954 resultados para Determination of aluminium in water
Resumo:
A study on the presence of herbicides, namely simazine, metribuzin, metolachlor, trifluralin, atrazine and two metabolites, deisopropylatrazine (DIA) and deethylatrazine (DEA), was performed in ground and surface waters from Primavera do Leste region, Mato Grosso state (Middle West of Brazil). The analytical procedure was based on solid-phase extraction (SPE) with Sep-Pak C18 disposable cartridges and ethyl acetate for elution solvent. Residue levels were determined by gas chromatography with nitrogen-phosphorus detection. For most of the pesticides average recoveries at different fortification levels were >with relative standard deviation < The recoveries of DIA and trifluralin in water were 25% and 56%, respectively, which were attributed to the incomplete retention of DIA and strong retention on the sorbing material and high volatility of trifluralin. Detection limits ranged from 0.023 to 0.088 μg L-1. This method was applied for the analysis of 5 superficial water samples and 28 groundwater samples, in places used for human consumption without previous treatment, collected in Primavera do Leste, Mato Grosso, Brazil. Results indicated that the highest level of contamination in a water sample was 1.732 μg L-1 for metolachlor, while metribuzin was the most frequently detected herbicide with maximum concentration of 0.351 μg L-1. ©2006 Sociedade Brasileira de Química.
Resumo:
In the present study, a simple, rapid and sensitive method was developed for the determination of mercury concentrations in the muscle tissue of fish from the Brazilian Amazon using graphite furnace atomic absorption spectrometry (GFAAS) following acid mineralization of the samples in an ultrasonic cold water bath. Using copper nitrate as a chemical modifier in solution and sodium tungstate as permanent modifier, we were able to attain thermal stabilization of the mercury up to the atomisation temperature of 1600 °C in the GFAAS assay. The calculated limits of detection (LOD) and quantification (LOQ) were 0.014 and 0.047 mg kg-1, respectively. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
The chloropropyl silica gel was modified with octa(3-aminopropyl) octasilsesquioxane and characterized by Fourier transform infrared (FTIR) spectroscopy, nuclear magnetic resonance (NMR), spectroscopies, and surface and area porosity. The specific sorption capacity of metallic ions (Cu2+ and Ni2+) increases in the following solvent order: water < ethanol 42% < ethanol < ketone. The high values of the constant (K) in the order of 103 L mol-1 suggested the high adsorbent capacity of the modified silica (SGAPC) for Cu2+ and Ni2+. SGAPC was applied to a separation column and shows recoveries of around 100% of copper in samples of sugar cane spirit, vodka, ginger brandy, and ethanol fuel. © 2013 Devaney Ribeiro Do Carmo et al.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of pantoprazole (CAS 102625-70-7) in human plasma using lansoprazole (CAS 103577-45-3) as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid/liquid extraction using diethyl-ether/dichloromethane (70:30; v/v) and chromatographed on a C-8 analytical column. The mobile phase consisted of acetonitrile/water/methanol (57:25:18; v/v/v) + 10 mmol/l acetic acid + 20 mmol/l ammonium acetate. The method has a chromatographic total run time of 4.5 min and was linear within the range 5.0-5,000 ng/mL. Detection was performed on a triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precisions calculated from quality control (QC) samples were 4.2% and 3.2%, respectively. The accuracies as determined from QC samples were -5.0% (intra-run) and 2.0% (inter-run). The method herein described was employed in a bioequivalence study of two tablet formulations of pantoprazole.
Resumo:
Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five-electron transfer vs. Ag vertical bar AgCl, KCl 3 M reference electrode. Very well-resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L-1 at -1.43, -1.57, -1.73, -1.88, and -2.05 V. The proposed DPV method has a good linear response in the 3.00 - 10.0 mu mol L-1 range, with a limit of detection (L.O.D) of 0.756 mu mol L-1 and 0.831 mu mol L-1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 mu mol L-1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.024207jes] All rights reserved.
