840 resultados para Computer-assisted instruction--Evaluation.
Resumo:
Testing was conducted of a computer-assisted system for matching humpback whale tail flukes photographs. Trials with a 12,000-photographs database found no differences in match success between matching by computer and matching by comparing smaller catalogs ranging in size from 200 to 400 photographs. Tests with a 24,000-photographs database showed that, on average, the first match was found after examining about 130 photographs whether the photograph quality was excellent, good, or poor. Match success did not appear to be strongly related to whether the tail flukes had especially distinctive markings or pigment patterns (recognition quality). An advantage of computer-assisted matching is the ability to compare new photographs to the entire North Pacific collection, where no bias is introduced based on expectation of resightings within or between specific areas, or based on expectation of behavioral role (e.g. matching “known” females to “known” females).
Resumo:
A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.
Resumo:
Computer-assisted pathological immunohistochemistry scoring is more time-effective than conventional scoring, but provides no analytical advantage
Resumo:
Tese de doutoramento, Farmácia (Química Farmacêutica e Terapêutica), Universidade de Lisboa, Faculdade de Farmácia, 2014
Resumo:
The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.
Resumo:
Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.
Resumo:
This paper presents two studies, both examining the efficacy of a computer programme (Captain's Log) in training attentional skills. The population of interest is the traumatically brain injured. Study #1 is a single-case design that offers recommendations for the second, .larger (N=5) inquiry. Study #2 is an eight-week hierarchical treatment programme with a multi-based testing component. Attention, memory, listening comprehension, locus-of-control, self-esteem, visuo-spatial, and general outcome measures are employed within the testing schedule. Results suggest that any improvement was a result of practice effects. With a few single-case exceptions, the participants showed little improvement in the dependent measures.
Resumo:
This study had three purposes related to the effective implem,entation and practice of computer-mediated online distance education (C-MODE) at the elementary level: (a) To identify a preliminary framework of criteria 'or guidelines for effective implementation and practice, (b) to identify areas ofC-MODE for which criteria or guidelines of effectiveness have not yet been developed, and (c) to develop an implementation and practice criteria questionnaire based on a review of the distance education literature, and to use the questionnaire in an exploratory survey of elementary C-MODE practitioners. Using the survey instrument, the beliefs and attitudes of 16 elementary C'- MODE practitioners about what constitutes effective implementation and practice principles were investigated. Respondents, who included both administrators and instructors, provided information about themselves and the program in which they worked. They rated 101 individual criteria statenlents on a 5 point Likert scale with a \. point range that included the values: 1 (Strongly Disagree), 2 (Disagree), 3 (Neutral or Undecided), 4 (Agree), 5 (Strongly Agree). Respondents also provided qualitative data by commenting on the individual statements, or suggesting other statements they considered important. Eighty-two different statements or guidelines related to the successful implementation and practice of computer-mediated online education at the elementary level were endorsed. Response to a small number of statements differed significantly by gender and years of experience. A new area for investigation, namely, the role ofparents, which has received little attention in the online distance education literature, emerged from the findings. The study also identified a number of other areas within an elementary context where additional research is necessary. These included: (a) differences in the factors that determine learning in a distance education setting and traditional settings, (b) elementary students' ability to function in an online setting, (c) the role and workload of instructors, (d) the importance of effective, timely communication with students and parents, and (e) the use of a variety of media.
Resumo:
Please consult the paper edition of this thesis to read. It is available on the 5th Floor of the Library at Call Number: Z 9999 E38 D56 1992
Resumo:
Pedicle screw insertion technique has made revolution in the surgical treatment of spinal fractures and spinal disorders. Although X- ray fluoroscopy based navigation is popular, there is risk of prolonged exposure to X- ray radiation. Systems that have lower radiation risk are generally quite expensive. The position and orientation of the drill is clinically very important in pedicle screw fixation. In this paper, the position and orientation of the marker on the drill is determined using pattern recognition based methods, using geometric features, obtained from the input video sequence taken from CCD camera. A search is then performed on the video frames after preprocessing, to obtain the exact position and orientation of the drill. An animated graphics, showing the instantaneous position and orientation of the drill is then overlaid on the processed video for real time drill control and navigation
Resumo:
Introduction for UG course on TEL
Resumo:
Se elabora un proyecto piloto encaminado a la armonizaci??n y convergencia de la ense??anza universitaria en el Espacio Europeo de Educaci??n Superior, mediante el dise??o y aplicaci??n de experiencias de innovaci??n en nuevos sistemas de evaluaci??n de competencias mediante la aplicaci??n de las TIC en la evaluaci??n educativa. Se aplica el dise??o experimental en Educaci??n y en Biom??dicas, para comprobar la eficiencia del uso de un software espec??fico para la evaluaci??n formativa frente a otros sistemas tradicionales. El uso de procesos de evaluaci??n a trav??s de la red, se orientan a resaltar la importancia del feed-back y el efecto que ello tiene en el aprendizaje del estudiante. El proyecto se desarrolla en tres fases. La primera, de recogida de informaci??n, selecci??n de las asignaturas de la aplicaci??n de la experiencia y dise??o de la investigaci??n. La segunda fase, de implementaci??n de la experiencia en dos ??reas de Educaci??n y Biom??dicas, y en una tercera fase, de validaci??n emp??rica de la experiencia a trav??s del an??lisis estad??stico de datos recogidos en la fase pre y postest. Se elaboran pruebas diferentes de evaluaci??n espec??ficas para los distintos objetivos y contenidos de las dos ??reas de estudio.