909 resultados para Android Arduino ECG


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The battle to mitigate Android malware has become more critical with the emergence of new strains incorporating increasingly sophisticated evasion techniques, in turn necessitating more advanced detection capabilities. Hence, in this paper we propose and evaluate a machine learning based approach based on eigenspace analysis for Android malware detection using features derived from static analysis characterization of Android applications. Empirical evaluation with a dataset of real malware and benign samples show that detection rate of over 96% with a very low false positive rate is achievable using the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a low complexity high efficiency decimation filter which can be employed in EletroCardioGram (ECG) acquisition systems. The decimation filter with a decimation ratio of 128 works along with a third order sigma delta modulator. It is designed in four stages to reduce cost and power consumption. The work reported here provides an efficient approach for the decimation process for high resolution biomedical data conversion applications by employing low complexity two-path all-pass based decimation filters. The performance of the proposed decimation chain was validated by using the MIT-BIH arrhythmia database and comparative simulations were conducted with the state of the art.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para a obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted in the fulfilment of the requirements for the Degree of Master in Electronic and Telecomunications Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projeto para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projeto apresentado ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Marketing Digital, sob orientação do Mestre Paulo Gonçalves

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente os sistemas Automatic Vehicle Location (AVL) fazem parte do dia-a-dia de muitas empresas. Esta tecnologia tem evoluído significativamente ao longo da última década, tornando-se mais acessível e fácil de utilizar. Este trabalho consiste no desenvolvimento de um sistema de localização de veículos para smartphone Android. Para tal, foram desenvolvidas duas aplicações: uma aplicação de localização para smarphone Android e uma aplicação WEB de monitorização. A aplicação de localização permite a recolha de dados de localização GPS e estabelecer uma rede piconet Bluetooth, admitindo assim a comunicação simultânea com a unidade de controlo de um veículo (ECU) através de um adaptador OBDII/Bluetooth e com até sete sensores/dispositivos Bluetooth que podem ser instalados no veículo. Os dados recolhidos pela aplicação Android são enviados periodicamente (intervalo de tempo definido pelo utilizador) para um servidor Web No que diz respeito à aplicação WEB desenvolvida, esta permite a um gestor de frota efetuar a monitorização dos veículos em circulação/registados no sistema, podendo visualizar a posição geográfica dos mesmos num mapa interativo (Google Maps), dados do veículo (OBDII) e sensores/dispositivos Bluetooth para cada localização enviada pela aplicação Android. O sistema desenvolvido funciona tal como esperado. A aplicação Android foi testada inúmeras vezes e a diferentes velocidades do veículo, podendo inclusive funcionar em dois modos distintos: data logger e data pusher, consoante o estado da ligação à Internet do smartphone. Os sistemas de localização baseados em smartphone possuem vantagens relativamente aos sistemas convencionais, nomeadamente a portabilidade, facilidade de instalação e baixo custo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nos últimos anos, a nossa sociedade sofreu alterações significativas ao nível tecnológico que têm vindo a modificar o quotidiano do cidadão e transportaram para a palma da mão um conjunto significativo de tarefas até há poucos anos impensáveis. Atualmente, torna-se possível realizar as mais simples tarefas como, a título de exemplo, efetuar um cálculo matemático, tirar fotografias ou registar numa agenda um compromisso, ou tarefas mais complexas, como por exemplo, escrever ou editar um documento, trabalhar numa folha de cálculo ou enviar um e-mail com um anexo, isto tudo com o recurso a um simples dispositivo móvel, conhecido como smartphone ou tablet. Apesar de existirem diversos tipos de apps que seriam um bom auxílio para o aumento da produtividade dos utilizadores de dispositivos móveis Android, nem todos têm conhecimento das mesmas, pelo que é importante que os utilizadores tenham conhecimentos das vantagens da utilização destes recursos e de tudo o que podem realizar com os seus dispositivos com o objetivo de aumentar a sua produtividade profissional ou pessoal. O presente estudo pretende contribuir para uma análise sobre a potencial utilização das novas tecnologias, mais propriamente estudando e recomendando apps de produtividade. Com este intuito foi criada uma app de recomendação de aplicações de produtividade com recurso a um método de sistemas de recomendação. São apresentados os resultados e as conclusões, com recurso a opiniões de potenciais utilizadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Emergency room (ER) interpretation of the ECG is critical to assessment of patients with acute coronary syndromes (ACS). Our aim was to assess its reliability in our institution, a tertiary teaching hospital. METHODS: Over a 6-month period all consecutive patients admitted for ACS were included in the study. ECG interpretation by emergency physicians (EPs) was recorded on a preformatted sheet and compared with the interpretation of two specialist physicians (SPs). Discrepancies between the 2 specialists were resolved by an ECG specialist. RESULTS: Over the 6-month period, 692 consecutive patients were admitted with suspected ACS. ECG interpretation was available in 641 cases (93%). Concordance between SPs was 87%. Interpretation of normality or abnormality of the ECG was concordant between EPs and SPs in 475 cases (74%, kappa = 0.51). Interpretation of ischaemic modifications was concordant in 69% of cases, and as many ST segment elevations