995 resultados para Ambient air
Resumo:
Chicken eggs were inoculated with suspensions of ambient air particles (<= 10 mu m, PM(10)) from Sao Paulo city in 3, 0.3 or 0.03 mu g doses on one of the four early days of embryo development. On the eleventh day of development alterations were observed on embryos inoculated with PM(10) 3 mu g on the third day. Particles analysis showed high content of metals. Hence, embryos were also inoculated with PM(10) (3 mu g) combined with metal chelating EDTA. PM(10) (3 mu g) embryos presented underdevelopment (stage 29.44 +/- 11.4) compared to vehicle and positive controls (stage 36.44 +/- 0.51 Saline and stage 31.20 +/- 9.7 Cyclophosphamide, p <= 0.05); higher (47%) mortality rate (23% Saline and 42% Cyclophosphamide) and low (68%) viability (100% Saline and 70% Cyclophosphamide, p = 0.04). Effects were attenuated when embryos received PM(10) + EDTA (stage 33.63 +/- 0.94, 18.9% mortality rate and 82% viability). PM(10) from Sao Paulo city is embryotoxic and metal may be implicated in the toxic mechanism. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Air pollution is an important environmental health risk factor that can result in many different gestational and reproductive negative outcomes. In this study, we have investigated the effects of two different times of exposure (before conception and during pregnancy) to urban ambient particulate matter on reproductive and pregnancy outcomes in mice. Using exposure chambers receiving filtered (F) and non-filtered (NF) air, we observed that exposed females exhibited changes in the length of estrus cycle and extended estrus and, therefore, a reduction in the number of cycles during the studied period (F2.6 +/- 0.22 and NF 1.2 +/- 0.29, p = 0.03). The mean number of antral follicles declined by 36% (p = 0.04) in NF mice (75 +/- 35.2) compared to F mice (118.6 +/- 18.4). our results further indicate a significant increase in time necessary for mating and decreased fertility and pregnancy indices (p = 0.003) in NF couples. Mean post-implantation loss rates were increased by 70% (p <= 0.005) in the NF2 group (exposed before and during pregnancy to NF air) compared to the F1 group (exposed before and during pregnancy to F air) and were influenced by both pre-gestational (p < 0.004) and gestational (p < 0.01) period exposure. Fetal weight was significantly higher in the F1 group when compared with the other groups (p < 0.001), at a 20% higher weight in the F1 group (0.86 +/- 0.18 g) than in the NF2 group (0.68 +/- 0.10g). Furthermore, fetal weight was influenced by both pre-gestational and gestational period exposure, and a significant interaction between these two factors was found (p < 0.001). This study demonstrated that exposure to ambient levels of urban traffic-generated particulate matter negatively affects different functions and stages of the reproductive process. Our results also reinforce the idea that maternal exposure to air pollution is linked to negative pregnancy outcomes, even if the exposure occurs only before conception. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
In Brazil, sugarcane fields are often burned to facilitate manual harvesting, and this burning causes environmental pollution from the large amounts of soot released into the atmosphere. This material contains numerous organic compounds such as PAHs. In this study, the concentrations of PAHs in two particulate-matter fractions (PM(2.5) and PM(10)) in the city of Araraquara (SE Brazil, with around 200,000 inhabitants and surrounded by sugarcane plantations) were determined during the sugarcane harvest (HV) and non-harvest (NHV) seasons in 2008 and 2009. The sampling strategy included four campaigns, with 60 samples in the NHV season and 220 samples in the HV season. The PM(2.5) and PM(10) fractions were collected using a dichotomous sampler (10 L min(-1), 24 h) with Teflon (TM) filters. The filter sets were extracted (ultrasonic bath with hexane/acetone (1:1 v/v)) and analyzed by HPLC/Fluorescence. The median concentration for total PAHs (PM(2.5) in 2009) was 0.99 ng m(-3) (NHV) and 3.3 ng m(-3) (HV). In the HV season, the total concentration of carcinogenic PAHs (benz(a)anthracene, benzo(b)fluoranthene, benzo(k)fluoranthene, and benzo(a)pyrene) was 5 times higher than in the NHV season. B(a)P median concentrations were 0.017 ng m(-3) and 0.12 ng m(-3) for the NHV and HV seasons, respectively. The potential cancer risk associated with exposure through inhalation of these compounds was estimated based on the benzo[a]pyrene toxic equivalence (BaP(eq)), where the overall toxicity of a PAR mixture is defined by the concentration of each compound multiplied by its relative toxic equivalence factor (TEF). BaP(eq) median (2008 and 2009 years) ranged between 0.65 and 1.0 ng m(-3) and 1.2-1.4 ng m(-3) for the NHV and HV seasons, respectively. Considering that the maximum permissible BaPeq in ambient air is 1 ng m(-3), related to the increased carcinogenic risk, our data suggest that the level of human exposure to PAHs in cities surrounded by sugarcane crops where the burning process is used is cause for concern. (C) 2010 Published by Elsevier Ltd.
