178 resultados para Balões volumétricos
Resumo:
The European Solar Engineering School ESES is a one-year masters program that started in 1999 at the Solar Energy Research Center SERC, Dalarna University College. It has been growing in popularity over the years, with over 20 students in the current year. Approximately half the students come from Europe, the rest coming from all over the globe. This paper described the contents and experiences from seven years of running the programme and the plans for adapting the programme to the Bologna process. The majority of the students from ESES have found work in the solar industry, energy industry or taken up PhD positions. An alumni group has been started that actively gives support to past, present and potential future students.
Resumo:
Within the frame of the project REBUS, "Competitive solar heating systems for residential buildings", which is financed by Nordic Energy Research, a new type of compact solar combisystem with high degree of prefabrication was developed. A hydraulic and control concept was designed with the goal to get highest system efficiency for use with either a condensing natural gas boiler or a pellet boiler. Especially when using the potential of high peak power of modern condensing natural gas boilers, a new operation strategy of a natural gas boiler/solar combisystem can increase the energy savings of a small solar combisystem by about 80% compared to conventional operation strategies.
Resumo:
Dagens vanliga ackumulatortanksystem har för dålig skiktning i ackumulatortanken, vilket leder till försämrad effektivitet hos systemen. För att förbättra den krävs komponenter, som kan ladda och framförallt urladda med bättre skiktningsegenskaper. Ackumulatorvärmesystem som t ex vedpanna med tank och solvärmesystem kan öka sin effektivitet, om tankens skiktning främjas. En ny typ av varmvattenberedare, sk tappvattenautomater har tagits fram bl a för att ersätta trasiga eller igenkalkade varmvattenberedare i villapannor. Dessa tappvattenautomater har visat sig kunna vara intressanta även för anslutning till ackumulatortankar. Konsumentverket gav SERC uppdraget att testa dessa nya automater för att se hur väl de fungerar i ackumulatorsystem. Vi har testat tre olika fabrikat: Alfajet, Cetetherm och Solvis. Cetetherm provades förutom i grundversionen med trevägsventil, även med en tvåvägsventil. Totalt testades således fyra olika konstruktioner, som skiljer sig i värmeväxlarstorlek och reglerstrategi. I rapporten visas driftsegenskaper och termiska prestanda för tappvattenautomaterna med hjälp av diagram, som upprättades efter omfattande mätningar. Tappvattenautomaterna, som i grundutförande var avsedda för värmepannor, är inte lämpliga för användning tillsammans med ackumulatortank. Tappvattenautomater med god termisk prestanda och till ackumulatorsystem anpassad reglerstrategi ger däremot gott resultat. Alfajet och Cetetherm med trevägsventil är mindre lämpade för ackumulatorvärme-system. En onödigt hög returtemperatur till ackumulatortanken leder till dålig skiktning vid urladdning och därigenom kan en mindre del av energiinnehållet i tanken tillgodogöras. Genom att ersätta trevägsventilen hos Cetetherm med en tvåvägsventil, förbättras den termiska funktionen vid användning med ackumulatortank. Solvis tappvattenautomat var från början konstruerad för solvärmesystem med ackumulatortank och visade sig ha god prestanda. Tappvattenautomaterna testades även med avseende på varmvattenkomforten vid flödesändringar. Ingen av tappvattenautomaterna visade sig kunna reglera varmvattentemperaturen lika bra som ett traditionellt system med väl fungerande blandningsventil. Tappvattenautomatens inverkan på ett solvärmesystems täckningsgrad under sommarhalvårets väderförhållanden testades i SERCs sexdagarstest. I jämförelse till de hittills bästa konventionella system med inbyggda värmeväxlare av typ kamflänsrör kunde täckningsgraden för ett i övrigt likvärdigt system höjas med upp till 15 procentenheter. Marknadspriset för tappvattenautomater på omkring 10 000 kr är fortfarande för högt, för att den skall kunna konkurrera med konventionella system. Vidareutvecklade förenklade system, som produceras i större serier kommer enligt vår bedömning att kunna erbjudas till lägre pris i framtiden.
Resumo:
An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.
