993 resultados para Capacitance meters.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relation between the input impedance and the characteristic parameters of a cavity, such as the resonance frequency, shunt impedance and. the quality factor, has been obtained based on the equivalent circuit of the cavity and the coupling system. Using the matching condition, the ratio of coupling capacitance to the equivalent capacitance of the cavity can be acquired as a function of the characteristic parameters of the cavity, the value of the coupling capacitance can be obtained with a help of a numerical simulation and the perturbation theory, and then the perfect matching between the cavity and the transmission line can be procured. The application of these results on a model cavity is presented too.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is developed to estimate the coverage of an electropolymerizable aniline-analogue monolayer (mixture of 2- and 3-aminophenols, 2/3-ATP) by measuring the charge capacitance of the electrode (theta = 81%). The technique of filling the uncovered area (defect sites) of the aniline-analogue monolayer with alkanethiols with long alkane chains (1-decanethiol, 1-DT) has been used to determine the coverage. The dielectric constant (permittivity) of the PANI-analogue monolayer was determined to 8.4. Adsorption kinetics of 1-DT was also studied, and the value of the rate constant of the secondary adsorption was measured to 0.9 mol(-1) dm(3) s(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monolayer protected gold nanoparticles (MPCs) are the focus of recent research for their stability and are deemed as the building blocks of bottom-up strategies. In this Letter, 3-mercapto-1,2-propanediol monolayer protected gold nanoparticles (MPD-MPCs) were synthesized and characterized by transmission electron microscopy, UV/Vis spectroscopy, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The value of quantized double-layer capacitance (1.13 aF) of MPD-MPCs in aqueous media was obtained by differential pulse voltammograms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3-Mercaptopropionic add monolayer protected gold nanoclusters (MPA-MPCs) were synthesized and characterized by transmission electron microscopy, UV-Vis spectroscopy, X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. The exact value of quantized double-layer capacitance of MPCS in aqueous media was obtained by differential pulse voltammograms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CTAB-stabilized silver nanoparticles were synthesized by NaBH4 reduction. The as-prepared nanoparticles can be self-assembled on 3-mercaptopropionic acid (MPA) modified gold electrode, which was supported strongly by XPS measurements. Exceptional long-term stability of the as-prepared colloidal silver aqueous solution and the desorption of silver nanoparticle ensemble on MPA after alcohol rinsing proved that these CTAB molecules adsorbed on silver core formed interdigitated bilayer structure. DPV and differential capacitance measurements were performed to characterize the as-prepared silver nanoparticle ensemble. and the interesting quantized capacitance charging behaviors were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid-base equilibrium of self-assembly monolayer(SAM) of mercaptopropionic acid on gold electrode was studied by capacitance titration. The change of capacitance was due to protonation and deprotonation of the modified electrode surface. This method can be used to measure pH value in solution and capacitance of solid/liquid on SAMs surface synchronously. The shift of pK(a) was observed during the experiment as previous reports. The factors that affect the capacitance measurement were discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The principle and technique of double layer capacitance and its application in electrochemical biosensor are briefly reviewed with 50 references. The future development of double layer capacitance biosensor is expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel type of potassium sensor based on the capacitance change of valinomycin-incorporated bilayer supported on a gold electrode has been developed and characterized. The lipid membrane was Formed by painted method and monitored simultaneously by capacitance variation. The capacitance of the electrode-supported membrane was found to be modulated by different concentrations of K+. Investigating the capacitance change allows a simple and specific technique for the measurement of potassium ion in solution. Especially, the homemade capacitance meter is, to our knowledge, used to monitor the bilayer membrane formation and detect K+ for the first time. It has been proved that this capacitance measurement is a very useful technique because it is simple and sensitive compared to the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a new theoretical model based on the MPB4 theory to calculate the differential capacitance of the interface of 0.05mol/L MgSO4 in water and 0.1mol/L TBATPB in nitrobenzene. Our results coincide with the experimental values very well. It indicates that our model may describe well the structure of ITIES not only in the presence of 1:1 electrolyte but also in the presence of 2:2 electrolyte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The MPB4 theory is used to calculate the differential capacitance of the interface between LiCl in water and TBATPB in 1,2-dichloroethane at electrolyte concentrations of 0.005, 0.01 and 0.02 M. The effects of the ion size and the image force, and the influence of the electrolyte concentration, the surface charge density and the solvent effect on the inner layer potential drop are considered simultaneously. These effects can be ascribed to the ionic penetration into the opposite solution and ion-ion correlations across the interface. Our results are in better agreement with experimental data than those obtained using Gouy-Chapman theory. This indicates that the MPB4 theory may also describe the structure of the water \1,2-dichloroethane interface provided that the influence of the electrolyte concentration, the surface charge density and the solvent effect on the inner layer potential distribution are included in the calculation. Comparison of the theoretical results with those of the water \nitrobenzene interface shows that the structure of the water \1,2-dichloroethane interface is similar to that of the water \nitrobenzene interface, except that in the former case the inner-layer potential drop is much higher and the effects of the image force and the ion size are more pronounced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the MPB4 theory to calculate the differential capacitance of the interface between NaBr + water and tetrabutylammoniumtetraphenyl borate (TBATPB) + nitrobenzene at electrolyte concentrations of 0.01 M, 0.02 M and 0.05 M. In addition to the effects

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the embedded capacitance material (ECM) is fabricated between the power and ground layers of the wireless sensor nodes, forming an integrated capacitance to replace the large amount of decoupling capacitors on the board. The ECM material, whose dielectric constant is 16, has the same size of the wireless sensor nodes of 3cm*3cm, with a thickness of only 14μm. Though the capacitance of a single ECM layer being only around 8nF, there are two reasons the ECM layers can still replace the high frequency decoupling capacitors (100nF in our case) on the board. The first reason is: the parasitic inductance of the ECM layer is much lower than the surface mount capacitors'. A smaller capacitance value of the ECM layer could achieve the same resonant frequency of the surface mount decoupling capacitors. Simulation and measurement fit this assumption well. The second reason is: more than one layer of ECM material are utilized during the design step to get a parallel connection of the several ECM capacitance layers, finally leading to a larger value of the capacitance and smaller value of parasitic. Characterization of the ECM is carried out by the LCR meter. To evaluate the behaviors of the ECM layer, time and frequency domain measurements are performed on the power-bus decoupling of the wireless sensor nodes. Comparison with the measurements of bare PCB board and decoupling capacitors solution are provided to show the improvement of the ECM layer. Measurements show that the implementation of the ECM layer can not only save the space of the surface mount decoupling capacitors, but also provide better power-bus decoupling to the nodes.