970 resultados para Blood sugar monitoring.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Renal cytochrome P450 3A5 (CYP3A5) activity has been associated with blood pressure and salt sensitivity in humans. We determined whether CYP3A5 polymorphisms are associated with ambulatory blood pressure (ABP) and with glomerular filtration rate (GFR) in African families. METHODS: Using a cross-sectional design, 375 individuals from 72 families, each with at least two hypertensive siblings, were recruited through a hypertension register in the Seychelles (Indian Ocean). We analyzed the association between the CYP3A5 alleles (*1, *3, *6 and *7) and ABP, GFR and renal sodium handling (fractional excretion of lithium), from pedigree data, allowing for other covariates and familial correlations. RESULTS: CYP3A5*1 carriers increased their daytime systolic and diastolic ABP with age (0.55 and 0.23 mmHg/year) more than non-carriers (0.21 and 0.04 mmHg/year). CYP3A5*1 had a significant main effect on daytime systolic/diastolic ABP [regression coefficient (SE): -29.6 (10.0)/-8.2 (4.1) mmHg, P = 0.003/0.045, respectively] and this effect was modified by age (CYP3A5*1 x age interactions, P = 0.017/0.018). For night-time ABP, the effect of CYP3A5*1 was modified by urinary sodium excretion, not by age. For renal function, CYP3A5*1 carriers had a 7.6(3.8) ml/min lower GFR (P = 0.045) than non-carriers. Proximal sodium reabsorption decreased with age in non-carriers, but not in CYP3A5*1 carriers (P for interaction = 0.02). CONCLUSIONS: These data demonstrate that CYP3A5 polymorphisms are associated with ambulatory BP, CYP3A5*1 carriers showing a higher age- and sodium- related increase in ABP than non-carriers. The age effect may be due, in part, to the action of CYP3A5 on renal sodium handling.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The permeability-glycoprotein efflux-transporter encoded by the multidrug resistance 1 (ABCB1) gene and the cytochromes P450 3A4/5 encoded by the CYP3A4/5 genes are known to interact in the transport and metabolism of many drugs. Recent data have shown that the CYP3A5 genotypes influence blood pressure and that permeability-glycoprotein activity might influence the activity of the renin-angiotensin system. Hence, these 2 genes may contribute to blood pressure regulation in humans. We analyzed the association of variants of the ABCB1 and CYP3A5 genes with ambulatory blood pressure, plasma renin activity, plasma aldosterone, endogenous lithium clearance, and blood pressure response to treatment in 72 families (373 individuals; 55% women; mean age: 46 years) of East African descent. The ABCB1 and CYP3A5 genes interact with urinary sodium excretion in their effect on ambulatory blood pressure (daytime systolic: P=0.05; nighttime systolic and diastolic: P<0.01), suggesting a gene-gene-environment interaction. The combined action of these genes is also associated with postproximal tubular sodium reabsorption, plasma renin activity, plasma aldosterone, and with an altered blood pressure response to the angiotensin-converting enzyme inhibitor lisinopril (P<0.05). This is the first reported association of the ABCB1 gene with blood pressure in humans and demonstration that genes encoding for proteins metabolizing and transporting drugs and endogenous substrates contribute to blood pressure regulation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Whereas during the last few years handling of the transcutaneous PO2 (tcPO2) and PCO2 (tcPCO2) sensor has been simplified, the high electrode temperature and the short application time remain major drawbacks. In order to determine whether the application of a topical metabolic inhibitor allows reliable measurement at a sensor temperature of 42 degrees C for a period of up to 12 h, we performed a prospective, open, nonrandomized study in a sequential sample of 20 critically ill neonates. A total of 120 comparisons (six repeated measurements per patient) between arterial and transcutaneous values were obtained. Transcutaneous values were measured with a control sensor at 44 degrees C (conventional contact medium, average application time 3 h) and a test sensor at 42 degrees C (Eugenol solution, average application time 8 h). Comparison of tcPO2 and PaO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.16 kPa (range +1.60 to -2.00 kPa), limits of agreement +1.88 and -1.56 kPa. Comparison of tcPO2 and PaO2 at 44 degrees C (control sensor) revealed a mean difference of +0.02 kPa (range +2.60 to -1.90 kPa), limits of agreement +2.12 and -2.08 kPa. Comparison of tcPCO2 and PaCO2 at 42 degrees C (Eugenol solution) showed a mean difference of +0.91 (range +2.30 to +0.10 kPa), limits of agreement +2.24 and -0.42 kPa. Comparison of tcPCO2 and PaCO2 at 44 degrees C (control sensor) revealed a mean difference of +0.63 kPa (range 1.50 to -0.30 kPa), limits of agreement +1.73 and -0.47 kPa. CONCLUSION: Our results show that the use of an Eugenol solution allows reliable measurement of tcPO2 at a heating temperature of 42 degrees C; the application time can be prolongued up to a maximum of 12 h without aggravating the skin lesions. The performance of the tcPCO2 monitor was slightly worse at 42 degrees C than at 44 degrees C suggesting that for the Eugenol solution the metabolic offset should be corrected.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ambulatory blood pressure (BP) monitoring has become useful in the diagnosis and management of hypertensive individuals. In addition to 24-hour values, the circadian variation of BP adds prognostic significance in predicting cardiovascular outcome. However, the magnitude of circadian BP patterns in large studies has hardly been noticed. Our aims were to determine the prevalence of circadian BP patterns and to assess clinical conditions associated with the nondipping status in groups of both treated and untreated hypertensive subjects, studied separately. Clinical data and 24-hour ambulatory BP monitoring were obtained from 42,947 hypertensive patients included in the Spanish Society of Hypertension Ambulatory Blood Pressure Monitoring Registry. They were 8384 previously untreated and 34,563 treated hypertensives. Twenty-four-hour ambulatory BP monitoring was performed with an oscillometric device (SpaceLabs 90207). A nondipping pattern was defined when nocturnal systolic BP dip was <10% of daytime systolic BP. The prevalence of nondipping was 41% in the untreated group and 53% in treated patients. In both groups, advanced age, obesity, diabetes mellitus, and overt cardiovascular or renal disease were associated with a blunted nocturnal BP decline (P<0.001). In treated patients, nondipping was associated with the use of a higher number of antihypertensive drugs but not with the time of the day at which antihypertensive drugs were administered. In conclusion, a blunted nocturnal BP dip (the nondipping pattern) is common in hypertensive patients. A clinical pattern of high cardiovascular risk is associated with nondipping, suggesting that the blunted nocturnal BP dip may be merely a marker of high cardiovascular risk.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We estimated the heritability of ambulatory systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse pressure (PP) in east African families with at least 2 hypertensive siblings and living in the Seychelles islands (Indian Ocean). The sample consisted of 314 individuals (147 men and 167 women), both normotensive and hypertensive, from 76 pedigrees (mean+/-SD of 4.1+/-2.8 persons per pedigree). After a 2-week off-treatment period, daytime and nighttime ambulatory blood pressure (BP) was monitored. Office BP was measured with a standard mercury sphygmomanometer. We estimated by maximum likelihood the age- and sex-adjusted heritabilities from the additive polygenic component of the variance of the traits allowing for the presence of other familial correlations. We also adjusted for ascertainment (ie, for the fact that 2 siblings had to be hypertensive) and examined the effect of adjusting for body mass index, 24-hour urinary excretion of sodium and potassium, plasma renin activity, and plasma aldosterone concentration. Heritability estimates (+/-SE) for ambulatory SBP, DBP, and PP were, respectively, 0.37+/-0.12/0.24+/-0.12/0.54+/-0.12 for daytime and 0.34+/-0.13/ 0.37+/-0.15/0.47+/-0.12 for nighttime measurements (P<0.05 for all estimates). Heritability estimates for office SBP, DBP, and PP were, respectively, 0.20+/-0.11, 0.05+/-0.09, and 0.37+/-0.12. Heritability estimates for SBP varied markedly according to whether participants were treated for hypertension at baseline. The present data show that ambulatory BP and PP have a high heritability in families of African descent. They also demonstrate that antihypertensive treatment and the number of BP measurements have a major influence on the heritability estimates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Recent trials have documented no benefit from small reductions in blood pressure measured in the clinical office. However, ambulatory blood pressure is a better predictor of cardiovascular events than office-based blood pressure. We assessed control of ambulatory blood pressure in treated hypertensive patients at high cardiovascular risk. METHODS: We selected 4729 patients from the Spanish Ambulatory Blood Pressure Monitoring Registry. Patients were aged >/=55 years and presented with at least one of the following co-morbidities: coronary heart disease, stroke, and diabetes with end-organ damage. An average of 2 measures of blood pressure in the office was used for analyses. Also, 24-hour ambulatory blood pressure was recorded at 20-minute intervals with a SpaceLabs 90207 device. RESULTS: Patients had a mean age of 69.6 (+/-8.2) years, and 60.8% of them were male. Average time from the diagnosis of hypertension to recruitment into the Registry was 10.9 (+/-8.4) years. Mean blood pressure in the office was 152.3/82.3 mm Hg, and mean 24-hour ambulatory blood pressure was 133.3/72.4 mm Hg. About 60% of patients with an office-pressure of 130-139/85-89 mm Hg, 42.4% with office-pressure of 140-159/90-99 mm Hg, and 23.3% with office-pressure > or =160/100 mm Hg were actually normotensive, according to 24-hour ambulatory blood pressure criteria (<130/80 mm Hg). CONCLUSION: We suggest that the lack of benefit of antihypertensive therapy in some trials may partly be due to some patients having normal pressure at trial baseline. Ambulatory monitoring of blood pressure may allow for a better assessment of trial eligibility.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Postoperative neurosurgical patients are at risk of developing complications. Systemic and neuro-monitoring are used to identify patients who deteriorate in order to treat the underlying cause and minimize the impact on outcome. Hypotension and hypoxia are likely to be the most frequent insults and can be detected easily with blood pressure monitoring and pulse oximetry. Repeated clinical examination, however, is probably the most important monitor in the postoperative setting. Clinical scores such as the Glasgow Coma Score and the more recently introduced FOUR Score are important tools to standardize the clinical assessment. Intracranial pressure monitoring, cerebral blood flow monitoring, electroencephalography, and brain imaging are often used postoperatively. Despite the numerous publications on this topic only few studies address the impact of postoperative monitoring on outcome. Accordingly, in most patients the decision on which monitors are to be used must be based on the patient's presentation and clinical judgment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Blood pressure (BP) measured in obese patients with a large arm circumference using a cuff of standard width may be overestimated. METHODS: We compared in this study the BP readings obtained with oscillometric devices at the left arm (OMRON HEM 705-CP) and the left wrist (OMRON R6) (Omron Medizintechnik, Mannheim, Germany) in lean (n=15) and obese (n=11) patients. RESULTS: No difference was found in diastolic BP between the two groups, nor between the arm and the wrist. Systolic BP measured at the arm was, however, significantly lower in obese (99+/-9 mmHg, mean+/-SD) than in lean (107+/-14 mmHg; P<0.001) patients, whereas systolic BP determined at the wrist averaged 106 mmHg in both groups. CONCLUSION: The use of validated wrist BP measuring devices appears therefore particularly appealing in obese individuals with a large arm circumference

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Self-measurement of blood pressure (SMBP) is increasingly used to assess blood pressure outside the medical setting. A prerequisite for the wide use of SMBP is the availability of validated devices providing reliable readings when they are handled by patients. This is the case today with a number of fully automated oscillometric apparatuses. A major advantage of SMBP is the great number of readings, which is linked with high reproducibility. Given these advantages, one of the major indications for SMBP is the need for evaluation of antihypertensive treatment, either for individual patients in everyday practice or in clinical trials intended to characterize the effects of blood-pressure-lowering medications. In fact, SMBP is particularly helpful for evaluating resistant hypertension and detecting white-coat effect in patients exhibiting high office blood pressure under antihypertensive therapy. SMBP might also motivate the patient and improve his or her adherence to long-term treatment. Moreover, SMBP can be used as a sensitive technique for evaluating the effect of antihypertensive drugs in clinical trials; it increases the power of comparative trials, allowing one to study fewer patients or to detect smaller differences in blood pressure than would be possible with the office measurement. Therefore, SMBP can be regarded as a valuable technique for the follow-up of treated patients as well as for the assessment of antihypertensive drugs in clinical trials.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values <0.040). Similar inverse associations were observed for paraxanthine and theophylline. Adjusted night-time systolic blood pressure in the first (lowest), second, third, and fourth (highest) quartile of paraxanthine urinary excretions were 110.3, 107.3, 107.3, and 105.1 mm Hg, respectively (P trend <0.05). No associations of urinary excretions with diastolic blood pressure were generally found, and theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Do we need country-specific blood pressure reference values for children? This question will sound weird for clinicians caring for adult hypertensive patients or researchers working in the domain of adult hypertension. Indeed, there are no country-specific reference values for adults. This contrasts with hypertension in children, for whom there is an increasing number of published sets of country-specific reference values [1-5].

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a control strategy for blood glucose(BG) level regulation in type 1 diabetic patients. To design the controller, model-based predictive control scheme has been applied to a newly developed diabetic patient model. The controller is provided with a feedforward loop to improve meal compensation, a gain-scheduling scheme to account for different BG levels, and an asymmetric cost function to reduce hypoglycemic risk. A simulation environment that has been approved for testing of artificial pancreas control algorithms has been used to test thecontroller. The simulation results show a good controller performance in fasting conditions and meal disturbance rejection, and robustness against model–patient mismatch and errors in mealestimation