984 resultados para Assessment of accuracy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Short-term memory (STM) impairments are prevalent in adults with acquired brain injuries. While there are several published tests to assess these impairments, the majority require speech production, e.g. digit span (Wechsler, 1987). This feature may make them unsuitable for people with aphasia and motor speech disorders because of word finding difficulties and speech demands respectively. If patients perceive the speech demands of the test to be high, the may not engage with testing. Furthermore, existing STM tests are mainly ‘pen-and-paper’ tests, which can jeopardise accuracy. To address these shortcomings, we designed and standardised a novel computerised test that does not require speech output and because of the computerised delivery it would enable clinicians identify STM impairments with greater precision than current tests. The matching listening span tasks, similar to the non-normed PALPA 13 (Kay, Lesser & Coltheart, 1992) is used to test short-term memory for serial order of spoken items. Sequences of digits are presented in pairs. The person hears the first sequence, followed by the second sequence and s/he decides whether the two sequences are the same or different. In the computerised test, the sequences are presented in live voice recordings on a portable computer through a software application (Molero Martin, Laird, Hwang & Salis 2013). We collected normative data from healthy older adults (N=22-24) using digits, real words (one- and two-syllables) and non-words (one- and two- syllables). Their performance was scored following two systems. The Highest Span system was the highest span length (e.g. 2-8) at which a participant correctly responded to over 7 out of 10 trials at the highest sequence length. Test re-test reliability was also tested in a subgroup of participants. The test will be available as free of charge for clinicians and researchers to use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the development and evaluation of a method for enabling quantitative and automatic scoring of alternating tapping performance of patients with Parkinson’s disease (PD). Ten healthy elderly subjects and 95 patients in different clinical stages of PD have utilized a touch-pad handheld computer to perform alternate tapping tests in their home environments. First, a neurologist used a web-based system to visually assess impairments in four tapping dimensions (‘speed’, ‘accuracy’, ‘fatigue’ and ‘arrhythmia’) and a global tapping severity (GTS). Second, tapping signals were processed with time series analysis and statistical methods to derive 24 quantitative parameters. Third, principal component analysis was used to reduce the dimensions of these parameters and to obtain scores for the four dimensions. Finally, a logistic regression classifier was trained using a 10-fold stratified cross-validation to map the reduced parameters to the corresponding visually assessed GTS scores. Results showed that the computed scores correlated well to visually assessed scores and were significantly different across Unified Parkinson’s Disease Rating Scale scores of upper limb motor performance. In addition, they had good internal consistency, had good ability to discriminate between healthy elderly and patients in different disease stages, had good sensitivity to treatment interventions and could reflect the natural disease progression over time. In conclusion, the automatic method can be useful to objectively assess the tapping performance of PD patients and can be included in telemedicine tools for remote monitoring of tapping.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To develop a method for objective quantification of PD motor symptoms related to Off episodes and peak dose dyskinesias, using spiral data gathered by using a touch screen telemetry device. The aim was to objectively characterize predominant motor phenotypes (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Background: A retrospective analysis was conducted on recordings from 65 patients with advanced idiopathic PD from nine different clinics in Sweden, recruited from January 2006 until August 2010. In addition to the patient group, 10 healthy elderly subjects were recruited. Upper limb movement data were collected using a touch screen telemetry device from home environments of the subjects. Measurements with the device were performed four times per day during week-long test periods. On each test occasion, the subjects were asked to trace pre-drawn Archimedean spirals, using the dominant hand. The pre-drawn spiral was shown on the screen of the device. The spiral test was repeated three times per test occasion and they were instructed to complete it within 10 seconds. The device had a sampling rate of 10Hz and measured both position and time-stamps (in milliseconds) of the pen tip. Methods: Four independent raters (FB, DH, AJ and DN) used a web interface that animated the spiral drawings and allowed them to observe different kinematic features during the drawing process and to rate task performance. Initially, a number of kinematic features were assessed including ‘impairment’, ‘speed’, ‘irregularity’ and ‘hesitation’ followed by marking the predominant motor phenotype on a 3-category scale: tremor, bradykinesia and/or choreatic dyskinesia. There were only 2 test occasions for which all the four raters either classified them as tremor or could not identify the motor phenotype. Therefore, the two main motor phenotype categories were bradykinesia and dyskinesia. ‘Impairment’ was rated on a scale from 0 (no