989 resultados para Bone implants
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The aim of the present study was to evaluate histometric changes around dental implants inserted at different levels in relation to the crestal bone, under different loading conditions.Material and methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at the crestal bone level), Minus 1 (1 mm below the crestal bone) or Minus 2 group (2 mm below the crestal bone). Each hemimandible was submitted to a loading protocol: conventional or immediate restoration. After 90 days, the animals were killed. Specimens were processed, and measurements were performed concerning the length of soft and hard peri-implant tissues. Data were analyzed using ANOVA and Student's t test (alpha=5%).Results: Among conventionally restored sites, the distance from the most coronal position of soft tissue margin (PSTM) and first bone-implant contact (fBIC) was greater for Minus 2 than for Bone Level and Minus 1 sites (P=0.03), but significant differences were not observed among immediately restored sites. Differences among groups were not observed concerning the PSTM, and the distance from the implant-abutment junction to fBIC. Greater amounts of lateral bone loss were observed for conventionally than for immediately restored sites (P=0.006).Conclusions: These findings suggest that the apical positioning of the top of the implant may not jeopardize the position of soft peri-implant tissues, and that immediate restoration can be beneficial to minimize lateral bone loss. Further studies are suggested to evaluate the clinical significance of these results in longer healing periods.
Resumo:
Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)
Resumo:
A regeneração periodontal e do rebordo ósseo utilizando barreiras físicas são procedimentos bem estabelecidos em cirurgias reconstrutivas. As características do biomaterial e o desenho da membrana empregados na regeneração tecidual guiada desempenham um papel importante na obtenção de bons resultados. O objetivo deste estudo experimental histológico foi comparar o uso de dois tipos de barreiras físicas na regeneração óssea guiada em defeitos criados na tíbia de ratos. Quinze animais foram divididos em três grupos: grupo I (barreira não-porosa de politetrafluoretileno), grupo II (blocos de hidroxiapatita de coral) e grupo III (controle que não recebeu nenhuma barreira). A análise histológica demonstrou várias quantidades de osso neoformado com ambos os tipos de barreiras. A barreira de politetrafluoretileno mostrou melhores resultados do que a hidroxiapatita. Os resultados deste estudo sugerem que a regeneração óssea pode ser conseguida com a técnica de submersão da barreira física.
Resumo:
The aim of this study was to evaluate and compare the quantitative and qualitative inflammatory responses and bone formation potential after implantation of polyethylene tubes filled with a new calcium hydroxide containing sealer (MBPc) and Prolloot mineral trioxide aggregate (MIA). There were 48 Wistar rats divided in three groups: Group I (control group) empty polyethylene tubes were implanted in the extraction site; group II and III, polyethylene tubes were implanted filled with ProRoot mineral trioxide aggregate (MIA) and MBPc, respectively. At 7, 15, and 30 days after tube implantation, the animals were killed, the hemi-maxillas were removed and prepared to light microscopic analyses. The scores obtained were submitted to Kruskal-Wallis statistical test (p < 0.05). Significant differences between the materials were not observed. The results showed that both materials had similar biological response.
Resumo:
Background: Immunosuppressive agents may induce severe changes on bone metabolism and may impair the osseointegration process during the implant healing. No data are available concerning the influence of cyclosporin A on dental implants previously integrated to the bone. The aim of this study was to evaluate the influence of cyclosporin A administration on the mechanical retention of bone previously integrated to dental implants.Methods: Eighteen female New Zealand rabbits were submitted to an implant surgery. Each animal received one commercial dental implant of 10 x 3.75 mm. After 12 weeks of an undisturbed healing period, six animals were randomly sacrificed and the removal torque test was performed (group A). In addition, six animals were submitted to a daily injection of cyclosporin A in a dosage of 10 mg/kg (group C), and six animals received saline solution as a control (group B). After 12 weeks of cyclosporin A administration, groups B and C were sacrificed and submitted to a removal torque test in which higher values can be interpreted as higher mechanical bone retention to the implant surface or higher osseointegration.Results: the removal torque results were 30.5 (+/- 9.8) Ncm for group A, 50.17 (+/- 17.5) Ncm for group B, and 26 (+/- 7.8) Ncm for group C. The statistical analysis showed significant differences between groups A and B (P < 0.05) and groups B and C (P < 0.01).Conclusion: Cyclosporin A administration may impair the mechanical retention of dental implants previously integrated to the bone.
Resumo:
Objective: the aim of this study was to assess, through Raman spectroscopy, the incorporation of calcium hydroxyapatite (CHA; similar to 960 cm(-1)), and scanning electron microscopy (SEM), the bone quality on the healing bone around dental implants after laser photobiomodulation ( lambda 830 nm). Background Data: Laser photobiomodulation has been successfully used to improve bone quality around dental implants, allowing early wearing of prostheses. Methods: Fourteen rabbits received a titanium implant on the tibia; eight of them were irradiated with lambda 830 nm laser ( seven sessions at 48-h intervals, 21.5 J/cm(2) per point, 10 mW, phi similar to 0.0028 cm(2), 86 J per session), and six acted as control. The animals were sacrificed 15, 30, and 45 days after surgery. Specimens were routinely prepared for Raman spectroscopy and SEM. Eight readings were taken on the bone around the implant. Results: the results showed significant differences on the concentration of CHA on irradiated and control specimens at both 30 and 45 days after surgery ( p < 0.001). Conclusion: It is concluded that infrared laser photobiomodulation does improve bone healing, and this may be safely assessed by Raman spectroscopy or SEM.
