835 resultados para Continuum of care


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Annual report for the Iowa Veterans Home. To provide a continuum of care to Iowa’s veterans and their spouses in an environment focusing on individualized services to enhance their quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction New evidence from randomized controlled and etiology of fever studies, the availability of reliable RDT for malaria, and novel technologies call for revision of the IMCI strategy. We developed a new algorithm based on (i) a systematic review of published studies assessing the safety and appropriateness of RDT and antibiotic prescription, (ii) results from a clinical and microbiological investigation of febrile children aged <5 years, (iii) international expert IMCI opinions. The aim of this study was to assess the safety of the new algorithm among patients in urban and rural areas of Tanzania.Materials and Methods The design was a controlled noninferiority study. Enrolled children aged 2-59 months with any illness were managed either by a study clinician using the new Almanach algorithm (two intervention health facilities), or clinicians using standard practice, including RDT (two control HF). At day 7 and day 14, all patients were reassessed. Patients who were ill in between or not cured at day 14 were followed until recovery or death. Primary outcome was rate of complications, secondary outcome rate of antibiotic prescriptions.Results 1062 children were recruited. Main diagnoses were URTI 26%, pneumonia 19% and gastroenteritis (9.4%). 98% (531/541) were cured at D14 in the Almanach arm and 99.6% (519/521) in controls. Rate of secondary hospitalization was 0.2% in each. One death occurred in controls. None of the complications was due to withdrawal of antibiotics or antimalarials at day 0. Rate of antibiotic use was 19% in the Almanach arm and 84% in controls.Conclusion Evidence suggests that the new algorithm, primarily aimed at the rational use of drugs, is as safe as standard practice and leads to a drastic reduction of antibiotic use. The Almanach is currently being tested for clinician adherence to proposed procedures when used on paper or a mobile phone

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Within the framework of the «Programme cantonal Diabète», we aimed at collecting data to 1) describe the population of diabetic patients in the canton of Vaud, and 2) assess the quality of their care. Methods: A cross-sectional study was conducted in the fall of 2011. Out of 140 randomly selected community pharmacies registered in the canton of Vaud, 56 accepted to participate in patients' recruitment. Noninstitutionalized adult diabetic patients (disease duration >12 months) visiting a pharmacy with a prescription for oral anti-diabetic drugs, insulin, glycemic strips or glucose meter were eligible. Patients not residing in the canton of Vaud, not speaking and understanding French well enough, presenting obvious cognitive impairment, and women with gestational diabetes, were excluded. Using a self-administered questionnaire, data was collected on patients' characteristics and diabetes as well as various process (e.g. recommended annual screenings) and outcomes quality of care indicators. Descriptive analyses were performed. Results: A total of 406 patients with diabetes participated. Mean age was 64 years, 41% were women and 63% were married. Patients reported type 1, 2 and other types of diabetes in 13%, 69% and 19%, respectively. They were treated with oral anti-diabetic drugs, insulin or both in 50%, 23% and 27% of the cases. Half of the patients did not report any diabetes-related complication. Glucose self-monitoring was reported by 82% of the patients. Of those who were aware of HbA1C (n = 218), 98% reported at least one HbA1C control during the last 12 months. During that same time frame, 97% and 95% reported at least one blood pressure and weight measure, 94% reported having had a cholesterol check, 74%, 68% and 64% had eyes, feet and urine screening respectively. 62% of the patients had been immunized against influenza. At least 76% of the patients had a minimum of 5 of the 7 described process indicators performed during the last 12 months. Among patients who knew the value (n = 145), mean HbA1C was 7.4 (SD 1.2). Conclusion: This study targeting community-based diabetic patients shows that while routine clinical and laboratory tests were annually performed in the vast majority of patients, feet and urine screening, as well as influenza immunization, were less often reported by patients. The proportion of patients with diabetes having had at least 5 out of the 7 annual screenings performed was nevertheless very high.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number of patients treated by haemodialysis (HD) is continuously increasing. The complications associated with vascular accesses represent the first cause of hospitalisation in these patients. Since 2001 nephrologists, surgeons, angiologists and radiologists at the CHUV are working to develop a multidisciplinary model that includes planning and monitoring of HD accesses. In this setting the echo-Doppler represents an important tool of investigation. Every patient is discussed and decisions are taken during a weekly multidisciplinary meeting. A network has been created with nephrologists of peripheral centres and other specialists. This model allows to centralize investigational information and coordinate patient care while keeping and even developing some investigational activities and treatment in peripheral centres.