888 resultados para Assurance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

L. Blot, A. Davis, M. Holubinka, R. Marti and R. Zwiggelaar, 'Automated quality assurance applied to mammographic imaging', EURASIP Journal of Applied Signal Processing 2002 (7), 736-745 (2002)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We survey several of the research efforts pursued by the iBench and snBench projects in the CS Department at Boston University over the last half dozen years. These activities use ideas and methodologies inspired by recent developments in other parts of computer science -- particularly in formal methods and in the foundations of programming languages -- but now specifically applied to the certification of safety-critical networking systems. This is research jointly led by Azer Bestavros and Assaf Kfoury with the participation of Adam Bradley, Andrei Lapets, and Michael Ocean.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this Quality Assurance Handbook (QAH) is to present and describe quality standards and procedures to be applied in the internal management and execution of the Research and Innovation Action 644187 RAGE (Realising and Applied Gaming Eco-system). This document is based on the terms and conditions established in the Grant Agreement (nº 644187) signed by the European Commission and the project coordinator, and its Annexes as well as the RAGE Consortium Agreement specifications and requirements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technological approach in the analysis and forensic interpretation of Total Hydrocarbons in soils and waters using 2D Gas Chromatography method (GC-GC) was developed alongside environmental forensic and the assessment models to provide better customer products for the environmental industry.
The objective was to develop an analytical methodology for TPH CWG. Raw data from this method is then to be evaluated for forensic interpretation and risk assessment modelling. Access will be made available to the expertise in methods of forensic tracing contaminant sources, transport modelling, human health risk modelling and detailed quantitative risk assessment.
The quantification of internal standards was key to the development of this method. As the laboratory does not test for TPH in 1D, it was requested during INAB ISO 17025 audit to individually map out where each compound falls chromatographically in the 2D. This was done through comparing carbon equivalent numbers to the n-alkane carbons. This proved e.g. 2-methylnaphthalene has 11 carbons in its structure; its carbon equivalent is 12.84 , the result of which falls within the band of Aromatic eC12-eC16 as opposed to expected eC10-eC12. This was carried out for all 16 PAH (polyaromatic hydrocarbons) and BTEX (benzene, toluene, ethylbenzene and o, m and p-xylenes). The n-alkanes were also assigned to their corresponding aliphatic bands e.g. nC8 would be expected to be in nC8-nC10.
The method was validated through a designated systematic experimental protocol and was challenged with spikes of known concentration of hydrocarbon parameters such as recoveries, precision, bias and linearity. The method was verified by testing a certified reference material which was used as a proficiency round of testing for numerous laboratories.
It is hoped that the method will be used in conjunction with the analysis through Bonn Agreement with their OSINet group. This is a panel of experts and laboratories (including CLS) who forensically identify oil spill contamination from a water source.
This method can prove itself to be a robust method and benefit the industry for contaminated land and water but the method needs to be seen as separate from the regular 1D chromatography. It will help identify contaminants and assist consultants, regulators, clients and scientists valuable information not seen in 1D

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To provide a tool to enable gamma analysis software algorithms to be included in a quality assurance (QA) program.

METHODS: Four image sets were created comprising two geometric images to independently test the distance to agreement (DTA) and dose difference (DD) elements of the gamma algorithm, a clinical step and shoot IMRT field and a clinical VMAT arc. The images were analysed using global and local gamma analysis with 2 in-house and 8 commercially available software encompassing 15 software versions. The effect of image resolution on gamma pass rates was also investigated.

RESULTS: All but one software accurately calculated the gamma passing rate for the geometric images. Variation in global gamma passing rates of 1% at 3%/3mm and over 2% at 1%/1mm was measured between software and software versions with analysis of appropriately sampled images.

