986 resultados para DC discharges


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that the application of a modest dc electrical field, about 4 V/cm, can significantly reduce grain growth in yttria-stabilized polycrystalline zirconia. These measurements were made by annealing samples, for 10 h at 1300°C, with and without an electrical field. The finding adds a new dimension to the role of applied electrical fields in sintering and superplasticity, phenomena that are critical to the net-shape processing of ceramics. Grain-growth retardation will considerably enhance the rates of sintering and superplasticity, leading to significant energy efficiencies in the processing of ceramics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four types of microstrip coupled line DC blocks are analysed and expressions for the theoretically possible maximum bandwidth for a given ripple are derived. A procedure for designing a DC block to meet a given set of ripple and bandwidth specifications is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sticky florestina (Florestina tripteris DC.) is an annual exotic weed that has become naturalised near the townships of Tambo and Barcaldine in central western Queensland, Australia. Three experiments conducted near Barcaldine identified foliar herbicides effective in killing sticky florestina plants and in providing residual activity to reduce recruitment from the soil seed bank. An initial chemical screening experiment evaluated the efficacy of 28 herbicide treatments. The most promising herbicides were then further evaluated in two response-rate experiments. Overall, 2,4-D/picloram, aminopyralid/fluroxypyr, clopyralid, metsulfuron-methyl and triclopyr/picloram proved to be the most effective selective herbicides. Two of these, metsulfuron-methyl at 18 g active ingredient (a.i) ha–1 and 2,4-D + picloram at 900 g a.i. ha–1 + 225 g a.i. ha–1 have now been included in a minor use permit (PER11920) with the Australian Pesticides and Veterinary Medicines Authority (APVMA) for the control of sticky florestina in pasture, stock route, roadside and non-crop situations using both spot and boom-spray applications (APVMA 2010). The permit also allows the use of 2,4-D amine for the control of seedlings only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discharge pulse rates at different magnitude levels are often used as criteria for monitoring the partial-discharge aging of insulation systems. Use of suggested corrections for errors in cumulative probability counting leads to better use of available counters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New experimental results to demonstrate that the annoying DC in the reconstructed wavefronts from in-line holograms could be successfully eliminated are presented in this paper. The complete elimination of DC has been achieved by making proper use of a Mach-Zehnder interferometer. The results for an in-line hololens and an in-line Fourier transform hologram are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phenomenon of branching at specific angles in streamer breakdown studies is found to be more universal than was ever thought. The angles measured in the breakdown of gases show that the coefficient of field distortion, K, lies in the range from 1 to less than 0.1. The values of K, so obtained agree well with those envisaged in the criterion of the streamer mechanism. It is hoped that branching angles observed in various types of breakdown may, possibly, be explained similarly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During recent decades, thermal and radioactive discharges from nuclear power plants into the aquatic environment have become the subject of lively debate as an ecological concern. The target of this thesis was to summarize the large quantity of results obtained in extensive monitoring programmes and studies carried out in recipient sea areas off the Finnish nuclear power plants at Loviisa and Olkiluoto during more than four decades. The Loviisa NPP is located on the coast of the Gulf of Finland and Olkiluoto NPP on that of the Bothnian Sea. The state of the Gulf of Finland is clearly more eutrophic; the nutrient concentrations in the surface water are about 1½ 2 times higher at Loviisa than at Olkiluoto, and the total phosphorus concentrations still increased in both areas (even doubled at Loviisa) between the early 1970s and 2000. Thus, it is a challenge to distinguish the local effects of thermal discharges from the general eutrophication process of the Gulf of Finland. The salinity is generally low in the brackish-water conditions of the northern Baltic Sea, being however about 1 higher at Olkiluoto than at Loviisa (the salinity of surface water varying at the latter from near to 0 in early spring to 4 6 in late autumn). Thus, many marine and fresh-water organisms live in the Loviisa area close to their limit of existence, which makes the biota sensitive to any additional stress. The characteristics of the discharge areas of the two sites differ from each other in many respects: the discharge area at Loviisa is a semi-enclosed bay in the inner archipelago, where the exchange of water is limited, while the discharge area at Olkiluoto is more open, and the exchange of water with the open Bothnian Sea is more effective. The effects of the cooling water discharged from the power plants on the temperatures in the sea were most obvious in winter. The formation of a permanent ice cover in the discharge areas has been delayed in early winter, and the break-up of the ice occurs earlier in spring. The prolonging of the growing season and the disturbance of the overwintering time, in conditions where the biota has adjusted to a distinct rest period