965 resultados para Body fluids Regulation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Heart failure (HF) affects approximately 23 million individuals worldwide and this number is increasing, due to an aging and growing population. Early detection of HF is crucial in the management of this debilitating disease. Current diagnostic methods for HF rely heavily on clinical imaging techniques and blood analysis, which makes them less than ideal for population-based screening purposes. Studies focusing on developing novel biomarkers for HF have utilized various techniques and biological fluids, including urine and saliva. Promising results from these studies imply that these body fluids can be used in evaluating the clinical manifestation of HF and will one day be integrated into a clinical workflow and facilitate HF management.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Determination of testosterone and related compounds in body fluids is of utmost importance in doping control and the diagnosis of many diseases. Capillary electromigration techniques are a relatively new approach for steroid research. Owing to their electrical neutrality, however, separation of steroids by capillary electromigration techniques requires the use of charged electrolyte additives that interact with the steroids either specifically or non-specifically. The analysis of testosterone and related steroids by non-specific micellar electrokinetic chromatography (MEKC) was investigated in this study. The partial filling (PF) technique was employed, being suitable for detection by both ultraviolet spectrophotometry (UV) and electrospray ionization mass spectrometry (ESI-MS). Efficient, quantitative PF-MEKC UV methods for steroid standards were developed through the use of optimized pseudostationary phases comprising surfactants and cyclodextrins. PF-MEKC UV proved to be a more sensitive, efficient and repeatable method for the steroids than PF-MEKC ESI-MS. It was discovered that in PF-MEKC analyses of electrically neutral steroids, ESI-MS interfacing sets significant limitations not only on the chemistry affecting the ionization and detection processes, but also on the separation. The new PF-MEKC UV method was successfully employed in the determination of testosterone in male urine samples after microscale immunoaffinity solid-phase extraction (IA-SPE). The IA-SPE method, relying on specific interactions between testosterone and a recombinant anti-testosterone Fab fragment, is the first such method described for testosterone. Finally, new data for interactions between steroids and human and bovine serum albumins were obtained through the use of affinity capillary electrophoresis. A new algorithm for the calculation of association constants between proteins and neutral ligands is introduced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Estrogens the female sex hormones have numerous biological actions. Estradiol is the most abundant estrogen in women before menopause. It influences the development, maturation and function of the female reproductive tract. It also plays a role in mammary cancer. Accordingly determinations of estradiol level in body fluids assist in the evaluation of ovarian function and diagnosis for malignancies. Estriol is the primary estrogen in pregnant women and secreted from the fetoplacental unit. Measurement of estriol in maternal body fluids is the basis of fetoplacental monitoring test. Concentration of estrogens in body fluids is determined by immunoassay. Accuracy of this measurement depends on the availability of a specific antibody. As estrogens are not antigenic, their derivatives (haptens) are coupled with a carrier and this hapten-protein conjugate is used to generate antibodies. Specificity of the generated antibody largely depends on the structure of hapten. Therefore the synthesis of a hapten with a right structure is crucial for the accurate measurement of a steroid. We have synthesised new haptens for estradiol and estriol by adding an alkyl or alkoxy side chain at the C-7 of estrane skeleton. The side chains carry a terminal amino group, which can be used for conjugation with a carrier molecule. Estrogens and their biosynthetic precursor androgens both exist as fatty acid esters. They are known to act as hormone storage but their physiological role is not completely known yet. Our collaborator is studying their effect in cardiovascular diseases. We synthesised fatty acid ester derivatives of several steroids in high yield by a very rapid procedure (in 1 min) under microwave irradiation in an ionic liquid (IL). An expedient regioselective hydrolysis at C-3 of estradiol diesters is also reported. 8-Isoestrogens are compounds of pharmaceutical interests, their synthesis, structure, conformation and biological activity studies are ongoing. 7-Hydroxy-8-isoestradiol and 7-alkyl ether of it were synthesised as well. During this study we have developed a selective O-debenzylation method. A mild route for selective removal of benzylic protection on phenol in presence of benzyl protected alcohol was explored.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