Resumo:
An increased risk of early pregnancy loss in women briefly exposed to high levels of ambient particulate matter during the preconceptional period was recently observed. The effects of this exposure on early embryo development are unknown. This study was designed to assess the dose-response and biological effects of diesel exhaust particles (DEP) on in vitro embryo development using the in vitro fertilization (IVF) mouse model. Zygotes obtained from superovulated mice after IVF were randomly cultured in different DEP concentrations (0, 0.2, 2, and 20 mu g/cm(2)) for 5 days and observed for their capacity to attach and develop on a fibronectin matrix until day 8. Main outcome measures included blastocyst rates 96 and 120 h after insemination, hatching discriminatory score, total cell count, proportion of cell allocation to inner cell mass (ICM) and trophectoderm (TE), ICM morphology, attachment rate and outgrowth area, apoptosis and necrosis rates, and Oct-4 and Cdx-2 expression. Multivariate analysis showed a negative dose-dependent effect on early embryo development and hatching process, blastocyst cell allocation, and ICM morphology. Although blastocyst attachment and outgrowth were not affected by DEP, a significant impairment of ICM integrity was observed in day 8 blastocysts. Cell death through apoptosis was significantly higher after DEP exposure. Oct-4 expression and the Oct-4/Cdx-2 ratio were significantly decreased in day 5 blastocysts irrespective of DEP concentration. Results suggest that DEP appear to play an important role in disrupting cell lineage segregation and ICM morphological integrity even at lower concentrations, compromising future growth and viability of the blastocyst.
Resumo:
Smoked cocaine (crack cocaine) causes several forms of injury to the respiratory tract, including asthma exacerbations, lung edema and hemorrhage, and nasal mucosal alterations. Few studies, however, have assessed respiratory tract pathology in habitual users of crack cocaine. Here, we describe the histological alterations in the respiratory tract of mice caused by chronic inhalation of crack cocaine. Twenty 2-month-old BALB/c mice were exposed to the smoke of 5 g crack cocaine in an inhalation chamber once a day for two months and compared to controls (n = 10). We then morphometrically analyzed nose and bronchiolar epithelial alterations, bronchiolar and alveolar macrophage cell density, alveolar hemosiderin content, and in addition determined the vasoconstriction index and the wall thickness of pulmonary arteries. The serum cocaine level was 212.5 ng/mL after a single inhalation. The mucus content of the nasal epithelium increased in crack-exposed animals, and the nasal and bronchial epithelium thickness decreased significantly. The alveolar hemosiderin content and the alveolar and bronchiolar macrophage cell density increased in animals exposed to crack. The vasoconstriction index increased in the pulmonary arteries of the exposed group. Chronic crack cocaine inhalation causes extensive histological changes along the entire respiratory tract.