Resumo:
Indomethacin (IND) is the drug of choice for the closure of a patent ductus arteriosus (PDA) in neonates. This paper describes a simple, sensitive, accurate and precise microscale HPLC method suitable for the analysis of IND in plasma of premature neonates. Samples were prepared by plasma protein precipitation with acetonitrile containing the methyl ester of IND as the internal standard (IS). Chromatography was performed on a Hypersil C-18 column. The mobile phase of methanol, water and orthophosphoric acid (70:29.5:0.5, v/v, respectively), was delivered at 1.5 mL/min and monitored at 270 nm. IND and the IS were eluted at 2.9 and 4.3 min, respectively. Calibrations were linear (r > 0.999) from 25 to 2500 mu g/L. The inter- and intra-day assay imprecision was less than 4.3% at 400-2000 mu g/L, and less than 22.1% at 35 mu g/L. Inaccuracy ranged from -6.0% to +1.0% from 35 to 2000 mu g/L. The absolute recovery of IND over this range was 93.0-113.3%. The IS was stable for at least 36 h when added to plasma at ambient temperature. This method is suitable for pharmacokinetic studies of IND and has potential for monitoring therapy in infants with PDA when a target therapeutic range for IND has been validated. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Background Sucralose has gained popularity as a low calorie artificial sweetener worldwide. Due to its high stability and persistence, sucralose has shown widespread occurrence in environmental waters, at concentrations that could reach up to several μg/L. Previous studies have used time consuming sample preparation methods (offline solid phase extraction/derivatization) or methods with rather high detection limits (direct injection) for sucralose analysis. This study described a faster and sensitive analytical method for the determination of sucralose in environmental samples. Results An online SPE-LC–MS/MS method was developed, being capable to quantify sucralose in 12 minutes using only 10 mL of sample, with method detection limits (MDLs) of 4.5 ng/L, 8.5 ng/L and 45 ng/L for deionized water, drinking and reclaimed waters (1:10 diluted with deionized water), respectively. Sucralose was detected in 82% of the reclaimed water samples at concentrations reaching up to 18 μg/L. The monthly average for a period of one year was 9.1 ± 2.9 μg/L. The calculated mass loads per capita of sucralose discharged through WWTP effluents based on the concentrations detected in wastewaters in the U. S. is 5.0 mg/day/person. As expected, the concentrations observed in drinking water were much lower but still relevant reaching as high as 465 ng/L. In order to evaluate the stability of sucralose, photodegradation experiments were performed in natural waters. Significant photodegradation of sucralose was observed only in freshwater at 254 nm. Minimal degradation (<20%) was observed for all matrices under more natural conditions (350 nm or solar simulator). The only photolysis product of sucralose identified by high resolution mass spectrometry was a de-chlorinated molecule at m/z 362.0535, with molecular formula C12H20Cl2O8. Conclusions Online SPE LC-APCI/MS/MS developed in the study was applied to more than 100 environmental samples. Sucralose was frequently detected (>80%) indicating that the conventional treatment process employed in the sewage treatment plants is not efficient for its removal. Detection of sucralose in drinking waters suggests potential contamination of surface and ground waters sources with anthropogenic wastewater streams. Its high resistance to photodegradation, minimal sorption and high solubility indicate that sucralose could be a good tracer of anthropogenic wastewater intrusion into the environment.
Resumo:
A method was developed for sampling and analysis of gases contained in interstitial water. Interstitial water was separated from sediments with a filter press-type sediment squeezer and transferred to a specially designed sampler-stripper. Gases contained in the interstitial water were stripped from solution and analyzed by gas chromatography. Argon, N2, and CH4 have been measured in sediments. The technique can be used to measure total CO2 and H2S with minor modifications.
Resumo:
A method for determination of lactose in food samples by Osteryoung square wave voltammetry (OSWV) was developed. It was based on the nucleophilic addition reaction between lactose and aqua ammonia. The carbonyl group of lactose can be changed into imido group, and this increases the electrochemical activity in reduction and the sensitivity. The optimal condition for the nucleophilic addition reaction was investigated and it was found that in NH4Cl–NH3 buffer of pH 10.1, the linear range between the peak current and the concentration of lactose was 0.6–8.4 mg L−1, and the detection limits was 0.44 mg L−1. The proposed method was applied to the determination of lactose in food samples and satisfactory results were obtained.