CONCLUSION: This study provides a suite of test images and the gamma pass rates achieved for a selection of commercially available software. This image suite will enable validation of gamma analysis software within a QA program and provide a frame of reference by which to compare results reported in the literature from various manufacturers and software versions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present Working Project aims at studying the topic of assurance mapping in a specific organizational context of a Portuguese retail company. For this purpose, an assurance map framework was designed to support the decision making process of stakeholders, through the delivery of comfort concerning risks, operations and control. In the end, the framework was successfully implemented for the process sourcing of goods in two business units of the company. Although, further implementation of the framework proved not to be feasible during the project’s timespan, it is expected to occur in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: EORTC trial 22991 was designed to evaluate the addition of concomitant and adjuvant short-term hormonal treatments to curative radiotherapy in terms of disease-free survival for patients with intermediate risk localized prostate cancer. In order to assess the compliance to the 3D conformal radiotherapy protocol guidelines, all participating centres were requested to participate in a dummy run procedure. An individual case review was performed for the largest recruiting centres as well. MATERIALS AND METHODS: CT-data of an eligible prostate cancer patient were sent to 30 centres including a description of the clinical case. The investigator was requested to delineate the volumes of interest and to perform treatment planning according to the protocol. Thereafter, the investigators of the 12 most actively recruiting centres were requested to provide data on five randomly selected patients for an individual case review. RESULTS: Volume delineation varied significantly between investigators. Dose constraints for organs at risk (rectum, bladder, hips) were difficult to meet. In the individual case review, no major protocol deviations were observed, but a number of dose reporting problems were documented for centres using IMRT. CONCLUSIONS: Overall, results of this quality assurance program were satisfactory. The efficacy of the combination of a dummy run procedure with an individual case review is confirmed in this study, as none of the evaluated patient files harboured a major protocol deviation. Quality assurance remains a very important tool in radiotherapy to increase the reliability of the trial results. Special attention should be given when designing quality assurance programs for more complex irradiation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le projet "prestations de l'assurance-maladie sociale" est l'un des projets partiels élaborés par l'Office fédéral des assurances sociales (OFAS) dans le cadre de l'analyse des effets de la LAMal. Deux approches complémentaires sont adoptées pour répondre à la question du caractère suffisant du "catalogue" suisse des prestations à charge de l'assurance-maladie sociale: d'une part, la comparaison des "catalogues" des prestations remboursées en Suisse et à l'étranger et, d'autre part, l'examen de la couverture par le "catalogue" des prestations de problèmes de santé utilisés comme traceurs. [Table des matières] 1.1. Contexte. 1.2. Définition et limites du mandat. 1.3. Le "catalogue" des prestations : composition actuelle, participation d'autres assurances sociales et des pouvoirs publics. 1.4. Approches méthodologiques : comparaison internationale, étude de conditions-traceurs. 2. Analyse par comparaison internationale. 2.1. Recherche de documentation et collaborations. 2.2. Résultats : Suisse, France, Allemagne, Israël, Pays-Bas, Luxembourg, comparaison internationale des prestations générales, par catégorie, et des prestations spéciales. 3. Analyse par conditions traceurs. 3.1. Stratégie de la recherche documentaire. 3.2. Critères de choix des documents. 3.3. Variations méthodologiques et particularités. 3.4. Résultats : Accident vasculaire cérébral (ischémique), fracture de hanche, obésité, leucémie aigüe (LA), grossesse normale et nouveau-né en bonne santé. 3.5. Discussion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The level of information provided by ink evidence to the criminal and civil justice system is limited. The limitations arise from the weakness of the interpretative framework currently used, as proposed in the ASTM 1422-05 and 1789-04 on ink analysis. It is proposed to use the likelihood ratio from the Bayes theorem to interpret ink evidence. Unfortunately, when considering the analytical practices, as defined in the ASTM standards on ink analysis, it appears that current ink analytical practices do not allow for the level of reproducibility and accuracy required by a probabilistic framework. Such framework relies on the evaluation of the statistics of the ink characteristics using an ink reference database and the objective measurement of similarities between ink samples. A complete research programme was designed to (a) develop a standard methodology for analysing ink samples in a more reproducible way, (b) comparing automatically and objectively ink samples and (c) evaluate the proposed methodology in a forensic context. This report focuses on the first of the three stages. A calibration process, based on a standard dye ladder, is proposed to improve the reproducibility of ink analysis by HPTLC, when these inks are analysed at different times and/or by different examiners. The impact of this process on the variability between the repetitive analyses of ink samples in various conditions is studied. The results show significant improvements in the reproducibility of ink analysis compared to traditional calibration methods.