964 resultados para CAMERA-TRAP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating for camera saturation which takes into account the variable activity in the field of view, i.e. time-dependent dead-time effects. The algorithm presented here accomplishes this task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, the development of new tools to gather field information about vector ecological parameters has increased. This report evaluated the BG-Sentinel Trap (BGS-Trap), a promising new attempt to improve collection of the dengue vector, Aedes aegypti. The efficacy of the BGS-Trap was compared with the CDC backpack aspirator, one of the commonest used methods for capturing adult mosquitoes. BGS-Traps captured significantly more Ae. aegypti males (chi2 = 21.774, df = 1, P < 0.05) and females (chi2 = 56.007, df = 1, P < 0.05) than CDC aspirator during all days of field collection. However, CDC aspirator was significantly more efficient to capture Culex quinquefasciatus males (chi2 = 5.681, df = 1, P < 0.05) and females (chi2 = 6.553, df = 1, P < 0.05). BGS-Traps captured host-seeking females (varying between 68.75 to 89.8%) in detriment of females in other behavioral and physiological stages. BGS-Traps proved to be efficient and can be used for monitoring adult mosquito populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ovitrap (BR-OVT) based on physical and chemical stimuli for attracting gravid Culex quinquefasciatus (Diptera: Culicidae) females was developed and evaluated under laboratory and field conditions. Attractants were assayed using alternative chamber bioassays prior to being used in the BR-OVT oviposition trap. A significant preference of gravid females for sites containing conspecific egg rafts was observed, as a response to the natural oviposition pheromone, as well as for sites treated with the synthetic pheromone erythro-6-acetoxy-5-hexadecanolide. Five- to 20-day old grass infusion was strongly attractive to gravid females for laying eggs. On the other hand, entomopathogenic Bacillus sphaericus (Bs) did not influence the choice of an oviposition site when used in combination with grass infusion and can therefore be used as a larvicide in ovitraps. Results from field trials showed that the BR-OVT with grass infusion and with or without Bs works as a preferred oviposition site for Cx. quinquefasciatus. The BR-OVT was more effective for egg collection when placed indoors and comparison with the number of egg rafts laid in cesspits over 40 days indicates that this very simple ovitrap may be a useful tool for monitoring populations of the most important of the vectors of bancroftian filariasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the modifications made to the original model of the Disney trap, with a view to easier handling of the same, greater practicability in the collection of sand flies, protection of the animal bait and durability of the trap in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positioning a robot with respect to objects by using data provided by a camera is a well known technique called visual servoing. In order to perform a task, the object must exhibit visual features which can be extracted from different points of view. Then, visual servoing is object-dependent as it depends on the object appearance. Therefore, performing the positioning task is not possible in presence of nontextured objets or objets for which extracting visual features is too complex or too costly. This paper proposes a solution to tackle this limitation inherent to the current visual servoing techniques. Our proposal is based on the coded structured light approach as a reliable and fast way to solve the correspondence problem. In this case, a coded light pattern is projected providing robust visual features independently of the object appearance

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three types of carbon dioxide-baited traps, i.e., the Centers for Disease Control Miniature Light Trap without light, the BioGents (BG) Sentinel Mosquito Trap (BG-Sentinel) and the Mosquito Magnet® Liberty Plus were compared with human landing collections in their efficiency in collecting Anopheles (Nyssorhynchus) aquasalis mosquitoes. Of 13,549 total mosquitoes collected, 1,019 (7.52%) were An. aquasalis. Large numbers of Culex spp were also collected, in particular with the (BG-Sentinel). The majority of An. aquasalis (83.8%) were collected by the human landing collection (HLC). None of the trap catches correlated with HLC in the number of An. aquasalis captured over time. The high efficiency of the HLC method indicates that this malaria vector was anthropophilic at this site, especially as carbon dioxide was insufficiently attractive as stand-alone bait. Traps using carbon dioxide in combination with human odorants may provide better results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the human-landing catch (HLC) method is the most effective for collecting anthropophilic anophelines, it has been increasingly abandoned, primarily for ethical considerations. The objective of the present study was to develop a new trap for the collection of Anopheles darlingi . The initial trials were conducted using the BG-Sentinel trap as a standard for further trap development based on colour, airflow direction and illumination. The performance of the trap was then compared with those of the CDC, Fay-Prince, counterflow geometry trap (CFG) and HLC. All trials were conducted outdoors between 06:00 