in winter, have been the most significant biological effects of the thermal pollution. The soft-bottom macrofauna at Loviisa has deteriorated to the point of almost total extinction at many sampling stations during the past 40 years. A similar decline has been reported for the whole eastern Gulf of Finland. However, the local eutrophication process seems to have contributed into the decline of the zoobenthos in the discharge area at Loviisa. Thermal discharges have increased the production of organic matter, which again has led to more organic bottom deposits. These have in turn increased the tendency of the isolated deeps to a depletion of oxygen, and this has further caused strong remobilization of phosphorus from the bottom sediments. Phytoplankton primary production and primary production capacity doubled in the whole area between the late 1960s and the late 1990s, but started to decrease a little at the beginning of this century. The focus of the production shifted from spring to mid- and late summer. The general rise in the level of primary production was mainly due to the increase in nutrient concentrations over the whole Gulf of Finland, but the thermal discharge contributed to a stronger increase of production in the discharge area compared to that in the intake area. The eutrophication of littoral vegetation in the discharge area has been the most obvious, unambiguous and significant biological effect of the heated water. Myriophyllum spicatum, Potamogeton perfoliatus and Potamogeton pectinatus, and vigorous growths of numerous filamentous algae as their epiphytes have strongly increased in the vicinity of the cooling water outlet, where they have formed dense populations in the littoral zone in late summer. However, the strongest increase of phytobenthos has extended only to a distance of about 1 km from the outlet, i.e., the changes in vegetation have been largest in those areas that remain ice-free in winter. Similar trends were also discernible at Olkiluoto, but to a clearly smaller extent, which was due to the definitely weaker level of background eutrophy and nutrient concentrations in the Bothnian Sea, and the differing local hydrographical and biological factors prevailing in the Olkiluoto area. The level of primary production has also increased at Olkiluoto, but has remained at a clearly lower level than at Loviisa. In spite of the analogous changes observed in the macrozoobenthos, the benthic fauna has remained strong and diversified in the Olkiluoto area. Small amounts of local discharge nuclides were regularly detected in environmental samples taken from the discharge areas: tritium in seawater samples, and activation products, such as 60Co, 58Co, 54Mn, 110mAg, 51Cr, in suspended particulate matter, bottom sediments and in several indicator organisms (e.g., periphyton and Fucus vesiculosus) that effectively accumulate radioactive substances from the medium. The tritium discharges and the consequent detection frequency and concentrations of tritium in seawater were higher at Loviisa, but the concentrations of the activation products were higher at Olkiluoto, where traces of local discharge nuclides were also observed over a clearly wider area, due to the better exchange of water than at Loviisa, where local discharge nuclides were only detected outside Hästholmsfjärden Bay quite rarely and in smaller amounts. At the farthest, an insignificant trace amount (0.2 Bq kg-1 d.w.) of 60Co originating from Olkiluoto was detected in Fucus at a distance of 137 km from the power plant. Discharge nuclides from the local nuclear power plants were almost exclusively detected at the lower trophic levels of the ecosystems. Traces of local discharge nuclides were very seldom detected in fish, and even then only in very low quantities. As a consequence of the reduced discharges, the concentrations of local discharge nuclides in the environment have decreased noticeably in recent years at both Loviisa and Olkiluoto. Although the concentrations in environmental samples, and above all, the discharge data, are presented as seemingly large numbers, the radiation doses caused by them to the population and to the biota are very low, practically insignificant. The effects of the thermal discharges have been more significant, at least to the wildlife in the discharge areas of the cooling water, although the area of impact has been relatively small. The results show that the nutrient level and the exchange of water in the discharge area of a nuclear power plant are of crucial importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molybdenum oxide films (MoO3) were deposited on glass and crystalline silicon substrates by sputtering of molybdenum target under various oxygen partial pressures in the range 8 × 10−5–8 × 10−4 mbar and at a fixed substrate temperature of 473 K employing dc magnetron sputtering technique. The influence of oxygen partial pressure on the composition stoichiometry, chemical binding configuration, crystallographic structure and electrical and optical properties was systematically studied. X-ray photoelectron spectra of the films formed at 8 × 10−5 mbar showed the presence of Mo6+ and Mo5+ oxidation states of MoO3 and MoO3−x. The films deposited at oxygen partial pressure of 2 × 10−4 mbar showed Mo6+ oxidation state indicating the films were nearly stoichiometric. It was also confirmed by the Fourier transform infrared spectroscopic studies. X-ray diffraction studies revealed that the films formed at oxygen partial pressure of 2 × 10−4 mbar showed the presence of (0 k 0) reflections indicated the layered structure of α-phase MoO3. The electrical conductivity of the films decreased from 3.6 × 10−5 to 1.6 × 10−6 Ω−1 cm−1, the optical band gap of