805 resultados para Dolor lumbar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to gain a competitive edge in the market, automotive manufacturers and automotive seat suppliers have identified seat ergonomics for further development to improve overall vehicle comfort. Adjustable lumbar support devices have been offered since long as comfort systems in either a 2-way or 4-way adjustable configuration, although their effect on lumbar strain is not well documented. The effect of a lumbar support on posture and muscular strain, and therefore the relationship between discomfort and comfort device parameter settings, requires clarification. The aim of this paper is to study the effect of a 4-way lumbar support on lower trunk and pelvis muscle activity, pelvic tilt and spine curvature during a car seating activity. 10 healthy subjects (5 m/f; age 19-39) performed a seating activity in a passenger vehicle with seven different static lumbar support positions. The lumbar support was tested in 3 different height positions in relation to the seatback surface centreline (high, centre, low), each having 2 depths positions (lumbar prominence). An extra depth position was added for the centre position. Posture data were collected using a VICON MX motion capture system and NORAXON DTS goniometers and inclinometer. A rigid-body model of an adjustable car seat with four-way adjustable lumbar support was constructed in UGS Siemens NX and connected to a musculoskeletal model of a seated-human, modelled in AnyBody. Wireless electromyography (EMG) was used to calibrate the musculoskeletal model and assess the relationship between (a) muscular strain and lumbar prominence (normal to seatback surface) respective to the lumbar height (alongside seatback surface), (b) hip joint moment and lumbar prominence (normal to seatback surface) respective to lumbar height (alongside seatback surface) and (c) pelvic tilt and lumbar prominence (normal to seatback surface) respective to the lumbar height (alongside seatback surface). This study was based on the assumption that the musculoskeletal human model was seated at the correct R-Point (SgRP), determined via the occupant packaging toolkit in the JACK digital human model. The effect of the interaction between the driver/car-seat has been investigated for factors resulting from the presence and adjustment of a 4-way lumbar support. The results obtained show that various seat adjustments, and driver’s lumbar supports can have complex influence on the muscle activation, joint forces and moments, all of which can affect the comfort perception of the driver. This study enables the automotive industry to optimise passenger vehicle seat development and design. It further more supports the evaluation of static postural and dynamic seat comfort in normal everyday driving tasks and can be applied for future car design to reduce investment and improve comfort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background No study relating the changes obtained in the architecture of erector spinae (ES) muscle were registered with ultrasound and different intensities of muscle contraction recorded by surface EMG (electromyography) on the ES muscle was found. The aim of this study was analyse the relationship in the response of the ES muscle during isometric moderate and light lumbar isometric extension considering architecture and functional muscle variables. Methods Cross-sectional study. 46 subjects (52% men) with a group mean age of 30.4 (±7.78). The participants developed isometric lumbar extension while performing moderate and low isometric trunk and hip extension in a sitting position with hips flexed 90 degrees and the lumbar spine in neutral position. During these measurements, electromyography recordings and ultrasound images were taken bilaterally. Bilaterally pennation angle, muscle thickness, torque and muscle activation were measured. This study was developed at the human movement analysis laboratory of the Health Science Faculty of the University of Malaga (Spain). Results Strong and moderate correlations were found at moderate and low intensities contraction between the variable of the same intensity, with correlation values ranging from 0.726 (Torque Moderate – EMG Left Moderate) to 0.923 (Angle Left Light – Angle Right Light) (p < 0.001). This correlation is observed between the variables that describe the same intensity of contraction, showing a poor correlation between variables of different intensities. Conclusion There is a strong relationship between architecture and function variables of ES muscle when describe an isometric lumbar extension at light or moderate intensity. Keywords: Ultrasonography; Surface electromyography; Thickness; Pennation angle; Erector spinae

