875 resultados para Capitation of images


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a method for indirect orientation of aerial images using ground control lines extracted from airborne Laser system (ALS) data. This data integration strategy has shown good potential in the automation of photogrammetric tasks, including the indirect orientation of images. The most important characteristic of the proposed approach is that the exterior orientation parameters (EOP) of a single or multiple images can be automatically computed with a space resection procedure from data derived from different sensors. The suggested method works as follows. Firstly, the straight lines are automatically extracted in the digital aerial image (s) and in the intensity image derived from an ALS data-set (S). Then, correspondence between s and S is automatically determined. A line-based coplanarity model that establishes the relationship between straight lines in the object and in the image space is used to estimate the EOP with the iterated extended Kalman filtering (IEKF). Implementation and testing of the method have employed data from different sensors. Experiments were conducted to assess the proposed method and the results obtained showed that the estimation of the EOP is function of ALS positional accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reservoirs are artificial environments built by humans, and the impacts of these environments are not completely known. Retention time and high nutrient availability in the water increases the eutrophic level. Eutrophication is directly correlated to primary productivity by phytoplankton. These organisms have an important role in the environment. However, high concentrations of determined species can lead to public health problems. Species of cyanobacteria produce toxins that in determined concentrations can cause serious diseases in the liver and nervous system, which could lead to death. Phytoplankton has photoactive pigments that can be used to identify these toxins. Thus, remote sensing data is a viable alternative for mapping these pigments, and consequently, the trophic. Chlorophyll-a (Chl-a) is present in all phytoplankton species. Therefore, the aim of this work was to evaluate the performance of images of the sensor Operational Land Imager (OLI) onboard the Landsat-8 satellite in determining Chl-a concentrations and estimating the trophic level in a tropical reservoir. Empirical models were fitted using data from two field surveys conducted in May and October 2014 (Austral Autumn and Austral Spring, respectively). Models were applied in a temporal series of OLI images from May 2013 to October 2014. The estimated Chl-a concentration was used to classify the trophic level from a trophic state index that adopted the concentration of this pigment-like parameter. The models of Chl-a concentration showed reasonable results, but their performance was likely impaired by the atmospheric correction. Consequently, the trophic level classification also did not obtain better results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the diagnostic quality of first-trimester ultrasound images transmitted in realtime using low-cost telecommunications. A prospective sample of fetal ultrasound images from 11 weeks to 13 weeks and six days of pregnancy was obtained from pregnant women over 18 years old. The examinations were transmitted in realtime to three independent examiners who carried out a qualitative assessment based on parameters established by the Fetal Medicine Foundation. All fetal structures could be viewed and the quality of images received by the examiners was considered normal. There were significant differences for crown-rump length and nuchal translucency in the transmitted images but the loss in definition was acceptable. Thus the quality of images transmitted via the Internet through the use of low-cost software appeared suitable for screening for chromosomal abnormalities in the first trimester of pregnancy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies of subjective time have adopted different methods to understand different processes of time perception. Four sculptures, with implied movement ranked as 1.5-, 3.0-, 4.5-, and 6.0-point stimuli on the Body Movement Ranking Scale, were randomly presented to 42 university students untrained in visual arts and ballet. Participants were allowed to observe the images for any length of time (exploration time) and, immediately after each image was observed, recorded the duration as they perceived it. The results of temporal ratio (exploration time/time estimation) showed that exploration time of images also affected perception of time, i.e., the subjective time for sculptures representing implied movement were overestimated.\

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] We discuss the processing of data recorded with multimonochromatic x-ray imagers (MMI) in inertial confinement fusion experiments. The MMI records hundreds of gated, spectrally resolved images that can be used to unravel the spatial structure of the implosion core. In particular, we present a new method to determine the centers in all the array of images, a better reconstruction technique of narrowband implosion core images, two algorithms to determine the shape and size of the implosion core volume based on reconstructed broadband images recorded along three-quasiorthogonal lines of sight, and the removal of artifacts from the space-integrated spectra.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[EN] In this paper we present a method for the regularization of a set of unstructured 3D points obtained from a sequence of stereo images. This method takes into account the information supplied by the disparity maps computed between pairs of images to constraint the regularization of the set of 3D points. We propose a model based on an energy which is composed of two terms: an attachment term that minimizes the distance from 3D points to the projective lines of camera points, and a second term that allows for the regularization of the set of 3D points by preserving discontinuities presented on the disparity maps. We embed this energy in a 2D finite element method. After minimizing, this method results in a large system of equations that can be optimized for fast computations. We derive an efficient implicit numerical scheme which reduces the number of calculations and memory allocations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A two-pronged approach for the automatic quantitation of multiple sclerosis (MS) lesions on magnetic resonance (MR) images has been developed. This method includes the design and use of a pulse sequence for improved lesion-to-tissue contrast (LTC) and seeks to identify and minimize the sources of false lesion classifications in segmented images. The new pulse sequence, referred to as AFFIRMATIVE (Attenuation of Fluid by Fast Inversion Recovery with MAgnetization Transfer Imaging with Variable Echoes), improves the LTC, relative to spin-echo images, by combining Fluid-Attenuated Inversion Recovery (FLAIR) and Magnetization Transfer Contrast (MTC). In addition to acquiring fast FLAIR/MTC images, the AFFIRMATIVE sequence simultaneously acquires fast spin-echo (FSE) images for spatial registration of images, which is necessary for accurate lesion quantitation. Flow has been found to be a primary source of false lesion classifications. Therefore, an imaging protocol and reconstruction methods are developed to generate "flow images" which depict both coherent (vascular) and incoherent (CSF) flow. An automatic technique is designed for the removal of extra-meningeal tissues, since these are known to be sources of false lesion classifications. A retrospective, three-dimensional (3D) registration algorithm is implemented to correct for patient movement which may have occurred between AFFIRMATIVE and flow imaging scans. Following application of these pre-processing steps, images are segmented into white matter, gray matter, cerebrospinal fluid, and MS lesions based on AFFIRMATIVE and flow images using an automatic algorithm. All algorithms are seamlessly integrated into a single MR image analysis software package. Lesion quantitation has been performed on images from 15 patient volunteers. The total processing time is less than two hours per patient on a SPARCstation 20. The automated nature of this approach should provide an objective means of monitoring the progression, stabilization, and/or regression of MS lesions in large-scale, multi-center clinical trials. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ZooScan with ZooProcess and Plankton Identifier (PkID) software is an integrated analysis system for acquisition and classification of digital zooplankton images from preserved zooplankton samples. Zooplankton samples are digitized by the ZooScan and processed by ZooProcess and PkID in order to detect, enumerate, measure and classify the digitized objects. Here we present a semi-automatic approach that entails automated classification of images followed by manual validation, which allows rapid and accurate classification of zooplankton and abiotic objects. We demonstrate this approach with a biweekly zooplankton time series from the Bay of Villefranche-sur-mer, France. The classification approach proposed here provides a practical compromise between a fully automatic method with varying degrees of bias and a manual but accurate classification of zooplankton. We also evaluate the appropriate number of images to include in digital learning sets and compare the accuracy of six classification algorithms. We evaluate the accuracy of the ZooScan for automated measurements of body size and present relationships between machine measures of size and C and N content of selected zooplankton taxa. We demonstrate that the ZooScan system can produce useful measures of zooplankton abundance, biomass and size spectra, for a variety of ecological studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A semi-automatic segmentation algorithm for abdominal aortic aneurysms (AAA), and based on Active Shape Models (ASM) and texture models, is presented in this work. The texture information is provided by a set of four 3D magnetic resonance (MR) images, composed of axial slices of the abdomen, where lumen, wall and intraluminal thrombus (ILT) are visible. Due to the reduced number of images in the MRI training set, an ASM and a custom texture model based on border intensity statistics are constructed. For the same reason the shape is characterized from 35-computed tomography angiography (CTA) images set so the shape variations are better represented. For the evaluation, leave-one-out experiments have been held over the four MRI set.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physician training has greatly benefitted from insights gained in understanding the manner in which experts search medical images for abnormalities. The aims of this study were to compare the search patterns of 30 fourth-year dental students and 15 certified oral and maxillofacial radiologists (OMRs) over panoramic images and to determine the most robust variables for future studies involving image visualization. Eye tracking was used to capture the eye movement patterns of both subject groups when examining 20 panoramic images classified as normal or abnormal. Abnormal images were further subclassified as having an obvious, intermediate, or subtle abnormality. The images were presented in random order to each participant, and data were collected on duration of the participants’ observations and total distance tracked, time to first eye fixation, and total duration and numbers of fixations on and off the area of interest (AOI). The results showed that the OMRs covered greater distances than the dental students (p<0.001) for normal images. For images of pathosis, the OMRs required less total time (p<0.001), made fewer eye fixations (p<0.01) with fewer saccades (p<0.001) than the students, and required less time before making the first fixation on the AOI (p<0.01). Furthermore, the OMRs covered less distance (p<0.001) than the dental students for obvious pathoses. For investigations of images of pathosis, time to first fixation is a robust parameter in predicting ability. For images with different levels of subtlety of pathoses, the number of fixations, total time spent, and numbers of revisits are important parameters to analyze when comparing observer groups with different levels of experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Physician training has greatly benefitted from insights gained in understanding the manner in which experts search medical images for abnormalities. The aims of this study were to compare the search patterns of 30 fourth-year dental students and 15 certified oral and maxillofacial radiologists (OMRs) over panoramic images and to determine the most robust variables for future studies involving image visualization. Eye tracking was used to capture the eye movement patterns of both subject groups when examining 20 panoramic images classified as normal or abnormal. Abnormal images were further subclassified as having an obvious, intermediate, or subtle abnormality. The images were presented in random order to each participant, and data were collected on duration of the participants’ observations and total distance tracked, time to first eye fixation, and total duration and numbers of fixations on and off the area of interest (AOI). The results showed that the OMRs covered greater distances than the dental students (p<0.001) for normal images. For images of pathosis, the OMRs required less total time (p<0.001), made fewer eye fixations (p<0.01) with fewer saccades (p<0.001) than the students, and required less time before making the first fixation on the AOI (p<0.01). Furthermore, the OMRs covered less distance (p<0.001) than the dental students for obvious pathoses. For investigations of images of pathosis, time to first fixation is a robust parameter in predicting ability. For images with different levels of subtlety of pathoses, the number of fixations, total time spent, and numbers of revisits are important parameters to analyze when comparing observer groups with different levels of experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Little is known about the quality of the images transmitted in email telemedicine systems. The present study was designed to survey the quality of images transmitted in the Swinfen Charitable Trust email referral system. Telemedicine cases were examined for a 3 month period in 2002 and a 3 month period in 2006. The number of cases with images attached increased from 8 (38%) to 37 (53%). There were four types of images (clinical photographs, microscope pictures, notes and X-ray images) and the proportion of radiology images increased from 27 to 48%. The cases in 2002 came from four different hospitals and were associated with seven different clinical specialties. In 2006, the cases came from 19 different hospitals and 20 different specialties. The 46 cases (from both study periods) had a total of 159 attached images. The quality of the images was assessed by awarding each image a score in four categories: focus, anatomical perspective, composition and lighting. The images were scored on a five-point scale (1 = very poor to 5 =very good) by a qualified medical photographer. In comparing image quality between the two study periods, there was some evidence that the quality had reduced, although the average size of the attached images had increased. The median score for all images in 2002 was 16 (interquartile range 14-19) and the median score in 2006 was 15 (13-16). The difference was significant (P < 0.001, Mann-Whitney test).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number of remote sensing platforms and sensors rises almost every year, yet much work on the interpretation of land cover is still carried out using either single images or images from the same source taken at different dates. Two questions could be asked of this proliferation of images: can the information contained in different scenes be used to improve the classification accuracy and, what is the best way to combine the different imagery? Two of these multiple image sources are MODIS on the Terra platform and ETM+ on board Landsat7, which are suitably complementary. Daily MODIS images with 36 spectral bands in 250-1000 m spatial resolution and seven spectral bands of ETM+ with 30m and 16 days spatial and temporal resolution respectively are available. In the UK, cloud cover may mean that only a few ETM+ scenes may be available for any particular year and these may not be at the time of year of most interest. The MODIS data may provide information on land cover over the growing season, such as harvest dates, that is not present in the ETM+ data. Therefore, the primary objective of this work is to develop a methodology for the integration of medium spatial resolution Landsat ETM+ image, with multi-temporal, multi-spectral, low-resolution MODIS \Terra images, with the aim of improving the classification of agricultural land. Additionally other data may also be incorporated such as field boundaries from existing maps. When classifying agricultural land cover of the type seen in the UK, where crops are largely sown in homogenous fields with clear and often mapped boundaries, the classification is greatly improved using the mapped polygons and utilising the classification of the polygon as a whole as an apriori probability in classifying each individual pixel using a Bayesian approach. When dealing with multiple images from different platforms and dates it is highly unlikely that the pixels will be exactly co-registered and these pixels will contain a mixture of different real world land covers. Similarly the different atmospheric conditions prevailing during the different days will mean that the same emission from the ground will give rise to different sensor reception. Therefore, a method is presented with a model of the instantaneous field of view and atmospheric effects to enable different remote sensed data sources to be integrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sparse representation of astronomical images is discussed. It is shown that a significant gain in sparsity is achieved when particular mixed dictionaries are used for approximating these types of images with greedy selection strategies. Experiments are conducted to confirm (i) the effectiveness at producing sparse representations and (ii) competitiveness, with respect to the time required to process large images. The latter is a consequence of the suitability of the proposed dictionaries for approximating images in partitions of small blocks. This feature makes it possible to apply the effective greedy selection technique called orthogonal matching pursuit, up to some block size. For blocks exceeding that size, a refinement of the original matching pursuit approach is considered. The resulting method is termed "self-projected matching pursuit," because it is shown to be effective for implementing, via matching pursuit itself, the optional backprojection intermediate steps in that approach. © 2013 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Medical imaging technologies are experiencing a growth in terms of usage and image resolution, namely in diagnostics systems that require a large set of images, like CT or MRI. Furthermore, legal restrictions impose that these scans must be archived for several years. These facts led to the increase of storage costs in medical image databases and institutions. Thus, a demand for more efficient compression tools, used for archiving and communication, is arising. Currently, the DICOM standard, that makes recommendations for medical communications and imaging compression, recommends lossless encoders such as JPEG, RLE, JPEG-LS and JPEG2000. However, none of these encoders include inter-slice prediction in their algorithms. This dissertation presents the research work on medical image compression, using the MRP encoder. MRP is one of the most efficient lossless image compression algorithm. Several processing techniques are proposed to adapt the input medical images to the encoder characteristics. Two of these techniques, namely changing the alignment of slices for compression and a pixel-wise difference predictor, increased the compression efficiency of MRP, by up to 27.9%. Inter-slice prediction support was also added to MRP, using uni and bi-directional techniques. Also, the pixel-wise difference predictor was added to the algorithm. Overall, the compression efficiency of MRP was improved by 46.1%. Thus, these techniques allow for compression ratio savings of 57.1%, compared to DICOM encoders, and 33.2%, compared to HEVC RExt Random Access. This makes MRP the most efficient of the encoders under study.