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Self-report of diabetes care has moderate validity and is prone to under- and over-reporting. We assessed reproducibility of a range of processes and outcomes of diabetes care as reported by patients and physicians. METHODS: In a Swiss community-based survey, patients with diabetes and physicians independently reported past 12 months processes of care (HbA1c, lipids, microalbuminuria, blood pressure, weight, foot and eye examinations) and last measured values of HbA1c, height, weight and blood pressure. For dichotomous variables, we assessed reliability by Cohen's kappa and agreement by uniform kappa. For continuous measures, we used Lin's concordance correlation coefficient and limits of agreement, respectively. RESULTS: Mean age of the 210 patients was 65 years; 40% were women, and 51% had diabetes for >10 years. Agreement was good for recommended processes of care such as blood pressure (uniform kappa = 0.94), HbA1c (0.93), weight (0.88) and lipid (0.78), but lower for microalbuminuria, foot and eye examinations (all <0.50). Cohen's kappa values were all low (<0.25). Comparisons of reported continuous variables showed large limits of agreement for height (±6 cm) and weight (8-10 kg) despite high concordance correlation coefficients (0.93 and 0.97). Concordance correlation coefficients were smaller for HbA1c (0.72) and blood pressure (0.5-0.6), with large limits of agreement (±2% and ±25 mmHg). CONCLUSION: While agreement of routine processes of care was good, agreement was less satisfactory for microalbuminuria, foot and eye examinations. Reports of continuous outcomes yielded good reliability but too wide limits of agreement. Quality of care evaluation relying on self-report only should be made cautiously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite moderate improvements in outcome of glioblastoma after first-line treatment with chemoradiation recent clinical trials failed to improve the prognosis of recurrent glioblastoma. In the absence of a standard of care we aimed to investigate institutional treatment strategies to identify similarities and differences in the pattern of care for recurrent glioblastoma. We investigated re-treatment criteria and therapeutic pathways for recurrent glioblastoma of eight neuro-oncology centres in Switzerland having an established multidisciplinary tumour-board conference. Decision algorithms, differences and consensus were analysed using the objective consensus methodology. A total of 16 different treatment recommendations were identified based on combinations of eight different decision criteria. The set of criteria implemented as well as the set of treatments offered was different in each centre. For specific situations, up to 6 different treatment recommendations were provided by the eight centres. The only wide-range consensus identified was to offer best supportive care to unfit patients. A majority recommendation was identified for non-operable large early recurrence with unmethylated MGMT promoter status in the fit patients: here bevacizumab was offered. In fit patients with late recurrent non-operable MGMT promoter methylated glioblastoma temozolomide was recommended by most. No other majority recommendations were present. In the absence of strong evidence we identified few consensus recommendations in the treatment of recurrent glioblastoma. This contrasts the limited availability of single drugs and treatment modalities. Clinical situations of greatest heterogeneity may be suitable to be addressed in clinical trials and second opinion referrals are likely to yield diverging recommendations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Implantar um novo modelo de cuidado ao parto e reduzir o percentual de cesarianas entre as gestantes da UNIMED Jaboticabal.MÉTODOS: Estudo descritivo desenvolvido em uma instituição do interior paulista, que teve início em 2012 e propôs o redesenho do modelo de cuidado ao parto com a revisão de todo o processo assistencial por meio da Ciência da Melhoria Contínua. Para medir os resultados das mudanças, foram selecionados nove indicadores e suas respectivas metas.RESULTADOS: O indicador de partos vaginais atingiu a meta de 40%, após sete meses do início da intervenção. Este indicador entre as gestantes do SUS atingiu 66%. A taxa de mortalidade perinatal decresceu 25% comparando-se 2012 a 2014 e a taxa de prematuridade foi de 3/100 nascidos vivos em 2014. O percentual de gestantes da UNIMED com 6 ou mais consultas de pré-natal atingiu 95%. Em relação aos custos hospitalares per capita referentes à assistência ao parto, notou-se um decréscimo de 27%, quando comparados os anos de 2012 e 2013. Tal queda não se sustentou e o custo hospitalar per capita, em 2014, retornou aos mesmos patamares de 2012. A remuneração dos obstetras registrou um acréscimo de 72%, se comparados os anos de 2012, 2013 e 2014. Houve queda de 61% dos custos com a unidade de terapia intensiva (UTI) neonatal, comparando os anos de 2012 e 2013. A taxa de admissão em UTI neonatal acompanhou a redução dos custos e foi de 55%, se comparados os anos de 2012 a 2014, entre as gestantes da UNIMED. Não houve o alcance da meta de 80% de participação das gestantes nos cursos de preparação para o