976 resultados para BATCH INJECTION ANALYSIS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, economic and sensitive chemiluminescent method involving flow-injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow-injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1–50 µg/mL. In addition, a sample throughput of 85 samples/h is possible. Copyright © 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new electrocatalytic active porphyrin nanocomposite material was obtained by electropolymerization of meso-tetra(4-sulphonatephenyl) porphyrinate manganese(III) complex (MnTPPS) in alkaline solutions containing sub-micromolar concentrations of silver chloride. The modified glassy carbon electrodes efficiently oxidize hydrazine at 10 mV versus Ag/AgCl, dramatically decreasing the overpotential of conventional carbon electrodes. The analytical characteristics of this amperometric sensor coupled with batch injection analysis (BIA) technique were explored. Wide linear dynamic range (2.5 x 10(-7) to 2.5 x 10(-4) mol L-1), good repeatability (R.S.D. = 0.84%, n = 30) and low detection (3.1 x 10(-8) mol L-1) and quantification (1.0 x 10(-7) mol L-1) limits, as well as very fast sampling frequency (60 determinations per hour) were achieved. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudos com eletrodos modificados foram conduzidos utilizando dois sistemas porfirínicos supramoleculares diferentes. O primeiro foi baseado na modificação de eletrodo de carbono vítreo com uma porfirina de níquel tetrarrutenada, [NiIITPyP{RuII(bipy)2Cl}4]4+. A modificação do eletrodo foi realizada por meio de sucessivos ciclos voltamétricos em meio alcalino (pH 13), gerando um eletrodo com característica similar a eletrodos modificados com α-Ni(OH)2. A caracterização química do filme formado foi realizada através das técnicas de voltametria cíclica, ressonância paramagnética eletrônica, espectroscopia eletrônica por reflectância e espectroscopia Raman com ensaio espectro-eletroquímico. Os resultados sugerem a formação de um polímero de coordenação, [µ-O2-NiIITPyP{RuII(bipy)2Cl}4]n, composto por subunidades porfirínicas ligadas entre si por pontes µ-peroxo axialmente coordenadas aos átomos de níquel (Ni-O-O-Ni). O crescimento do filme apresentou dependência da alcalinidade do meio pela formação do precursor octaédrico [Ni(OH)2TRPyP]2+ em solução, pela coordenação de OH- nas posições axiais do átomo de níquel. O processo de eletropolimerização indicou a participação de radical hidroxil, gerado por oxidação eletrocatalítica da água nos sítios periféricos da porfirina contendo o complexo de rutênio. O mesmo eletrodo foi aplicado como sensor eletroquímico para análise amperométrica de ácido fólico em comprimidos farmacêuticos. O sensor foi associado a um sistema de Batch Injection Analysis (BIA) alcançando considerável rapidez e baixo limite de detecção. Para as análises das amostras também foi proposto um método para a remoção da lactose, que agia como interferente. O segundo estudo envolveu a modificação de eletrodos de carbono vítreo com diferentes hemoglobinas, naturais (HbA0, HbA2 e HbS) e sintéticas (Hb-PEG5K2, αα-Hb-PEG5K2 e BT-PEG5K4), para a avaliação da eficiência na redução eletrocatalítica de nitrito mediada por FeI-heme. Os filmes foram produzidos pela mistura de soluções das hemoglobinas com brometo de didodecildimetiltrimetilamônio (DDAB), aplicados nas superfícies com consecutiva evaporação, formando filmes estáveis. Os valores de potencial redox para os processos do grupo heme e a sua associação com a disponibilidade do grupo na proteína foram avaliados por voltametria cíclica. Os valores das constantes de velocidade, k, para redução de nitrito foram obtidos por cronoamperometria em -1,1 V (vs Ag/AgCl(KCl 3M)) que foram utilizados para estudo comparativo entre as espécies sintéticas para eventual aplicação clínica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An amperometric FIA method for nitrite quantification based on nitrite electroreduction and employing a carbon paste electrode (CPE) chemically modified with iron hexacyanoferrate (HCF) as an amperometric detector was developed. The influence of experimental conditions on the preparation of the electrode materials was evaluated and the materials obtained in each study were used for the development of modified electrodes. The electrochemical sensors were prepared by a fast, simple, and inexpensive procedure, and the long-term performance of the electrodes were quite satisfactory as the stability was maintained over one year. HCF was an effective redox mediator for nitrite electroreduction in acidic media, allowing nitrite detection at +0.2 V vs. Ag/AgClsat, which is a potential free of possible interfering species that are normally present in food and water samples. The electrochemical cell used in the FIA system was similar to a batch injection analysis cell, enabling recirculation of the carrier solution. This is an attractive feature because it allows the use of a high flow rate (6 mL min-1) leading to high sensitivity and analysis speed, while keeping reagent consumption low. The proposed method had a detection limit of 9 μmol L-1 and was successfully employed for nitrite quantification in spiked water and sausage samples. The obtained results were in good agreement with those provided by the spectrophotometric official method. At a 95 % confidence level it was not observed statistical differences neither in nitrite content nor in the precision provided by both methods. The experimental conditions for the synthesis of HCF were optimized and the best electrode material was prepared by mixing FeCl3, K4[Fe(CN)6] and carbon powder subjected to an acid and thermal treatment (400 ºC), followed by ultrasonic agitation at 4 °C. This material was used to construct an electrode with improved analytical performance to reduce nitrite, which presented greater stability compared to HCF film electrodeposited on the EPC, showing that the preparation procedure of the electrode material is an effective strategy for the development of HCF modified