312 resultados para Digestor Anaeróbio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the validity of critical force test from maximal lactate steady state (MLSS) during resistance test using straight bench press. Five healthy male volunteers aged (22.6 ± 2.88 years), weight (76.3 ± 11.49 kg) e height (182.6 ± 7.54cm), trained in resistance exercise, and performed four diferent test to determine: one maximal effort (1RM), critical force using the critical power model (force vs 1/time limit - 20, 25 and 30% 1RM). The CF was the linear coefficient and the anaerobic impulse capacity (CIA) was the angular. MLSS was determined using loads of 80, 90, 100 and 110% of critical force. Blood lactate samples were abtained at each 300sec between each stage of total 1200sec. Maximal 30s test (M30) was accomplished with load of 25% of body weight in SBP. The results showed that the 1 RM was 79.4 Kgf (± 16.98), CF 10.1N (± 2.25), CIA 1756.82 N.s (± 546.96) and the R² 0.984 (± 0,02). The MLSS occurs at 100% CF load. The lactate concentration at the MLSS was 2.2 mmol/L (± 0.77). Significant correlation was observed between MLSS and CF on SBP (r = 0.88 p = 0.05). In M30 the minimum, mean and peak power were (25.0 ± 4.9, 28.0 ± 4.9, and 30.0 ± 4.6 kgf.rps, respectively). The fatigue index was 18.0% (± 6,8). The M30 was significantly correlated with Ppeak and Pmean (r = 0.98 for both, p = 0.003). The CF means has been validated to predict the resistance training and the CIA show to be a representative anaerobic parameter in straight bench press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water and soil pollution caused by the waste from the swine production causes severe environmental impacts in producing areas. An efficient alternative to reduce these impacts can be the use of high-rate anaerobic reactors. In this work, it was evaluated the effect of the swine wastewater with total suspended solids concentrations around 6.000 mg.L-1 in the anaerobic baffled reactor with three compartments. The volume of the first compartment was 210 L and of the second and third ones of 160 L. The anaerobic baffled reactor was submitted at hydraulic detention times of 56, 28 and 18 hours and to organic load rates of 5.0 to 10.1 g total COD (L.d)(-1). The highest total COD removals, of 42 to 68%, and volumetric methane productions, of 0.261 to 0.454 L CH4 (L reactor d)(-1), occurred in the second compartment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo de la presente investigación consiste en estudiar el aprovechamiento solar para el calentamiento de los fangos en los digestores anaerobios mediante agua caliente circulando en el interior de un serpentín que rodea la superficie de dicho digestor, como alternativa a los métodos convencionales del calentamiento de fangos como la resistencia eléctrica o el intercambiador de calor mediante la energía obtenida por el gas metano producido en la digestión anaerobia. Se utilizaron 3 digestores, dos de los cuales se calentaron con agua caliente en el interior de un serpentín procedente de un sistema de calentamiento de agua con colectores solares planos (uno aislado mediante una capa de fibra de vidrio y poliuretano y otro sin aislar).El tercer digestor no tenía calentamiento exterior con el objetivo de observar su comportamiento y comparar su evolución con el resto de los digestores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Debido al gran interés existente en el ahorro y recuperación de energía, y en el deseo de obtener productos que permitan usos beneficiosos del fango procedente de la depuración del agua residual, la digestión anaerobia es el proceso de estabilización de uso más extendido. El tiempo de retención de sólidos es un factor clave en el proceso de digestión anaerobia. En base al tiempo de retención de sólidos, se dimensiona el volumen de los digestores anaerobios para así obtener la reducción de materia orgánica deseada, con la correspondiente producción de biogás. La geometría del digestor y su sistema de agitación deben ser adecuados para alcanzar el tiempo de retención de sólidos de diseño. Los primeros trabajos sobre la agitación de los digestores realizaban únicamente experimentos con trazadores y otros métodos de medición. En otros casos, la mezcla era evaluada mediante la