987 resultados para Atrophic maxilla - Fixed prosthesis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim To compare the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) in an absorbable collagen sponge carrier (ACS) with autogenous bone graft for augmentation of the edentulous atrophic anterior maxilla. Methods Twenty-four subjects were enrolled in a randomized, controlled, parallel-group, open-label clinical trial. Subjects either received rhBMP-2/ACS (1.5 mg/ml) or particulated autogenous bone harvested from the mandibular retromolar region. A titanium-mesh was used to provide space and wound stability. A guide was used to standardize clinical recordings using an analogue caliper. Alveolar ridge width was also assessed using cone-beam computed tomography. Results rhBMP-2/ACS yielded significantly greater radiographic horizontal bone gain compared with autogenous bone graft at immediate subcrestal levels (1.5 ± 0.7 versus 0.5 ± 0.9 mm; p = 0.01); non-significant differences were observed at mid- (2.9 ± 0.8 versus 2.9 ± 0.9 mm; p = 0.98) and apical (1.7 ± 0.9 versus 1.8 ± 1.1 mm; p = 0.85) crestal levels. No significant differences in clinical horizontal bone gain were observed at 6 months between rhBMP-2/ACS and autogenous bone graft (3.2 ± 0.9 mm versus 3.7 ± 1.4 mm; p = 0.31). Sixty-two implants were placed after 6 month of healing with no significant differences between groups for number of implants, implant size, primary stability and survival. Conclusions rhBMP-2/ACS appears a realistic alternative for augmentation of the edentulous atrophic anterior maxilla. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The calvarial bone is highlighted as a good donor area for large reconstructions of atrophic jaw for subsequent rehabilitation with implant-supported prosthesis. The aim of this study was to observe and measure through histological and histometric evaluation, the cellular events that occur at the interface of union from onlay parietal bone graft on the maxilla of 10 patients, after a period of 6 months of incorporation. The biopsies were performed at the time of installation of osseointegrated implants. The bone contact area represented 78.75% and connective contact 21.25%. The region of connective union between the bone graft to the maxillae presented new bone formation (41.26%), marrow bone (36.06%), osteoid tissue (15.86%) and connective tissue (6.80%). All samples had good graft incorporation to the receptor bed with osteogenic activity and absence of inflammatory cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment.Objective: The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants.Materials and methods: The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system.Conclusion: The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fabrication of an interim prosthesis is an important procedure in oral rehabilitation because it aids in determining the esthetics, phonetics, and occlusal relationship of the definitive restoration. The typical material (acrylic resin) used in interim prostheses commonly fails due to fractures. During extended oral rehabilitation with fixed partial prostheses, high strength interim prostheses are often required to protect hard and soft tissues, avoid dental mobility, and to allow the clinician and patient a chance to evaluate cosmetics and function before the placement of the definitive prosthesis. Furthermore, a satisfactory interim prosthesis can serve as a template for the construction of the definitive prosthesis. The maintenance of this prosthesis is important during treatment for protection of teeth and occlusal stability. Procedures to reinforce interim prostheses help to improve performance and esthetics in long-term treatment. Due to the low durability of acrylic resin in long-term use, the use of reinforcing materials, such as metal castings or spot-welded stainless steel matrix bands, is indicated in cases of extensive restoration and long-term treatment. This paper describes an easy technique for fabricating a fixed interim prosthesis using acrylic resin and a cast metallic reinforcement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This clinical report describes a method to reduce the number of clinical sessions for the rehabilitation of implant-supported fixed dentures through a simplified and versatile procedure indicated mainly for immediate loading. According to this method, the immediate implant-supported fixed dentures for edentulous patients can be safely fabricated within 2 days. In this technique, the teeth in the wax are prepared on a base of light-polymerized resin, and both wax teeth and metallic superstructure trials are accomplished at the same session.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this in vitro study was to compare the dimensional accuracy of a stone index and of 3 impression techniques (tapered impression copings, squared impression copings, and squared impression copings splinted with acrylic resin) associated with 3 pouring techniques (conventional, pouring using latex tubes fitted onto analogs, and pouring after joining the analogs with acrylic resin) for implant-supported prostheses. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutment analogs, a framework, and 2 aluminum custom trays were fabricated. Polyether impression material was used for all impressions. Ten groups were formed (a control group and 9 test groups formed by combining each pouring technique and impression technique). Five casts were made per group for a total of 50 casts and 200 gap values (1 gap value for each implant-abutment analog). Results: The mean gap value with the index technique was 27.07 mu m. With the conventional pouring technique, the mean gap values were 116.97 mu m for the tapered group, 5784 mu m for the squared group, and 73.17 mu m for the squared splinted group. With pouring using latex tubes, the mean gap values were 65.69 mu m for the tapered group, 38.03 mu m for the squared group, and 82.47 mu m for the squared splinted group. With pouring after joining the analogs with acrylic resin, the mean gap values were 141.12 jum for the tapered group, 74.19 mu m for the squared group, and 104.67 mu m for the squared splinted group. No significant difference was detected among Index, squarellatex techniques, and master cast (P > .05). Conclusions: The most accurate impression technique utilized squared copings. The most accurate pouring technique for making the impression with tapered or squared copings utilized latex tubes. The pouring did not influence the accuracy of the stone casts when using splinted squared impression copings. Either the index technique or the use of squared coping combined with the latex-tube pouring technique are preferred methods for making implant-supported fixed restorations with dimensional accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals.Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants.Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations.Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.