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Lumbar Epidural Steroids Injections (ESI’s) have previously been shown to provide some degree of pain relief in sciatica. Number Needed To Treat (NNT) to achieve 50% pain relief has been estimated at 7 from the results of randomised controlled trials. Pain relief is temporary. They remain one of the most commonly provided procedures in the UK. It is unknown whether this pain relief represents good value for money. Methods 228 patients were randomised into a multi-centre Double Blind Randomised Controlled Trial. Subjects received up to 3 ESI’s or intra-spinous saline depending on response and fall off with the first injection. All other treatments were permitted. All received a review of analgesia, education and physical therapy. Quality of life was assessed using the SF36 at 6 points and compared using independent sample t-tests. Follow up was up to 1 yr. Missing data was imputed using last observation carried forward (LOCF). QALY’s (Quality of Life Years) were derived from preference based heath values (summary health utility score). SF-6D health state classification was derived from SF-36 raw score data. Standard gambles (SG) were calculated using Model 10. SG scores were calculated on trial results. LOCF was not used for this. Instead average SG were derived for a subset of patients with observations for all visits up to week 12. Incremental QALY’s were derived as the difference in the area between the SG curve for the active group and placebo group. Results SF36 domains showed a significant improvement in pain at week 3 but this was not sustained (mean 54 Active vs 61 Placebo P<0.05). Other domains did not show any significant gains compared with placebo. For derivation of SG the number in the sample in each period differed. In week 12, average SG scores for active and placebo converged. In other words, the health gain for the active group as measured by SG was achieved by the placebo group by week 12. The incremental QALY gained for a patient under the trial protocol compared with the standard care package was 0.0059350. This is equivalent to an additional 2.2 days of full health. The cost per QALY gained to the provider from a patient management strategy administering one epidural as suggested by results was £25 745.68. This result was derived assuming that the gain in QALY data calculated for patients under the trial protocol would approximate that under a patient management strategy based on the trial results (one ESI). This is above the threshold suggested by some as a cost effective treatment. Conclusions The transient benefit in pain relief afforded by ESI’s does not appear to be cost-effective. Further work is needed to develop more cost-effective conservative treatments for sciatica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Finite element (FE) model studies have made important contributions to our understanding of functional biomechanics of the lumbar spine. However, if a model is used to answer clinical and biomechanical questions over a certain population, their inherently large inter-subject variability has to be considered. Current FE model studies, however, generally account only for a single distinct spinal geometry with one set of material properties. This raises questions concerning their predictive power, their range of results and on their agreement with in vitro and in vivo values. Eight well-established FE models of the lumbar spine (L1-5) of different research centres around the globe were subjected to pure and combined loading modes and compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges, and their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with published median in vitro values. However, the ranges of predictions were larger and exceeded those reported in vitro, especially for the facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with measured in vivo values. In light of high inter-subject variability, the generalization of results of a single model to a population remains a concern. This study demonstrated that the pooled median of individual model results, similar to a probabilistic approach, can be used as an improved predictive tool in order to estimate the response of the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to its ability to represent intricate systems with material nonlinearities as well as irregular loading, boundary, geometrical and material domains, the finite element (FE) method has been recognized as an important computational tool in spinal biomechanics. Current FE models generally account for a single distinct spinal geometry with one set of material properties despite inherently large inter-subject variability. The uncertainty and high variability in tissue material properties, geometry, loading and boundary conditions has cast doubt on the reliability of their predictions and comparability with reported in vitro and in vivo values. A multicenter study was undertaken to compare the results of eight well-established models of the lumbar spine that have been developed, validated and applied for many years. Models were subjected to pure and combined loading modes and their predictions were compared to in vitro and in vivo measurements for intervertebral rotations, disc pressures and facet joint forces. Under pure moment loading, the predicted L1-5 rotations of almost all models fell within the reported in vitro ranges; their median values differed on average by only 2° for flexion-extension, 1° for lateral bending and 5° for axial rotation. Predicted median facet joint forces and disc pressures were also in good agreement with previously published median in vitro values. However, the ranges of predictions were larger and exceeded the in vitro ranges, especially for facet joint forces. For all combined loading modes, except for flexion, predicted median segmental intervertebral rotations and disc pressures were in good agreement with in vivo values. The simulations yielded median facet joint forces of 0 N in flexion, 38 N in extension, 14 N in lateral bending and 60 N in axial rotation that could not be validated