the films increased from 2.93 to 3.26 eV and the refractive index increased from 2.02 to 2.13 with the increase of oxygen partial pressure from 8 × 10−5 to 8 × 10−4 mbar, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical conduction in insulating materials is a complex process and several theories have been suggested in the literature. Many phenomenological empirical models are in use in the DC cable literature. However, the impact of using different models for cable insulation has not been investigated until now, but for the claims of relative accuracy. The steady state electric field in the DC cable insulation is known to be a strong function of DC conductivity. The DC conductivity, in turn, is a complex function of electric field and temperature. As a result, under certain conditions, the stress at cable screen is higher than that at the conductor boundary. The paper presents detailed investigations on using different empirical conductivity models suggested in the literature for HV DC cable applications. It has been expressly shown that certain models give rise to erroneous results in electric field and temperature computations. It is pointed out that the use of these models in the design or evaluation of cables will lead to errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nickel rich NiTi films were sputter deposited on p-doped Si left angle bracket1 0 0right-pointing angle bracket substrates maintained at 300 °C. The films were subsequently solution treated at 700 °C for 30 min followed by ageing at 400 and 500 °C for 5 h. The microstructure of the films was examined by TEM and these studies revealed that the NiTi films were mostly amorphous in the as-deposited condition. The subsequent solution treatment and ageing resulted in crystallization of the films with the film aged at 400 °C exhibiting nanocrystalline grains and three phases viz. B2 (austenite), R and Ni3Ti2 whereas the film aged at 500 °C shows micron sized grains and two phases viz. R and Ni3Ti2. Nanoindentation studies revealed that the nature of the load versus indentation depth response for the films aged at 400 and 500 °C was different. For the same load, the indenter penetrated to a much greater depth for the film aged at 400 °C as compared to the film aged at 500 °C. Also the ratio of the residual indentation depth (hf) to maximum indentation depth (hmax) is lower for the film aged at 400 °C as compared to the film aged at 500 °C. This was attributed to the occurrence of stress induced martensitic transformation of the B2 phase present in the film aged at 400 °C during indentation loading which results in a transformation strain in addition to the normal elastic and plastic strains and its subsequent recovery on unloading. The hardness and elastic modulus measured using the Oliver and Pharr analysis was also found to be lower for the film aged at 400 °C as compared to the film aged at 500 °C which was also primarily attributed to the same effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This three-phase design research describes the modelling processes for DC-circuit phenomena. The first phase presents an analysis of the development of the DC-circuit historical models in the context of constructing Volta s pile at the turn of the 18th century. The second phase involves the designing of a teaching experiment for comprehensive school third graders. Among other considerations, the design work utilises the results of the first phase and research literature of pupils mental models for DC-circuit phenomena. The third phase of the research was concerned with the realisation of the planned teaching experiment. The aim of this phase was to study the development of the external representations of DC-circuit phenomena in a small group of third graders. The aim of the study has been to search for new ways to guide pupils to learn DC-circuit phenomena while emphasing understanding at the qualitative level. Thus, electricity, which has been perceived as a difficult and abstract subject, could be learnt more comprehensively. Especially, the research of younger pupils learning of electricity concepts has not been of great interest at the international level, although DC-circuit phenomena are also taught in the lower classes of comprehensive schools. The results of this study are important, because there has tended to be more teaching of natural sciences in the lower classes of comprehensive schools, and attempts are being made to develop this trend in Finland. In the theoretical part of the research an Experimental-centred representation approach, which emphasises the role of experimentalism in the development of pupil s representations, is created. According to this approach learning at the qualitative level consists of empirical operations like experimenting, observations, perception, and prequantification of nature phenomena, and modelling operations like explaining and reasoning. Besides planning teaching, the new approach can be used as an analysis tool in describing both historical modelling and the development of pupils representations. In the first phase of the study, the research question was: How did the historical models of DC-circuit phenomena develop in Volta s time? The analysis uncovered three qualitative historical models associated with the historical concept formation process. The models include conceptions of the electric circuit as a scene in the DC-circuit phenomena, the comparative electric-current phenomenon as a cause of different observable effect phenomena, and the strength of the battery as a cause of the electric-current phenomenon. These models describe the concept formation process and its phases in Volta s time. The models are portrayed in the analysis