were unrecognised as overdiagnosed (5% each). The same findings occurred for ST segment depressions and negative T waves (12% each). CONCLUSIONS: Interpretation of the ECG recorded during ACS by 2 SPs was discrepant in 13% of cases. Similarly, EP interpretation was discrepant from SP interpretation in 25% of cases, equally distributed between over- and underdiagnosing of ischaemic changes. The clinical implications and impact of medical education on ECG interpretation require further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: In populations of older adults, prediction of coronary heart disease (CHD) events through traditional risk factors is less accurate than in middle-aged adults. Electrocardiographic (ECG) abnormalities are common in older adults and might be of value for CHD prediction. OBJECTIVE: To determine whether baseline ECG abnormalities or development of new and persistent ECG abnormalities are associated with increased CHD events. DESIGN, SETTING, AND PARTICIPANTS: A population-based study of 2192 white and black older adults aged 70 to 79 years from the Health, Aging, and Body Composition Study (Health ABC Study) without known cardiovascular disease. Adjudicated CHD events were collected over 8 years between 1997-1998 and 2006-2007. Baseline and 4-year ECG abnormalities were classified according to the Minnesota Code as major and minor. Using Cox proportional hazards regression models, the addition of ECG abnormalities to traditional risk factors were examined to predict CHD events. MAIN OUTCOME MEASURE: Adjudicated CHD events (acute myocardial infarction [MI], CHD death, and hospitalization for angina or coronary revascularization). RESULTS: At baseline, 276 participants (13%) had minor and 506 (23%) had major ECG abnormalities. During follow-up, 351 participants had CHD events (96 CHD deaths, 101 acute MIs, and 154 hospitalizations for angina or coronary revascularizations). Both baseline minor and major ECG abnormalities were associated with an increased risk of CHD after adjustment for traditional risk factors (17.2 per 1000 person-years among those with no abnormalities; 29.3 per 1000 person-years; hazard ratio [HR], 1.35; 95% CI, 1.02-1.81; for minor abnormalities; and 31.6 per 1000 person-years; HR, 1.51; 95% CI, 1.20-1.90; for major abnormalities). When ECG abnormalities were added to a model containing traditional risk factors alone, 13.6% of intermediate-risk participants with both major and minor ECG abnormalities were correctly reclassified (overall net reclassification improvement [NRI], 7.4%; 95% CI, 3.1%-19.0%; integrated discrimination improvement, 0.99%; 95% CI, 0.32%-2.15%). After 4 years, 208 participants had new and 416 had persistent abnormalities. Both new and persistent ECG abnormalities were associated with an increased risk of subsequent CHD events (HR, 2.01; 95% CI, 1.33-3.02; and HR, 1.66; 95% CI, 1.18-2.34; respectively). When added to the Framingham Risk Score, the NRI was not significant (5.7%; 95% CI, -0.4% to 11.8%). CONCLUSIONS: Major and minor ECG abnormalities among older adults were associated with an increased risk of CHD events. Depending on the model, adding ECG abnormalities was associated with improved risk prediction beyond traditional risk factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A mathematical analysis of an electroencephalogram of a human Brain during an epileptic seizure shows that the K2 entropy decreases as compared to a clinically normal brain while the dimension of the attractor does not show significant deviation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adaptive filter is a primary method to filter Electrocardiogram (ECG), because it does not need the signal statistical characteristics. In this paper, an adaptive filtering technique for denoising the ECG based on Genetic Algorithm (GA) tuned Sign-Data Least Mean Square (SD-LMS) algorithm is proposed. This technique minimizes the mean-squared error between the primary input, which is a noisy ECG, and a reference input which can be either noise that is correlated in some way with the noise in the primary input or a signal that is correlated only with ECG in the primary input. Noise is used as the reference signal in this work. The algorithm was applied to the records from the MIT -BIH Arrhythmia database for removing the baseline wander and 60Hz power line interference. The proposed algorithm gave an average signal to noise ratio improvement of 10.75 dB for baseline wander and 24.26 dB for power line interference which is better than the previous reported works

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an attempt has been made to determine the number of Premature Ventricular Contraction (PVC) cycles accurately from a given Electrocardiogram (ECG) using a wavelet constructed from multiple Gaussian functions. It is difficult to assess the ECGs of patients who are continuously monitored over a long period of time. Hence the proposed method of classification will be helpful to doctors to determine the severity of PVC in a patient. Principal Component Analysis (PCA) and a simple classifier have been used in addition to the specially developed wavelet transform. The proposed wavelet has been designed using multiple Gaussian functions which when summed up looks similar to that of a normal ECG. The number of Gaussians used depends on the number of peaks present in a normal ECG. The developed wavelet satisfied all the properties of a traditional continuous wavelet. The new wavelet was optimized using genetic algorithm (GA). ECG records from Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) database have been used for validation. Out of the 8694 ECG cycles used for evaluation, the classification algorithm responded with an accuracy of 97.77%. In order to compare the performance of the new wavelet, classification was also performed using the standard wavelets like morlet, meyer, bior3.9, db5, db3, sym3 and haar. The new wavelet outperforms the rest

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This presentation is intended to show the use of Adobe Presenter to create a narrated presentation, and can be compared with the version recorded using Camtasia Studio.