321 resultados para Anisotropías magnéticas]


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biologia Geral e Aplicada - IBB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El uso de las partículas magnéticas ha venido a más durante los últimos 10 años. Lo anterior ha estado condicionado por factores como la amplia investigación en materiales a nivel atómico, los retos propuestos por las diferentes áreas de investigación donde los niveles nanométricos cobran importancia, la inherente innovación tecnológica que pueden aportar a la industria dichas escalas y finalmente, el impacto socioeconómico que pueden tener estos avances tecnológicos. Sin embargo, la traslación a la industria de los avances tecnológicos se ha visto limitada por la falta de estrategias, ya que el 88% del conocimiento se queda en Universidades y Centros de Investigación y el resto, 12%, pasa a la industria o es obtenido en ella. En este trabajo de investigación se ha tratado de completar el círculo de idea, conceptualización, generación de conocimiento, prototipo, prueba in vitro y prueba in vivo; todo ello para dejar el menor espacio posible entre Investigación e Industria. Se ha fabricado un recinto que permite la observación del comportamiento de las partículas magnéticas cuando están inmersas en un medio con viscosidad controlada y con una fuente magnética estática. De la observación experimental se han encontrado fenómenos magnéticos como la aglomeración y la autoorganización, que han sido aprovechados, no solo para ofrecer una solución alternativa a la corrección del desprendimiento de retina, sino también para promover las mejoras de métodos de separación y/o filtrado celular, ayuda en correcciones ortopédicas o en el diagnóstico y tratamiento de enfermedades degenerativas. Particularizando en la corrección del desprendimiento de retina, se ha desarrollado y patentado un Dispositivo Ocular cuya función es la de tapón del agujero retiniano, ayudando en la cicatrización de la retina. Dicho dispositivo ha sido evaluado en conejos albinos neozelandeses obteniéndose un éxito en la reaplicación de la retina del 80% y resultando su toxicidad en condición difusa tras evaluación anatomopatológica. Así mismo, el ferrofluido diseñado y fabricado se ha localizado en la zona de interacción magnética siempre y su disposición ha sido en el mayor de los casos en forma de placa pero también se han formado anillos; lo anterior no ha afectado en ningún sentido el éxito en la reaplicación de la retina. Por otro lado, no se han encontrado indicios de siderosis en la zona de interacción magnética, sus alrededores o el resto del globo ocular; ni las células han presentado apoptosis inducida por los materiales introducidos en el ojo. Sin embargo, se ha encontrado una fuerte necrosis inducida por la presión ejercida sobre la retina por el dispositivo ocular, evidenciando la necesidad de un mejor control de dicha presión. Tras la caracterización de los copos y la presión que éstos ejercen, se ha podido identificar que el dispositivo ocular se puede sintonizar para inducir una presión entre 0.5 y 2.5 mmHg; por tanto se puede vislumbrar que es posible minimizar la muerte celular causada en las células retinianas. Finalmente, tras la experimentación con conejos se ha observado que el dispositivo ocular resuelve los problemas inducidos por las siliconas o los gases e inclusive aporta ventajas competitivas de alto valor añadido como: no requerir de posiciones incómodas en el post-operatorio, no modifica las propiedades ópticas del ojo ya que no es necesario dejar silicona o gases en el interior del ojo, se pueden sellar múltiples agujeros retinianos, corrección de desprendimiento de retina inferior sin complicaciones asociadas, etc.; en definitiva mejora la calidad de vida domiciliaria del paciente además de solventar los problemas inducidos por las soluciones actuales. The using of magnetic particles has become more important during last 10 years. This event has been conditioned by several factors like a wide researching on materials at atomic level, the challenges proposed by different research areas where nanometric levels became important, the inherent technological innovation to the industry and finally, the socioeconomic impact of these kinds of technologies. However, the nanotechnological advances have not been well addressed to the industry since 88% of the acknowledge keeps on Universities and Research Centers, and the remaining 12% goes through the industry or is obtained in it. In this research work, we have tried to complete the entire process about idea, concept, acknowledge generation, prototyping and in vitro and in vivo testing; all to leave as little space as possible between Research and Industry. We have built an experimental hall which allows us the observation of magnetic particles' behavior when are immersing in a controlled viscous medium and under a static magnetic field. The experimental observation has been useful to identify and use two magnetic phenomena: agglomeration and self-organization; no only for retinal detachment, but also to improve cellular separation and/or filtered methods, orthopedic solutions or the diagnostic and treatment of degenerative diseases. Particularizing on retinal detachment, we have