MEMS systems are technologically developed from integrated circuit industry to create miniature sensors and actuators. Originally these semiconductor processes and materials were used to build electrical and mechanical systems, but expanded to include biological, optical fluidic magnetic and other systems 12]. Here a novel approach is suggested where in two different fields are integrated via moems, micro fluidics and ring resonators. It is well known at any preliminary stage of disease onset, many physiological changes occur in the body fluids like saliva, blood, urine etc. The drawback till now was that current calibrations are not sensitive enough to detect the minor physiological changes. This is overcome using optical detector techniques 1]. The basic concepts of ring resonators, with slight variations can be used for optical detection of these minute disease markers. A well known fact of ring resonators is that a change in refractive index will trigger a shift in the resonant wavelength 5]. The trigger for the wavelength shift in the case discussed will be the presence of disease agents. To trap the disease agents specific antibody has to be used (e. g. BSA).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Branched Chain Amino Acids (BCAAs) are related to different aspects of diseases like pathogenesis, diagnosis and even prognosis. While in some diseases, levels of all the BCAAs are perturbed; in some cases, perturbation occurs in one or two while the rest remain unaltered. In case of ischemic heart disease, there is an enhanced level of plasma leucine and isoleucine but valine level remains unaltered. In `Hypervalinemia', valine is elevated in serum and urine, but not leucine and isoleucine. Therefore, identification of these metabolites and profiling of individual BCAA in a quantitative manner in body-fluid like blood plasma/serum have long been in demand. H-1 NMR resonances of the BCAAs overlap with each other which complicates quantification of individual BCAAs. Further, the situation is limited by the overlap of broad resonances of lipoprotein with the resonances of BCAAs. The widely used commercially available kits cannot differentially estimate the BCAAs. Here, we have achieved proper identification and characterization of these BCAAs in serum in a quantitative manner employing a Nuclear Magnetic Resonance-based technique namely T-2-edited Correlation Spectroscopy (COSY). This approach can easily be extended to other body fluids like bile, follicular fluids, saliva, etc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Reverse iontophoresis (RI) is one of the potential techniques used to monitor the concentration of various analytes in body fluids non -invasively. Transdermal extraction of potassium is investigated using RI. In the present work, the effect of potassium on stratum corneum (SC) during RI, feasibility of RI for continuous monitoring of potassium, and use of potassium as internal standard in RI, are investigated. Methods: Tape stripping experiment is carried out to find potassium concentration in SC. RI is carried out continuously for 180 min without passive diffusion and after passive diffusion for 60 min. Skin impedance measurements are done at 20 Hz and 20 kHz. Results: Potassium is found to be in the range 300-650 nmol/cm(2) on SC by tape stripping experiment. Correlation coefficient between blood potassium and extracted potassium through RI after passive diffusion (R-2 = 0.5870) is more than without passive diffusion (R-2 = 0.5117). The skin impedance measurement shows that RI has more effect on SC than superficial layer of SC during RI. Conclusion: The present investigations conclude that it is possible to monitor potassium continuously through RI and using potassium as internal standard in RI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Serotonin is a neurotransmitter that has been linked to a wide variety of behaviors including feeding and body-weight regulation, social hierarchies, aggression and suicidality, obsessive compulsive disorder, alcoholism, anxiety, and affective disorders. Full understanding of serotonergic systems in the central nervous system involves genomics, neurochemistry, electrophysiology, and behavior. Though associations have been found between functions at these different levels, in most cases the causal mechanisms are unknown. The scientific issues are daunting but important for human health because of the use of selective serotonin reuptake inhibitors