960 resultados para Arch of hollow cathode


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the study was to investigate the effect of skate blade radius of hollow (ROH) on anaerobic performance, specifically during the acceleration and stopping phases of an on-ice skating test. Fifteen, male Junior B hockey players (mean age 19 y ± 1.46) were recruited to participate. On-icc testing required each participant to complete an on-ice anaerobic performance test [Reed Repeat Skate (RRS)) on three separate days. During each on-ice test, the participant's skate blades were sharpened to one of three, randomly assigned, ROH values (0.63 cm, 1.27 cm, 1.90 cm). Performance times were recorded during each RRS and used to calculate anaerobic variables [anaerobic power (W), anaerobic capacity (W), and fatigue index (s, %)). Each RRS was video recorded for the purpose of motion analysis. Video footage was imported into Peak Motus™ to measure kinematic variables of the acceleration and stopping phases. The specific variables calculated from the acceleration phase were: average velocity over 6 m (m/s), average stride length (m), and mean stride rate (strides/s). The specific variables calculated from the stopping phase were: velocity at initiation of stopping (rn/s), stopping distance (m), stopping time (s). A repeated measures ANOV A was used to assess differences in mean performance and kinematic variables across the three selected hollows. Further analysis was conducted to assess differences in trial by trial performance and kinematic variables for all hollows. The primary findings of the study suggested that skate blade ROH can have a significant effect on kinematic variables, namely stride length and stride rate during the acceleration phase and stopping distance and stopping time during the stopping phase of an on-ice anaerobic performance test. During the acceleration phase, no significant difdifferences were found in SR and SL across the three selected hollows. Mean SR on the 1.27 cm hollow was significantly slower than both the 0.63 cm and 1.90 cm hollows and SL was significantly longer when skating on the 1.27 cm hollow in comparison to the 1.90 cm hollow. During the stopping phase, stopping distance on the 0.63 cm hollow (4.12 m ± 0.14) was significantly shorter than both the 1.27 cm hollow (4.43 m ± 0.08) (p < 0.05) and the 1.90 cm ho])ow (4.35 m ± 0.12) (p < 0.05). Mean ST was also significantly shorter when stopping on the 0.63 cm hollow then both the 1.27 cm and 1.90 cm hollows. Trial by trial results clearly illustrated the affect of fatigue on kinematic variables; AV, SR, IV decreased from trial 1 to 6. There was no significant effect on anaerobic performance variables during the RRS. Altering the skate blade ROH has a significant and practical affect on accelerating and stopping performance will be discussed in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The primary purpose of this study was to investigate the effect of skate blade shape on skating performance. A secondary purpose was to evaluate if a change in hollow shape can create additional effects on skating performance. Thirty-seven male ice hockey players (age=18 years, SD=3.4) participated. The intervention consisted of four sharpening trials assessed using three on-ice tests. Participant feedback was also assessed using a Likert scale questionnaire. Statistical analysis included within-subject repeated measures MANOVA of trial by skating variables (p≤0.05). Results revealed Contour 1 enhanced performance compared to baseline on six variables at varsity level and five variables at midget level. Contour 1 enhanced performance compared to Contour 2 on six variables at the varsity and midget levels. Contour 1 also scored highest on the feedback questionnaire. Findings of this study indicate that contouring is a necessary practice to achieve optimal skating performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unsigned letter to John Williams stating that before the return of the final estimate, the arch of the bridge must be completed, Sept. 19, 1857