developed and patented an Ocular Device which its function is acting like a tampon of the retinal hole for helping with the scarring retina. The device has been evaluated in animals and the results show that we can achieve a success of 80% before rabbit’s death and non cell apoptosis, only necrosis, over the retina attached by the ocular device after anatomopathological evaluation. Also we have identified a diffuse toxicity after anatomopathological evaluation, so more experimenting must be proposed. Otherwise, the ferrofluid has been localized where the magnetic interaction area is located and its deposition has been in most cases plaque shape like but rings have also been observed; this has not affected in any way the successful reattachment of the retina. On the other hand, we have not found any evidence of siderosis in the magnetic interaction zone, near of or some other place of the ocular globe; and we did not find any apoptosis induced by the materials inserted within the eye. However full necrosis, exactly on the magnetic interaction zone, has been found and induced by the pressure exerted over the retina by the ocular device, evidencing the needing of its better control. After flakes’ characterization and its pressure exerted, we identified that the ocular device can be tuned in order to induce a pressure between 0.5 and 2.5 mmHg; therefore we can perceive that death caused to the retinal cells can be minimized. Finally, the experimentation has shown that the ocular device solves all problems induced by silicone or gases an even contributes with some other competitive advantages of high added value like: no uncomfortable postoperative positions, it does not modify any optical property of the eye because there is no needing of leaving silicone or gases inside the eye, many holes can be sealed, the inferior retinal detachment can be solve without any complications, etc.; definitively the ocular device improves patients’ quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tesis presenta un análisis teórico del funcionamiento de toberas magnéticas para la propulsión espacial por plasmas. El estudio está basado en un modelo tridimensional y bi-fluido de la expansión supersónica de un plasma caliente en un campo magnético divergente. El modelo básico es ampliado progresivamente con la inclusión de términos convectivos dominantes de electrones, el campo magnético inducido por el plasma, poblaciones electrónicas múltiples a distintas temperaturas, y la capacidad de integrar el flujo en la región de expansión lejana. La respuesta hiperbólica del plasma es integrada con alta precisión y eficiencia haciendo uso del método de las líneas características. Se realiza una caracterización paramétrica de la expansión 2D del plasma en términos del grado de magnetización de iones, la geometría del campo magnético, y el perfil inicial del plasma. Se investigan los mecanismos de aceleración, mostrando que el campo ambipolar convierte la energía interna de electrones en energía dirigida de iones. Las corrientes diamagnéticas de Hall, que pueden hallarse distribuidas en el volumen del plasma o localizadas en una delgada capa de corriente en el borde del chorro, son esenciales para la operación de la tobera, ya que la fuerza magnética repulsiva sobre ellas es la encargada de confinar radialmente y acelerar axialmente el plasma. El empuje magnético es la reacción a esta fuerza sobre el motor. La respuesta del plasma muestra la separación gradual hacia adentro de los tubos de iones respecto de los magnéticos, lo cual produce la formación de corrientes eléctricas longitudinales y pone el plasma en rotación. La ganancia de empuje obtenida y las pérdidas radiales de la pluma de plasma se evalúan en función de los parámetros de diseño. Se analiza en detalle la separación magnética del plasma aguas abajo respecto a las líneas magnéticas (cerradas sobre sí mismas), necesaria para la aplicación de la tobera magnética a fines propulsivos. Se demuestra que tres teorías existentes sobre separación, que se fundamentan en la resistividad del plasma, la inercia de electrones, y el campo magnético que induce el plasma, son inadecuadas para la tobera magnética propulsiva, ya que producen separación hacia afuera en lugar de hacia adentro, aumentando la divergencia de la pluma. En su lugar, se muestra que la separación del plasma tiene lugar gracias a la inercia de iones y la desmagnetización gradual del plasma que tiene lugar aguas abajo, que permiten la separación ilimitada del flujo de iones respecto a las líneas de campo en condiciones muy generales. Se evalúa la cantidad de plasma que permanece unida al campo magnético y retorna hacia el motor a lo largo de las líneas cerradas de campo, mostrando que es marginal. Se muestra cómo el campo magnético inducido por el plasma incrementa la divergencia de la tobera magnética y por ende de la pluma de plasma en el caso propulsivo, contrariamente a las predicciones existentes. Se muestra también cómo el inducido favorece la desmagnetización del núcleo del chorro, acelerando la separación magnética. La hipótesis de ambipolaridad de corriente local, común a varios modelos de tobera magnética existentes, es discutida críticamente, mostrando que es inadecuada para el estudio de la separación