impairment) to 10 (extremely severe) whereas ‘speed’, ‘irregularity’ and ‘hesitation’ were rated on a scale from 0 (normal) to 4 (extremely severe). The proposed data-driven method consisted of the following steps. Initially, 28 spatiotemporal features were extracted from the time series signals before being presented to a Multilayer Perceptron (MLP) classifier. The features were based on different kinematic quantities of spirals including radius, angle, speed and velocity with the aim of measuring the severity of involuntary symptoms and discriminate between PD-specific (bradykinesia) and/or treatment-induced symptoms (dyskinesia). A Principal Component Analysis was applied on the features to reduce their dimensions where 4 relevant principal components (PCs) were retained and used as inputs to the MLP classifier. Finally, the MLP classifier mapped these components to the corresponding visually assessed motor phenotype scores for automating the process of scoring the bradykinesia and dyskinesia in PD patients whilst they draw spirals using the touch screen device. For motor phenotype (bradykinesia vs. dyskinesia) classification, the stratified 10-fold cross validation technique was employed. Results: There were good agreements between the four raters when rating the individual kinematic features with intra-class correlation coefficient (ICC) of 0.88 for ‘impairment’, 0.74 for ‘speed’, 0.70 for ‘irregularity’, and moderate agreements when rating ‘hesitation’ with an ICC of 0.49. When assessing the two main motor phenotype categories (bradykinesia or dyskinesia) in animated spirals the agreements between the four raters ranged from fair to moderate. There were good correlations between mean ratings of the four raters on individual kinematic features and computed scores. The MLP classifier classified the motor phenotype that is bradykinesia or dyskinesia with an accuracy of 85% in relation to visual classifications of the four movement disorder specialists. The test-retest reliability of the four PCs across the three spiral test trials was good with Cronbach’s Alpha coefficients of 0.80, 0.82, 0.54 and 0.49, respectively. These results indicate that the computed scores are stable and consistent over time. Significant differences were found between the two groups (patients and healthy elderly subjects) in all the PCs, except for the PC3. Conclusions: The proposed method automatically assessed the severity of unwanted symptoms and could reasonably well discriminate between PD-specific and/or treatment-induced motor symptoms, in relation to visual assessments of movement disorder specialists. The objective assessments could provide a time-effect summary score that could be useful for improving decision-making during symptom evaluation of individualized treatment when the goal is to maximize functional On time for patients while minimizing their Off episodes and troublesome dyskinesias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A challenge for the clinical management of advanced Parkinson’s disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sheet forming industry is plagued by inherent variations in its many input variables, making quality control and improvements a major hurdle. This is particularly poignant for Advanced High Strength Steels (AHSS), which exhibit a large degree of property variability. Current FE-based simulation packages are successful at predicting the manufacturability of a particular sheet metal components, however, due to their numerical deterministic nature are inherently unable to predict the performance of a real-life production process. Though they are now beginning to incorporate the stochastic nature of production in their codes. This work investigates the accuracy and precision of a current stochastic simulation package, AutoForm Sigma v4.1, by developing an experimental data set where all main sources of variation are captured through precise measurements and standard tensile tests. Using a Dual Phase 600Mpa grade steel a series of semi-cylindrical channels are formed at two Blank Holder Pressure levels where the response metric is the variation in springback determined by the flange angle. The process is replicated in AutoForm Sigma and an assessment of accuracy and precision of the predictions are performed. Results indicate a very good correspondence to the experimental trials, with mean springback response predicted to within 1 ° of the flange angle and the interquartile spread of results to within 0.22°.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Urban Sustainability expresses the level of conservation of a city while living a town or consuming its urban resources, but the measurement of urban sustainability depends on what are considered important indicators of conservation besides the permitted levels of consumption in accordance with adopted criteria. This criterion should have common factors that are shared for all the members tested or cities to be evaluated as in this particular case for Abu Dhabi, but also have specific factors that are related to the geographic place, community and culture, that is the measures of urban sustainability specific to a middle east climate, community and culture where GIS Vector and Raster analysis have a role or add a value in urban sustainability measurements or grading are considered herein. Scenarios were tested using various GIS data types to replicate urban history (ten years period), current status and expected future of Abu Dhabi City setting factors to climate, community needs and culture. The useful Vector or Raster GIS data sets that are related to every scenario where