producción de biogás. Estas técnicas tenían el gran hándicap de no conocer lo que sucedía realmente dentro del digestor y sólo daban una idea aproximada de su funcionamiento. Mediante aplicación de la mecánica de fluidos computacional (CFD) es posible conocer con detalle las características del fluido objeto de estudio y, por lo tanto, simular perfectamente el movimiento del fango de un digestor anaerobio. En esta tesis se han simulado mediante CFD diferentes digestores a escala real (unos 2000 m3 de volumen) agitados con bomba/s de recirculación para alcanzar los siguientes objetivos: establecer la influencia de la relación entre el diámetro y la altura, de la pendiente de la solera, del número de bombas y del caudal de recirculación en dichos digestores, definir el campo de velocidades en la masa de fango y realizar un análisis energético y económico. Así, es posible conocer mejor cómo funciona el sistema de agitación de un digestor anaerobio a escala real equipado con bomba/s de recirculación. Los resultados obtenidos muestran que una relación diámetro/altura del digestor por encima de 1 empeora la agitación del mismo y que la pendiente en la solera del digestor favorece que la masa de fango esté mejor mezclada, siendo más determinante la esbeltez del tanque que la pendiente de su solera. No obstante, también es necesario elegir adecuadamente los parámetros de diseño del sistema de agitación, en este caso el caudal de recirculación de fango, para obtener una agitación completa sin apenas zonas muertas. En el caso de un digestor con una geometría inadecuada es posible mejorar su agitación aumentando el número de bombas de recirculación y el caudal de las mismas, pero no se llegará a alcanzar una agitación total de la masa de fango debido a su mal diseño original. Anaerobic digestion is the process for waste water treatment sludge stabilization of more widespread use due to the huge interest in saving and recovering energy and the wish to obtain products that allow beneficial uses for the sludge. The solids retention time is a key factor in the anaerobic digestion. Based on the solids retention time, volume anaerobic digester is sized to obtain the desired reduction in organic matter, with the corresponding production of biogas. The geometry of the digester and the stirring system should be adequate to achieve the design solid retention time. Early works on digesters stirring just performed tracer experiments and other measurement methods. In other cases, mixing was evaluated by biogas production. These techniques had the great handicap of not knowing what really happened inside the digester and they only gave a rough idea of its operation. By application of computational fluid dynamics (CFD), it is possible to know in detail the characteristics of the fluid under study and, therefore, simulate perfectly the sludge movement of an anaerobic digester. Different full-scale digesters (about 2000 m3 of volume) agitated with pump/s recirculation have been simulated by CFD in this thesis to achieve the following objectives: to establish the influence of the relationship between the diameter and height, the slope of the bottom, the number of pumps and the recirculation flow in such digesters, to define the velocity field in the mass of sludge and carry out an energy and economic analysis. Thus, it is possible to understand better how the agitation system of a full-scale anaerobic digester equipped with pump/s recirculation works. The results achieved show that a diameter/height ratio of the digester above 1 worsens its stirring and that the slope of the digester bottom favors that the mass of sludge is better mixed, being more decisive the tank slenderness than the slope of its bottom. However, it is also necessary to select properly the design parameters of the agitation system, in this case the sludge recirculation flow rate, for a complete agitation with little dead zones. In the case of a digester with inadequate geometry, its agitation can be improved by increasing the number of recirculation pumps and flow of them, but it will not reach a full agitation of the mass of sludge because of the poor original design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A opção por sistemas biológicos prevalece para o tratamento do esgoto