de plasma. Una inconsistencia grave en la derivación matemática de uno de los modelos más aceptados es señalada y comentada. Incluyendo una especie adicional de electrones supratérmicos en el modelo, se estudia la formación y geometría de dobles capas eléctricas en el interior del plasma. Cuando dicha capa se forma, su curvatura aumenta cuanto más periféricamente se inyecten los electrones supratérmicos, cuanto menor sea el campo magnético, y cuanto más divergente sea la tobera magnética. El plasma con dos temperaturas electrónicas posee un mayor ratio de empuje magnético frente a total. A pesar de ello, no se encuentra ninguna ventaja propulsiva de las dobles capas, reforzando las críticas existentes frente a las propuestas de estas formaciones como un mecanismo de empuje. Por último, se presenta una formulación general de modelos autosemejantes de la expansión 2D de una pluma no magnetizada en el vacío. El error asociado a la hipótesis de autosemejanza es calculado, mostrando que es pequeño para plumas hipersónicas. Tres modelos de la literatura son particularizados a partir de la formulación general y comparados. Abstract This Thesis presents a theoretical analysis of the operation of magnetic nozzles for plasma space propulsion. The study is based on a two-dimensional, two-fluid model of the supersonic expansion of a hot plasma in a divergent magnetic field. The basic model is extended progressively to include the dominant electron convective terms, the plasma-induced magnetic field, multi-temperature electron populations, and the capability to integrate the plasma flow in the far expansion region. The hyperbolic plasma response is integrated accurately and efficiently with the method of the characteristic lines. The 2D plasma expansion is characterized parametrically in terms of the ion magnetization strength, the magnetic field geometry, and the initial plasma profile. Acceleration mechanisms are investigated, showing that the ambipolar electric field converts the internal electron energy into directed ion energy. The diamagnetic electron Hall current, which can be distributed in the plasma volume or localized in a thin current sheet at the jet edge, is shown to be central for the operation of the magnetic nozzle. The repelling magnetic force on this current is responsible for the radial confinement and axial acceleration of the plasma, and magnetic thrust is the reaction to this force on the magnetic coils of the thruster. The plasma response exhibits a gradual inward separation of the ion streamtubes from the magnetic streamtubes, which focuses the jet about the nozzle axis, gives rise to the formation of longitudinal currents and sets the plasma into rotation. The obtained thrust gain in the magnetic nozzle and radial plasma losses are evaluated as a function of the design parameters. The downstream plasma detachment from the closed magnetic field lines, required for the propulsive application of the magnetic nozzle, is investigated in detail. Three prevailing detachment theories for magnetic nozzles, relying on plasma resistivity, electron inertia, and the plasma-induced magnetic field, are shown to be inadequate for the propulsive magnetic nozzle, as these mechanisms detach the plume outward, increasing its divergence, rather than focusing it as desired. Instead, plasma detachment is shown to occur essentially due to ion inertia and the gradual demagnetization that takes place downstream, which enable the unbounded inward ion separation from the magnetic lines beyond the turning point of the outermost plasma streamline under rather general conditions. The plasma fraction that remains attached to the field and turns around along the magnetic field back to the thruster is evaluated and shown to be marginal. The plasmainduced magnetic field is shown to increase the divergence of the nozzle and the resulting plasma plume in the propulsive case, and to enhance the demagnetization of the central part of the plasma jet, contrary to existing predictions. The increased demagnetization favors the earlier ion inward separation from the magnetic field. The local current ambipolarity assumption, common to many existing magnetic nozzle models, is critically discussed, showing that it is unsuitable for the study of plasma detachment. A grave mathematical inconsistency in a well-accepted model, related to the acceptance of this assumption, is found out and commented on. The formation and 2D shape of electric double layers in the plasma expansion is studied with the inclusion of an additional suprathermal electron population in the model. When a double layer forms, its curvature is shown to increase the more peripherally suprathermal electrons are injected, the lower the magnetic field strength, and the more divergent the magnetic nozzle is. The twoelectron- temperature plasma is seen to have a greater magnetic-to-total thrust ratio. Notwithstanding, no propulsive advantage of the double layer is found, supporting and reinforcing previous critiques to their proposal as a thrust mechanism. Finally, a general framework of self-similar models of a 2D unmagnetized plasma plume expansion into vacuum is presented and discussed. The error associated with the self-similarity assumption is calculated and shown