984 resultados para Bioelectrical-impedance Analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The nutritional status of cystic fibrosis (CF) patients has to be regularly evaluated and alimentary support instituted when indicated. Bio-electrical impedance analysis (BIA) is a recent method for determining body composition. The present study evaluates its use in CF patients without any clinical sign of malnutrition. Thirty-nine patients with CF and 39 healthy subjects aged 6-24 years were studied. Body density and mid-arm muscle circumference were determined by anthropometry and skinfold measurements. Fat-free mass was calculated taking into account the body density. Muscle mass was obtained from the urinary creatinine excretion rate. The resistance index was calculated by dividing the square of the subject's height by the body impedance. We show that fat-free mass, mid-arm muscle circumference and muscle mass are each linearly correlated to the resistance index and that the regression equations are similar for both CF patients and healthy subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nutrition assessment is important during chronic respiratory insufficiency to evaluate the level of malnutrition or obesity and should include body composition measurements. The appreciation of fat-free and fat reserves in patients with chronic respiratory insufficiency can aid in designing an adapted nutritional support, e.g., nutritional support in malnutrition and food restriction in obesity. The purpose of the present study was to cross-validate fat-free and fat mass obtained by various bioelectric impedance (BIA) formulas with the fat-free and fat mass measured by dual-energy X-ray absorptiometry (DXA) and determine the formulas that are best suited to predict the fat-free and fat mass for a group of patients with severe chronic respiratory insufficiency. Seventy-five patients (15 women and 60 men) with chronic obstructive and restrictive respiratory insufficiency aged 45-86 y were included in this study. Body composition was calculated according to 13 different BIA formulas for women and 12 for men and compared with DXA. Because of the variability, calculated as 2 standard deviations, of +/- 5.0 kg fat-free mass for women and +/- 6.4 kg for men for the best predictive formula, the use of the various existing BIA formulas was considered not clinically relevant. Therefore disease-specific formulas for patients with chronic respiratory insufficiency should be developed to improve the prediction of fat-free and fat mass by BIA in these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop specific equations for the neonatal population to determine body fluid compartments. Bioelectric impedance measurements were performed by a laboratory homemade instrument. The volumes were estimated in a clinical study on 30 full-term neonates at four different times during the first month of life. During the first 24 hours of life the total body water, extracellular water and intracellular water were 2.09 ± 0.25, 1.20 ± 0.19, and 0.90 ± 0.25 liters, respectively. By the 48th hour they were 1.87 ± 0.27, 1.08 ± 0.17, and 0.79 ± 0.21 liters, respectively. On the 10th day they were 2.02 ± 0.25, 1.29 ± 0.21, and 0.72 ± 0.14 liters, respectively, and after 1 month they were 2.34 ± 0.27, 1.62 ± 0.20, and 0.72 ± 0.13 liters, respectively. The behavior of the estimated volume was correlated with neonatal body weight changes, leading to a better interpretation of such changes. In conclusion, this study indicates the feasibility of bioelectrical impedance spectroscopy as a method to help fluid administration in intensive care neonatal units, and also contribute to the development of new equations to estimate neonatal body fluid contents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of the present study were to describe and compare the body composition variables determined by bioelectrical impedance (BIA) and the deuterium dilution method (DDM), to identify possible correlations and agreement between the two methods, and to construct a linear regression model including anthropometric measures. Obese adolescents were evaluated by anthropometric measures, and body composition was assessed by BIA and DDM. Forty obese adolescents were included in the study. Comparison of the mean values for the following variables: fat body mass (FM; kg), fat-free mass (FFM; kg), and total body water (TBW; %) determined by DDM and by BIA revealed significant differences. BIA overestimated FFM and TBW and underestimated FM. When compared with data provided by DDM, the BIA data presented a significant correlation with FFM (r = 0.89; P < 0.001), FM (r = 0.93; P < 0.001) and TBW (r = 0.62; P < 0.001). The Bland-Altman plot showed no agreement for FFM, FM or TBW between data provided by BIA and DDM. The linear regression models proposed in our study with respect to FFM, FM, and TBW were well adjusted. FFM obtained by DDM = 0.842 x FFM obtained by BIA. FM obtained by DDM = 0.855 x FM obtained by BIA + 0.152 x weight (kg). TBW obtained by DDM = 0.813 x TBW obtained by BIA. The body composition results of obese adolescents determined by DDM can be predicted by using the measures provided by BIA through a regression equation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically developed for a Latin-American population. A cross-sectional study. Twenty one volunteers were studied, 12 women, with mean age 72 +/- 6.7 years. Urban community, Ribeiro Preto, Brazil. Fat free mass was determined, simultaneously, by the deuterium dilution method and bioelectrical impedance; results were compared. In bioelectrical impedance, body composition was calculated by the formulas of Deuremberg, Lukaski and Bolonchuck and Valencia et al. Lean body mass of the studied volunteers, as determined by bioelectrical impedance was 37.8 +/- 9.2 kg by the application of the Lukaski e Bolonchuk formula, 37.4 +/- 9.3 kg (Deuremberg) and 43.2 +/- 8.9 kg (Valencia et. al.). The results were significantly correlated to those obtained by the deuterium dilution method (41.6 +/- 9.3 Kg), with r=0.963, 0.932 and 0.971, respectively. Lean body mass obtained by the Valencia formula was the most accurate. In this study, lean body mass of older persons obtained by the bioelectrical impedance method showed good correlation with the values obtained by the deuterium dilution method. The formula of Valencia et al., developed for a Latin-American population, showed the best accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectional observational