938 resultados para Basophil Degranulation Test -- methods
Resumo:
OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.
Resumo:
The basophil activation test (BAT) has become a pervasive test for allergic response through the development of flow cytometry, discovery of activation markers such as CD63 and unique markers identifying basophil granulocytes. Basophil activation test measures basophil response to allergen cross-linking IgE on between 150 and 2000 basophil granulocytes in <0.1 ml fresh blood. Dichotomous activation is assessed as the fraction of reacting basophils. In addition to clinical history, skin prick test, and specific IgE determination, BAT can be a part of the diagnostic evaluation of patients with food-, insect venom-, and drug allergy and chronic urticaria. It may be helpful in determining the clinically relevant allergen. Basophil sensitivity may be used to monitor patients on allergen immunotherapy, anti-IgE treatment or in the natural resolution of allergy. Basophil activation test may use fewer resources and be more reproducible than challenge testing. As it is less stressful for the patient and avoids severe allergic reactions, BAT ought to precede challenge testing. An important next step is to standardize BAT and make it available in diagnostic laboratories. The nature of basophil activation as an ex vivo challenge makes it a multifaceted and promising tool for the allergist. In this EAACI task force position paper, we provide an overview of the practical and technical details as well as the clinical utility of BAT in diagnosis and management of allergic diseases.
Resumo:
Background Obeche wood dust is a known cause of occupational asthma where an IgE-mediated mechanism has been demonstrated. Objective To characterize the allergenic profile of obeche wood dust and evaluate the reactivity of the proteins by in vitro, ex vivo and in vivo assays in carpenters with confirmed rhinitis and/or asthma Materials and methods An in-house obeche extract was obtained, and two IgE binding bands were purified (24 and 12 kDa) and sequenced by N-terminal identity. Specific IgE and IgG, basophil activation tests and skin prick tests (SPTs) were performed with whole extract and purified proteins. CCD binding was analyzed by ELISA inhibition studies. Results Sixty-two subjects participated: 12 with confirmed occupational asthma/rhinitis (ORA+), 40 asymptomatic exposed (ORA−), and 10 controls. Of the confirmed subjects, 83% had a positive SPT to obeche. There was a 100% recognition by ELISA in symptomatic subjects vs. 30% and 10% in asymptomatic exposed subjects and controls respectively (p<0.05). Two new proteins were purified, a 24 kDa protein identified as a putative thaumatin-like protein and a 12 kDa gamma-expansin. Both showed allergenic activity in vitro, with the putative thaumatin being the most active, with 92% recognition by ELISA and 100% by basophil activation test in ORA+ subjects. Cross-reactivity due to CCD was ruled out in 82% of cases. Conclusions Two proteins of obeche wood were identified and were recognized by a high percentage of symptomatic subjects and by a small proportion of asymptomatic exposed subjects. Further studies are required to evaluate cross reactivity with other plant allergens.
Resumo:
In 7 divisions, 1 and 7 originally issued July 18, 1930, and Nov. 26, 1929; each division with caption title: Symposium of test methods on coarse aggregates.
Resumo:
The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.
Resumo:
Background and aims: A gluten-free diet is to date the only treatment available to celiac disease sufferers. However, systematic reviews indicate that, depending on the method of evaluation used, only 42% to 91% of patients adhere to the diet strictly. Transculturally adapted tools that evaluate adherence beyond simple self-informed questions or invasive analyses are, therefore, of importance. The aim is to obtain a Spanish transcultural adaption and validation of Leffler's Celiac Dietary Adherence Test. Methods: A two-stage observational transversal study: translation and back translation by four qualified translators followed by a validation stage in which the questionnaire was administered to 306 celiac disease patients aged between 12 and 72 years and resident in Aragon. Factorial structure, criteria validity and internal consistency were evaluated. Results: The Spanish version maintained the 7 items in a 3-factor structure. Feasibility was very high in all the questions answered and the floor and ceiling effects were very low (4.3% and 1%, respectively). The Spearman correlation with the self-efficacy and life quality scales and the self-informed question were statistically significant (p < 0.01). According to the questionnaire criteria, adherence was 72.3%. Conclusion: The Spanish version of the Celiac Dietary Adherence Test shows appropriate psychometric properties and is, therefore, suitable for studying adherence to a gluten-free diet in clinical and research environments.