nascimento. A porcentagem de gestantes satisfeitas e muito satisfeitas com a assistência ao parto atingiu 86%.CONCLUSÃO: Este projeto atingiu seus objetivos, reduzindo o percentual de cesarianas entre as gestantes da UNIMED Jaboticabal, e constituiu-se em um exemplo concreto da realização do triplo objetivo em saúde: melhorar a experiência dos envolvidos e os resultados de saúde de populações e indivíduos e realizar estas duas tarefas com menor custo, eliminando desperdícios assistenciais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiac troponins (cTn) I and T are the current golden standard biochemical markers in the diagnosis and risk stratification of patients with suspected acute coronary syndrome. During the past few years, novel assays capable of detecting cTn‐concentrations in >50% of apparently healthy individuals have become readily available. With the emerging of these high sensitivity cTn assays, reductions in the assay specificity have caused elevations in the measured cTn levels that do not correlate with the clinical picture of the patient. The increased assay sensitivity may reveal that various analytical interference mechanisms exist. This doctoral thesis focused on developing nanoparticle‐assisted immunometric assays that could possibly be applied to an automated point‐ofcare system. The main objective was to develop minimally interference‐prone assays for cTnI by employing recombinant antibody fragments. Fast 5‐ and 15‐minute assays for cTnI and D‐dimer, a degradation product of fibrin, based on intrinsically fluorescent nanoparticles were introduced, thus highlighting the versatility of nanoparticles as universally applicable labels. The utilization of antibody fragments in different versions of the developed cTnI‐assay enabled decreases in the used antibody amounts without sacrificing assay sensitivity. In addition, the utilization of recombinant antibody fragments was shown to significantly decrease the measured cTnI concentrations in an apparently healthy population, as well as in samples containing known amounts of potentially interfering factors: triglycerides, bilirubin, rheumatoid factors, or human anti‐mouse antibodies. When determining the specificity of four commercially available antibodies for cTnI, two out of the four cross‐reacted with skeletal troponin I, but caused crossreactivity issues in patient samples only when paired together. In conclusion, the results of this thesis emphasize the importance of careful antibody selection when developing cTnI assays. The results with different recombinant antibody fragments suggest that the utilization of antibody fragments should strongly be encouraged in the immunoassay field, especially with analytes such as cTnI that require highly sensitive assay approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Termiä sepsis käytetään infektion aiheuttamasta yleisestä tulehdusreaktio-oireyhtymästä. Biokemiallinen merkkiaine eli biomarkkeri on aine, joka objektiivisesti mitattuna ja arvioituna toimii indikaattorina erottaen toisistaan normaalit biologiset prosessit ja patogeeniset prosessit. Lisäksi biomarkkeri saattaa osoittaa farmakologisen vasteen lääkehoidolle. Tutkielman kirjallisessa osassa on esitelty ja verrattu toisiinsa jo kliinisessä käytössä olevia sekä lupaavia, vielä tutkimusvaiheessa olevia, sepsiksen biomerkkiaineita. Lisäksi tutkielmassa on tarkasteltu sepsiksen todentamisen, tunnistamisen ja hoidon tulevaisuudennäkymiä. Prokalsitoniini (PCT) on eräs jo kliinisessä käytössä oleva sepsiksen biomerkkiaine. Tutkielman kokeellisessa osassa pystytettiin teho-osastoille suunnattu pikatesti PCT:n mittaamiseen aikaerotteista fluoresenssiteknologiaa hyödyntävälle AQT-järjestelmälle (DHR Finland Oy, Innotrac Diagnostics, Suomi). Järjestelmä mittaa 20–30 minuutissa biomerkkiainepitoisuuden. Tavoitteena oli löytää sopiva vasta-ainepari ja pystyttää kaksipuoleinen immunomääritys, jonka analyyttinen herkkyys on alle 0,02 ng/ml:ssa. Työssä tutkittiin biotinyloidun kokonaisen vasta-aineen ja paikkaspesifisesti biotinyloidun antigeenia sitovan fragmentin (engl. fragment antigen binding, Fab) toimivuutta sitojamolekyylinä. Lisäksi työssä verrattiin kahden eri leimamolekyylin, 9 hampaisen europiumkelaatin sekä Innotracissa kehitetyn tähtikelaatin, toimivuutta PCT-immunomäärityksessä. Vasta-aineiden mahdolliset ristireaktiot testattiin ja määritystä testattiin alustavasti eri näytematriiseissa. Työssä löydettiin 5 vasta-aineparia, joiden analyyttinen herkkyys oli alle 0,02 ng/ml:ssa. Aiemmin testattuja vasta-ainepareja parempi analyyttinen herkkyys johtui todennäköisesti yhden uuden leimavasta-aineen paremmasta affiniteetistä. Tähtikelaatilla leimatulla vasta-aineella analyyttinen herkkyys parani lähes viisinkertaisesti, kun sitä verrattiin 9-hampaisella euroopiumkelaatilla leimatun vasta-aineen määritykseen. Havaittiin myös, että Fab-fragmentilla mitattiin määrityksissä lähes kaksi kertaa suuremmat signaali-taustasuhteet, kun sitä verrattiin kokonaiseen vasta-aineeseen, tietyllä vasta-aineparilla. Tämä johtui luultavasti steeristen esteiden vähenemisestä. Näytematriisilla ei todettu olevan vaikutusta määritykseen, eikä ristireaktioita havaittu. Kehitetyn määrityksen suoriutumista verrattiin markkinoilla olevaan BRAHMS AG:n (Saksa) PCT-määritykseen käyttäen potilasnäytteitä. Korrelaatiokertoimet potilasnäytevertailuissa olivat 0,965–0,989 ja näytteiden mitatuissa pitoisuuksissa oli tasoero.