to be small for hypersonic plasma plumes. Three models of the literature are recovered as particularizations from the general framework and compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los nanomateriales han adquirido recientemente un gran interés debido a la gran variedad de aplicaciones que pueden llegar a tener en el ámbito de la biomedicina. Este trabajo recoge las posibilidades tanto diagnósticas como terapéuticas que presentan dos modalidades de nanomateriales: nanopartículas de óxido de hierro y nanopartículas de oro. Para ello, en una primera aproximación se ha llevado a cabo la caracterización de las nanopartículas desde el punto de vista de la biocompatibilidad asociada a su tamaño y al tiempo de contacto o circulación en células y tejidos, ensayada tanto in vitro como in vivo así como la cinética de acumulación de dichas nanopartículas en el organismo vivo. Posteriormente se ha realizado la biofuncionalización de los dos tipos de nanopartículas para reconocer dianas moleculares específicas y poder ser utilizadas en el futuro en dos aplicaciones biomédicas diferentes: diagnóstico de enfermedad de Alzheimer mediante imagen de resonancia magnética y destrucción selectiva de células tumorales mediante hipertermia óptica. ABSTRACT Nanomaterials have recently gained a great interest due to the variety of applications that can have in the field of biomedicine. This work covers both diagnostic and therapeutic possibilities that present two types of nanomaterials: iron oxide nanoparticles and gold nanoparticles. Therefore, in a first approximation it has performed the characterizing of nanoparticles from the standpoint of biocompatibility associated with their size and time of contact or movement in cells and tissues, tested both in vitro and in vivo as well as the kinetics of accumulation of the nanoparticles into the living organism. Subsequently the biofunctionalization of two types of nanoparticles was made to recognize specific molecular targets and can be used in the future in two different biomedical applications: diagnosis of Alzheimer's disease by magnetic resonance imaging and selective destruction of tumor cells by optical hyperthermia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Persiguiendo los objetivos dados por la descripción formal del trabajo de fin de grado, la labor realizada ha sido dirigida hacia cuatro enfoques principales: el estudio teórico de las redes, la generación de redes funcionales a partir de datos de experimentos de resonancias magnéticas funcionales, el análisis de la topología de estas redes y el desarrollo de herramientas informáticas necesarias a esas tareas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quais propriedades magnéticas são modificadas quando se agrupam átomos de Fe/Co para formar estruturas quasi-2D, se comparadas aos nanofios (quasi-1D) de FexCo1-x? E como estas propriedades reagem com a variação da proporção de Fe/Co nos aglomerados? A fim de responder a estas questões, trímeros de FexCo1-x depositados em Pt(111) são investigados utilizando o método de primeiros princípios Real Space-Linear Muffin-Tin Orbital-Atomic Sphere Approximation (RS-LMTO-ASA) no âmbito da Teoria do Funcional da Densidade (DFT). Diferentes configurações de trímeros triangulares são consideradas, variando-se as posições e a concentração dos átomos de Fe/Co. Neste trabalho, demonstra-se a ocorrência de uma tendência não-linear estritamente decrescente dos momentos orbitais médios como função da concentração de Fe, distinta do encontrado tanto para os nanofios de FexCo1-x (dependência linear) quanto para a monocamada correspondente (dependência não-linear). Os resultados obtidos mostram ainda que os momentos orbitais variam com o ambiente local e com a direção de magnetização, especialmente quando associados aos átomos de Co, em concordância com publicações anteriores. A mudança de dimensionalidade quasi-1D (nanofios) para quasi-2D (trímeros compactos) não afeta o comportamento dos momentos de spin, que permanecem descritos por uma função linear com respeito à proporção de Fe/Co. Ambos o formato e a concentração de Fe nos sistemas apresentam um papel importante nos valores de energia de anisotropia magnética. Em adição, observou-se que o subtrato de Pt opera ativamente na definição das propriedades magnéticas dos aglomerados. Embora todas as configurações lineares e compactas dos aglomerados de FexCo1-x sejam estáveis e exibam interações fortemente ferromagnéticas entre os primeiros vizinhos, nem todas revelaram o ordenamento colinear como estado fundamental, apresentando uma interação de Dzyaloshinskii-Moriya não-desprezível induzida pelo acoplamento spin-órbita. Estes casos específicos são: o trímero triangular de Co puro e o trímero linear (nanofio) de Fe puro, para o qual foi verificado o acoplamento do tipo Ruderman-Kittel-Kasuya-Yosida entre os átomos de Fe constituintes. Os resultados obtidos contribuem para o entendimento de quais mecanismos definem o magnetismo nos trímeros de FexCo1-x/Pt(111), e discutem as questões presentes atualmente na literatura no contexto destes sistemas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin films of Co2FeAl (CFA) and trilayers with CFA/M/CFA, where M is Au or Ag, produced by magnetron sputtering