sanitário. Nas décadas recentes, sistemas que possuem regiões e/ou zonas anaeróbia, anóxica e aeróbia têm-se mostrado como alternativas atraentes para remoção simultânea de matéria orgânica, nitrogênio e fósforo. No entanto, os aspectos operacionais ainda merecem ser objeto de estudo para alcançar desempenho otimizado. Nesse cenário, com intuito de comparar alternativas para a operação das unidades de tratamento de esgoto, o presente trabalho propôs-se a estudar estratégias operacionais associadas ao monitoramento, em tempo real, sem adição de fonte externa de carbono, para um reator aerado não compartimentado com crescimento suspenso e fluxo contínuo precedido de reator anaeróbio. O sistema experimental, em escala de bancada, era constituído de um reator anaeróbio, com volume útil de 43,54 L, e reator aerado, com volume útil de 68,07 L; sendo que este era formado por sete setores, em série, sem separação física. O estudo foi dividido em duas etapas: I - estudo da variação dos volumes da região aerada e da não aerada; II - estudo da aeração intermitente com ciclo de aeração/agitação pré-fixado e controlado em tempo real por sistema informatizado. Em todas as Etapas do estudo ocorreu elevada remoção de DBO e conversão de NTK para nitrato, contudo não se conseguiu obter desnitrificação em nível desejado. O uso de reatores com setores sequenciais sem divisão física (Etapa I) dificultou a obtenção de regiões distintas predominantemente anóxica e aeróbia, comprometendo a remoção de nitrogênio (principalmente a desnitrificação). A maior eficiência média de remoção de nitrogênio alcançada no reator aerado foi de 35,6% (Etapa II), quando o reator era operado com aeração intermitente sendo o ciclo de aeração/agitação controlado em tempo real. A estratégia de operação com aeração intermitente, estudada na Etapa II, favoreceu a remoção de nitrogênio. A aeração intermitente demonstrou ser uma opção promissora comparada à aeração contínua em setores específicos do reator. O controle automatizado e informatizado em tempo real dos ciclos de aeração/agitação pode ser aplicado no aperfeiçoamento da operação dos sistemas de tratamento de esgoto sanitário.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo desse projeto de pesquisa foi avaliar a redução do sulfato e promover a remoção do sulfeto, por via de conversão a enxofre elementar, em reatores combinados anaeróbio/microaerado. Para tanto foram utilizados três sistemas com objetivos específicos. A primeira configuração foi um reator anaeróbio de leito fixo e ordenado integrado a um reator microaerado com membrana externa (ABFSB-RME) com o qual se avaliou a influência do tempo de detenção hidráulica (TDH) e da presença de biomassa aderida na remoção do sulfeto. A segunda configuração avaliada foi um reator UASB com um reator microaerado de membrana helicoidal externa (UASB-RMHE), com o qual se avaliou a formação de biofilme no interior da membrana e a alteração do pH para a remoção do sulfeto em sua fase gasosa. A terceira configuração foi um reator anaeróbio de leito fixo e ordenado combinado a um reator microaerado com membrana helicoidal e submersa ao meio liquido (ABFSB-RMHS) com a finalidade de avaliar a remoção do sulfeto com aplicação de fluxo de ar no interior da membrana e avaliar a influência do TDH na eficiência de conversão do sulfeto. Os resultados indicam que a troca periódica das membranas tem influência na eficiência da conversão do sulfeto para o sistema ABFSB-RME. O sistema UASB-RMHE apresentou dados de remoção de sulfeto estáveis durante 35 dias, com remoção de até 90%, porém a retro lavagem da membrana é essencial para o aumento da vida útil do sistema A alteração do pH provocou a deslocamento de equilíbrio do sulfeto, e apresentou remoção do sulfeto no biogás de 98% para pH 7,5 e 50% para pH 7,0. O sistema ABFSB-RMHS propiciou remoção estável de sulfeto e a formação em camadas de enxofre elementar ao redor da membrana que se rompiam permitindo, assim, a sedimentação e recuperação do material sólido. Os resultados obtidos na pesquisa mostraram que os sistemas apresentam viabilidade e potencial no tratamento de águas ricas em compostos de enxofre e para a recuperação de enxofre elementar, além de apresentar versatilidade por meio de variáveis operacionais, com as quais se podem