 tyres. The method was sensitive enough to detect an effect of both tyre type and inflation pressure (P < 0.001: two-way ANOVA). The measurement of the coefficient of rolling resistance by two separate experimenters resulted in a small bias of 0.00029 (95% CI, -0.00011 to 0.00068). In conclusion, the new method is sensitive and reliable, as well as being simple and affordable.
Resumo:
The purpose of this study was to examine the physiological and biomechanical changes occurring in a subject after running 8,500 km in 161 days (i.e. 52.8 km daily). Three weeks before, 3 weeks after (POST) and 5 months after (POST+5) running from Paris to Beijing, energy cost of running (Cr), knee flexor and extensor isokinetic strength and biomechanical parameters (using a treadmill dynamometer) at different velocities were assessed in an experienced ultra-runner. At POST, there was a tendency toward a 'smoother' running pattern, as shown by (a) a higher stride frequency and duty factor, and a reduced aerial time without a change in contact time, (b) a lower maximal vertical force and loading rate at impact and (c) a decrease in both potential and kinetic energy changes at each step. This was associated with a detrimental effect on Cr (+6.2%) and a loss of strength at all angular velocities for both knee flexors and extensors. At POST+5, the subject returned to his original running patterns at low but not at high speeds and maximal strength remained reduced at low angular velocities (i.e. at high levels of force). It is suggested that the running pattern changes observed in the present study were a strategy adopted by the subject to reduce the deleterious effects of long distance running. However, the running pattern changes could partly be linked to the decrease in maximal strength.
Resumo:
To express the negative effects of soil compaction, some researchers use critical values for soil mechanical strength that severely impair plant growth. The aim of this study was to identify this critical compaction depth, to test the functionality of a new, portable penetrometer developed from a spring dynamometer, and compare it to an electronic penetrometer traditionally used in compaction studies of agricultural soils. Three soils with distinct texture were conventionally tilled using a disk plow, and cultivated with different plant species. The critical soil resistance defined to establish critical compaction depth was equal to 1.5 MPa. The results of the new equipment were similar to the electronic penetrometer, indicating its viability as a tool for assessing the soil physical conditions for plant growth.
Resumo:
INTRODUCTION: There is a trend towards surgical treatment of acute ruptured Achilles tendon. While classical open surgical procedures have been shown to restore good functional capacity, they are potentially associated with significant complications like wound infection and paresthesia. Modern mini-invasive surgical techniques significantly reduce these complications and are also associated with good functional results so that they can be considered as the surgical treatment of choice. Nevertheless, there is still a need for conservative alternative and recent studies report good results with conservative treatment in rigid casts or braces. PATIENTS/METHOD: We report the use of a dynamic ankle brace in the conservative treatment of Achilles tendon rupture in a prospective non-randomised study of 57 consecutive patients. Patients were evaluated at an average follow-up time of 5 years using the modified Leppilahti Ankle Score, and the first 30 patients additionally underwent a clinical examination and muscular testing with a Cybex isokinetic dynamometer at 6 and 12 months. RESULTS: We found good and excellent results in most cases. We observed five complete re-ruptures, almost exclusively in case of poor patient's compliance, two partial re-ruptures and one deep venous thrombosis complicated by pulmonary embolism. CONCLUSION: Although prospective comparison with other modern treatment options is still required, the functional outcome after early ankle mobilisation in a dynamic cast is good enough to ethically propose this method as an alternative to surgical treatment.
Resumo:
The purposes of this study were to prospectively determine changes in rotator cuff strength before and after surgical shoulder stabilization by Bristow-Latarjet procedure and to better estimate time needed for rotator cuff strength recovery. 20 patients with recurrent anterior posttraumatic shoulder dislocation underwent internal (IR) and external (ER) rotator isokinetic evaluation before and 3, 6 and 21 months after Bristow-Latarjet surgery. In a seated position with 45° of shoulder abduction in the scapular plane, both shoulders were evaluated concentrically with a Con-Trex® isokinetic dynamometer at 180°∙s - 1, 120°∙s - 1 and 60°∙s - 1. 3 months post-surgery, IR and ER strength of the operated shoulder were significantly lower than before surgery ( - 28±20% for IR, - 17±17% for ER) (P<0.05). At 6 and 21 months post-surgery, IR and ER strength were comparable to strength before surgery; strength recovery is seen at 6 months post-surgery with long-term maintenance at 21 months. Given the weakness 3 months post-surgery, return to sports (including overhead and contact sports) should be discussed, and 6 months post-surgery may be a better point for an athlete to resume practicing sports. Isokinetic rotator cuff strength evaluation appears to be relevant in helping to determine the need of continuing strength rehabilitation. Pre-surgical evaluation contributes to the relevance of later comparisons.