due to the paucity of in vivo facet joint forces. In light of high inter-subject variability, one must be cautious when generalizing predictions obtained from one deterministic model. This study demonstrates however that the predictive power increases when FE models are combined together. The median of individual numerical results can hence be used as an improved tool in order to estimate the response of the lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rowers have and accrue greater lumbar spine bone mineral density (BMD) associated with mechanical loading produced during rowing. The aim of this study was to estimate the mechanical loading generated at the lumbar spine (LS) that is apparently providing an osteogenic benefit. The cohort comprised 14 female rowers (average age: 19.7yrs; height: 170.9 cm, weight: 59.5 kg) and 14 female matched controls (average age: 20.9 m yrs; height: 167.5 cm; weight: 58.1 kg). BMD was assessed using the Hologic QDR 2000+ bone densitometer, indicating higher lumbar spine BMD in the rowers compared to the control subjects (1,069 +/- 0.1 vs. 1,027 +/- 0.1 g/cm2). No significant difference existed for BMD at any other site. All rowers performed a six-minute simulated race on a Concept II rowing ergometer. Mechanical loading generated at the lumbar spine during this task was assessed using a two-dimensional model of the spine, enabling the calculation of the compressive and shear forces at L4/L5. The shear force was the joint reaction force perpendicular to the spine at the L4/L5 joint. Peak compressive and shear force at the lumbar spine of the rowers were 2,694 +/- 609 (N) and 660 +/- 117 (N), respectively. Peak compressive force at the LS relative to body weight was 4.6 times body weight. The literature would suggest that forces of this magnitude, generated at the LS during maximal rowing, may be contributing to the site specific higher LS BMD found in the rowers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a new method for quantifying intersegmental motion of the spine in an instrumented motion segment L4–L5 model using ultrasound image post-processing combined with an electromagnetic device. A prospective test–retest design was employed, combined with an evaluation of stability and within- and between-day intra-tester reliability during forward bending by 15 healthy male patients. The accuracy of the measurement system using the model was calculated to be ± 0.9° (standard deviation = 0.43) over a 40° range and ± 0.4 cm (standard deviation = 0.28) over 1.5 cm. The mean composite range of forward bending was 15.5 ± 2.04° during a single trial (standard error of the mean = 0.54, coefficient of variation = 4.18). Reliability (intra-class correlation coefficient = 2.1) was found to be excellent for both within-day measures (0.995–0.999) and between-day measures (0.996–0.999). Further work is necessary to explore the use of this approach in the evaluation of biomechanics, clinical assessments and interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo Establecer una posible relación entre la fuerza (Jamar), el dolor (EVA) y la capacidad funcional referida por el paciente (DASH) determinando en qué grado influyen unas en otras. Estudio observacional transversal analítico. Participantes Muestra de 72 pacientes que presentaban una artrosis trapecio metacarpiana grado 2-3 de Eaton. Los pacientes fueron reclutados cuando acudían a la Unidad de Cirugía de mano. Método Se realizaron mediciones de fuerza de agarre, pinza, valoración del dolor y funcionalidad, y se establecieron las correlaciones entre cada una de ellas. Resultados El modelo más significativo para la función (R2 =0.83) incluye la variable dolor y la fuerza. Pero es la fuerza punta contra punta la que presenta una mayor correlación con el cuestionario DASH (B-estandarizado: –57). Respecto al dolor, influye en todas las mediciones de fuerza realizadas con el dinamómetro, siendo también la fuerza de la pinza punta contra punta la que presenta una mayor correlación. Conclusiones Los hallazgos corroboran que existe una correlación significativa entre la función referida por el paciente y variables que podemos medir en consulta, como la fuerza del puño y la pinza. Pero también esta correlación es significativa entre las variables función y dolor entre sí, pero es la pinza punta contra punta la que presenta una mayor asociación con el cuestionario DASH. Abstract in English Objective To assess the relationship between muscle strength (Jama), and pain (VAS) levels with hand function (DASH) in patients with trapeziometarcapal osteoarthritis. Cross-sectional study. Participants Sample of 72 patients with osteoarthritis stage 2-3 (Eaton) and trapeziometacarpal osteoarthritis. Patients were recruited when they came to the Hand Surgery Unit. Method Grip strength, pinch, pain and hand function were measured, and correlation and regression coefficients between them were obtained. Results For function, the most significant model (R2 = 0.83) included pain and strength. But it is tip to tip pinch force which has a stronger relationship with DASH (Standardized B: –57) questionnaire. Pain also influenced strength measured with the dynamometer but it was tip to tip pinch force that was the most affected. Conclusions Findings confirm that there is a significant correlation between function referred by the patient and variables that can be measured in the clinic such as grip strength and pinch. The correlation between pain intensity and function was also significant, but tip to tip pinch strength had the greatest impact on the function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design Cross-sectional study. Objectives To compare erector spinae (ES) muscle fatigue between chronic non-specific lower back pain (CNLBP) sufferers and healthy subjects from a biomechanical perspective during fatiguing isometric lumbar extensions. Background Paraspinal muscle maximal contraction and fatigue are used as a functional predictor for disabilities. The simplest method to determine muscle fatigue is by evaluating the evolution during specific contractions, such as isometric contractions. There are no studies that evaluate the evolution of the ES muscle during fatiguing isometric lumbar extensions and analyse functional and architectural variables. Methods In a pre-calibrated system, participants performed a maximal isometric extension of the lumbar spine for 5 and 30 seconds. Functional variables (torque and muscle activation) and architecture (pennation angle and muscle thickness) were measured using a load cell, surface electromyography and ultrasound, respectively. The results were normalised and a reliability study of the ultrasound measurement was made. Results: The ultrasound measurements were highly reliable, with Cronbach’s alpha values ranging from 0.951 0.981. All measured variables shown significant differences before and after fatiguing isometric lumbar extension. Conclusion During a lumbar isometric extension test, architecture and functional variables of the ES muscle could be analised using ultrasound, surface EMG and load cell. In adition, during an endurance test, ES muscle suffers an acute effect on architectural and functional variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To analyze the ability to discriminate between healthy individuals and individuals with chronic nonspecific low back pain (CNLBP) by measuring the relation between patient-reported outcomes and objective clinical outcome measures of the erector spinae (ES) muscles using an ultrasound during maximal isometric lumbar extension. Design Cross-sectional study with screening and diagnostic tests with no blinded comparison. Setting University laboratory. Participants Healthy individuals (n=33) and individuals with CNLBP (n=33). Interventions Each subject performed an isometric lumbar extension. With the variables measured, a discriminate analysis was performed using a value ≥6 in the Roland and Morris disability questionnaire (RMDQ) as the grouping variable. Then, a logistic regression with the functional and architectural variables was performed. A new index was obtained from each subject value input in the discriminate multivariate analysis. Main Outcome Measures Morphologic muscle variables of the ES muscle were measured through ultrasound images. The reliability of the measures was calculated through intraclass correlation coefficients (ICCs). The relation between patient-reported outcomes and objective clinical outcome measures was analyzed using a discriminate function from standardized values of the variables and an analysis of the reliability of the ultrasound measurement. Results The reliability tests show an ICC value >.95 for morphologic and functional variables. The independent variables included in the analysis explained 42% (P=.003) of the dependent variable variance. Conclusions The relation between objective variables (electromyography, thickness, pennation angle) and a subjective variable (RMDQ ≥6) and the capacity of this relation to identify CNLBP within a group of healthy subjects is moderate. These results should be considered by clinicians when treating this type of patient in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design This was a randomised controlled trial in patients with degenerative disc disease (DDD) who underwent instrumented posterolateral lumbar fusion (PLF) surgery. Objective The aim of this study was to assess the efficacy of the bone grafting substitute, silicate-substituted calcium phosphate (SiCaP) compared with bone morphogenetic protein (rhBMP-2) and to evaluate clinical outcomes over a period of two years. Methods Patients undergoing PLF surgery for DDD at a single centre were recruited and randomised to one of two groups; SiCaP (n=9) or rhBMP-2 (n=10). One patient withdrew prior to randomisation and another from the rhBMP-2 group after randomisation. The radiological and clinical outcomes were examined and compared. Fusion was assessed at 12 months with computed tomography (CT) and plain radiographs. Clinical outcomes were evaluated by recording measures of pain, quality of life, disability and neurological status from six weeks to two years postoperatively. Results In the SiCaP and rhBMP-2 groups, fusion was observed in 9/9 and 8/9 patients respectively. Pain and disability scores were reduced and quality of life increased in both groups. Leg pain, disability and satisfaction scores were similar between the groups at each postoperative time point, however, back pain was less at six weeks and quality of life was higher at six months in the SiCaP group than the rhBMP-2 group. Conclusions SiCaP and rhBMP-2 were comparable in terms of achieving successful bone growth and fusion. Both groups similarly alleviated pain and improved quality of life, neurological, satisfaction and return to work outcomes following PLF surgery.