obter o controle e aperfeiçoamento do sistema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As águas residuárias provenientes da indústria do charque são conhecidas por apresentarem elevado teor de cloreto de sódio, aliado a grandes concentrações de matéria orgânica proveniente do sangue liberado ao longo do processo industrial. Esse tipo de água residuária apresenta potencial para degradação biológica, contudo, o cloreto de sódio, em concentração elevada, pode inibir a atividade dos microrganismos e, em alguns casos, levar sistemas biológicos à falência. No presente trabalho, foi avaliada a viabilidade de degradação anaeróbia de efluente sintético de Charqueada contendo elevado teor de cloreto de sódio, em reator anaeróbio tipo UASB (Upflow Anaerobic Sludge Blanket), em escala de laboratório. Foram utilizados 4 reatores, alimentados com água residuária sintética com características similares à água residuária de Charqueada. O reator 1 foi utilizado como controle, o reator 2 recebeu NaCl e os demais (3 e 4) foram operados na presença de NaCl acrescidos de: betaína e potássio com cálcio, respectivamente. Os compostos citados são conhecidos como antagonizantes, por possuirem capacidade de minimizar o efeito inibitório do sódio sobre o processo de digestão anaeróbia. Os reatores foram inoculados com lodo de reator UASB e submetidos à concentração de 5000 mg/L de matéria orgânica, como DQO. A carga orgânica aplicada foi de 5 Kg/m3.d e os reatores não suportaram tal carga. Reiniciou-se a operação com aumento progressivo da DQO de 500 a 2000 mg/L resultando em cargas orgânicas de 0,5 a 2,0 Kg/m3.d, respectivamente. Após estabilização dos reatores, iniciou-se a fase de introdução de cloreto de sódio (1.500 a 13.500 mg/L) e antagonizantes com aumento progressivo a cada fase. Na presença ou ausência de antagonizantes, os reatores 2, 3 e 4 não tiveram o desempenho alterado até a concentração de NaCl de 6000 mg/L. Na presença de 9000 mg/L de NaCl, a betaína se mostrou pouco efetiva como soluto compatível no reator 3 e os antagonizantes do reator 4, potássio e cálcio, apresentaram efeitos estimulatórios. As morfologias encontradas ao longo do experimento foram cocos, víbrios, bacilos, sarcinas, além de morfologias semelhantes a Methanosarcina sp. e Methanosaeta sp. O aumento da concentração de cloreto de sódio provocou a redição da população de Arqueas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho apresenta as avaliações de desempenho, das demandas operacionais e dos fatores intervenientes no aumento da escala da unidade piloto do Reator anaeróbio Horizontal de Leito Fixo (RAHLF) no tratamento de esgoto sanitário após passagem por peneira com malha de 1 mm, durante dois anos de operação. O reator dispunha de volume total de 237,5 1, construídos com tubos comerciais de PVC de 14,5 cm de diâmetro (D), dispostos em cinco módulos horizontais em série de 2,88 m, perfazendo um comprimento total de (L) de 14,4 m e relação de total de L/D de 100. O suporte de imobilização de biomassa, espuma de poliuretano em matrizes cúbicas de 1 cm de aresta, mostrou-se adequado ao desenvolvimento do biofilme. Em partida, sem inoculação prévia, ocorreu a sua consolidação a partir de 70 dias, com predominância de morfologia semelhante a Methanosaeta sp. em relação a da Methanosarcina. Em torno de 90 dias com afluente de 350 mg/l de DQO, observe-se a melhor qualidade do efluente, com valor de 100 mg/l de DQO. Em longa operação ocorreu queda de rendimento e menor reprodutibilidade das previsões do projeto, atribuída aos constantes entupimentos e ineficácia das operações de limpeza, com o comprometimento de volume reacional verificados por estudos de hidrodinâmica. Da investigação das origens dos equipamentos observou-se tratar mais de um efeito local e qualitativamente relacionado à biomassa retida que propriamente quantitativo e extensivo ao longo de todo reator, com produção continuada de polímeros extracelulares, promovendo um efeito sinérgico com os predominantes organismos filamentosos e com os sólidos particulados retidos no leito. Diante das potencialidades desta configuração de reator apontam-se alternativas de mitigação dos entupimentos e o direcionamento dos estudos necessários para novo aumento de escala para o tratamento de esgoto sanitário.