selected and analysed in the sense of how and how much it can benefit the urban sustainability ranking in quantity and quality tests, this besides assessing the suitable data nature, type and format, the important topology rules to be considered, the useful attributes to be added, the relationships which should be maintained between data types of a geo- database, and specify its usage in a specific scenario test, then setting weights to each and every data type representing some elements of a phenomenon related to urban suitability factor. The results of assessing the role of GIS analysis provided data collection specifications such as the measures of accuracy reliable to a certain type of GIS functional analysis used in an urban sustainability ranking scenario tests. This paper reflects the prior results of the research that is conducted to test the multidiscipline evaluation of urban sustainability using different indicator metrics, that implement vector GIS Analysis and Raster GIS analysis as basic tools to assist the evaluation and increase of its reliability besides assessing and decomposing it, after which a hypothetical implementation of the chosen evaluation model represented by various scenarios was implemented on the planned urban sustainability factors for a certain period of time to appraise the expected future grade of urban sustainability and come out with advises associated with scenarios for assuring gap filling and relative high urban future sustainability. The results this paper is reflecting are concentrating on the elements of vector and raster GIS analysis that assists the proper urban sustainability grading within the chosen model, the reliability of spatial data collected; analysis selected and resulted spatial information. Starting from selecting some important indicators to comprise the model which include regional culture, climate and community needs an example of what was used is Energy Demand & Consumption (Cooling systems). Thus, this factor is related to the climate and it‟s regional specific as the temperature varies around 30-45 degrees centigrade in city areas, GIS 3D Polygons of building data used to analyse the volume of buildings, attributes „building heights‟, estimate the number of floors from the equation, following energy demand was calculated and consumption for the unit volume, and compared it in scenario with possible sustainable energy supply or using different environmental friendly cooling systems this is followed by calculating the cooling system effects on an area unit selected to be 1 sq. km, combined with the level of greenery area, and open space, as represented by parks polygons, trees polygons, empty areas, pedestrian polygons and road surface area polygons. (initial measures showed that cooling system consumption can be reduced by around 15 -20 % with a well-planned building distributions, proper spaces and with using environmental friendly products and building material, temperature levels were also combined in the scenario extracted from satellite images as interpreted from thermal bands 3 times during the period of assessment. Other examples of the assessment of GIS analysis to urban sustainability took place included Waste Productivity, some effects of greenhouse gases measured by the intensity of road polygons and closeness to dwelling areas, industry areas as defined from land use land cover thematic maps produced from classified satellite images then vectors were created to take part in defining their role within the scenarios. City Noise and light intensity assessment was also investigated, as the region experiences rapid development and noise is magnified due to construction activities, closeness of the airports, and highways. The assessment investigated the measures taken by urban planners to reduce degradation or properly manage it. Finally as a conclusion tables were presented to reflect the scenario results in combination with GIS data types, analysis types, and the level of GIS data reliability to measure the sustainability level of a city related to cultural and regional demands.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium alloys are of great demand in the aerospace and biomedical industries. Most the titanium products are either cast or sintered to required shape and finish machined to get the appropriate surface texture to meet the design requirements. Ti-6Al-4V is often referred as work horse among the titanium alloys due to its heavy use in the aerospace industry. This paper is an attempt to investigate and improve the machining performance of Ti-6Al-4V. Thin wall machining is an advance machining technique especially used in machining turbine blades which can be done both in a conventional way and using a special technique known as trochoidal milling. The experimental design consists of conducting trials using combination of cutting parameters such as cutting speed (vc), 90 and 120 m/min; feed/tooth (fz) of 0.25 and 0.35 mm/min; step over (ae) 0.3 and 0.2; at constant depth of cut (ap) 20mm and using coolant. A preliminary assessment of machinability of Ti-6Al-4V during thin wall machining using trochoidal milling is done. A correlation established using cutting force, surface texture and dimensional accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Internet websites and smartphone apps have become a popular resource to guide parents in their children’s feeding and nutrition. Given the diverse range of websites and apps on infant feeding, the quality of information in these resources should be assessed to identify whether consumers have access to credible and reliable information.