Resumo:
Purpose: The objective of this study was to verify the influence of test environment on the flexural strength of dental porcelains with distinct microstructures. Material and Methods: Disk-shaped specimens from three dental porcelains with distinct leucite content (VM: zero; CE: 12; NS: 22 vol%) were manufactured and tested for biaxial flexural strength in air and immersed in artificial saliva. The results were analyzed by means of two-way ANOVA and Tukey`s test (alpha = 0.05). Results: The flexural strength (MPa) obtained for ambient air and artificial saliva environments, respectively, were: 110.0 +/- 16.0 and 81.5 +/- 10.8 for VM; 51.9 +/- 4.0 and 42.0 +/- 4.7 for CE; 72.0 +/- 11.5 and 63.6 +/- 5.8 for NS. A numerical decrease in the mean flexural strength was observed for all groups when specimens were tested under artificial saliva; however, the difference was only statistically significant for VM. Conclusions: The results indicate that the effect of water immersion on the flexural strength of dental porcelains varies according to their leucite content, as only the material without leucite in its microstructure (VM) showed significant strength degradation when tested under water.
Resumo:
Purpose: To determine whether constriction of proximal arterial vessels precedes involution of the distal hyaloid vasculature in the mouse, under normal conditions, and whether this vasoconstriction is less pronounced when the distal hyaloid network persists, as it does in oxygen-induced retinopathy (OIR). Methods: Photomicrographs of the vasa hyaloidea propria were analysed from pre-term pups (1-2 days prior to birth), and on Days 1-11 post-birth. The OIR model involved exposing pups to similar to 90% O-2 from D1-5, followed by return to ambient air. At sampling times pups were anaesthetised and perfused with india ink. Retinal flatmounts were also incubated with FITC-lectin (BS-1, G. simplicifolia,); this labels all vessels, allowing identification of vessels not patent to the perfusate. Results: Mean diameter of proximal hyaloid vessels in preterm pups was 25.44 +/- 1.98 mum; +/-1 SEM). Within 3-12 hrs of birth, significant vasoconstriction was evident (diameter:12.45 +/- 0.88 mum), and normal hyaloid regression subsequently occurred. Similar vasoconstriction occurred in the O-2-treated group, but this was reversed upon return to room air, with significant dilation of proximal vessels by D7 (diameter: 31.75 +/- 11.99 mum) and distal hyaloid vessels subsequently became enlarged and tortuous. Conclusions: Under normal conditions, vasoconstriction of proximal hyaloid vessels occurs at birth, preceding attenuation of distal hyaloid vessels. Vasoconstriction also occurs in O-2-treated pups during treatment, but upon return to room air, the remaining hyaloid vessels dilate proximally, and the distal vessels become dilated and tortuous. These observations support the contention that regression of the hyaloid network is dependent, in the first instance, on proximal arterial vasoconstriction.
Resumo:
A preocupação sobre a qualidade do ar nas zonas industriais confere aos estudos sobre a qualidade do ar uma importância acrescida. Este trabalho teve como objectivo saber qual a contribuição dos principais poluentes provenientes do tráfego automóvel para a qualidade do ar na zona do parque industrial da Sapec, da Península da Mitrena, concelho de Setúbal, recorrendo ao modelo meteorológico e de qualidade do ar, TAPM (The Air Pollution Model). Neste trabalho analisaram-se dados da estação de monitorização da qualidade do ar, mais próxima da zona de estudo (Subestação) por forma a caracterizar-se a zona em causa, a nível meteorológico e da qualidade do ar. Os dados metereológico desta estação também foram utilizados com o objectivo de se validar os resultados meteorológicos obtidos pelo modelo. Na avaliação da contribuição do tráfego para a qualidade do ar, recorreu-se a um estudo de tráfego realizado pela Estradas de Portugal (EP) em 2004. Este estudo realizou a contagem dos veículos que se dirigiram ao parque industrial nos dias 14 e 15 de Dezembro, num período de 24 horas. A partir dessa contagem e de factores de emissão foi possível determinar a contribuição, de cada classe de veículo, para as concentrações atmosféricas de PM10 (resultantes de processos de combustão e ressuspensão), NOx, CO e HC. A comparação entre os dados meteorológicos simulados e medidos mostram que o modelo teve um bom comportamento, isto é, as discrepâncias entre os valores simulados e medidos foram mínimas. Relativamente à contribuição de cada categoria de veículos para a qualidade do ar, verificou-se que a classe de pesados de mercadorias foi aquela que mais contribui para as emissões de PM10, NOx e HC, enquanto que para as emissões de CO foram os veículos ligeiros de passageiros que tiveram uma maior contribuição. As classes dos motociclos e ciclomotores foram aquelas que tiveram uma menor contribuição para as concentrações atmosféricas de poluentes. Comparando as emissões de PM10 provenientes dos processos de combustão e de ressuspensão conclui-se que a maior percentagem provem da ressuspensão.
Resumo:
Atmospheric aerosols of four aerodynamic size ranges were collected using high volume cascade impactors in an extremely busy roadway tunnel in Lisbon (Portugal). Dust deposited on the tunnel walls and guardrails was also collected. Average particle mass concentrations in the tunnel atmosphere were more than 30 times higher than in the outside urban background air, revealing its origins almost exclusively from fresh vehicle emissions. Most of the aerosol mass was concentrated in submicrometer fractions (65%), and polycyclic aromatic hydrocarbons (PAH) were even more concentrated in the finer particles with an average of 84% of total PAH present in sizes smaller than 0.49 mu m. The most abundant PAH were methylated phenanthrenes, fluoranthene and pyrene. About 46% of the total PAH mass was attributed to lower molecular weight compounds (two and three rings), suggesting a strong influence of diesel vehicle emissions on the production of local particulate PAH. The application of diagnostic ratios confirmed the relevance of this source of PAH in the tunnel ambient air. Deposited dust presented PAH profiles similar to the coarser aerosol size range, in agreement with the predominant origin of coarser aerosol particles from soil dust resuspension and vehicle wear products. (c) 201 1 Elsevier Ltd. All rights reserved.
Resumo:
Bearing in mind the potential adverse health effects of ultrafine particles, it is of paramount importance to perform effective monitoring of nanosized particles in several microenvironments, which may include ambient air, indoor air, and also occupational environments. In fact, effective and accurate monitoring is the first step to obtaining a set of data that could be used further on to perform subsequent evaluations such as risk assessment and epidemiologic studies, thus proposing good working practices such as containment measures in order to reduce occupational exposure. This paper presents a useful methodology for monitoring ultrafine particles/nanoparticles in several microenvironments, using online analyzers and also sampling systems that allow further characterization on collected nanoparticles. This methodology was validated in three case studies presented in the paper, which assess monitoring of nanosized particles in the outdoor atmosphere, during cooking operations, and in a welding workshop.
Resumo:
O biodiesel é uma fonte de energia renovável, que se pode obter pela transformação dos resíduos domésticos, e é ambientalmente inócuo, e fácil de transportar, pois tem um ponto de fulgor elevado. Atualmente tem-se focado a atenção nos efeitos da oxidação do biodiesel causados pelo contato com o ar ambiente durante o seu armazenamento. Os produtores, fornecedores e consumidores, pretendem garantir que a qualidade do biodiesel e das suas misturas com combustíveis destilados do petróleo, mantém-se durante longos períodos de armazenamento. A maioria dos óleos vegetais e das gorduras animais, usados como matéria – prima, são triacilgliceróis com grupos ácido gordos de cadeia longa (C16 – C18) ligados por ligações éster a uma estrutura de glicerol. O objetivo deste estudo foi avaliar a eficiência do ácido gálhico e seus derivados alquilo ésteres aumentando a resistência relativa à oxidação do ácido linoléico, inibindo a peroxidação ácido gordos de cadeia longa insaturados. Outro objetivo foi estudar a taxa de inibição da auto-oxidação do ácido linoleico. Foi, ainda estudado o efeito que a concentração do antioxidante, tinha na estabilidade do ácido linoleico. No caso do ácido gálhico verificou-se que o aumento para o dobro da concentração do antioxidante utilizada, obtinha-se quase o dobro da taxa de inibição da oxidação do ácido linoleico. A auto-oxidação de ácido linoleico é acompanhada pela formação do seu dieno conjugado, o qual foi medido sua absorvância, durante 7 dias, por espetrofotometria de absorção UV a 234 nm. Uma diminuição da taxa de formação de dieno conjugado, indica o aumento da atividade antioxidante do composto adicionado à micela de ácido linoleico. Os resultados obtidos permitem