986 resultados para Background measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The prognostic relevance of the collateral circulation is still controversial. The goal of this study was to assess the impact on survival of quantitatively obtained, recruitable coronary collateral flow in patients with stable coronary artery disease during 10 years of follow-up. METHODS AND RESULTS: Eight-hundred forty-five individuals (age, 62+/-11 years), 106 patients without coronary artery disease and 739 patients with chronic stable coronary artery disease, underwent a total of 1053 quantitative, coronary pressure-derived collateral measurements between March 1996 and April 2006. All patients were prospectively included in a collateral flow index (CFI) database containing information on recruitable collateral flow parameters obtained during a 1-minute coronary balloon occlusion. CFI was calculated as follows: CFI = (P(occl) - CVP)/(P(ao) - CVP) where P(occl) is mean coronary occlusive pressure, P(ao) is mean aortic pressure, and CVP is central venous pressure. Patients were divided into groups with poorly developed (CFI < 0.25) or well-grown collateral vessels (CFI > or = 0.25). Follow-up information on the occurrence of all-cause mortality and major adverse cardiac events after study inclusion was collected. Cumulative 10-year survival rates in relation to all-cause deaths and cardiac deaths were 71% and 88%, respectively, in patients with low CFI and 89% and 97% in the group with high CFI (P=0.0395, P=0.0109). Through the use of Cox proportional hazards analysis, the following variables independently predicted elevated cardiac mortality: age, low CFI (as a continuous variable), and current smoking. CONCLUSIONS: A well-functioning coronary collateral circulation saves lives in patients with chronic stable coronary artery disease. Depending on the exact amount of collateral flow recruitable during a brief coronary occlusion, long-term cardiac mortality is reduced to one fourth compared with the situation without collateral supply.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Pericard 6 (P6) is one of the most frequently used acupuncture points, especially in preventing nausea and vomiting. At this point, the median nerve is located very superficially. OBJECTIVES: To investigate the distance between the needle tip and the median nerve during acupuncture at P6, we conducted a prospective observational ultrasound (US) imaging study. We tested the hypothesis that de qi (a sensation that is typical of acupuncture needling) is evoked when the needle comes into contact with the epineural tissue and thereby prevents nerve penetration. SETTINGS/LOCATION: The outpatient pain clinic of the Medical University of Vienna, Austria. SUBJECTS: Fifty (50) patients receiving acupuncture treatment including P6 bilaterally. INTERVENTIONS: Patients were examined at both forearms using US (a 10-MHz linear transducer) after insertion of the needle at P6. OUTCOME MEASURES: The distance between the needle tip and the median nerve, the number of nerve contacts and nerve penetrations, as well as the number of successfully elicited de qi sensations were recorded. RESULTS: Complete data could be obtained from 97 cases. The mean distance from the needle tip to the nerve was 1.8 mm (standard deviation 2.2; range 0-11.3). Nerve contacts were recorded in 52 cases, in 14 of which the nerve was penetrated by the needle. De qi was elicited in 85 cases. We found no association between the number of nerve contacts and de qi. The 1-week follow-up showed no complications or neurologic problems. CONCLUSIONS: This is the first investigation demonstrating the relationship between acupuncture needle placement and adjacent neural structures using US technology. The rate of median nerve penetrations by the acupuncture needle at P6 was surprisingly high, but these seemed to carry no risk of neurologic sequelae. De qi at P6 does not depend on median nerve contact, nor does it prevent median nerve penetration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Parathyroid hormone (PTH) and parathyroid hormone-related protein (PTH-rP) are two potent hypercalcemic hormones that act on the same targets. Autonomous secretion of the former is involved in primary hyperparathyroidism (PHPT), whereas the latter is responsible for humoral hypercalcemia of malignancy (HHM). Methods: From 250 consecutive, hypercalcemic serum samples sent to our laboratory for assessment of intact PTH, we were able to obtain clinical information, as well as an additional plasma sample for PTH-rP measurement, in 134 patients. At the time of sampling, patients could be classified into seven groups: cancer without known bone metastases (CaNoMeta, n=36), cancer with bone metastases (CaMeta, n=9), no evidence of cancer (noEvCa, n=71), sarcoidosis (Sarc, n=3), end-stage renal disease (ESRD, n=12), vitamin D overdose (VIT-D, n=2), and hyperthyroidism (Thyr, n=1). Results: In the CaNoMeta group, 29/36 patients had elevated PTH-rP levels, 9/36 patients had inappropriately elevated PTH levels, and 5/36 had elevated levels of both hormones. In the CaMeta group, three of the nine patients had inappropriately elevated PTH levels, two of them