Objective: This systematic analysis provides perspectives on the information available about infant feeding on websites and smartphone apps.

Methods: A systematic analysis was conducted to assess the quality, comprehensibility, suitability, and readability of websites and apps on infant feeding using a developed tool. Google and Bing were used to search for websites from Australia, while the App Store for iOS and Google Play for Android were used to search for apps. Specified key words including baby feeding, breast feeding, formula feeding and introducing solids were used to assess websites and apps addressing feeding advice. Criteria for assessing the accuracy of the content were developed using the Australian Infant Feeding Guidelines.

Results: A total of 600 websites and 2884 apps were screened, and 44 websites and 46 apps met the selection criteria and were analyzed. Most of the websites (26/44) and apps (43/46) were noncommercial, some websites (10/44) and 1 app were commercial and there were 8 government websites; 2 apps had university endorsement. The majority of the websites and apps were rated poor quality. There were two websites that had 100% coverage of information compared to those rated as fair or poor that had low coverage. Two-thirds of the websites (65%) and almost half of the apps (47%) had a readability level above the 8th grade level.

Conclusions: The findings of this unique analysis highlight the potential for website and app developers to merge user requirements with evidence-based content to ensure that information on infant feeding is of high quality. There are currently no apps available to consumers that address a variety of infant feeding topics. To keep up with the rapid turnover of the evolving technology, health professionals need to consider developing an app that will provide consumers with a credible and reliable source of information about infant feeding, using quality assessment tools and evidence-based content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In human medicine, transfusion of ABO-mismatched platelets has been associated with shortened platelet survival and refractoriness to platelet transfusion because of expression of certain blood group antigens on platelets. It remains unknown if canine platelets express dog erythrocyte antigens (DEAs). Objective: The aim of this study was to develop a flow cytometric assay for DEA 1.1 and determine whether DEA 1.1 is present on canine platelets.Methods: Blood was collected from 172 clinically healthy dogs. Platelets and erythrocytes from each dog were tested for DEA 1.1 by flow cytometry using anti-DEA 1.1 blood-typing sera. Erythrocytes from each dog were also assessed for DEA 1.1 using a standard tube-typing test (T1) and using a second tube method (T2), if the flow cytometric and T1 results differed.Results: Using flow cytometry, DEA 1.1 was detected on erythrocytes of all 110 dogs shown by T1 or T2 testing to be DEA 1.1-positive. Initial results of the T1 test had a diagnostic accuracy of 93% (160 correct/ 172 tests). The frequency of erythrocyte DEA 1.1 positivity in previously untyped dogs (n = 118) was 56%. DEA 1.1 expression was not detected on platelets from DEA 1.1-positive dogs.Conclusions: Flow cytometry was a reliable method for detection of DEA 1.1 on canine erythrocytes. The absence of DEA 1.1 on platelets from DEA 1.1-positive dogs suggests that their platelets do not express DEA 1.1 and will not induce production of anti-DEA 1.1 antibodies that might lead to platelet refractoriness or reactions to a subsequent transfusion of DEA 1.1positive erythrocytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Williams-Beuren syndrome (WBS) is a genetic disorder characterized by physical and intellectual developmental delay, associated with congenital heart disease and facial dysmorphism. WBS is caused by a microdeletion on chromosome 7 (7q11.23), which encompasses the elastin (ELN) gene and about 27 other genes. The gold standard for WBS laboratory diagnosis is FISH (fluorescence in situ hybridization), which is very costly. As a possible alternative, we investigated the accuracy of three clinical diagnostic scoring systems in 250 patients with WBS diagnosed by FISH. We concluded that all three systems could be used for the clinical diagnosis of WBS, but they all gave a low percentage of false-positive (6.0-9.2%) and false-negative (0.8-4.0%) results. Therefore, their use should be associated with FISH testing. © FUNPEC-RP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)