onto glass and oriented (MgO (100)) substrates were investigated. The structural, magnetic static and magnetic dynamics properties were analyzed by distinct experimental techniques. Through X-ray diffraction was observed an A2 phase for the samples (completely disordered), where the atoms are randomly located in the lattice. The static magnetic behavior, in some samples, reveal a plateau behavior generated by a biphasic system. The magnetoimpedance measurements were performed by varying the angle between the external magnetic field and current with respect of anisotropy direction. For this reason, the MI results show a asymmetric magnetoimpedance (AMI) behavior. For the single and trilayers samples with 500 nm-thick, the AMI effect is more evident in comparison with samples with 1000 nm-thick. Therefore, in this work was stablished a route to produce Heusler alloy samples with A2 phase in thin film geometry onto amorphous and oriented substrates, and due to structural disorder was possible to study the hysteretic and MI asymmetric effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Located on the western edge of the Brazilian northeast, the Parnaíba Basin is an intra cratonic basin with oil production. This study aims at understanding its genesis and evolution, using aeromagnetic and gravity data. We used the spectral analysis of aeromagnetic data to map the depth to the bottom of the magnetic sources in order to assimilate this depth with the depth of the Curie isotherm, and infer the geothermal gradient. Using the spectral analysis technique, we succeeded in mapping the surface of the depth to the bottom of magnetic sources (SBFM), which marks the depth that occur magnetization. In the Parnaíba Basin the SBFM presented depths around -20,5 and -28,5 , which was consistent with an inversion of the same dataset using the technique of Magnetization Vector Inversion (MVI). Furthermore, SBFM topography correlates well with Moho depth, which was estimated from satellite gravimetric data from the GOCE mission (Gravity Field and Steady-State Ocean Circulation Explorer). Assuming that SBFM coincides with the Curie isotherm of magnetite (ICM), defined as the surface at which magnetite ( ) looses its ferromagnetic properties, it was possible to estimate the geothermal gradient. The geothermal gradient in the basin showed values between 19.2 and 26.5 , allowing to estimate the heat flow for the Parnaíba basin after assuming a conductivity of 2.69 . The resulting heat flow values ranged between 51.6 and 71.3 , which is consistent with values found in other works throughout the South American continent. Lithospheric thickness using an empirical relationship, finding values between -65.8 and -89.2 . We propose that thermal structure of Parnaíba basin is influenced by a deep thermal anomaly. This anomaly has heated the lithosphere beneath the basin and has resulted in relatively thin values for the lithospheric thickness and relatively high surface heat flow values. The origin of the anomaly is not clear, but the correlation between Curie depth and Moho topography, suggests that tectonic extension processes could have played a role.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ionospheric Disturbances – TIDs – are irregularities on the ionospheric plasma propagating in speeds in the order of tens to a few hundreds of meters per second. This present study detected and characterized the TIDs of LSTIDs (Large Scale Travelling Ionospheric Disturbance) type at low latitudes during intense geomagnetic storms and its propagation over the Brazilian sector. This work also shows as being the first to report systematically propagation of gravity waves over Natal. For this purpose, we used ionospheric records obtained from type of digisonde CADI (Canadiam Advanced Digital Ionosonde) located in Natal and the type DSP (Digisonde Portable Souder) located in Cachoeira Paulista, Fortaleza and São Luis, whereupon we used a dataset of 12 years collected by INPE (National Institute of Space Research). In this study, both calm days, that preceded the storms, and the geomagnetically disturbed days were related during the years 2000 and 1012, which cover a period of maximum and minimum solar activity. And it is presented the variations that happened in the electron density from region F of the ionosphere over the Brazilian sector, especially near the Equator (Natal, Fortaleza and São Luis), caused by ionospheric disturbances in the equatorial region during intense geomagnetic storms, because, as we know of the literature in this area, this phenomenon contributes positively to the emergence of LSTIDs in the auroral region, which may move to the equatorial region where a few cases have been documented and studied systematically. From the observation of signatures if TIDs in ionogram records, a study of the morphology of these events was performed and compared with the main characteristics of the wave of this phenomenon during great magnetic storms, i.e., DST <(-200 nT) and KP > 6. Thus, we obtained the main characteristics of TIDs over our region, i.e., period, vertical wavelength, phase and propagation speed, as well as the delay of these disturbances compared to the beginning of the magnetic storms to the Brazilian Sector.