992 resultados para Delivers digital platform


Relevância:

30.00% 30.00%

Publicador:

Resumo:

http://digitalcommons.colby.edu/atlasofmaine2005/1015/thumbnail.jpg

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are over 6000 natural resource drilling platforms in the Gulf of Mexico, all of which will become obsolete once their deposits are extracted. This study examined one of the possible alternate uses for these platforms, wind power potential. Using ArcGIS the number of platforms was reduced by weighting their distance from National Data Buoy Center wind speed collection points and water depth. Calculations were done to assess the optimal sites remaining, as well as provide an estimate of the energy potential for each site. Data for this project was obtained from the Minerals Management Service (MMS), United States Geological Service (USGS), and National Data Buoy Center (NDBC). A major limitation of this project was a lack of NDBC wind speed buoys, creating large data gaps and excluding many oil rigs that have otherwise high energy potential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

http://digitalcommons.winthrop.edu/dacusfocus/1034/thumbnail.jpg

Relevância:

30.00% 30.00%

Publicador:

Resumo:

http://digitalcommons.winthrop.edu/dacusfocus/1032/thumbnail.jpg

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays due to the security vulnerability of distributed systems, it is needed mechanisms to guarantee the security requirements of distributed objects communications. Middleware Platforms component integration platforms provide security functions that typically offer services for auditing, for guarantee messages protection, authentication, and access control. In order to support these functions, middleware platforms use digital certificates that are provided and managed by external entities. However, most middleware platforms do not define requirements to get, to maintain, to validate and to delegate digital certificates. In addition, most digital certification systems use X.509 certificates that are complex and have a lot of attributes. In order to address these problems, this work proposes a digital certification generic service for middleware platforms. This service provides flexibility via the joint use of public key certificates, to implement the authentication function, and attributes certificates to the authorization function. It also supports delegation. Certificate based access control is transparent for objects. The proposed service defines the digital certificate format, the store and retrieval system, certificate validation and support for delegation. In order to validate the proposed architecture, this work presents the implementation of the digital certification service for the CORBA middleware platform and a case study that illustrates the service functionalities

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Televisão Digital: Informação e Conhecimento - FAAC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Comunicação - FAAC