and other pharmacological agents to treat disorders in the serotonergic signaling system. METHODS: We construct a mathematical model of serotonin synthesis, release, and reuptake in a single serotonergic neuron terminal. The model includes the effects of autoreceptors, the transport of tryptophan into the terminal, and the metabolism of serotonin, as well as the dependence of release on the firing rate. The model is based on real physiology determined experimentally and is compared to experimental data. RESULTS: We compare the variations in serotonin and dopamine synthesis due to meals and find that dopamine synthesis is insensitive to the availability of tyrosine but serotonin synthesis is sensitive to the availability of tryptophan. We conduct in silico experiments on the clearance of extracellular serotonin, normally and in the presence of fluoxetine, and compare to experimental data. We study the effects of various polymorphisms in the genes for the serotonin transporter and for tryptophan hydroxylase on synthesis, release, and reuptake. We find that, because of the homeostatic feedback mechanisms of the autoreceptors, the polymorphisms have smaller effects than one expects. We compute the expected steady concentrations of serotonin transporter knockout mice and compare to experimental data. Finally, we study how the properties of the the serotonin transporter and the autoreceptors give rise to the time courses of extracellular serotonin in various projection regions after a dose of fluoxetine. CONCLUSIONS: Serotonergic systems must respond robustly to important biological signals, while at the same time maintaining homeostasis in the face of normal biological fluctuations in inputs, expression levels, and firing rates. This is accomplished through the cooperative effect of many different homeostatic mechanisms including special properties of the serotonin transporters and the serotonin autoreceptors. Many difficult questions remain in order to fully understand how serotonin biochemistry affects serotonin electrophysiology and vice versa, and how both are changed in the presence of selective serotonin reuptake inhibitors. Mathematical models are useful tools for investigating some of these questions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The detection of the illegal use of clenbuterol (CBL) as a growth promoter has relied on detecting residual concentrations of the drug in body fluids or tissues. Analysis of retinal extracts has recently been shown to considerably extend the detection period following withdrawal. The withdrawal periods required to eliminate residues from the liver and retina were investigated by medicating 20 cattle with CBL for 30 days; 6 control animals remained unmedicated. Residual concentrations were monitored throughout this period and for the subsequent 140 days. Concurrent changes in muscle areas and backfat thicknesses were recorded by ultrasound.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Infections by multidrug-resistant bacteria are of great concern worldwide. In many cases, resistance is not due to the presence of specific antibiotic-modifying enzymes, but rather associated with a general impermeability of the bacterial cell envelope. The molecular bases of this intrinsic resistance are not completely understood. Moreover, horizontal gene transfers cannot solely explain the spread of intrinsic resistance among bacterial strains. Areas covered: This review focuses on the increased intrinsic antibiotic resistance mediated by small molecules. These small molecules can either be secreted from bacterial cells of the same or different species (e.g., indole, polyamines, ammonia, and the Pseudomonas quinolone signal) or be present in the bacterial cell milieu, whether in the environment, such as indole acetic acid and other plant hormones, or in human tissues and body fluids, such as polyamines. These molecules are metabolic byproducts that act as infochemicals and modulate bacterial responses toward antibiotics leading to increasing or decreasing resistance levels. Expert opinion: The non-genetic mechanisms of antibiotic response modulation and communication discussed in this review should reorient our thinking of the mechanisms of intrinsic resistance to antibiotics and its spread across bacterial cell populations. The identification of chemical signals mediating increased intrinsic antibiotic resistance will expose novel critical targets for the development of new antimicrobial strategies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Patients who cannot secrete ABO and Lewis blood group antigens into body fluids, an ability controlled by a single gene on chromosome 19, are known to be at increased risk of certain autoimmune diseases associated with human leucocyte antigen (HLA) markers. This study investigated the possibility of an association with coeliac disease using red cell Lewis (Le) blood group phenotype to infer secretor status. Among 73 patients with coeliac disease who had Le a or b antigen, 48% were non-secretors (Le a + b-) compared with 27% of 137 blood donors (p = 0.004: odds ratio 2.49, 95% confidence intervals 1.37 to 4.51) and 26% of 62 medical and nursing staff controls (p = 0.014: odds ratio 2.65, 95% confidence intervals 1.27 to 5.50). Clinical characteristics did not differ between secretors and non-secretors with coeliac disease. Thus, the non-secretor state is significantly associated with coeliac disease, suggesting that genes on chromosome 19 may directly or indirectly participate in conferring susceptibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exposure assessment is a critical part of epidemiological studies into the effect of mycotoxins on human health. Whilst exposure assessment can be made by estimating the quantity of ingested toxins from food analysis and questionnaire data, the use of biological markers (biomarkers) of exposure can provide a more accurate measure of individual level of exposure in reflecting the internal dose. Biomarkers of exposure can include the excreted toxin or its metabolites, as well as the products of interaction between the toxin and macromolecules such as protein and DNA. Samples in which biomarkers may be analysed include urine, blood, other body fluids and tissues, with urine and blood being the most accessible for human studies. Here we describe the development of biomarkers of exposure for the assessment of three important mycotoxins; aflatoxin, fumonisin and deoxynivalenol. A number of different biomarkers and methods have been developed that can be applied to human population studies, and these approaches are reviewed in the context of their application to molecular epidemiology research.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biomarkers are conventionally defined as "biological molecules that represent health and disease states." They typically are measured in readily available body fluids (blood or urine), lie outside the causal pathway, are able to detect subclinical disease, and are used to monitor clinical and subclinical disease burden and response to treatments. Biomarkers can be "direct" endpoints of the disease itself, or "indirect" or surrogate endpoints. New technologies (such as metabolomics, proteomics, genomics) bring a wealth of opportunity to develop new biomarkers. Other new technologies enable the development of nonmolecular, functional, or biophysical tissue-based biomarkers. Diabetes mellitus is a complex disease affecting almost every tissue and organ system, with metabolic ramifications extending far beyond impaired glucose metabolism. Biomarkers may reflect the presence and severity of hyperglycemia (ie, diabetes itself) or the presence and severity of the vascular complications of diabetes. Illustrative examples are considered in this brief review. In blood, hemoglobin A1c (HbA1c) may be considered as a biomarker for the presence and severity of hyperglycemia, implying diabetes or prediabetes, or, over time, as a "biomarker for a risk factor," ie, hyperglycemia as a risk factor for diabetic retinopathy, nephropathy, and other vascular complications of diabetes. In tissues, glycation and oxidative stress resulting from hyperglycemia and dyslipidemia lead to widespread modification of biomolecules by advanced glycation end products (AGEs). Some of these altered species may serve as biomarkers, whereas others may lie in the causal pathway for vascular damage. New noninvasive technologies can detect tissue damage mediated by AGE formation: these include indirect measures such as pulse wave analysis (a marker of vascular dysfunction) and more direct markers such as skin autofluorescence (a marker of long-term accumulation of AGEs). In the future, we can be optimistic that new blood and tissue-based biomarkers will enable the detection, prevention, and treatment of diabetes and its complications long before overt disease develops.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