concluir que de todos os antioxidantes testados o galhato de butilo é o que possibilita uma maior inibição da oxidação do ácido linoleico para as duas concentrações de antioxidantes testadas (0,1 mM e 1mM), obteve-se uma percentagem de inibição do ácido linoleico de 54,0% e 63,6%, respetivamente. O estudo comparativo da estabilização do ácido linoleico com o antioxidante de referência, o butil -hidroxitolueno, mostrou que este composto tem um poder de estabilização inferior a qualquer dos antioxidantes estudados. Os resultados deste estudo demonstraram que a utilização de compostos fenólicos, em especial o galhato de butilo, constitui uma boa alternativa para a estabilização de matrizes lipídicas, nomeadamente de combustíveis como o biodiesel.
Resumo:
Atmospheric pollution by motor vehicles is considered a relevant source of damage to architectural heritage. Thus the aim of this work was to assess the atmospheric depositions and patterns of polycyclic aromatic hydrocarbons (PAHs) in façades of historical monuments. Eighteen PAHs (16 PAHs considered by US EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) were determined in thin black layers collected from façades of two historical monuments: Hospital Santo António and Lapa Church (Oporto, Portugal). Scanning electron microscopy (SEM) was used for morphological and elemental characterisation of thin black layers; PAHs were quantified by microwave-assisted extraction combined with liquid chromatography (MAE-LC). The thickness of thin black layers were 80–110 μm and they contained significant levels of iron, sulfur, calcium and phosphorus. Total concentrations of 18 PAHs ranged from 7.74 to 147.92 ng/g (mean of 45.52 ng/g) in thin black layers of Hospital Santo António, giving a range three times lower than at Lapa Church (5.44– 429.26 ng/g; mean of 110.25 ng/g); four to six rings compounds accounted at both monuments approximately for 80–85% of ΣPAHs. The diagnostic ratios showed that traffic emissions were significant source of PAHs in thin black layers. Composition profiles of PAHs in thin black layers of both monuments were similar to those of ambient air, thus showing that air pollution has a significant impact on the conditions and stone decay of historical building façades. The obtained results confirm that historical monuments in urban areas act as passive repositories for air pollutants present in the surrounding atmosphere.
Resumo:
The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.
Resumo:
RESUMO: O objectivo deste trabalho foi avaliar se a exposição crónica neonatal à hiperóxia mo-derada induz alterações funcionais e estruturais persistentes nas vias aéreas. Desenvolveu-se um modelo animal, no rato, a partir do qual se retiraram implicações para a compreensão das repercussões crónicas da hiperóxia neonatal sobre as vias aéreas de displasia broncopulmonar (DBP), em duas fases distintas: imediatamente após a exposi-ção neonatal a 50%O2 (grupo 50%O2) e após três semanas de recuperação em ar ambiente (grupo 50%O2+Ar).Compararam-se os resultados da resposta do músculo liso de traqueia (MLT) à esti-mulação in vitro com metacolina e salbutamol e avaliaram-se as alterações quantitativas da área de MLT, bem como as alterações qualitativas da estrutura da traqueia. Demonstrou-se que a exposição a 50% de oxigénio não tinha repercussões imediatas sobre a resposta in vitro do MLT à estimulação colinérgica, mas que induzia um aumento do relaxamento em resposta ao salbutamol. A contractilidade do MLT em resposta à estimula-ção com metacolina no grupo 50%O2+Ar foi significativamente superior à do grupo de con-trolo da mesma idade e também superior à observada no grupo 50%O2, enquanto que a resposta ao salbutamol se voltou a aproximar dos valores de controlo após a recuperação em normóxia. Não se observaram diferenças estatisticamente significativas na área de MLT entre os grupos experimental e de controlo, o que se deve provavelmente ao número reduzido de amostras avaliadas e à variabilidade deste parâmetro no grupo de controlo; contudo, verifi-cou-se um aumento médio