Resumo:
Background: Knowing one’s own seropositivity status of HIV/AIDS is important. Seropositivity can be determined by a rapid HIV/AIDS test. Attitudes towards a rapid test of HIV/AIDS show a predisposition to perform the analysis. Objective: This study investigated, the attitudes of students and staff in a Portuguese university toward rapid HIV/AIDS test. Methods: In a convenience sample, the data was collected on campus in three consecutive years. A selfadministered structured questionnaire was used for data collection. A validated scale for Portuguese students was applied. A sample of 947 (86.3%) students and 150 (13.7%) teaching and non-teaching staff participated. The average age was 24.30 years-old (SD=8.64). Non-parametric tests were applied. Results: Attitudes of professors and non-teaching staff are more favorable in relation to the rapid test of HIV/AIDS, compared to students. Attitudes are also more favorable in the first year in which the study was conducted with both employees and students. The male students express more traditional attitudes. Students of nursing polo have expressed more favorable attitudes to the rapid test of HIV/AIDS. Conclusion: The attitudes towards rapid test of HIV/AIDS are generally favorable. It is necessary to conduct further research considering professors and other university staff. Improving favorable attitudes toward rapid HIV/AIDS test must be a positive fact for health.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5%). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.
Resumo:
OBJETIVO: Comparar duas abordagens baseadas em critérios do Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e do Standards for Reporting Studies of Diagnostic Accuracy (STARD) na avaliação de qualidade de estudos de validação do teste rápido OptiMal®, para diagnóstico de malária. MÉTODOS: Foi realizada busca de artigos de validação do teste rápido na base bibliográfica Medline acessada pelo PubMed, no ano de 2007. Treze artigos foram recuperados na busca. Foram combinados 12 critérios do QUADAS e três do STARD para comparação com os critérios do QUADAS isoladamente. Foi considerado que artigos de regular a boa qualidade atenderiam pelo menos 50% dos critérios do QUADAS. RESULTADOS: Dos 13 artigos recuperados, 12 cumpriram pelo menos 50% dos critérios do QUADAS, e apenas dois atenderam à combinação dos critérios. Considerando-se a combinação dos dois critérios (> 6 QUADAS e > 3STARD), dois estudos (15,4%) apresentaram boa qualidade metodológica. A seleção de artigos usando a combinação proposta variou de dois a oito artigos, dependendo do número de itens considerados como ponto de corte. CONCLUSÕES: A combinação do QUADAS com o STARD tem o potencial de conferir maior rigor nas avaliações da qualidade de artigos publicados sobre validação de testes diagnósticos em malária, por incorporar a checagem de informações relevantes não alcançáveis pelo uso do QUADAS isoladamente.
Resumo:
Objective: To evaluate the adhesion of the endodontic sealers Epiphany, Apexit Plus, and AH Plus to root canal dentin submitted to different surface treatments, by using the push-out test. Methods: One hundred twenty-eight root cylinders obtained from maxillary canines were embedded in acrylic resin, had the canals prepared, and were randomly assigned to four groups (n = 32), according to root dentin treatment: (I) distilled water (control), (II) 17% EDTAC, (III) 1% NaOCl and (IV) Er:YAG laser with 16-Hz, 400-mJ input (240-mJ output) and 0.32-J/cm(2) energy density. Each group was divided into four subgroups (n = 8) filled with Epiphany (either dispensed from the automix syringe supplied by the manufacturer or prepared by hand mixing), Apexit Plus, or AH Plus. Data (MPa) were analyzed by ANOVA and Tukey's test. Results: A statistically significant difference (p < 0.01) was found among the root-canal sealers, except for the Epiphany subgroups, which had statistically similar results to each other (p > 0.01): AH Plus (4.77 +/- 0.85), Epiphany/hand mixed (3.06 +/- 1.34), Epiphany/automix syringe (2.68 +/- 1.35), and Apexit Plus (1.22 +/- 0.33). A significant difference (p < 0.01) was found among the dentin surface treatments. The highest adhesion values were obtained with AH Plus when root dentin was treated with Er: YAG laser and 17% EDTAC. Epiphany sealer presented the lowest adhesion values to root dentin treated with 17% EDTAC. Conclusions: The resin-based sealers had different adhesive behaviors, depending on the treatment of root canal walls. The mode of preparation of Epiphany (automix syringe or hand mixing) did not influence sealer adhesion to root dentin.