with concomitantly elevated PTH-rP levels. In the NoEvCa group, 63/71 patients had an inappropriate elevation of PTH levels and were diagnosed as having PHPT. Four of the 71 patients had elevated levels of both PTH and PTH-rP; three of them were in poor health and died within a short period of time. All of the ESRD patients had very high PTH and normal PTH-rP levels, except for one woman with high PTH-rP and undetectable PTH levels; she died from what later turned out to be a recurrent bladder carcinoma. In the Sarc, Vit-D, and Thyr groups, both PTH and PTH-rP levels were normal. Conclusions: (1) Elevated PTH-rP levels are a common finding in cancer patients without bone metastases. Intact PTH, however, should always be measured in hypercalcemic patients with malignancy because concurrent primary hyperparathyroidism is not rare. (2) Primary hyperparathyroidism accounts for hypercalcemia in 90% of patients without evidence of cancer whose PTH-rP levels may also be found to be elevated in a few cases, even some with surgically demonstrated parathyroid adenoma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The left superior temporal gyrus (STG) has been suggested to play a key role in auditory verbal hallucinations (AVH) in patients with schizophrenia. Methods: Eleven medicated subjects with schizophrenia and medication-resistant AVH and 19 healthy controls underwent perfusion magnetic resonance (MR) imaging with arterial spin labeling (ASL). Three additional repeated measurements were conducted in the patients. Patients underwent a treatment with transcranial magnetic stimulation (TMS) between the first 2 measurements. The main outcome measure was the pooled cerebral blood flow (CBF), which consisted of the regional CBF measurement in the left STG and the global CBF measurement in the whole brain. Results: Regional CBF in the left STG in patients was significantly higher compared to controls (p < 0.0001) and to the global CBF in patients (p < 0.004) at baseline. Regional CBF in the left STG remained significantly increased compared to the global CBF in patients across time (p < 0.0007), and it remained increased in patients after TMS compared to the baseline CBF in controls (p < 0.0001). After TMS, PANSS (p = 0.003) and PSYRATS (p = 0.01) scores decreased significantly in patients. Conclusions: This study demonstrated tonically increased regional CBF in the left STG in patients with schizophrenia and auditory hallucinations despite a decrease in symptoms after TMS. These findings were consistent with what has previously been termed a trait marker of AVH in schizophrenia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Quantitative myocardial PET perfusion imaging requires partial volume corrections. METHODS: Patients underwent ECG-gated, rest-dipyridamole, myocardial perfusion PET using Rb-82 decay corrected in Bq/cc for diastolic, systolic, and combined whole cycle ungated images. Diastolic partial volume correction relative to systole was determined from the systolic/diastolic activity ratio, systolic partial volume correction from phantom dimensions comparable to systolic LV wall thicknesses and whole heart cycle partial volume correction for ungated images from fractional systolic-diastolic duration for systolic and diastolic partial volume corrections. RESULTS: For 264 PET perfusion images from 159 patients (105 rest-stress image pairs, 54 individual rest or stress images), average resting diastolic partial volume correction relative to systole was 1.14 ± 0.04, independent of heart rate and within ±1.8% of stress images (1.16 ± 0.04). Diastolic partial volume corrections combined with those for phantom dimensions comparable to systolic LV wall thickness gave an average whole heart cycle partial volume correction for ungated images of 1.23 for Rb-82 compared to 1.14 if positron range were negligible as for F-18. CONCLUSION: Quantitative myocardial PET perfusion imaging requires partial volume correction, herein demonstrated clinically from systolic/diastolic absolute activity ratios combined with phantom data accounting for Rb-82 positron range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements are presented of differential cross-sections for top quark pair production in pp collisions at root s = 7 TeV relative to the total inclusive top quark pair production cross-section. A data sample of 2.05 fb(-1) recorded by the ATLAS detector at the Large Hadron Collider is used. Relative differential cross-sections are derived as a function of the invariant mass, the transverse momentum and the rapidity of the top quark pair system. Events are selected in the lepton (electron or muon) + jets channel. The background-subtracted differential distributions are corrected for detector effects, normalized to the total inclusive top quark pair production cross-section and compared to theoretical predictions. The measurement uncertainties range typically between 10 % and 20 % and are generally dominated by systematic effects. No significant deviations from the Standard Model expectations are observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Assessment of endothelial function of the microvasculature by peripheral arterial tonometry (EndoPAT(®)) has