Resumo:
The eccentric contraction mode was proposed to be the primary stimulus for optimum angle (angle at which peak torque occurs) shift. However, the training range of motion (or muscle excursion range) could be a stimulus as important. The aim of this study was to assess the influence of the training range of motion stimulus on the hamstring optimum length. It was hypothesised that performing a single set of concentric contractions beyond optimal length (seated at 80° of hip flexion) would lead to an immediate shift of the optimum angle to longer muscle length while performing it below (supine at 0° of hip flexion) would not provide any shift. Eleven male participants were assessed on an isokinetic dynamometer. In both positions, the test consisted of 30 consecutive knee flexions at 4.19 rad · s⁻¹. The optimum angle was significantly shifted by ∼15° in the direction of longer muscle length after the contractions at 80° of hip flexion, while a non-significant shift of 3° was found at 0°. The hamstring fatigability was not influenced by the hip position. It was concluded that the training range of motion seems to be a relevant stimulus for shifting the optimum angle to longer muscle length. Moreover, fatigue appears as a mechanism partly responsible for the observed shift.
Resumo:
Työn tarkoituksena oli toteuttaa moottoriajoneuvon suorituskyvyn mittaukseen käytettävä järjestelmä. Järjestelmä koostuu sylinterin muotoisesta rullasta ja tiedonkeruujärjestelmästä. Rullaa, jonka hitausmomentti tunnetaan kiihdytetään ajoneuvon vetopyörien välityksellä ja mitatuista arvoista lasketaan teho ja vääntömomenttiarvot moottorin kierrosluvun funktiona. Tiedonkeruu tapahtuu PC-mikrotietokoneen avulla, johon on liitetty tiedonkeruukortti. PC-mikrotietokone muodostaa käyttöliittymän, jonka avulla saadut tulokset esitetään kuvaajien avulla käyttäjälle. Käyttöliittymän avulla suoritetaan myös tulosten talletus ja raportin tulostus. Teoriaosassa tarkastellaan suorituskyvyn mittaamiseen käytettyjä menetelmiä ja laitteistoja, sekä tiedonkeruujärjestelmän rakennetta ja sen valintaan vaikuttavia tekijöitä. Käytännön osassa suunnitellaan muokkainkortti, jonka avulla erilaisilta antureilta saadut signaalit voidaan sovittaa tiedonkeruukortin tuloalueelle sopiviksi. Myös käyttöliittymän toimintaa ja sen rakentamiseen käytettyjä työkaluja tarkastellaan.
Resumo:
Són habituals entre els aeromodelistes les discussions que giren al voltant de la potència dels motors d’explosió i quina hèlix va millor. La manca d’informació tècnica dels motors i de les hèlix fa que aquestes discussions de vegades tinguin una validesa molt limitada, doncs es fonamenten simplement en les sensacions i percepcions subjectives de cadascun dels pilots, sobretot quan es parla de potència. En aquest projecte s’utilitzarà un dinamòmetre inercial, consistent en un volant d’inèrcia el qual s’accelerarà fins assolir les revolucions per minut màximes. La acceleració d’aquest volant mesurat en intervals de temps regulars i conegut el moment d’inèrcia del volant ens permetrà calcular el parell motor i la potència a diferents règims de revolucions per minut. Per altra banda es pretén comparar diferents hèlix muntades en un mateix motor per poder-ne comparar la tracció a diferents revolucions per minut. La tracció es mesurarà utilitzant una cèl·lula de càrrega. Les dades d’ambdós bancs de proves seran recollits i emmagatzemats per un PC amb un software fet a mida per aquest projecte. Una vegada finalitzat cada test es mostraran les dades obtingudes, tant els numèricament com gràficament, permetent a més comparar el resultat de diferents tests, de diferents motors i de diferents hèlix.
Resumo:
STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.
Resumo:
Diesel fuel is used widely in Brazil and worldwide. On the other hand, the growing environmental awareness leads to a greater demand for renewable energy resources. Thus, this study aimed to evaluate the use of different blends of soybean (Glycine max) methyl biodiesel and diesel in an ignition compression engine with direct injection fuel. The tests were performed on an electric eddy current dynamometer, using the blends B10, B50 and B100, with 10; 50 e 100% of biodiesel, respectively, in comparison to the commercial diesel B5, with 5% of biodiesel added to the fossil diesel. The engine performance was analyzed trough the tractor power take off (PTO) for each fuel, and the best results obtained for the power and the specific fuel consumption, respectively, were: B5 (44.62 kW; 234.87 g kW-1 h-1); B10 (44.73 kW; 233.78 g kW-1 h-1); B50 (44.11 kW; 250.40 g kW-1 h-1) e B100 (43.40 kW; 263.63 g kW-1 h-1). The best performance occurred with the use of B5 and B10 fuel, without significant differences between these blends. The B100 fuel showed significant differences compared to the other fuels.