Resumo:
Inom projektet provades 10 konfigurationer av samma ackumulatortank. Tankarna utsattes under kontrollerade förhållanden för en 6-dagars testcykel. Under testet tillfördes varje tank värme från en (simulerad) solfångare och, i den mån det behövdes, tillsatsvärme från elpatronen. Väderförhållanden under de sex dagarna var två fina, en växlande, två dåliga och ytterligare en växlande dag i nämnd följd. De flesta systemkonfigurationer klarade sig under de soliga dagarna utan energitillskott från elpatronen och förmådde dessutom att lagra värnlen så att även tappningar på följande dag med "växlande" väder kunde ske utan el-tillskott. De molniga dagarna behövde alla systemkonfigurationer el-tillskott. Solvärmesystemens täckningsgrad varierade mellan 36,5 % för det sämsta systemet till 70, 3 % för det bästa. En ackumulatortank med två seriekopplade tappvarmvattenvärmeväxIare (en i botten för förvärmning och en i tankens övre del för slutvärmning) ger betydligt bättre resultat än en tank med bara en enda sådan värmeväxlare. Tankens volym var i de utförda provningarna 750 liter, solfångarstorleken 10 m2 och lasten 13 kWh per dag. För dessa förutsättningar ger en yttre solvärmeväxlare inga mätbara fördelar gentemot en tillräcklig stor inbyggd värmeväxlare. De gjorda försöken visar, att alla tankkonfigurationerna visar dålig skiktning. Ett fortsatt arbete bör göras för att minska omblandningen i tanken vid både inladdning och uttag av värme.
Resumo:
Del 1:Innehållsförteckning och korta sammanfattningarDEL 2:Verksamhetsberättelsen för perioden maj 1992 till april 1993 beskriver de arbeten som har gjorts av villasolvärmegruppen på SERC efter den inledande studie (SERC/UCFB-91/0039), där villasolvärmesystem kartlades. Följande arbeten beskrivs:- Utveckling av lågflödessystem och internationella kontakter- Uppbyggnad av värmelaboratorium på SERC- Praktiska test av värmelagringsenheten- Praktiska test av nya systemkomponenter i solvärmekretsen- Datasimulering inkluderande nyutvecklade systemkomponenterI verksamhetsplanen beskrivs huvudmålet för de arbeten som ska utföras under trårsperioden 93 - 96. Mera detaljerat beskrivs de arbeten som ska utföras under budgetåret 1993/94:- Beräkningsprogram för nogrannare dimensionering av finrörsvärmeväxlare- Konstruktion av maskiner för värmeväxlartillverkning- Utveckling av värmeväxlare för tappvarmvatten- Simuleringsberäkningar för hela systemet med PRESIM/TRNSYS.DEL 3:Del 3 innehåller en redovisning av mätresultat för den undersökta kombitanken. Temperaturförloppen på olika höjd i tankens har studerats vid uppvärmning genom solvärmeväxlaren och nedkylning genom tappning av varmvatten. Resultaten diskuteras kvalitativt och redovisas kvantitativt i form av diagram. Mätresultaten på två prototyper av den på SERC utvecklade finrörsvärmeväxlaren redovisas och diskuteras i jämförelse till traditionell värmeväxlare. De erhållna mätresultaten används som ingångsvärden för simuleringsberäkningar med PRESIM/TRNSYS. Problemen med de i PRESIM/TRNSYS befintliga modellerna diskuteras. De utförda modellberäkningarna tillåter en uppskattning av möjliga förbättringar i form av höjd årsverkningsgrad för ett svenskt villasolvärmesystem med kombitank. I del 3 redovisas dessutom de mätningar som har utförts på otika pumpar vilka skulle kunna användas i solfångarkretsen. Sex olika pumpar analyseras och diskuteras. Del 3 har följande rubriker:- Beskrivning av den undersökta lagringstanken- Mätningar på tappvarmvattenväxlare- Mätningar på solvärmeväxlare (kamflänsrör och finrörsvärmeväxlare)- Simuleringsberäkningar- PumpmätningarDEL 4:Del 4 innehåller publicerade rapporter under 1992 och 93 samt patentansökan för SERC?s finrörsvärmeväxlare: - NORTH SUN 1992, Solar Energy at High Latitudes, June 24-26 1992 Trondheim, Norway. Domestic solar heating system - a systematic study i progress Patentansökan på finrorsvärmeväxlare till Patent- och Registreringsverket från 93 01 23. ISES SOLAR WORLD CONGRESS, 23-27 augusti 1993, Budapest, HUNGARY Criteria for cost efficient small scale solar hot water installations.DEL 5:Del 5 hänvisar till rapporterna från IEA Task-1 4 mötena om solfångarsystem i- Hameln, Tyskland, augusti 1992 och- Rom, Italien, januari 1993.I rapporterna beskrivs aktiviteten inom den internationella arbetsgruppen speciellt med hänsyn på utveckling av villasolvärmesystem. I Rom presenterades principlösningen för den på SERC utvecklade finrörsvärmeväxlare. De har publicerats separat som nr 42 och 46 i SERCs rapportserie.
Resumo:
During November and December 1992 I visited several groups involved with renewable energy, most of them dealing with education. These groups and their work are described briefly in this report. The groups in Melbourne, Australia have come a long way with education in this field and we have a lot to learn from them. Government funding is needed for large scale work, but useful work can still be done at the community level with much smaller budgets.