gained increasing popularity in patients with cardiovascular risk factors. Only limited knowledge about its reproducibility in patients with coronary artery disease (CAD) is available. We therefore aimed to quantify reproducibility of EndoPAT(®) parameters in patients with stable CAD. DESIGN EndoPAT(®) measurements were performed repeatedly in 78 male patients (age 66 ± 8 years) with CAD on stable medication. We calculated overall mean, standard deviation (SD), coefficient of variation (CV) and intraclass correlation coefficient (ICC) of the following parameters: reactive hyperemic index (RHI), PAT ratio of the postocclusion period 90-150 s as used for calculation of the RHI (PAT ratio90-150 s) and 90-120 s (PAT ratio90-120 s) as used for the often employed Framingham RHI (F-RHI), as well as PAT ratio of the peak hyperemic response (PAT ratiopeak response). Additionally, least significant changes (LSC) for individual subjects and minimum sample sizes for parallel and cross-over design studies were calculated. RESULTS Mean RHI was 1·84 (SD 0·36). For RHI, PAT ratio90-150 s , PAT ratio90-120 s , and PAT ratiopeak response the CVs were 17·0%, 25·4%, 26·1%, and 25·0%, respectively. The ICCs were 0·45, 0·49, 0·48 and 0·51, respectively, and LSC for RHI was 47·2%. CONCLUSIONS CV of RHI in our population was moderate; however, we consider this precision insufficient to monitor changes in individual patients, as they would need to exceed 47% to show a significant change. Further, the poor ICCs reflect the difficulty of detecting treatment effects in homogenous populations, such as patients with stable CAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sensitivity of the gas flow field to changes in different initial conditions has been studied for the case of a highly simplified cometary nucleus model. The nucleus model simulated a homogeneously outgassing sphere with a more active ring around an axis of symmetry. The varied initial conditions were the number density of the homogeneous region, the surface temperature, and the composition of the flow (varying amounts of H2O and CO2) from the active ring. The sensitivity analysis was performed using the Polynomial Chaos Expansion (PCE) method. Direct Simulation Monte Carlo (DSMC) was used for the flow, thereby allowing strong deviations from local thermal equilibrium. The PCE approach can be used to produce a sensitivity analysis with only four runs per modified input parameter and allows one to study and quantify non-linear responses of measurable parameters to linear changes in the input over a wide range. Hence the PCE allows one to obtain a functional relationship between the flow field properties at every point in the inner coma and the input conditions. It is for example shown that the velocity and the temperature of the background gas are not simply linear functions of the initial number density at the source. As probably expected, the main influence on the resulting flow field parameter is the corresponding initial parameter (i.e. the initial number density determines the background number density, the temperature of the surface determines the flow field temperature, etc.). However, the velocity of the flow field is also influenced by the surface temperature while the number density is not sensitive to the surface temperature at all in our model set-up. Another example is the change in the composition of the flow over the active area. Such changes can be seen in the velocity but again not in the number density. Although this study uses only a simple test case, we suggest that the approach, when applied to a real case in 3D, should assist in identifying the sensitivity of gas parameters measured in situ by, for example, the Rosetta spacecraft to the surface boundary conditions and vice versa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Acute mesenteric ischemia (AMI) is an emergency with a mortality rate up to 50 %. Detecting AMI continues to be a major challenge. This study assed the correlation of repeated preoperative serum lactate with bowel necrosis and to identify risk factors for a lethal outcome in patients with AMI. METHODS A retrospective study of 91 patients with clinically and pathologically confirmed AMI from January 2006 to December 2012 was performed. RESULTS In-hospital mortality rate was 42.9 %. Two hundred nine preoperative lactate measurements were analyzed (2.3 ± 1.1 values per patient). Less than or equal to six hours prior to surgery, the mean serum lactate level was significantly higher (4.97 ± 4.21 vs. 3.24 ± 3.05 mmol/L, p = 0.006) and the mean pH significantly lower (7.28 ± 0.12 vs. 7.37 ± 0.08, p = 0.001) compared to >6 h before surgery. Thirty-four patients had at least two lactate measurements within 24 h prior to surgery. In this subgroup, 17 patients (50 %) exhibited an increase, 17 patients (50 %) a decrease in lactate levels. Forward logistic regression analysis showed that length of necrotic bowel and the highest lactate value 24 h prior to surgery were independent risk factors for mortality (r (2)  = 0.329). CONCLUSION The value of serial lactate and pH measurements to predict the length of necrotic bowel is very limited. Length of necrotic bowel and lactate values are independent risk factors for mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to evaluate the accuracy of linear measurements on three imaging modalities: lateral cephalograms from a cephalometric machine with a 3 m source-to-mid-sagittal-plane distance (SMD), from a machine with 1.5 m SMD and 3D models from cone-beam computed tomography (CBCT) data. METHODS Twenty-one dry human skulls were used. Lateral cephalograms were taken, using two cephalometric devices: one with a 3 m SMD and one with a 1.5 m SMD. CBCT scans were taken by 3D Accuitomo® 170, and 3D surface models were created in Maxilim® software. Thirteen linear measurements were completed twice by two observers with a 4 week interval. Direct physical measurements by a digital calliper were defined as the gold standard. Statistical analysis was performed. RESULTS Nasion-Point A was significantly different from the gold standard in all methods. More statistically significant differences were found on the measurements of the 3 m SMD cephalograms in comparison to the other methods. Intra- and inter-observer agreement based on 3D measurements was slightly better than others. LIMITATIONS Dry human skulls without soft tissues were used. Therefore, the results have to be interpreted with caution, as they do not fully represent clinical conditions. CONCLUSIONS 3D measurements resulted in a better observer agreement. The accuracy of the measurements based on CBCT and 1.5 m SMD cephalogram was better than a 3 m SMD cephalogram. These findings demonstrated the linear measurements accuracy and reliability of 3D measurements based on CBCT data when compared to 2D techniques. Future studies should focus on the implementation of 3D cephalometry in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurements of the natural background radiation have been made at numerous places throughout the world. Very little work in this field has been done in developing countries. In Mexico the natural radiation to which the population is exposed has not been assessed. This dissertation represents a pioneer study in this environmental area. The radiation exposure which occupants within buildings receive as a result of naturally occurring radionuclides present in construction materials is the principal focus.^ Data were collected between August 1979 and November 1980. Continuous monitoring was done with TLDs placed on site for periods of 3 to 6 months. The instrumentation used for "real-time" measurements was a portable NaI (Tl) scintillation detector. In addition, radiometric measurements were performed on construction materials commonly used in Mexican homes.^ Based on TLD readings taken within 75 dwellings, the typical indoor exposure for a resident of the study area is 9.2 (mu)Rh('-1). The average reading of the 152 indoor scintillometer surveys was 9.5 (mu)Rh('-1), the outdoor reading 7.5 (mu)Rh('-1). Results of one-way and multi-way analyses of the exposure data to determine the effect due to building materials type, geologic subsoil, age of dwelling, and elevation are also presented. The results of 152 indoor scintillometer surveys are described. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Impact and monitoring of dredge spoils are an important environmental issue. This investigation aims to map two dredge-spoil dispersals in the Bay of Seine by using an innovative application of well-established environmental magnetic proxies. Low-field magnetic susceptibility measurements were performed on discrete samples from dredge sediments and from the Bay of Seine seafloor before & after dumping. The fingerprinting of the dispersion of dredge-dumped sediments is efficient due to the higher susceptibility of the dredge sediments with respect to the background. Besides, terrestrial input is also monitored in our susceptibility maps. Dilution of the susceptibility signal allows an estimation of the resilience of the sedimentary environment on a six-month survey. This susceptibility signal is controlled by the ferromagnetic fraction of the sediment. A constant magnetic mineralogy carried by magnetite is observed in the study area, thus a qualitative parameter for magnetic grain size was selected that shows an in-progress resilience pattern over the survey.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On 20 March 2015, a total solar eclipse occurred over Ny-Ålesund (78.9° N, 11.9° E), Svalbard, in the high Arctic. It was the first time that the surface radiation components during the totality of a solar eclipse were measured by a Baseline Surface Radiation Network (BSRN) station. With the Ny-Ålesund long-term radiation data set as background (available at doi:10.1594/PANGAEA.150000), we present here the peculiarities of the radiation components and basic meteorology observed during the eclipse event. The supplementary data set contains the basic BSRN radiation and surface meteorological data in 1 min resolution for March 2015, and is available at doi:10.1594/PANGAEA.854326. The eclipse radiation data will be a useful auxiliary data set for further studies on micrometeorological surface-atmosphere exchange processes in the Svalbard environment, and may serve as a test case for radiative transfer studies.