using fragments of the models, where observation-based fragments and theoretical fragements are distinguished from each other. The results emphasise the significance of the qualitative concept formation and the meaning of language in the historical modelling of DC-circuit phenomena. For this reason these viewpoints are stressed in planning the teaching experiment in the second phase of the research. In addition, the design process utilised the experimentation behind the historical models of DC-circuit phenomena In the third phase of the study the research question is as follows: How will the small group s external representations of DC-circuit phenomena develop during the teaching experiment? The main question is divided into the following two sub questions: What kind of talk exists in the small group s learning? What kinds of external representations for DC-circuit phenomena exist in the small group discourse during the teaching experiment? The analysis revealed that the teaching experiment of the small group succeeded in its aim to activate talk in the small group. The designed connection cards proved especially successful in activating talk. The connection cards are cards that represent the components of the electric circuit. In the teaching experiment the pupils constructed different connections with the connection cards and discussed, what kinds of DC-circuit phenomena would take place in the corresponding real connections. The talk of the small group was analysed by comparing two situations, firstly, when the small group discussed using connections made with the connection cards and secondly with the same connections using real components. According to the results the talk of the small group included more higher-order thinking when using the connection cards than with similar real components. In order to answer the second sub question concerning the small group s external representations that appeared in the talk during the teaching experiment; student talk was visualised by the fragment maps which incorporate the electric circuit, the electric current and the source voltage. The fragment maps represent the gradual development of the external representations of DC-circuit phenomena in the small group during the teaching experiment. The results of the study challenge the results of previous research into the abstractness and difficulty of electricity concepts. According to this research, the external representations of DC-circuit phenomena clearly developed in the small group of third graders. Furthermore, the fragment maps uncover that although the theoretical explanations of DC-circuit phenomena, which have been obtained as results of typical mental model studies, remain undeveloped, learning at the qualitative level of understanding does take place.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A switched rectifier DC voltage source three-level neutral-point-clamped (NPC) converter topology is proposed here to alleviate the inverter from capacitor voltage balancing in three-level drive systems. The proposed configuration requires only one DC link with a voltage of half of that needed in a conventional NPC inverter. To obtain a rated DC link voltage, the rectifier DC source is alternately connected in parallel to one of the two series capacitors using two switches and two diodes with device voltage ratings of half the total DC bus voltage. The frequency at which the voltage source is switched is independent of the inverter and will not affect its operation since the switched voltage source in this configuration balances the capacitors automatically. The proposed configuration can also be used as a conventional two-level inverter in the lower modulation index range, thereby increasing the reliability of the drivesystem. A space-vector-based PWM scheme is used to verify this proposed topology on a laboratory system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel ZVS auxiliary switch commutated variation for all DGDC converter topologies has been proposed in 2006. With proper designation of the circuit variables (throw current I and the pole voltage V), all these converters are seen to be governed by an identical set of equations. With idealized switches, the steady-state performance is obtainable in an analytical form. The conversion ratio of the converter topologies is obtained. A generalized equivalent circuit emerges for all these converters from the steady-state conversion ratio. It also provides a dynamic model as well. With these generalized steady-state equivalent circuits, small signal analysis of these converters may be carried out readily. It enables one to use the familiar state space averaged results of the standard PWM DGDC converters for the resonant counterparts. Th dc and ac models reveals that dc and low frequency behaviour of the proposed family of converters is similiar to that of its PWM parent

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An algorithm for optimal allocation of reactive power in AC/DC system using FACTs devices, with an objective of improving the voltage profile and also voltage stability of the system has been presented. The technique attempts to utilize fully the reactive power sources in the system to improve the voltage stability and profile as well as meeting the reactive power requirements at the AC-DC terminals to facilitate the smooth operation of DC links. The method involves successive solution of steady-state power flows and optimization of reactive power control variables with Unified Power Flow Controller (UPFC) using linear programming technique. The proposed method has been tested on a real life equivalent 96-bus AC and a two terminal DC system under normal and contingency conditions.