pm-08:00 pm. Female specimens of An. darlingi were dissected to determine their parity. A total of 8,334 anophelines were captured, of which 4,945 were identified as An. darlingi . The best trap configuration was an all-white version, with an upward airflow and no required light source. This configuration was subsequently named BG-Malaria (BGM). The BGM captured significantly more anophelines than any of the other traps tested and was similar to HLC with respect to the number and parity of anophelines. The BGM trap can be used as an alternative to HLC for collecting anophelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distribution, abundance, feeding behaviour, host preference, parity status and human-biting and infection rates are among the medical entomological parameters evaluated when determining the vector capacity of mosquito species. To evaluate these parameters, mosquitoes must be collected using an appropriate method. Malaria is primarily transmitted by anthropophilic and synanthropic anophelines. Thus, collection methods must result in the identification of the anthropophilic species and efficiently evaluate the parameters involved in malaria transmission dynamics. Consequently, human landing catches would be the most appropriate method if not for their inherent risk. The choice of alternative anopheline collection methods, such as traps, must consider their effectiveness in reproducing the efficiency of human attraction. Collection methods lure mosquitoes by using a mixture of olfactory, visual and thermal cues. Here, we reviewed, classified and compared the efficiency of anopheline collection methods, with an emphasis on Neotropical anthropophilic species, especially Anopheles darlingi, in distinct malaria epidemiological conditions in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, sticky traps are regularly employed to assist in the surveillance of Aedes aegypti infestation. We tested two alternative procedures for specimen identification performed by local health agents: directly in the field, as recommended by certain manufacturers, or after transportation to the laboratory. A total of 384 sticky traps (MosquiTRAP) were monitored monthly during one year in four geographically representative Brazilian municipalities. When the same samples were inspected in the field and in the laboratory, large differences were noted in the total number of mosquitoes recorded and in the number of specimens identified as Ae. aegypti by both procedures. Although field identification has the potential to speed vector surveillance, these results point to uncertainties in the evaluated protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traps are widely employed for sampling and monitoring mosquito populations for surveillance, ecological and fauna studies. Considering the importance of assessing other technologies for sampling mosquitoes, we addressed the effectiveness of Mosquito Magnet® Independence (MMI) in comparison with those of the CDC trap with CO2 and Lurex3® (CDC-A) and the CDC light trap (CDC-LT). Field collections were performed in a rural area within the Atlantic Forest biome, southeastern state of São Paulo, Brazil. The MMI sampled 53.84% of the total number of mosquitoes, the CDC-A (26.43%) and CDC-LT (19.73%). Results of the Pearson chi-squared test (χ2) showed a positive association between CDC-LT and species of Culicini and Uranotaeniini tribes. Additionally, our results suggested a positive association between CDC-A and representatives of the Culicini and Aedini tribes, whereas the MMI was positively associated with the Mansoniini and Sabethini as well as with Anophelinae species. The MMI sampled a greater proportion (78.27%) of individuals of Anopheles than either the CDC-LT (0.82%) or the CDC-A traps (20.91%). Results of the present study showed that MMI performed better than CDC-LT or CDC-A in sampling mosquitoes in large numbers, medically important species and assessing diversity parameters in rural southeastern Atlantic Forest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A longitudinal study was conducted in Manaus, Brazil, to monitor changes of adult Aedes aegypti (L.) abundance. The objectives were to compare mosquito collections of two trap types, to characterise temporal changes of the mosquito population, to investigate the influence of meteorological variables on mosquito collections and to analyse the association between mosquito collections and dengue incidence. Mosquito monitoring was performed fortnightly using MosquiTRAPs (MQT) and BG-Sentinel (BGS) traps between December 2008-June 2010. The two traps revealed opposing temporal infestation patterns, with highest mosquito collections of MQTs during the dry season and highest collections of BGS during the rainy seasons. Several meteorological variables were significant predictors of mosquito collections in the BGS. The best predictor was the relative humidity, lagged two weeks (in a positive relationship). For MQT, only the number of rainy days in the previous week was significant (in a negative relationship). The correlation between monthly dengue incidence and mosquito abundance in BGS and MQT was moderately positive and negative, respectively. Catches of BGS traps reflected better the dynamic of dengue incidence. The findings help to understand the effects of meteorological variables on mosquito infestation indices of two different traps for adult dengue vectors in Manaus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.