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hollow sphere cellular aluminium (HSCA) samples were fabricated by bonding together two kinds of single aluminium hollow spheres with the same outside diameter of 4 mm but different wall thicknesses of 0.1 mm and 0.3 mm, in which the hollow spheres with the thinner sphere wall thickness were used as artificial defects. Four types of HSCA samples with the same relative density but various distributions of artificial defects were prepared by simple cubic packing. For comparing, HSCA sample without defective hollow spheres inside was also prepared. The effects of the distribution of the artificial defects on the deformation behaviours and mechanical properties were investigated by compressive tests. Results indicated that the nominal stress - nominal strain curve and the deformation behavior of the HSCA samples varied with the distribution of the artificial defects in spite of the same relative density. It is therefore suggested that the deformation behavior and mechanical property of cellular materials were also significantly affected by the distribution of defects. In particular, the plateau stress of the HSCA samples increased with the decrease in number of contact points between the normal hollow spheres and the defective hollow spheres in the loading direction during deformation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Manufactured cellular aluminums have been developed for a wide range of automotive applications where weight savings, improved safety, crashworthiness and comfort are required. The plateau deformation behavior of cellular aluminums under compressive loading makes this new class of lightweight materials suitable for energy absorption and comes close to ideal impact absorbers. In the present study, aluminum hollow hemispheres were firstly processed by pressing. Hollow sphere aluminum samples with a body-centered cubic (BCC) packing were then fabricated by bonding together single hollow spheres, which were prepared by adhering together hollow hemispheres. Hollow sphere aluminum samples with various kinds of sphere wall thicknesses of 0.1 mm, 0.3 mm and 0.5 mm but the same outside diameter of 4 mm were investigated by compressive tests. The effects of the sphere wall thickness on the mechanical properties and energy absorption characteristics were investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hollow sphere metallic foams are a new class of cellular material that possesses the attractive advantages of uniform cell size distribution and regular cell shape. These result in more predictable physical and mechanical properties than those of cellular materials with a random cell size distribution and irregular cell shapes. In the present study, single aluminum hollow spheres with three kinds of sphere wall thickness as 0.1 mm, 0.3 mm and 0.5 mm were processed by a new pressing method. Hollow sphere aluminum foam samples were prepared by bonding together single hollow spheres with simple cubic packing (SC) and body-centered cubic packing (BCC). Compressive tests were carried out to evaluate the deformation behaviors and mechanical properties of the hollow sphere aluminum foams. Effects of the sphere wall thickness and packing style on the mechanical properties were investigated.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

 Hollow mesoporous silica nanoparticles were successfully fabricated and functionalized with appropriate silanes. After modifications, amine, carboxyl, cyano, and methyl groups were grafted onto the nanoparticles and all functionalized hollow mesoporous silica nanoparticles maintained a spherical and hollow structure with a mean diameter of ~120 nm and a shell thickness of ~10 nm. The loading capacity of the hollow mesoporous silica nanoaprticles to the anticancer drug, 5-fluorouracil, can be controlled via precise functionalization. The presence of amine groups on the surface of nanoparticles resulted in the highest loading capacity of 28.89%, due to the amine functionalized nanoparticles having a similar hydrophilicity but reverse charge to the drug. In addition, the change in pH leads to the variation of the intensity of electrostatic force between nanoparticles and the drug, which finally affects the loading capacity of amine functionalized hollow mesoporous silica nanoparticles to some extent. Higher drug loading was observed at pH of 7.4 and 8.5 as 5-fluorouracil becomes more deprotonated in alkaline conditions. The improved drug loading capacity by amine functionalized hollow mesoporous silica nanoparticles has demonstrated that they can become potential intracellular 5-fluorouracil delivery vehicles for cancers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new model for the representation of electrodes' filaments of hot-cathode fluorescent lamps, during preheating processes based on the injection of currents with constant root mean square (rms) values. The main improvement obtained with this model is the prediction of the R-h/R-c ratio during the preheating process, as a function of the preheating time and of the rms current injected in the electrodes. Using the proposed model, it is possible to obtain an estimate of the time interval and the current that should be provided by the electronic ballast, in order to ensure a suitable preheating process. is estimate of time and current can be used as input data in the design of electronic ballasts with programmed lamp start, permitting the prediction of the R-h/R-c ratio during the initial steps of the design (theoretical analysis and digital simulation). Therefore, the use of the proposed model permits to reduce the necessity of several empirical adjustments in the prototype, in order to set the operation of electronic ballasts during the preheating process. This fact reduces time and costs associated to the global design procedure of electronic ballasts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors studied the behavior of calcium phosphate materials used as inlay implants into bone cavities prepared in the zygomatic arch of rats. Fifty male albino rats were divided into four groups as follows: group I-preparation of bone cavities which did not receive any implant material as controls; group II-implants of Interpore 200; group III-implants of experimental hydroxylapatite; group IV-implants of experimental hydroxylapatite combined with collagen. The animals were sacrificed after 5, 15, 30, 60 and 120 days and the specimens were submitted to histological analysis. Results showed that the experimental hydroxylapatite used in group III presented better osteogenic properties compared to the other materials. All tested materials were biocompatible, although group IV presented a more intense inflammatory response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.