electrodes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper explores a new source of graphite for working electrodes, which presents advantages such as low electrical resistance, good flexibility, favorable mechanical performance, versatility to design electrodes in almost any size and very low cost. The new electrodes were investigated in batch electrochemical cells as associated with flow injection analysis systems. Cyclic voltammetry, stripping voltammetry, and amperometry associated with flow injection analysis techniques were applied for the determination of ascorbic acid, zinc and paracetamol in pharmaceutical formulations, respectively. Well-established analytical methods were applied for comparison purposes. The results herein demonstrate the potential of graphite foils as working electrodes in different electroanalytical methods, offering the possibility of producing disposable sensors for routine applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Measurement of iron and manganese is very important in evaluating the quality of natural waters. We have constructed an automated Fe(II), total dissolved iron(TDI), Mn(II), and total dissolved manganese(TDM) analysis system for the quality control of underground drinking water by reverse flow injection analysis and chemiluminescence detection(rFIA-CL), The method is based on the measurement of the metal-catalyzed light emission from luminol oxidation by potassium periodate. The typical signal is a narrow peak, in which the height is proportional to light emitted and hence to the concentration of metal ions. The detection limits were 3 x 10(-6) mu g ml(-1) for Fe(II) and the linear range extents up to 1.0 x 10(-4) and 5 x 10(-6) mu g ml(-1) for Mn(II) cover a linear range to 1.0 x 10(-4) mu g ml(-1). This method was used for automated in-situ monitoring of total dissolved iron and total dissolved in underground water during water treatment. (C) 1997 Elsevier Science B.V.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thionine-containing chemically modified electrode (cme) was constructed with glassy carbon substrate by potential sweep oxidation, electrodeposition and adsorption procedures, and electrocatalytic reduction of hemoglobin was carried out and characterized at the cme under batch and flow conditions. Comparison of the catalytic response toward hemoglobir obtained at the cme was made mainly in terms of the potential dependence, the detectability and long-term stability. When used in flow injection analysis (FIA) experiments with the detector monitored at a constant potential applied at -0.35 V vs sce, detection limit of 0.15-1.5 pmol level of hemoglobin injected was achieved at the cme, with linear response range over 2 orders of magnitude. All the cme s retained more than 70% of their initial hemoglobin response level over 8 h of continuous service in the flow-through system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A Prussian Blue-modified glassy carbon electrode prepared by simple adsorption exhibited excellent electrocatalytic activity in the oxidation of hydrazine in acidic media. A film of the perfluorosulphonic acid polymer Nafion coated on top of the Prussian Blue-modified glassy carbon electrode can improve the mechanical stability of the Prussian Blue layer in the flow stream. Hydrazine was detected by flow-injection analysis at the modified electrode with high sensitivity. The limit of detection was 0.6 ng.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel Eastman-AQ/Ni(II) chemically modified electrode (CME) produced by "double coating step" deposition of a poly(ester sulphonic acid) polymer film and Ni2+-containing crystalline species onto glassy carbon instead of a metallic nickel electrode exhibited stable electrocatalytic oxidation of numerous alpha-hydrogen compounds including carbohydrates, amines and amino acids. In cyclic voltammetry, the electrocatalysis appeared with an irreversible anodic wave at +0.55 V (vs. Ag/AgCl). The CME was adapted for constant-potential amperometric detection of these compounds in flow injection analysis. Using the CME, the linear response concentration range was between 1.0 x 10(-5) and 5.0 x 10(-2) mol/l and the detection limit was 5.0 x 10(-6) mol/l for glucose. The stability of the CME was adequate for routine quantitative application.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fluvoxamine (FVX) can be reduced at a mercury- drop electrode, with a maximum peak current intensity being obtained at a potential of -0.7 V vs. Ag/ AgCl, in an aqueous electrolyte solution of pH 2. The compound was determined in a pharmaceutical product and in spiked human serum by square-wave adsorptivestripping voltammetry (SWAdSV) after accumulation at the electrode surface, under batch conditions. Because the presence of dissolved oxygen did not interfere significantly with the analysis, it was also possible to determine FVX in the pharmaceutical product by use of a flow-injection analysis (FIA) system with SWAdSV detection. The methods developed were validated and successfully applied to the quantification of FVX in a pharmaceutical product. Recoveries between 76 and 89% were obtained in serum analysis. The FIA– SWAdSV method enabled analysis of up to 120 samples per hour at reduced cost, implying the possibility of competing with the chromatographic methods usually used for this analysis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coupling a liquid core waveguide cell to a sequential injection chromatograph improved the detection limits for determination of triazine herbicides without compromising peak resolution. Separation of simazine, atrazine, and propazine was achieved in water samples by a 25mm long C18 monolithic column. Detection was made at 238nm using a type II LCW (silica capillary coated with Teflon (R) AF2400) cell with 100cm of optical path length. Detection limits for simazine, atrazine, and propazine were 2.3, 1.9, and 4.5 mu g L-1, respectively. Reduced analysis time and low solvent consumption are other remarkable features of the proposed method.