Resumo:
During vehicle deceleration due to braking there is friction between the lining surface and the brake drum or disc. In this process the kinetic energy of vehicle is turned into thermal energy that raises temperature of the components. The heating of the brake system in the course of braking is a great problem, because besides damaging the system, it may also affect the wheel and tire, which can cause accidents. In search of the best configuration that considers the true conditions of use, without passing the safety limits, models and formulations are presented with respect to the brake system, considering different braking conditions and kinds of brakes. Some modeling was analyzed using well-known methods. The flat plate model considering energy conservation was applied to a bus, using for this a computer program. The vehicle is simulated to undergo an emergency braking, considering the change of temperature on the lining-drum. The results include deceleration, braking efficiency, wheel resistance, normal reaction on the tires and the coefficient of adhesion. Some of the results were compared with dynamometer tests made by FRAS-LE and others were compared with track tests made by Mercedes-Benz. The convergence between the results and the tests is sufficient to validate the mathematical model. The computer program makes it possible to simulate the brake system performance in the vehicle. It assists the designer during the development phase and reduces track tests.
Resumo:
Falls are a major concern in the elderly population with chronic joint disease. To compare muscular function and functional mobility among older women with knee osteoarthritis with and without a history of falls, 15 elderly women with a history of falls (74.20 ± 4.46 years) and 15 without a history of falls (71.73 ± 4.73 years) were studied. Muscular function, at the angular speed of 60, 120, and 180º/s, was evaluated using the Biodex Isokinetic Dynamometer. The sit-to-stand task was performed using the Balance Master System and the Timed Up and Go test was used to determine functional mobility. After collection of these data, the history of falls was investigated. A statistically significant difference was detected in the time taken to transfer the center of gravity during the sit-to-stand test (means ± SD; non-fallers: 0.35 ± 0.16 s; fallers: 0.55 ± 0.32 s; P = 0.049, Student t-test) and in the Timed Up and Go test (medians; non-fallers: 10.08 s; fallers: 11.59 s; P = 0.038, Mann-Whitney U-test). The results indicated that elderly osteoarthritic women with a history of falls presented altered functional mobility and needed more time to transfer the center of gravity in the sit-to-stand test. It is important to implement strategies to guarantee a better functional performance of elderly patients to reduce fall risks.
Resumo:
The association of plasma interleukin-6 (IL-6) levels, muscle strength and functional capacity was investigated in a cross-sectional study of community-dwelling elderly women from Belo Horizonte, Brazil. Elderly people who present controlled chronic diseases with no negative impact on physical, psychosocial and mental functionality are considered to be community-dwelling. Psychological and social stress due to unsuccessfully aging can represent a risk for immune system disfunctions. IL-6 levels, isokinetic muscle strength of knee flexion/extension, and functional tests to determine time required to rise from a chair and gait velocity were measured in 57 participants (71.21 ± 7.38 years). Serum levels of IL-6 were measured in duplicate and were performed within one single assay (mouse monoclonal antibody against IL-6; High-Sensitivity, Quantikine®, R & D Systems, USA; intra-assay coefficient of variance = 6.9-7.4%; interassay coefficient of variance = 9.6-6.5%; sensitivity = 0.016-0.110 pg/mL; mean = 0.039 pg/mL). Muscle strength was assessed with the isokinetic dynamometer Biodex System 3 Pro®. After the Shapiro-Wilk normality test was applied, correlations were investigated using Spearman and Kruskal-Wallis tests. Post hoc analysis was performed using the Dunn test. A significant negative correlation was observed between plasma IL-6 levels (1.95 ± 1.77 pg/mL) and muscle strength for knee flexion (70.70 ± 21.14%; r = -0.265; P = 0.047) and extension (271.84 ± 67.85%; r = -0.315; P = 0.017). No significant correlation was observed between IL-6 levels and the functional tests (time to rise from a chair = 14.65 ± 2.82 s and gait velocity = 0.95 ± 0.14 m/s). These results suggest that IL-6 is associated with reduced muscle strength.