969 resultados para Band offset
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
OBJECTIVE - To determine if the application of a continuous electrode paste band on precordial leads results in alteration of the electrocardiographic tracing as compared with an adequate amount of electrode paste, and if the former condition does not cause uniform morphologies from V1 to V6. METHODS - The amplitude and morphology of the electrocardiographic waves on the precordial leads in electrocardiographic tracings, which were performed with standard (control group) or excessive (continuous band) application of the electrode paste, were compared. RESULTS - None of the 106 patients studied showed uniformity of the QRS morphology from V1 to V6. The eletrocardiographic alterations identified in the tracings performed with a continuous electrode paste band that showed statistical significance in relation to the control group were the following: inversion of the P wave in V1; inversion of the T wave in V1, V2, and V3; appearance of R' waves in V1 and V2; disappearance of S waves in V1; appearance of S waves in V5 and V6; alterations in the amplitude of almost all waves, in all leads. CONCLUSION - Application of a continuous electrode paste band in the precordial leads may cause significant alterations in the electrocardiographic tracing obtained.
Resumo:
Bd.8,hft.18-22,c.1
Resumo:
Bd.8,hft.18
Resumo:
Bd.8,hft.13
Resumo:
Bd.8,hft.12
Resumo:
Gamma-band activity, EEG, top-down, bottom-up
Resumo:
Magdeburg, Univ., Fak. für Natuwiss., Diss., 2009
Resumo:
Magdeburg, Univ., Medizin. Fak., Diss., 2004
Resumo:
This work describes a test tool that allows to make performance tests of different end-to-end available bandwidth estimation algorithms along with their different implementations. The goal of such tests is to find the best-performing algorithm and its implementation and use it in congestion control mechanism for high-performance reliable transport protocols. The main idea of this paper is to describe the options which provide available bandwidth estimation mechanism for highspeed data transport protocols and to develop basic functionality of such test tool with which it will be possible to manage entities of test application on all involved testing hosts, aided by some middleware.
Resumo:
Protein extracts obtained from male and female shistosomes were incubated with a gender-specific gene, F-10, transcribed only in adult females and encoding a major egg-shell protein. The protein/DNA interaction was measured using the band shift, DNase-I-footprinting and UV cross-linking techniques. The results showed a clear band shift when a 302 bp restriction fragment containing the 3'end of the gene was incubated with either female or male proteins. This fragment also contained a putative steroid hormone regulatory element (HRE). In contrast, only the male proteins produced a shift with the 495 bp fragment corresponding to the middle region of the gene. DNase I footprinting showed that proteins from males and females interacted with the F-10 gene by binding to multiple adjacent sites along the DNA, thus generatingrelatively long protected fragments of approximately 100 bp. This result suggested that the adjacent binding of several moles of proteins occured at the 5'end of the gene. UV cross-linking between schistosome proteins and a 21 bp synthetic oligonucleotide the F-10 HRE, evidence proteins having MWS of 30,45 and 65 kDNA. These proteins are presumably involved in the regulation of transcription of the F-10 gene.
Resumo:
There are far-reaching conceptual similarities between bi-static surface georadar and post-stack, "zero-offset" seismic reflection data, which is expressed in largely identical processing flows. One important difference is, however, that standard deconvolution algorithms routinely used to enhance the vertical resolution of seismic data are notoriously problematic or even detrimental to the overall signal quality when applied to surface georadar data. We have explored various options for alleviating this problem and have tested them on a geologically well-constrained surface georadar dataset. Standard stochastic and direct deterministic deconvolution approaches proved to be largely unsatisfactory. While least-squares-type deterministic deconvolution showed some promise, the inherent uncertainties involved in estimating the source wavelet introduced some artificial "ringiness". In contrast, we found spectral balancing approaches to be effective, practical and robust means for enhancing the vertical resolution of surface georadar data, particularly, but not exclusively, in the uppermost part of the georadar section, which is notoriously plagued by the interference of the direct air- and groundwaves. For the data considered in this study, it can be argued that band-limited spectral blueing may provide somewhat better results than standard band-limited spectral whitening, particularly in the uppermost part of the section affected by the interference of the air- and groundwaves. Interestingly, this finding is consistent with the fact that the amplitude spectrum resulting from least-squares-type deterministic deconvolution is characterized by a systematic enhancement of higher frequencies at the expense of lower frequencies and hence is blue rather than white. It is also consistent with increasing evidence that spectral "blueness" is a seemingly universal, albeit enigmatic, property of the distribution of reflection coefficients in the Earth. Our results therefore indicate that spectral balancing techniques in general and spectral blueing in particular represent simple, yet effective means of enhancing the vertical resolution of surface georadar data and, in many cases, could turn out to be a preferable alternative to standard deconvolution approaches.
Resumo:
Les ones passives mil·limètriques (30 a 300GHz) tenen la peculiaritat de propagar-se en medis com la boira o la roba, a diferència del rang visible o l’infraroig. D’aquesta peculiaritat, surt l’interès de reproduir imatges per diverses aplicacions (seguretat, vigilància, etc...). És per aquest motiu que es treballa en el disseny d’un reflector per aquest tipus d’aplicació, treballant a una de les finestres de propagació d’aquest rang, la de la banda W. Es dissenyen i analitzen tres tipus de reflector: parabòlic simètric, offset i Cassegrain. D’aquests, s’estudien les seves figures de mèrit i directivitats buscant que aquestes siguin el més elevades possibles per obtenir una bona resolució, així com l’escaneig de l’escena de la qual es vol obtenir una imatge, veient aquí els efectes de les aberracions més comunes.
Resumo:
BACKGROUND: In late-diagnosed transposition of the great arteries (TGA), the left ventricle (LV) involutes as it pumps against low resistance and needs retraining by applying a pulmonary artery band (PAB) in preparation for an arterial switch operation. We report our experience with a telemetrically adaptable band compared with classic banding. METHODS: Ten patients underwent retraining of the LV, 4 patients with an adaptable band and progressive weekly tightening of the band (group 1) and 6 patients with a traditional band (group 2). RESULTS: Mean weight and age at pulmonary band placement was 5.8 ± 2.36 kg and 11.7 ± 11.1 months for group 1 and 5.0 ± 2.3 kg and 6.4 ± 7.6 months for group 2. Time between palliation and switch procedure was 4.2 months in both groups. Group 1 showed an initial mean pulmonary gradient of 25.5 ± 4.43 mm Hg with a 5% closure of the device. The mean gradient increased with progressive closure to 63.5 ± 9.8 mm Hg at the time of the arterial switch operation. There were no reinterventions or deaths in this group. In group 2, the mean pulmonary gradient increased with growth from 49 ± 21.4 mm Hg to 68.4 ± 7.86 mm Hg at the time of the switch procedure. However, 4 of these patients required reoperations during retraining: 2 needed 1 reoperation and 2 needed 2 reoperations. Two patients died-1 after banding and 1 after the switch operation. CONCLUSIONS: Retraining of the LV by the adaptable device allows precise control of the tightening, avoids repetitive operations, and diminishes morbidity.