707 resultados para Contact electrodes
Resumo:
Background: Contact endoscopy (CE) was initially described as a method used in the analysis of uterine and vocal folds histology. The first nasal cavity CE studies achieved promising results regarding its use for the differentiation between benign and malignant lesions, considering that biopsy might cause some complications, especially bleeding. This study described and compared the findings of CE on inverted papilloma and nasosinusal squamous cell carcinoma (SCC) and tested the effectiveness of this exam as a noninvasive method for in vivo differentiation between these tumors. Methods: The patients included in this study were divided into group A, patients diagnosed with inverted papilloma, and group B, patients diagnosed with SCC. CE results were compared among themselves. CE images were presented to examiners not experienced with the method. Results: Twenty-two patients were examined, 13 in group A and 9 in group B. The main relevant differences in CE findings between those two groups were corkscrew vessels, presence of mitoses, keratinization and nuclear pleomorphism in carcinoma, and vacuolated cells in papilloma. The examiners were capable of defining the diagnosis of these nasal tumors only based on CE images. Conclusion: CE may be a useful noninvasive exam to be used in the in vivo diagnosis of inverted papilloma and nasosinusal SCC, which may enable better preoperative planning. (Am J Rhinol Allergy 24, 210-214, 2010; doi: 10.2500/ajra.2010.24.3467)
Resumo:
To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Stimulating neural electrodes are required to deliver charge to an environment that presents itself as hostile. The electrodes need to maintain their electrical characteristics (charge and impedance) in vivo for a proper functioning of neural prostheses. Here we design implantable multi-walled carbon nanotubes coating for stainless steel substrate electrodes, targeted at wide frequency stimulation of deep brain structures. In well-controlled, low-frequency stimulation acute experiments, we show that multi-walled carbon nanotube electrodes maintain their charge storage capacity (CSC) and impedance in vivo. The difference in average CSCs (n = 4) between the in vivo (1.111 mC cm(-2)) and in vitro (1.008 mC cm(-2)) model was statistically insignificant (p > 0.05 or P-value = 0.715, two tailed). We also report on the transcription levels of the pro-inflammatory cytokine IL-1 beta and TLR2 receptor as an immediate response to low-frequency stimulation using RT-PCR. We show here that the IL-1 beta is part of the inflammatory response to low-frequency stimulation, but TLR2 is not significantly increased in stimulated tissue when compared to controls. The early stages of neuroinflammation due to mechanical and electrical trauma induced by implants can be better understood by detection of pro-inflammatory molecules rather than by histological studies. Tracking of such quantitative response profits from better analysis methods over several temporal and spatial scales. Our results concerning the evaluation of such inflammatory molecules revealed that transcripts for the cytokine IL-1 beta are upregulated in response to low-frequency stimulation, whereas no modulation was observed for TLR2. This result indicates that the early response of the brain to mechanical trauma and low-frequency stimulation activates the IL-1 beta signaling cascade but not that of TLR2.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objectives: To determine the differences between tympanic and extratympanic electrodes regarding recording technique, comfort and ease of execution of the exam, and quality of auditory potential tracings. Study Design: Prospective cross-section investigation. Methods: Determination of the summation potential/action potential (SP/AP) ratio by electrocochleography (EchoG) using tympanic and extratympanic electrodes and separate analysis of SP and AP regarding the amplitude recorded. Results: Twenty-three subjects (15 men and 8 women; mean age: 33.17 years) with normal tonal threshold audiometry were evaluated. EchoG analysis revealed no significant difference between the two tympanic electrodes. Eleven of the 23 subjects reported discomfort with the insertion of the tympanic electrode even with the use of topical xylocaine, whereas no complaints of discomfort were reported with the use of the extratympanic electrode. Conclusions: Both electrodes were effective for EchoG evaluation, but the extratympanic one was easier to insert and did not cause discomfort. However, the tympanic electrode produced tracings of greater amplitude and of better reproducibility. Laryngoscope, 119:563-566, 2009
Resumo:
In this paper, an attempt was made to investigate a fundamental problem related to the flexural waves excited by rectangular transducers. Due to the disadvantages of the Green's function approach for solving this problem, a direct and effective method is proposed using a multiple integral transform method and contour integration technique. The explicit frequency domain solutions obtained from this newly developed method are convenient for understanding transducer behavior and theoretical optimization and experimental calibration of rectangular transducers. The time domain solutions can then be easily obtained by using the fast Fourier transform technique. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The acousto-ultrasonic (AU) input-output characteristics for contact-type transmitting and receiving transducers coupled to composite laminated plates are considered in this paper. Combining a multiple integral transform method, an ordinary discrete layer theory for the laminates and some simplifying assumptions for the electro-mechanical transduction behaviour of the transducers, an analytical solution is developed which can deal with all the wave processes involved in the AU measurement system, i.e, wave generation, wave propagation and wave reception. The spectral response of the normal contact pressure sensed by the receiving transducer due to an arbitrary input pulse excited by the transmitting transducer is obtained. To validate the new analytical-numerical spectral technique in the low-frequency regime, the results are compared with Mindlin plate theory solutions. Based on the analytical results, numerical calculations are carried out to investigate the influence of various external parameters such as frequency content of the input pulse, transmitter/receiver spacing and transducer aperture on the output of the measurement system. The results show that the presented analytical-numerical procedure is an effective tool for understanding the input-output characteristics of the AU technique for laminated plates. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
We obtain the finite-temperature unconditional master equation of the density matrix for two coupled quantum dots (CQD's) when one dot is subjected to a measurement of its electron occupation number using a point contact (PC). To determine how the CQD system state depends on the actual current through the PC device, we use the so-called quantum trajectory method to derive the zero-temperature conditional master equation. We first treat the electron tunneling through the PC barrier as a classical stochastic point process (a quantum-jump model). Then we show explicitly that our results can be extended to the quantum-diffusive limit when the average electron tunneling rate is very large compared to the extra change of the tunneling rate due to the presence of the electron in the dot closer to the PC. We find that in both quantum-jump and quantum-diffusive cases, the conditional dynamics of the CQD system can be described by the stochastic Schrodinger equations for its conditioned state vector if and only if the information carried away from the CQD system by the PC reservoirs can be recovered by the perfect detection of the measurements.
Resumo:
Dysfunction of the articulatory subsystem (i.c.. the lips, tongue, and jaw) has bccn identified as a major contributor to the reduction in speech intelligibility experienced by a high proportion of people with multiple sclerosis (MS). In particular. consonant imprecision has been reported to be the articulatory deficit that contributes most to variations in overall intelligibility of MS speakers. Electropalatography(EPG) IS an instrurncntal technique that visually documents the location and timing of tongue-topalatc contacts during speech. Although such a technique would be valuablc in objectively assessing the articulatory disturbances exhibited by individuals with dysarthria ia motor speech disorder) associated with MS, to-date no such study ha< been reported. The aim of the present study was to use EPG to assess tongue-to-palate contact patterns and articulatory timing in patients with dysarthria associated with MS. A dysarthric participant with a diagnosis of definite MS was fitted with an acrylic EPG palate (Reading EPG.?) and asked to read aloud a list of single syllable words which contained lingual consonants in the word-initial position and in consonant clusters. Each mord was repeated five times. The EPG palate was specifically moulded to tit the participant's hard palate and contained 62 electrodes that detected the tongue contacts. A non-neurologically impaired participant matched for age and sex servcd as a control. The results of the study revealed that the tongue-to-palate contacts produced by the participant with MS varied from those produced by the control in a number of ways in regard to spatial configurations and timing characteristics exhibited. The rcsults arc discussed in relation to the neuropathophysiological effects of MS on speech production. The potcntial use of EPG in programs for treating speech disorders associated with MS will be highlightcd.
Resumo:
The efficacy of psychological treatments emphasising a self-management approach to chronic pain has been demonstrated by substantial empirical research. Nevertheless, high drop-out and relapse rates and low or unsuccessful engagement in self-management pain rehabilitation programs have prompted the suggestion that people vary in their readiness to adopt a self-management approach to their pain. The Pain Stages of Change Questionnaire (PSOCQ) was developed to assess a patient's readiness to adopt a self-management approach to their chronic pain. Preliminary evidence has supported the PSOCQ's psychometric properties. The current study was designed to further examine the psychometric properties of the PSOCQ, including its reliability, factorial structure and predictive validity. A total of 107 patients with an average age of 36.2 years (SD = 10.63) attending a multi-disciplinary pain management program completed the PSOCQ, the Pain Self-Efficacy Questionnaire (PSEQ) and the West Haven-Yale Multidimensional Pain Inventory (WHYMPI) pre-admission and at discharge from the program. Initial data analysis found inadequate internal consistencies of the precontemplation and action scales of the PSOCQ and a high correlation (r = 0.66, P < 0.01) between the action and maintenance scales. Principal component analysis supported a two-factor structure: 'Contemplation' and 'Engagement'. Subsequent analyses revealed that the PSEQ was a better predictor of treatment outcome than the PSOCQ scales. Discussion centres upon the utility of the PSOCQ in a clinical pain setting in light of the above findings, and a need for further research. (C) 2002 International Association for the Study of Pain. Published by Elsevier Science B.V. All rights reserved.
Resumo:
A miniature pressure transducer was used to assess the interlabial contact pressures produced by a group of 19 adults (mean age 30.6 years) with dysarthria following severe traumatic brain injury (TBI) during a set of speech and nonspeech tasks. Ten parameters relating to lip strength, endurance, rate of movement and lip pressure accuracy and stability were measured from the nonspeech tasks. The results attained by the TBI group were compared against a group of 19 age- and sex-matched control subjects. Significant differences between the groups were found for maximum interlabial contact pressure, maximum rate of repetition of maximum pressure, and lip pressure accuracy at 50 and 10% levels of maximum pressure. In regards to speech, the interlabial contact pressures generated by the TBI group and control group did not differ significantly. When expressed as percentages of maximum pressure, however, the TBI group's interlabial pressures appeared to have been generated with greater physiological effort. Copyright (C) 2002 S. Karger AG, Basel.
Resumo:
A new algorithm has been developed for smoothing the surfaces in finite element formulations of contact-impact. A key feature of this method is that the smoothing is done implicitly by constructing smooth signed distance functions for the bodies. These functions are then employed for the computation of the gap and other variables needed for implementation of contact-impact. The smoothed signed distance functions are constructed by a moving least-squares approximation with a polynomial basis. Results show that when nodes are placed on a surface, the surface can be reproduced with an error of about one per cent or less with either a quadratic or a linear basis. With a quadratic basis, the method exactly reproduces a circle or a sphere even for coarse meshes. Results are presented for contact problems involving the contact of circular bodies. Copyright (C) 2002 John Wiley Sons, Ltd.