990 resultados para Coeficiente simple matching


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to investigate human contrast perception at various contrast levels ranging from detection threshold to suprathreshold levels by using psychophysical techniques. The work consists of two major parts. The first part deals with contrast matching, and the second part deals with contrast discrimination. Contrast matching technique was used to determine when the perceived contrasts of different stimuli were equal. The effects of spatial frequency, stimulus area, image complexity and chromatic contrast on contrast detection thresholds and matches were studied. These factors influenced detection thresholds and perceived contrast at low contrast levels. However, at suprathreshold contrast levels perceived contrast became directly proportional to the physical contrast of the stimulus and almost independent of factors affecting detection thresholds. Contrast discrimination was studied by measuring contrast increment thresholds which indicate the smallest detectable contrast difference. The effects of stimulus area, external spatial image noise and retinal illuminance were studied. The above factors affected contrast detection thresholds and increment thresholds measured at low contrast levels. At high contrast levels, contrast increment thresholds became very similar so that the effect of these factors decreased. Human contrast perception was modelled by regarding the visual system as a simple image processing system. A visual signal is first low-pass filtered by the ocular optics. This is followed by spatial high-pass filtering by the neural visual pathways, and addition of internal neural noise. Detection is mediated by a local matched filter which is a weighted replica of the stimulus whose sampling efficiency decreases with increasing stimulus area and complexity. According to the model, the signals to be compared in a contrast matching task are first transferred through the early image processing stages mentioned above. Then they are filtered by a restoring transfer function which compensates for the low-level filtering and limited spatial integration at high contrast levels. Perceived contrasts of the stimuli are equal when the restored responses to the stimuli are equal. According to the model, the signals to be discriminated in a contrast discrimination task first go through the early image processing stages, after which signal dependent noise is added to the matched filter responses. The decision made by the human brain is based on the comparison between the responses of the matched filters to the stimuli, and the accuracy of the decision is limited by pre- and post-filter noises. The model for human contrast perception could accurately describe the results of contrast matching and discrimination in various conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article presents applications of reconfigurable matching networks for RF amplifier design. Two possible solutions are given, one where the switching element is a PIN diode, and the other is based on graphene. Due to the fact that its conductivity depends on applied bias voltage, the graphene-based circuits can be used in microwave circuits as controllable elements. The structure of the proposed switch is very simple and it is particularly convenient for microstrip-based circuits. Because of that, a design of reconfigurable amplifier with the graphene-based switch is presented together with the one which has the PIN diode switch. Both amplifiers have the same specifications, and the one with the PIN diode switch is fabricated. The amplifier utilizing the PIN switch was used as a reference to make a comparison the two types of switches. Results of both amplifiers are very similar which indicates possible future applications of the graphene-based switch.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first objective of this research was to develop closed-form and numerical probabilistic methods of analysis that can be applied to otherwise conventional methods of unreinforced and geosynthetic reinforced slopes and walls. These probabilistic methods explicitly include random variability of soil and reinforcement, spatial variability of the soil, and cross-correlation between soil input parameters on probability of failure. The quantitative impact of simultaneously considering the influence of random and/or spatial variability in soil properties in combination with cross-correlation in soil properties is investigated for the first time in the research literature. Depending on the magnitude of these statistical descriptors, margins of safety based on conventional notions of safety may be very different from margins of safety expressed in terms of probability of failure (or reliability index). The thesis work also shows that intuitive notions of margin of safety using conventional factor of safety and probability of failure can be brought into alignment when cross-correlation between soil properties is considered in a rigorous manner. The second objective of this thesis work was to develop a general closed-form solution to compute the true probability of failure (or reliability index) of a simple linear limit state function with one load term and one resistance term expressed first in general probabilistic terms and then migrated to a LRFD format for the purpose of LRFD calibration. The formulation considers contributions to probability of failure due to model type, uncertainty in bias values, bias dependencies, uncertainty in estimates of nominal values for correlated and uncorrelated load and resistance terms, and average margin of safety expressed as the operational factor of safety (OFS). Bias is defined as the ratio of measured to predicted value. Parametric analyses were carried out to show that ignoring possible correlations between random variables can lead to conservative (safe) values of resistance factor in some cases and in other cases to non-conservative (unsafe) values. Example LRFD calibrations were carried out using different load and resistance models for the pullout internal stability limit state of steel strip and geosynthetic reinforced soil walls together with matching bias data reported in the literature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pennsylvania Adoption Exchange (PAE) helps case workers who represent children in state custody by recommending prospective families for adoption. We describe PAE's operational challenges using case worker surveys and analyze child outcomes through a regression analysis of data collected over multiple years. A match recommendation spreadsheet tool implemented by PAE incorporates insights from this analysis and allows PAE managers to better utilize available information. Using a discrete-event simulation of PAE, we justify the value of a statewide adoption network and demonstrate the importance of better information about family preferences for increasing the percentage of children who are successfully adopted. Finally, we detail a series of simple improvements that PAE achieved through collecting more valuable information and aligning incentives for families to provide useful preference information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivo: Conocer la opinión de los profesionales de enfermería sobre la utilidad del registro y valoración del dolor agudo como quinta constante clínica; así como, determinar la correlación de la escala visual analógica (EVA) con la verbal simple (EVS) y la verbal numérica (EVN). Material y métodos: Estudio observacional descriptivo. Cuestionario de opinión "ad hoc" y correlación lineal entre escalas. Análisis estadístico descriptivo e inferencial mediante el coeficiente de correlación intraclase y el método de Bland-Altman. Resultados: muestra de 102 profesionales (58% mujeres). El 90,2% cree importante que se mida el dolor agudo; el 65,7% ven la escala EVA poco práctica; el 80,4% no sabe cuándo se debe reevaluar el dolor (p<0,05). La concordancia entre escalas fue baja-moderada, siendo la EVN la mejor alternativa a la EVA. Conclusiones: el procedimiento de registro y medición del dolor fue muy bien valorado por los profesionales, pero su implementación presentó baja adherencia. La concordancia obtenida no fue significativa para sustituir con garantías a la EVA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnoloigia, 2016.

Relevância:

20.00% 20.00%

Publicador: