562 resultados para Cathodic pretreatments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon dioxide electroreduction on copper electrode was studied by surface enhanced Raman scattering (SERS) in K(2)SO(4) aqueous solutions with different pH values. CO(2) was bubbled into the solution at 0 V vs. Ag/AgCl, i.e., on an oxidized copper surface. In acidic solutions (pH around 2.5), at -0.2 V, bands indicative of the presence of ethylene on the electrode surface were detected. Although ethylene is knowledgably a product of CO(2) electroreduction on copper, it was not experimentally identified on the electrode`s surface at such a low cathodic potential in prior works. In solutions with pH around 2.5, CO bands were not observed, suggesting that hydrocarbons could be formed by a pathway that does not occur via adsorbed CO. In solutions with higher pHs, a complex spectral pattern, between 800 and 1700 cm(-1), was observed at approximately -0.4 V. The observed spectrum closely resembles those reported in the literature for adsorption of monocarboxylic acids with small chains. The spectral features indicate the presence of a structure containing a double C=C bond. a carboxyl group, and C-H bonds on the electrode`s surface. SERS spectra obtained in CO-saturated solution are also presented. However, in this case, no SERS bands were observed in the region between 800 and 1700 cm(-1) at low cathodic potentials. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and evaluation of a sequential injection method to automate the determination of methyl parathion by square wave adsorptive cathodic stripping voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. Accumulation and stripping steps are made in the sample medium conditioned with 40 mmol L-1 Britton-Robinson buffer (pH 10) in 0.25 mol L-1 NaNO3. The homogenized mixture is injected at a flow rate of 10 mu Ls(-1) toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode. After a suitable deposition time, the flow is stopped and the potential is scanned from -0.3 to -1.0 V versus Ag/AgCl at frequency of 250 Hz and pulse height of 25 mV The linear dynamic range is observed for methyl parathion concentrations between 0.010 and 0.50 mgL(-1), with detection and quantification limits of 2 and 7 mu gL(-1), respectively. The sampling throughput is 25 h(-1) if the in line standard addition and sample conditioning protocols are followed, but this frequency can be increased up to 61 h(-1) if the sample is conditioned off-line and quantified using an external calibration curve. The method was applied for determination of methyl parathion in spiked water samples and the accuracy was evaluated either by comparison to high performance liquid chromatography with UV detection, or by the recovery percentages. Although no evidences of statistically significant differences were observed between the expected and obtained concentrations, because of the susceptibility of the method to interference by other pesticides (e.g., parathion, dichlorvos) and natural organic matter (e.g., fulvic and humic acids), isolation of the analyte may be required when more complex sample matrices are encountered. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical vapour deposition (PVD) titanium aluminium nitride coated cutting tools are used extensively in global manufacturing for reducing production costs and improving productivity in a number of aggressive metal-cutting operations, namely, dry and high-speed machining. In this investigation, the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coatings was assessed on Co-HSS twist drills used to machine grey cast iron. The failure criterion for drills was defined as a critical sized flank wear land at the outer corners of the drills. Using this criterion, the average tool life of uncoated twist drills was increased by factors of 2.5, 3.0 and 3.0 by Ti0.59Al0.41N, Ti0.27Al0.19Cr0.54N and Ti0.21Al0.14Cr0.65N coatings, respectively. Notwithstanding the similar increase in average tool life, the Ti1−x−yAlxCryN coatings produced more consistent results than the Ti1−xAlxN coated drills with standard deviations of 67, 3 and 19 holes, respectively. This result has significant practical implications in manufacturing, since drills are not replaced on an individual basis, but rather on a preset tool change frequency. The present paper discusses the performance of Ti1−xAlxN and Ti1−x−yAlxCryN coated drills in terms of average and practical drill life and concludes with remarks on the characterisation of PVD coatings and their significance on the performance of Co-HSS twist drills when dry machining grey cast iron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cathodic arc evaporation (CAE) is a widely used technique for generating highly ionised plasma from which hard, wear-resistant PVD coatings can be deposited. A major drawback of this technique is the emission of micrometer-sized droplets of cathode material from the arc spot, which are commonly referred to as ‘macroparticles’. In this study, the effect of cathode poisoning was investigated as a method to reduce the number of macroparticles in PVD coatings. While the study focuses on the reduction of macroparticles in titanium nitride coatings, the outcomes and key findings can be broadly applied to the cathodic arc process, in particular, for the reduction of macroparticles in more advanced CAE coatings. The results support earlier findings that have shown that poisoning of the cathode can reduce the number of macroparticles emitted from the arc spot. The results of glow discharge optical emission spectroscopy (GD-OES) showed that the titanium content of the coatings varied little between the respective coatings despite changes in the deposition pressure from 0.1 to 1.2 Pa. The GD-OES results also showed the presence of oxide contamination at the surface of the coatings, which was significantly reduced with increasing deposition pressure. The coatings were also deposited onto high-speed steel twist drills to compare the metal-cutting performance when dry drilling a workpiece of cast iron. The results of the drill tests showed that tool life increased with a reduction in the number of macroparticles.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cathodic disbondment (CD) performance of a range of modified polyethylenes (PE) compression molded on to steel plates at 320[degrees]C is reported. Adhesion strength was measured by the 90[degrees] peel test and good dry adhesion strength was obtained for all modified polyethylene materials and blends, as well as for the neat polymer. It is shown that dry bond strength does not correlate with CD performance. Initial results of wet peel tests of samples in various concentrations of NaOH are presented where it is observed that for samples with improved wet adhesion strength, CD performance was also Improved. Surface polarity was determined from contact angle measurements, and it is shown that increased surface polarity of the coating was not the only determinant for improved CD performance. Inorganic fillers such as talc were also found to improve CD performance by changing the bulk properties, with little measurable change in polarity. Some mechanistic aspects of CD performance are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of blending two different materials with a medium density polyethylene for use as pipe coatings is presented. The influence of such blending on properties such as cathodic disbondment (CD) and wet adhesion on steel is investigated. The components blended include a functionalised polyethylene (PE) containing the polar functionality, maleic anhydride (MAH) and an amorphous elastomer, ethylene-propylene-diene terpolymer (EPDM). It was found that modification of PE with small amount (2.5–3 wt%) of either blended MAH-g-PE or EPDM resulted in a significant improvement in CD performance and wet adhesion strength. The mode of failure and disbondment mechanism was investigated using energy dispersive X-ray spectroscopy (EDXS) and X-ray photoelectron spectroscopy (XPS). The greater resistance of migration of sodium ions increases with the incorporation of the modifiers, and it is proposed that this results in an increase in CD performance.