study in 84 term and near-term healthy neonates less than 12 h postpartum. Whole body and cerebral MFBIA measurements were performed at the bedside in the post-natal ward. Gestational age, post-natal age, gender, birthweight, head circumference and foot length measures were recorded. Reference values for impedance at the characteristic frequency (Z(C)) and resistance at zero frequency (R-0) are reported for whole body and cerebral impedance. Significant correlations (p < 0.05) were observed between whole body impedance and birthweight, footlength and head circumference. Females had a significantly higher whole body R0 than males. Cerebral impedance did not correlate significantly with any of the demographic measures and therewere no gender differences observed for cerebral impedance. The reference range for whole body multi-frequency bio-impedance values in term and near-term infants within the first 12 h postpartum can be calculated from the footlength (FL) using the following equations: Z(C) = (942.9 - 4.818* FL) +/- 124.6 Omega; R-0 = (1042 - 4.520(*)FL) +/- 135.5 Omega. For cerebral impedance the reference range is 29.5-48.7 Omega for Z(C) and 33.7-58.0 Omega for R-0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impedance spectroscopy (IS) analysis is carried out to investigate the electrical properties of the metal-oxide-semiconductor (MOS) structure fabricated on hydrogen-terminated single crystal diamond. The low-temperature atomic layer deposition Al2O3 is employed as the insulator in the MOS structure. By numerically analysing the impedance of the MOS structure at various biases, the equivalent circuit of the diamond MOS structure is derived, which is composed of two parallel capacitive and resistance pairs, in series connection with both resistance and inductance. The two capacitive components are resulted from the insulator, the hydrogenated-diamond surface, and their interface. The physical parameters such as the insulator capacitance are obtained, circumventing the series resistance and inductance effect. By comparing the IS and capacitance-voltage measurements, the frequency dispersion of the capacitance-voltage characteristic is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this investigation was to develop new techniques to generate segmental assessments of body composition based on Segmental Bioelectrical Impedance Analysis (SBIA). An equally important consideration was the design, simulation, development, and the software and hardware integration of the SBIA system. This integration was carried out with a Very Large Scale Integration (VLSI) Field Programmable Gate Array (FPGA) microcontroller that analyzed the measurements obtained from segments of the body, and provided full body and segmental Fat Free Mass (FFM) and Fat Mass (FM) percentages. Also, the issues related to the estimate of the body's composition in persons with spinal cord injury (SCI) were addressed and investigated. This investigation demonstrated that the SBIA methodology provided accurate segmental body composition measurements. Disabled individuals are expected to benefit from these SBIA evaluations, as they are non-invasive methods, suitable for paralyzed individuals. The SBIA VLSI system may replace bulky, non flexible electronic modules attached to human bodies. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Body mass index (BMI) has been one of the methods most frequently used for diagnose obesity, but it isn't consider body composition. Objective: This study intends to apply one new adiposity index, the BMI adjusted for fat mass (BMIfat) developed by Mialich, et al. (2011), in a adult Brazilian sample. Methods: A cross-sectional study with 501 individuals of both genders (366 women, 135 men) aged 17 to 38 years and mean age was 20.4 ± 2.8 years, mean weight 63.0 ± 13.5 kg, mean height 166.9 ± 9.0 cm, and BMI 22.4 ± 3.4 kg/m². Results and discussion: High and satisfactory R2 values were obtained, i.e., 91.1%, 91.9% and 88.8% for the sample as a whole and for men and women, respectively. Considering this BMIfat were developed new ranges, as follows: 1.35 to 1.65 (nutritional risk for malnutrition), > 1.65 and ≤ 2.0 (normal weight) and > 2.0 (obesity). The BMIfat had a more accurate capacity of detecting obese individuals (0.980. 0.993, 0.974) considering the sample as a whole and women and men, respectively, compared to the traditional BMI (0.932, 0.956, 0.95). Were also defined new cut-off points for the traditional BMI for the classification of obesity, i.e.: 25.24 kg/m² and 28.38 kg/m² for men and women, respectively. Conclusion: The BMIfat was applied for the present population and can be adopted in clinical practice. Further studies are needed to determine its application to different ethnic groups and to compare this index to others previously described in the scientific literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Vesicoureteral reflux (VUR) is a common abnormality of the urinary tract in childhood. Objectives: As urine enters the ureters and renal pelvis during voiding in vesicoureteral reflux (VUR), we hypothesized that change in body water composition before and after voiding may be less different in children with VUR. Patients and Methods: Patients were grouped as those with VUR (Group 1) and without VUR (Group 2). Bioelectric impedance analysis was performed before and after voiding, and third space fluid (TSF) (L), percent of total body fluid (TBF%), extracellular fluid (ECF%), and intracellular fluid (ICF%) were recorded. After change of TSF, TBF, ECF, ICF (ΔTSF, ΔTBF%, ΔECF%, ΔICF%), urine volume (mL), and urine volume/body weight (mL/kg) were calculated. Groups 1 and 2 were compared for these parameters. In addition, pre- and post-voiding body fluid values were compared in each group. Results: TBF%, ECF%, ICF%, and TSF in both pre- and post-voiding states and ΔTBF%, ΔECF%, ΔICF%, and ΔTSF after voiding were not different between groups. However, while post-voiding TBF%, ECF% was significantly decreased in Group 1 (64.5 ± 8.1 vs 63.7 ± 7.2, P = 0.013 for TBF%), there was not post-voiding change in TSF in the same group. On the other hand, there was also a significant TSF decrease in Group 2. Conclusions: Bladder and ureter can be considered as the third space. Thus, we think that BIA has been useful in discriminating children with VUR as there was no decreased in patients with VUR, although there was decreased TSF in patients without VUR. However, further studies are needed to increase the accuracy of this hypothesis.