3-Deoxyglucosone (3-DG) is a reactive dicarbonyl sugar thought to be a key intermediate in the nonenzymatic polymerization and browning of proteins by glucose. 3-DG may be formed in vivo from fructose, fructose 3-phosphate, or Amadori adducts to protein, such as N epsilon-fructoselysine (FL), all of which are known to be elevated in body fluids or tissues in diabetes. Modification of proteins by 3-DG formed in vivo is thought to be limited by enzymatic reduction of 3-DG to less reactive species, such as 3-deoxyfructose (3-DF). In this study, we have measured 3-DF, as a metabolic fingerprint of 3-DG, in plasma and urine from a group of diabetic patients and control subjects. Plasma and urinary 3-DF concentrations were significantly increased in the diabetic compared with the control population (0.853 +/- 0.189 vs. 0.494 +/- 0.072 microM, P <0.001, and 69.9 +/- 44.2 vs. 38.7 +/- 16.1 nmol/mg creatinine, P <0.001, respectively). Plasma and urinary 3-DF concentrations correlated strongly with one another, with HbA1c (P <0.005 in all cases), and with urinary FL (P <0.02 and P = 0.005, respectively). The overall increase in 3-DF concentrations in plasma and urine in diabetes and their correlation with other indexes of glycemic control suggest that increased amounts of 3-DG are formed in the body during hyperglycemia in diabetes and then metabolized to 3-DF. These observations are consistent with a role for increased formation of the dicarbonyl sugar 3-DG in the accelerated browning of tissue proteins in diabetes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper brings together and analyzes recent work based on the interpretation of the electrochemical measurements made on a modified micro-abrasion-corrosion tester used in several research programmes. These programmes investigated the role of abradant size, test solution pH in abrasion-corrosion of biomaterials, the abrasion-corrosion performance of sintered and thermally sprayed tungsten carbide surfaces under downhole drilling environments and the abrasion-corrosion of UNS S32205 duplex stainless steel. Various abrasion tests were conducted under two-body grooving, three-body rolling and mixed grooving-rolling abrasion conditions, with and without abrasives, on cast F75 cobalt-chromium-molybdenum (CoCrMo) alloy in simulated body fluids, 2205 in chloride containing solutions as well as sprayed and sintered tungsten carbide surfaces in simulated downhole fluids. Pre- and post-test inspections based on optical and scanning electron microscopy analysis are used to help interpret the electrochemical response and current noise measurements made in situ during micro-abrasion-corrosion tests. The complex wear and corrosion mechanisms and their dependence on the microstructure and surface composition as a function of the pH, abrasive concentration, size and type are detailed and linked to the electrochemical signals. The electrochemical versus mechanical processes are plotted for different test parameters and this new approach is used to interpret tribo-corrosion test data to give greater insights into different tribo-corrosion systems. Thus new approaches to interpreting in-situ electrochemical responses to surfaces under different abrasive wear rates, different abrasives and liquid environments (pH and NaCl levels) are made. This representation is directly related to the mechano-electrochemical processes on the surface and avoids quantification of numerous synergistic, antagonistic and additive terms associated with repeat experiments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho teve como objetivo principal estudar o comportamento mecânico do disco intervertebral recorrendo a sensores em fibra ótica. Na expetativa de efetuar o melhor enquadramento do tema foi efetuada uma revisão exaustiva das várias configurações de sensores em fibra ótica que têm vindo a ser utilizadas em aplicações biomédicas e biomecânicas, nomeadamente para medição de temperatura, deformação, força e pressão. Nesse âmbito, procurou-se destacar as potencialidades dos sensores em fibra ótica e apresentá-los como uma tecnologia alternativa ou até de substituição das tecnologias associadas a sensores convencionais. Tendo em vista a aplicação de sensores em fibra ótica no estudo do comportamento do disco intervertebral efetuou-se também uma revisão exaustiva da coluna vertebral e, particularmente, do conceito de unidade funcional. A par de uma descrição anatómica e funcional centrada no disco intervertebral, vértebras adjacentes e ligamentos espinais foram ainda destacadas as suas propriedades mecânicas e descritos os procedimentos mais usuais no estudo dessas propriedades. A componente experimental do presente trabalho descreve um conjunto de experiências efetuadas com unidades funcionais cadavéricas utilizando sensores convencionais e sensores em fibra ótica com vista à medição da deformação do disco intervertebral sob cargas compressivas uniaxiais. Inclui ainda a medição in vivo da pressão intradiscal num disco lombar de uma ovelha sob efeito de anestesia. Para esse efeito utilizou-se um sensor comercial em fibra ótica e desenvolveu-se a respetiva unidade de interrogação. Finalmente apresenta-se os resultados da investigação em curso que tem como objetivo propor e desenvolver protótipos de sensores em fibra ótica para aplicações biomédicas e biomecânicas. Nesse sentido, são apresentadas duas soluções de sensores interferométricos para medição da pressão em fluídos corporais.