de 15% imediatamente após a exposição à hiperóxia que persis-tiu após o período de recuperação.As alterações qualitativas sobre a arquitectura da traqueia, avaliadas por microscopia óptica, revelaram no grupo 50%O2 aumentos da espessura da matriz extracelular e da den-sidade de mastócitos desgranulados na submucosa e adventícia vizinhas do MLT, sem outras alterações relativamente ao grupo de controlo com 15 dias. As alterações da matriz extrace-lular foram reversíveis após a recuperação em ar ambiente. A densidade de mastócitos per-maneceu superior à do grupo de controlo de 36 dias de idade, apresentando-se em maior contiguidade com o MLT relativamente ao grupo 50%O2. Em síntese, demonstrou-se que a hiperóxia neonatal crónica em níveis moderados in-duz alterações da resposta contráctil do MLT e da estrutura da traqueia que podem ter ex-pressão funcional após a exposição ter cessado. Assim, o contributo original do presente trabalho foi o desenvolvimento de um modelo animal que permite avaliar os mecanismos pelos quais a hiperóxia é capaz de induzir, isoladamente, alterações crónicas da contracti-lidade, do relaxamento do ML e da estrutura das vias aéreas que podem ser responsáveis pela HRB persistente em doentes sujeitos a oxigenioterapia neonatal.-------------ABSTRACT: The aim of this work was to evaluate whether chronic neonatal exposure to hyperoxia in-duces persistent structural and functional airway changes. An animal model was developed, using neonatal rats, in order to understand the chronic effects of neonatal hyperoxia on the airways, in bronchopulmonary dysplasia, in two distinct phases: immediately after neonatal exposure to 50%O2 (50%O2 group) and after three weeks of recovery at ambient air (50%O2+Ar group).The results from the tracheal smooth muscle (TSM) response to in vitro stimulation with metacholine and salbutamol were compared and quantitative changes in TSM area, as well as qualitative changes in tracheal structure were evaluated. It was demonstrated that while exposure to 50% oxygen had no immediate effects on in vitro TSM response to cholinergic stimulation, it induced an increase in relaxation as a result of salbutamol administration. TSM contractility as a result of methacholine administration in the 50%O2 + Ar group was significantly higher than that of the same-age control group, and also higher than the one observed in the 50%O2 group, whereas the response to salbutamol admini-stration was once again closer to the control values after recovery in normoxia. There were no statistically significant differences in the TSM area between the experi-mental and control groups, which is most likely due to the reduced number of samples evalu-ated and to the variability of this parameter in the control group. However, there was an aver-age increase of 15% immediately after exposure to hyperoxia, which persisted after the recov-ery period. Qualitative changes in tracheal architecture, evaluated by optic microscopy, revealed that the 50%O2 group suffered an increase in the thickness of the extracellular matrix and degranu-lated mast cell density in the submucosa and adventitia adjacent to the TSM, without further changes when compared with the control group at 15 days of age. The changes in extracellular matrix were reversible after recovery in ambient air. Mast cell density remained higher than that of the control group at 36 days of age, and more contiguous to TSM than the 50%O2 group. In conclusion, it has been demonstrated that moderate levels of chronic neonatal hyperoxia in-duce changes in TSM contractile response and tracheal structure, which may be functionally ex-pressed after discontinuation of exposure. Therefore, the original contribution of the present work was the development of an animal model which allows the evaluation of the mechanisms through which hyperoxia alone can induce chronic changes in contractility and relaxation of SM and also in airway structure that can be responsible for the persistent airway hyperrespon-siveness found in patients who were submited to neonatal oxygen therapy.