Resumo:
In recent years, there has been a great interest in the development of biomaterials that could be used in the repair of bone defects. Collagen matrix (CM) has the advantage that it can be modified chemically to improve its mechanical properties. The aim of the present study was to evaluate the effect of three-dimensional membranes of native or anionic (submitted to alkaline treatment for 48 or 96 h) collagen matrix on the consolidation of osteoporosis bone fractures resulting from the gonadal hormone alterations caused by ovariectomy in rats subjected to hormone replacement therapy. The animals received the implants 4 months after ovariectomy and were sacrificed 8 weeks after implantation of the membranes into 4-mm wide bone defects created in the distal third of the femur with a surgical bur. Macroscopic analysis revealed the absence of pathological alterations in the implanted areas, suggesting that the material was biocompatible. Microscopic analysis showed a lower amount of bone ingrowth in the areas receiving the native membrane compared to the bone defects filled with the anionic membranes. In ovariectomized animals receiving anionic membranes, a delay in bone regeneration was observed mainly in animals not subjected to hormone replacement therapy. We conclude that anionic membranes treated with alkaline solution for 48 and 96 h presented better results in terms of bone ingrowth.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
AimTo compare the influence of autologous or deproteinized bovine bone mineral as grafting material on healing of buccal dehiscence defects at implants installed immediately into the maxillary second incisor extraction socket in dogs.Material and methodsIn the maxillary second incisor sockets of 12 Labrador dogs, implants were installed immediately following tooth extraction. A standardized buccal defect was created and autologous bone particles or deproteinized bovine bone mineral were used to fill the defects. A collagen membrane was placed to cover the graft material, and the flaps were sutured to fully submerge the experimental areas. Six animals were sacrificed after 2 months, and six after 4 months of healing. Ground sections were obtained for histological evaluation.ResultsAfter 2 months of healing, all implants were osseointegrated. All buccal dehiscence defects were completely filled after 2 months irrespective of the augmentation material (autologous bone or Bio-Oss (R)) applied. Bone-to-implant contact (BIC) on the denuded implant surfaces was within a normal range of 30-40%. However, the newly formed tissue at 2 months was partially resorbed (> 50% of the area measurements) after 4 months.ConclusionsApplying either autologous bone or deproteinized bovine bone mineral to dehiscences at implants installed immediately into extraction sockets resulted in high degree of regeneration of the defects with satisfactory BIC on the denuded implant surface.To cite this article:De Santis E, Botticelli D, Pantani F, Pereira FP, Beolchini M, Lang NP. Bone regeneration at implants placed into extraction sockets of maxillary incisors in dogs.Clin. Oral Impl. Res. 22, 2011; 430-437.
Resumo:
Aim To evaluate the soft tissue and the dimensional changes of the alveolar bony crest at sites where deproteinized bovine bone mineral (DBBM) particles, concomitantly with the placement of a collagen membrane, were used at implants installed into sockets immediately after tooth extraction. Material and methods The pulp tissue of the mesial roots of 3P3 was removed in six Labrador dogs, and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned, and the distal roots removed. Recipient sites were prepared in the distal alveolus, and implants were placed. At the test sites, DBBM particles were placed in the residual marginal defects concomitantly with the placement of a collagen membrane. No treatment augmentation was performed at the control sites. A non-submerged healing was allowed. Impressions were obtained at baseline and at the time of sacrifice performed 4 months after surgery. The cast models obtained were analyzed using an optical system to evaluate dimensional variations. Block sections of the implant sites were obtained for histological processing and soft tissue assessments. Results After 4 months of healing, no differences in soft tissue dimensions were found between the test and control sites based on the histological assessments. The location of the soft tissue at the buccal aspect was, however, more coronal at the test compared with the control sites (1.8 +/- 0.8 and 0.9 +/- 0.8 mm, respectively). At the three-dimensional evaluation, the margin of the soft tissues at the buccal aspect appeared to be located more apically and lingually. The vertical dislocation was 1 +/- 0.6 and 2.7 +/- 0.5 mm at the test and control sites, respectively. The area of the buccal shrinkage of the alveolar crest was significantly smaller at the test sites (5.9 +/- 2.4 mm2) compared with the control sites (11.5 +/- 1.7 mm2). Conclusion The use of DBBM particles concomitantly with the application of a collagen membrane used at implants placed into sockets immediately after tooth extraction contributed to the preservation of the alveolar process.
Resumo:
Aim: To evaluate the influence of deproteinized bovine bone mineral (DBBM) particles concomitant with the placement of a collagen membrane on alveolar ridge preservation and on osseointegration of implants placed into alveolar sockets immediately after tooth extraction. Material and methods: The pulp tissue of the mesial roots of 3P3 was removed in six Labrador dogs and the root canals were filled. Flaps were elevated in the right side of the mandible, and the buccal and lingual alveolar bony plates were exposed. The third premolar was hemi-sectioned and the distal root was removed. A recipient site was prepared and an implant was placed lingually. After implant installation, defects of about 0.6mm wide and 3.1mm depth resulted at the buccal aspects of the implant, both at the test and at the control sites. The same surgical procedures and measurements were performed on the left side of the mandible. However, DBBM particles with a size of 0.25-1mm were placed into the remaining defect concomitant with the placement of a collagen membrane. Results: All implants were integrated into mature bone. No residual DBBM particles were detected at the test sites after 4 months of healing. Both the test and the control sites showed buccal alveolar bone resorption, 1.8 +/- 1.1 and 2.1 +/- 1mm, respectively. The most coronal bone-to-implant contact at the buccal aspect was 2 +/- 1.1 an 2.8 +/- 1.3mm, at the test and the control sites, respectively. This difference in the distance was statistically significant. Conclusion: The application of DBBM concomitant with a collagen membrane to fill the marginal defects around implants placed into the alveolus immediately after tooth extraction contributed to improved bone regeneration in the defects. However, with regard to buccal bony crest preservation, a limited contribution of DBBM particles was achieved.