Resumo:
Purpose The aim of this study was to evaluate the ability of bond strength tests to accurately measure the bond strength of fiber posts luted into root canals Materials and Methods The test methods studied were hourglass microtensile (HM), push-out (PS), modified push out (MP) and pull out (PL) The evaluated parameters were bond strength values, reliability (using Weibull analysis), failure mode (using confocal microscopy), and stress distribution (using finite element analysis) Forty human intact single rooted and endodontically treated teeth were divided into four groups Each group was assigned one of the test methods The samples in the HM and PS groups were 1 0 +/- 0 1 mm thick, the HM samples were hourglass shaped and the PS samples were disk shaped For the PL and MP groups, each 1 mm dentin slice was luted with a fiber post piece Three dimensional models of each group were made and stress was analyzed based on Von Mises criteria Results PL provided the highest values of bond strength followed by MP both of which also had greater amounts of adhesive failures PS showed the highest frequency of cohesive failures MP showed a more homogeneous stress distribution and a higher Weibull modulus Conclusion The specimen design directly influences the biomechanical behavior of bond strength tests
Resumo:
A variabilidade natural dos solos torna complexo o conhecimento de suas propriedades na elaboração de projetos geotécnicos, sendo a determinação da resistência ao cisalhamento não drenada um parâmetro importante nas análises de estabilidade de solos moles. Os ensaios de laboratório de cone e palheta, não convencionais, os ensaios de campo de palheta e piezocone e os ensaios de compressão simples e triaxial não adensado e não drenado foram utilizados para mensurar a resistência não drenada de uma camada de argila marinha mole localizada na planície costeira central brasileira. Os ensaios de laboratório foram realizados em amostras indeformadas coletadas com amostradores de pistão estacionário em vertical próxima à realização dos ensaios de campo. O sítio foi investigado preliminarmente por sondagens de simples reconhecimento, sendo apresentado o perfil estratigráfico por meio de modelagem computacional. Foram também realizados ensaios para caracterização física (análise granulométrica, teor de umidade, limites de liquidez e plasticidade, densidade real dos grãos) e mineralógica (difração de raios X), e ensaios de adensamento para obtenção do histórico de tensões e classificação de qualidade das amostras indeformadas. Os valores de resistência não drenada obtidos pelos ensaios de laboratório foram comparados ao perfil contínuo de resistência determinado empiricamente pelo ensaio de piezocone, com fator de cone Nkt calibrado pelo ensaio de palheta de campo, apresentando boa concordância, com a variabilidade natural do solo influenciando de forma preponderante a qualidade das amostras na variação entre os resultados. Os valores de resistência obtidos pelos ensaios de laboratório de cone e palheta foram comparados entre si, apresentando boa compatibilidade. Ambos, quando comparados ao ensaio de palheta de campo, não apresentaram boa concordância. Os resultados de resistência obtidos pelos ensaios de compressão simples e triaxial apresentaram boa compatibilidade com os resultados do ensaio de laboratório de cone, o que não ocorreu com os resultados do ensaio de laboratório de palheta. Na comparação entre a resistência normalizada pela tensão de sobreadensamento obtida pelos diversos métodos e algumas correlações empíricas da literatura internacional, foi observado para as amostras de solo com índice de plasticidade superior a 60% boa concordância com as correlações de Mesri (1975) e Jamiolkowski et al (1985). Os ensaios não convencionais apresentaram boa confiabilidade, que aliado a simplicidade e agilidade de execução, justificam a difusão destes na prática da investigação geotécnica brasileira como método alternativo para complementar e dar suporte às estimativas de resistência não drenada de solos moles.
Resumo:
European Cetacean Society Conference Workshop, Galway, Ireland, 25th March 2012.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil