906 resultados para Comparison of performance
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to compare time-motion indicators during judo matches performed by athletes from different age groups. The following age groups were analysed: Pre-Juvenile (13-14 years, n=522), Juvenile (15-16 years, n 353); Junior (19 years, n = 349) and Senior (>20 years, n = 587). The time-motion indicators included: Total Combat Time, Standing Combat Time, Displacement Without Contact, Gripping Time, Groundwork Combat Time and Pause Time. Analysis of variance (ANOVA) one-way and the Tukey test, as well as the Kruskal-Wallis test and Mann-Whitney (for non-parametric data), were conducted, using P < 0.05 as significance level. The results showed that all analysed groups obtained a median of 7 (first quantile - 3, third quantile - 12) sequences of combat/pause cycles. In total time of combat, the result was: for Total Combat Time, Standing Combat Time and Gripping Time: Pre-Juvenile and Senior were significantly longer than Juvenile and Junior. Considering Displacement Without Contact, Junior was significantly longer than all other age groups. For Groundwork Combat Time, Senior was significantly longer than all other age groups and Pre-Juvenile was longer than Junior. These results can be used to improve the physiological performance in intermittent practices, as well as technicaltactical training during judo sessions.
Resumo:
The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.
Resumo:
Background Synchronization programs have become standard in the dairy industry in many countries. In Switzerland, these programs are not routinely used for groups of cows, but predominantly as a therapy for individual problem cows. The objective of this study was to compare the effect of a CIDR-Select Synch and a 12-d CIDR protocol on the pregnancy rate in healthy, multiparous dairy cows in Swiss dairy farms. Methods Cows (N = 508) were randomly assigned to CIDR-Select Synch (N = 262) or 12-d CIDR (N = 246) protocols. Cows in the CIDR-Select Synch group received a CIDR and 2.5 ml of buserelin i.m. on d 0. On d 7, the CIDR insert was removed and 5 ml of dinoprost was administered i.m.. Cows in the 12-d CIDR group received the CIDR on d 0 and it was removed on d 12 (the routine CIDR protocol in Swiss dairies). On d 0 a milk sample for progesterone analysis was taken. Cows were inseminated upon observed estrus. Pregnancy was determined at or more than 35 days after artificial insemination. As a first step, the two groups were compared as to indication for treatment, breed, stud book, stall, pasture, and farmer's business using chi square tests or Fisher's exact test. Furthermore, groups were compared as to age, DIM, number of AI's, number of cows per farm, and yearly milk yield per cow using nonparametric ANOVA. A multiple logistic model was used to relate the success of the protocols to all of the available factors; in particular treatment (CIDR-Select Synch/12-d CIDR), milk progesterone value, age, DIM, previous treatment of the uterus, previous gynecological treatment, and number of preceding inseminations. Results The pregnancy rate was higher in cows following the CIDR-Select Synch compared to the 12-d CIDR protocol (50.4% vs. 22.4%; P < 0.0001). Conclusion The CIDR-Select Synch protocol may be highly recommended for multiparous dairy cows. The reduced time span of the progesterone insert decreased the number of days open, improved the pregnancy rate compared to the 12-d CIDR protocol and the cows did not to have to be handled more often.
Resumo:
The objective of our study was to compare the effect of dual-energy subtraction and bone suppression software alone and in combination with computer-aided detection (CAD) on the performance of human observers in lung nodule detection.
Resumo:
The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.
Resumo:
Patients with amnestic mild cognitive impairment are at high risk for developing Alzheimer's disease. Besides episodic memory dysfunction they show deficits in accessing contextual knowledge that further specifies a general spatial navigation task or an executive function (EF) virtual action planning. There has been only one previous work with virtual reality and the use of a virtual action planning supermarket for the diagnosis of mild cognitive impairment. The authors of that study examined the feasibility and the validity of the virtual action planning supermarket (VAP-S) for the diagnosis of patients with mild cognitive impairment (MCI) and found that the VAP-S is a viable tool to assess EF deficits. In our study we employed the in-house platform of virtual action planning museum (VAP-M) and a sample of 25 MCI and 25 controls, in order to investigate deficits in spatial navigation, prospective memory and executive function. In addition, we used the morphology of late components in event-related potential (ERP) responses, as a marker for cognitive dysfunction. The related measurements were fed to a common classification scheme facilitating the direct comparison of both approaches. Our results indicate that both the VAP-M and ERP averages were able to differentiate between healthy elders and patients with amnestic mild cognitive impairment and agree with the findings of the virtual action planning supermarket (VAP-S). The sensitivity (specificity) was 100% (98%) for the VAP-M data and 87%(90%) for the ERP responses. Considering that ERPs have proven to advance the early detection and diagnosis of "presymptomatic AD", the suggested VAP-M platform appears as an appealing alternative.
Resumo:
Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.
Resumo:
One of the most demanding needs in cloud computing and big data is that of having scalable and highly available databases. One of the ways to attend these needs is to leverage the scalable replication techniques developed in the last decade. These techniques allow increasing both the availability and scalability of databases. Many replication protocols have been proposed during the last decade. The main research challenge was how to scale under the eager replication model, the one that provides consistency across replicas. This thesis provides an in depth study of three eager database replication systems based on relational systems: Middle-R, C-JDBC and MySQL Cluster and three systems based on In-Memory Data Grids: JBoss Data Grid, Oracle Coherence and Terracotta Ehcache. Thesis explore these systems based on their architecture, replication protocols, fault tolerance and various other functionalities. It also provides experimental analysis of these systems using state-of-the art benchmarks: TPC-C and TPC-W (for relational systems) and Yahoo! Cloud Serving Benchmark (In- Memory Data Grids). Thesis also discusses three Graph Databases, Neo4j, Titan and Sparksee based on their architecture and transactional capabilities and highlights the weaker transactional consistencies provided by these systems. It discusses an implementation of snapshot isolation in Neo4j graph database to provide stronger isolation guarantees for transactions.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
"Project no. 9-38-01-000 T 204, Contract no. DA 44-177- TC-462."
Resumo:
The study was a comparison of bioassay and HPLC analysis of artesunate (ARTS) and dihydroartemisinin (DHA) in plasma. ARTS and DHA in plasma samples from patients treated with ARTS were quantified by HPLC and expressed as DHA. DHA-equivalents in the same plasma samples were measured using a standardised parasite culture technique. DHA concentrations estimated by both methods were highly correlated (bioassay = 0.96 x HPLC + 11.0; r(2) = 0.92). At high concentrations ( > 12 000 nmol/l) bioassay sometimes overestimated DHA. Bioassay of active drug in plasma correlates well with specific chemical analysis by HPLC. ARTS and DHA appear to account for the total antimalarial activity in plasma after ARTS administration. (C) 2003 Elsevier Science B.V. All rights reserved.